Loading ...
Loading ...
Loading ...
En-13
Airow is weak or stops.
Is the fan speed set to Quiet?
To change the fan speed, refer to page 5.
Has the Fan Control for Energy Saving set? In this case, the
indoor unit fan may stop temporarily while the Cooling operation.
To cancel the Fan control for energy saving, refer to page 7.
<In the Heating mode> Have you just started the operation?
In this case, the fan rotates at very low speed temporarily to warm
up the internal parts of the unit.
<In the Heating mode> Is the room temperature higher than the
set temperature?
In this case, the outdoor unit stops and the indoor unit fan rotates
at very low speed.
<In the Heating mode> Is [
] indicator blinking?
In this case, the Automatic defrosting operation is working. The in-
door unit stops for maximum of 15 minutes. (Refer to page 10.)
<In the Dry mode> The indoor unit operates at low fan speed to
adjust the room humidity, and may stop from time to time.
<In the Auto mode> While the monitoring operation, the fan
rotates at very low speed.
Noise is heard.
Is the unit operating, or immediate after stopping operation?
In this case, refrigerant owing sound may be heard. It may be
particularly noticeable for 2-3 minutes after starting operation.
Do you hear a slight squeaking sound during the operation?
This sound is produced by the minute expansion and contraction
of the front panel caused by temperature change.
<In the Heating mode> Do you hear a sizzling sound?
This sound is produced by the Automatic defrosting operation.
(Refer to page 10.)
Smell coming from the unit.
The air conditioner may absorb various smells generated from
interior textile, furniture, or cigarette smoke. These smells may be
emitted during the operation.
Mist or steam is emitted from the unit.
<In the Cooling or Dry mode> A thin mist may be generated by
condensation formed with sudden cooling process.
<In the Heating mode> Is [
] indicator on the indoor unit blinking?
In this case, steam may rise from the outdoor unit because of the
Automatic defrosting operation.(Refer to page 10.)
Outdoor unit emits water.
<In the Heating mode> The outdoor unit may emit water gener-
ated by the Automatic defrosting operation. (Refer to page 10.)
The unit operates di󰀨erently from the remote controller setting.
Do you have an arrangement with your electric company for
Demand Response?
In this case, the air conditioning performance may become lower
or the operation may stop. (Refer to page 7.)
Are the batteries in the remote controller exhausted?
Replace the batteries.
Operation is delayed after restart.
Has the power supply turned from O󰀨 to On suddenly?
In this case, the compressor will not operate for about 3 minutes
to prevent a blowout of the fuse.
Immediately stop operation and turn o󰀨 the electrical breaker in
following cases. Then consult authorized service personnel.
The problem persists even if you perform these checks or
diagnostics.
On the indoor unit, [
] and [ ] blink while [ ] is blinking fast.
NOTES: For any troubleshooting related to the W-LAN control, refer
to the setting manual for W-LAN adapter or the mobile app
installed in your smartphone or tablet PC.
13. TROUBLESHOOTING
WARNING
In the following events, immediately stop operation of
the air conditioner, and disconnect all the power supply
by turning o󰀨 the electrical breaker or disconnecting
the power plug. Then consult your dealer or authorized
service personnel.
As long as the unit is connected to the power supply, it
is not insulated from the power supply even if the unit is
turned o󰀨.
Unit smells of something burning or emits smoke
Water leaks from the unit
Does not operate at all.
Has there been a power outage?
In this case, the unit restarts automatically after the power supply
is resumed. (Refer to page 10.)
Has the circuit breaker been turned o󰀨?
Turn on the circuit breaker.
Has a fuse blown out or the circuit breaker been tripped?
Replace the fuse or reset the circuit breaker.
Is the timer operating?
To check or deactivate the timer setting, refer to page 5.
Poor cooling or heating performance.
Is the unit operating under the conditions except the permissible
temperature range?
In this case, the air conditioner may stop because of the automatic
protection circuit working.
Do you have an arrangement with your electric company for
Demand Response?
In this case, the air conditioning performance may become lower
or the operation may stop. (Refer to page 7.)
Is the air lter dirty?
Clean the air lter. (Refer to page 9.)
Is the intake grille or outlet port of indoor unit blocked?
Remove the obstructions.
Is the room temperature adjusted appropriately?
To change the temperature setting, refer to page 5.
Is a window or door left opened?
Close the window or the door.
Is the fan speed set to Quiet?
To change the fan speed, refer to page 5.
Has the Outdoor Unit Low Noise operation been set?
To stop the Outdoor Unit Low Noise operation, refer to page
8.
<In the Cooling mode> Is direct or strong sunlight shining into the
room?
Close the curtains.
<In the Cooling mode> Are there other heating apparatus or com-
puters operating, or too many people in the room?
Turn the heating apparatus or computers o󰀨, or set the
temperature lower. (Refer to page 5.)
Loading ...
Loading ...