Loading ...
Loading ...
Loading ...
49
OPTION menu
Item Description
SERVICE
(continued)
COMMUNICATION
(continued)
RESPONSE LIMIT TIME
Select the time period to wait for receiving
response data from other device communicating by
the NETWORK BRIDGE and the HALF-DUPLEX
through the CONTROL port.
OFF
ó
1s
ó
2s
ó
3s
OFF: Select this mode if it is not required to check
the responses from the device that the projector
sends data to. In this mode, the projector can
send out data from the computer continuously.
1s /2s /3s: Select the time period to keep the
projector waiting for response from the device
that the projector sends data to. While waiting the
response, the projector does not send out any
data from the CONTROL port.
• This menu is available only when the NETWORK
BRIDGE is selected for the COMMUNICATION
TYPE and the HALF-DUPLEX is selected for the
TRANSMISSION METHOD (
48).
• OFF is selected as the default setting.
BYTES INTERVAL TIMEOUT
Select the blank time length to judge that the
response data has nished in the communicating
in the condition of the NETWORK BRIDGE and
the HALF-DUPLEX through the CONTROL port.
50ms
ó
100ms
ó
150ms
ó
200ms
• This menu is available only when NETWORK
BRIDGE is selected for the COMMUNICATION
TYPE and HALF-DUPLEX is selected for the
TRANSMISSION METHOD (
48).
50ms is selected as the default setting.
(continued on next page)
Loading ...
Loading ...
Loading ...