Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance with oven.
Recessed installation area must provide complete
enclosurearound the recessed portion of the oven.
Grounded electrical supply is required. See the
“ElectricalRequirements” section.
Electrical supply junction box should be located 3" (7.6cm)
maximum below the support surface when the oven is
installed in a wall cabinet. A 1" (2.5 cm) minimum diameter
hole should have been drilled in the right rear or left rear
corner of the support surface to pass the appliance cable
through to the junction box.
NOTE: For undercounter installation, it is recommended
that the junction box be located in the adjacent right or
leftcabinet. If you are installing the junction box on rear
wallbehind oven, it is recommended that the junction box
berecessed and located in the upper center of the cabinet.
Oven support surface must be solid, level, and ush
withbottom of cabinet cutout.
Floor must be able to support a single oven weight of 200lbs
(91 kg)
for 30" (76.2 cm) models.
Floor must be able to support a double oven weight of
330lbs (150 kg)
for 30" (76.2 cm) models.
IMPORTANT: To avoid damage to your cabinets, check
with your builder or cabinet supplier to make sure that the
materials used will not discolor, delaminate, or sustain other
damage. This oven has been designed in accordance with
the requirements of UL and CSA International and complies
with the maximum allowable wood cabinet temperatures
of194°F (90°C).
Undercounter Installation (with Cooktop Installed Above):
Ovens approved for this type of installation have an approval
label located on the top of the oven. Refer to Cutout Dimensions
for Ovens Installed Under Cooktop (separate sheet).
Product Dimensions - Single Ovens
B
C
D
E
A
G
F
30" (76.2 cm) models
A. 28
3
/
4
" (72.8 cm) max. overall height
B. 28
1
/
2
" (72.4 cm) max. recessed width
C. 26
3
/
4
" (67.9 cm) recessedheight
D. 23
1
/
4
" (59.1 cm) max. recessed depth
E. 30" (76.2 cm) overall width
F. 12" (30.5 cm) from back of control
panel to start ofstrain relief
G. 48" (121.9 cm) exible conduit length