7
5 CUSTOM DRAWER PANEL CALCULATIONS
The following calculations assume the top of the upper panel is
aligned with the top of the adjacent cabinetry.
The final panel/cabinetry alignment is achieved by adjusting the feet:
WIDTH OF ALL PANELS
Measure A (the width between adjacent door/drawer fronts)
and write it in the first box below, then complete the equation.
HEIGHT OF THE UPPER PANEL
HEIGHT OF THE LOWER PANEL
Measure C (door/drawer height (or equivalent)) and write it in the
first box below, then complete the equation.
min. 2mm
Ventilation Gap (min. 8mm)
min. 2mm
min. 2mm
min. 2mm
WIDTH OF ALL PANELS
UPPER PANEL
LOWER PANEL
TOEKICK PANEL
HEIGHT OF
LOWER PANEL
HEIGHT OF
UPPER PANEL
C
A
B
A
B
C
Clearance to adjacent
cabinet front
(min. 2mm)
(0mm recommended)
(min. 311mm)
(min. 8mm)
(596 - 615mm)
Height of
Upper Panel
Upper Panel extension
Ventilation Gap
(min 717mm + B)
minimum
height
WIDTH OF PANEL
HEIGHT OF
UPPER PANEL
HEIGHT OF
LOWER PANEL
398mm
Note: The ‘upper panel extension’ B allows for the top of the upper
panel to extend above the chassis where required, however a
min. 2mm gap to the benchtop must be maintained.
Note: The ‘upper panel extension’ B
allows for the top of the upper panel to
extend above the chassis where required,
however a min. 2mm gap to
the benchtop must be maintained.
- 2x =
=
=
+
--
FRONT PANEL MATERIAL SPECIFICATIONS
16 - 20mm panel thickness
Adequately sealed to withstand moisture (50
O
C @ 80% RH)
Because of it being a hot and wet environment generally, the back and sides of the
panel should be completely sealed with a waterproof vapour barrier (ie polyurethane)
to prevent damage to the panel.
The back of the panel (including any integrated handle) should be completely flush
so that the seal between the panel and the rubber trim is maintained.
Installation outside these specs may result in condensation on cabinetry surfaces.
Maximum weight of each panel: 9kg