Important Notes to the Installer
1. Read all instructions contained in these installation
instructions before installing the appliance.
2. Remove all packing material before connecting the
electrical supply to the appliance.
3. Observe all governing codes and ordinances.
4. Be sure to leave these instructions with the consumer.
Important Note to the Consumer
Keep these instructions with your Owner's Guide for the
local electrical inspector's use and future reference.
IMPORTANT SAFETY
INSTRUCTIONS
Be sure your appliance is installed and grounded
properly by a qualified installer or service
technician.
These appliances must be electrically grounded in
accordance with local codes or, in their absence,
with the National Electrical Code CSA Standard
C22.1, Canadian Electrical Code, Part 1, in Canada.
The electrical power to the appliance
must be shut off while line connections are being
made. Failure to do so could result in serious injury
or death.
Provide Electrical Connection
Install the junction box under the cabinet and run
120/240 or 120/208 Volt, AC wire from the main circuit
panel. DO NOT connect the wire to the circuit panel at
this time.
Electrical Requirements
This appliance must be supplied with the proper voltage
and frequency, and connected to an individual, properly
grounded branch circuit, protected by a circuit breaker
or fuse. A circuit breaker or fuse is required by your
appliance. The circuit breaker or fuse amperage
recommended for your appliance is 40A or 50A,
NOTE: Wire sizes and connections must conform with
the fuse size and rating of the appliance in accordance
with the American National Electrical Code ANSI/NFPA
No. 70-latest edition, or with Canadian CSA Standard
C22.1, Canadian Electrical Code, Part 1, and local codes
and ordinances.
An extension cord should not be used
with this appliance. Such use may result in a fire,
electrical shock, or other personal injury.
2. The flexible armored cable extending from the
appliance should be connected directly to the
junction box. The junction box should be located as
shown in Figure 1 or Figure 2 and with as much slack
as possible remaining in the cable between the box
and the appliance, so it can be moved if servicing is
ever necessary.
3. A suitable strain relief must be provided to attach
the flexible armored cable to the junction box.
Unpacking Instructions
,
2.
Figure 3
Model and
Serial Plate
(Under Cooktop)
Leave corner supports on appliance until completion
of Electrical Connection.
Be sure the bottle of cleaner conditioner packed
in the literature bag is left where the user can
find it easily. It is important that the ceramic-glass
smoothtop be pretreated before use. See Appliance
Cleaning and Maintenance section in the Use and
Care Guide.
Observe all governing codes and local ordinances
1.A 3-wire or 4-wire single phase 120/240 or 120/208
Volt, 60 Hz AC only electrical supply is required on a
separate circuit fused on both sides of the line (red
and black wires). A time-delay fuse or circuit breaker is
recommended. DO NOT fuse neutral (white wire). Only
certain cooktop models may be installed over certain
built-in electric oven models. Approved cooktops and
built-in ovens are listed by the MFG ID number (see the
insert sheet included in the literature package).