outlet, then continue normal operation.
Caution: In order to avoid hazard due to inadvertent resetting of the thermal cutout, this appliance must not be supplied
through an external switching device, such as a timer, or connected to a switch that is regularly switched on and o by the
utility.
Tips for using your appliance.
1. With the ame and smoke setting on minimum the unit will use approximately 40ml of water per hour and will last 3 times
as long than when it is at maximum ame setting.
2. Do not tilt or move the re while there is water in the tank or sump.
3. Make sure that the re is xed level on the wall.
4. The ame control knob ‘D’ Fig.2 may be turned up or down to give a more realistic eect.
5. Sometimes the ames appear more real when the ame control knob is turned down to a low setting.
6. Give the ame generator some time to react to changes you may make on the ame control knob.
Maintenance
WARNING: ALWAYS DISCONNECT FROM THE POWER SUPPLY BEFORE ATTEMPTING ANY MAINTENANCE
Changing lamps.
If a large amount of the smoke appears grey or colourless it may be that one or more lamps have failed.
You can check for lamp failure as follows.
1. Leaving the ame eect on, lift out the fuelbed and water tank. (See Fig.3) and lift out the nozzle (See Fig.4)
2. View the lamps from a distance in front of the re and observe which lamp needs to be changed.
3. Press switch A to o (0) position (See Fig.2), and unplug the re from the mains.
4. Leave the appliance for 20 minutes to allow the lamps to cool down before removing them.
5. Remove the water tank by lifting upwards and place in a sink.
6. Remove the sump as described in the Cleaning Section.
7. Remove the defective lamp, by gently lifting vertically and disengaging the pins from the lamp holder, (See Fig.4 and 4a).
Replace with a Dimplex Opti-myst, 12V, 50W, Gu5.3 base, 8º beam angle, coloured lamp. (Purchased from www.dimplex.co.uk
under the section After Sales Service, details of how to purchase the lamps are contained therein.)
8. Carefully insert the two pins of the new lamp into the two holes in the lamp holder. Push lamp rmly in place. (See Fig.4 and
4a).
9. Replace the nozzle, water tank and fuelbed.
10. Switch on.
Filling the water tank.
When the water tank is empty, the ame and smoke eect shuts o and you will hear 2 audible ‘beeps,, follow these steps.
1. Press Switch A to o position (0) (See Fig.2)
2. Gently lift out the fuelbed and place carefully on the ground. (See Fig.3)
3. Remove the water tank by lifting upwards and outwards.
4. Place the water tank in sink and remove cap, Anti-clockwise to open. (See Fig.5)
5. Fill tank with ltered tap water only. This is necessary to prolong the life of the ame and smoke producing unit.
The water should be ltered through a conventional domestic water lter unit and the lter should be replaced regularly.
6. Screw the cap back on, do not overtighten.
7. Return the tank to the sump, with the tank cap facing down and the at side of the tank facing outward.
8. Gently place the fuelbed back into position.
9. Press Switch A to ON’ ( I ) position (See Fig.2)
Cleaning.
WARNING – ALWAYS DISCONNECT FROM THE POWER SUPPLY BEFORE CLEANING THE HEATER.
We Recommend cleaning the following components once every 2 weeks, particularly in hard water areas:-
Water Tank, Sump, Nozzle, Tank cap and seal, Air lter.
For general cleaning use a soft clean duster – never use abrasive cleaners. To remove any accumulation of dust or u the soft
brush attachment of a vacuum cleaner should occasionally be used to clean the outlet grille of the fan heater.
Water tank
1. Remove water tank, as described earlier, put into sink and empty water.
2. Using the supplied brush gently rub the inside surfaces of the cap paying particular attention to the rubber ring in the outer
groove and the centre rubber seal.
3. Put a small quantity of washing up liquid and water into the tank, ret the cap and shake well, rinse out until all traces of
washing up liquid are gone.
4. Rell with ltered tap water only, replace the cap, do not overtighten.
Sump
1. Press Switch A to the OFF’ (0) position
2. Gently lift out the fuelbed and place carefully on the ground. (See Fig.3)
3. Remove the water tank by lifting upwards.