Fault Possible cause Remedial action
The light does not function. The LED light is defective. See chapter “Light (LED)” section.
Appliance was open too
long.
Light is switched off after
approx. 10 min.
When the appliance is closed and opened,
the light is on again.
There is a thick layer of frost
in the freezer compartment.
Defrosting the freezer compartment (see
chapter Defrosting). Always ensure that the
freezer compartment door is closed properly.
Bottom of the refrigerator
compartment is wet.
The condensation channel
or drainage hole are blocked.
Clean the condensation channel
and the drainage hole. See chapter Cleaning
the appliance. Fig. %
The temperature
in the refrigerator
compartment is too cold.
Freezer compartment door is
open.
Close the freezer compartment door.
The freezer compartment door engages
audibly.
Temperature has been set
too low.
Increase the temperature.
The Super function is
switched on.
Switch off Super function.
The refrigerating unit
is switching on more
frequently and for longer.
Appliance opened
frequently.
Do not open the appliance unnecessarily.
The ventilation openings
have been covered.
Remove obstacles.
Appliance is not cooling,
temperature display and light
are lit.
Showroom mode is
switched on.
Hold down alarm button, Fig "/5, for
10 seconds until an acknowledgement signal
sounds.
After a short time check whether your
appliance is cooling.