en
7
Note
The appliance is fully functional within
the room temperature limits
of the indicated climatic class. If
an appliance of climatic class SN
is operated at colder room temperatures,
the appliance will not be damaged up to
a temperature of +5 °C.
Ventilation
Fig. !/24
The refrigeration unit is ventilated only via
the ventilation grille in the base. Never
cover the ventilation grille or place
anything in front of it. Otherwise
the refrigeration unit must work harder,
increasing the power consumption.
Installation location
Install the appliance in a dry, well
ventilated room. The installation location
should neither be exposed to direct
sunlight nor near a heat source, e. g.
a cooker, radiator, etc. If installation next
to a heat source is unavoidable, use
a suitable insulating plate or observe
the following minimum distances to a
heat source:
3 cm to electric or gas cookers.
30 cm to an oil or coal-fired cooker.
Connecting
the appliance
After installing the appliance, wait at least
1 hour until the appliance is switched on.
During transportation the oil in
the compressor may have flowed into
the refrigeration system.
Before switching on the appliance for
the first time, clean the interior of
the appliance (see chapter “Cleaning
the appliance”).
Electrical connection
The socket must be near the appliance
and also freely accessible following
installation of the appliance.
The appliance complies with the
protection class I. Connect the appliance
to 220–240 V/50 Hz alternating current
via a correctly installed socket with
protective conductor. The socket must
be fused with a 10 to 16 A fuse.
For appliances operated in non-
European countries, check whether the
stated voltage and current type match
the values of your mains supply. This
information can be found on the rating
plate. Fig. +
m Warning
Never connect the appliance
to electronic energy saver plugs.
Our appliances can be used with mains
and sine-controlled inverters. Mains-
controlled inverters are used
for photovoltaic systems which
are connected directly to the national
grid. Sine-controlled inverters must be
used for isolated applications (e.g. on
ships or in mountain lodges) which are
not connected directly to the national
grid.