Burner and nozzle characteristics tables
Nozzles which are not provided are available at Authorised Service Centres.
1
Natural Gas G20 AUX SR RR R1 R2
Rated heating capacity (kW)
1.1 1.7 2.6 3.2 3.0
Nozzle diameter (1/100 mm)
76 95 117 130 126
Reduced capacity (W)
400 500 750 1050 1050
Primary air (mm)
1.0 1.0 1.0 1.5 1.5
2
Natural Gas G25 25 mbar AUX SR RR R1 R2
Rated heating capacity (kW)
1.1 1.7 2.6 3.1 3.0
Nozzle diameter (1/100 mm)
76 95 117 130 126
Reduced capacity (W)
400 500 750 1050 1050
Primary air (mm)
1.0 1.0 1.0 1.5 1.5
3
Natural Gas G25 20 mbar AUX SR RR R1 R2
Rated heating capacity (kW)
1.1 1.7 2.6 3.2 3.0
Nozzle diameter (1/100 mm)
82 105 126 145 135
Reduced capacity (W)
400 500 750 1050 1050
Primary air (mm)
1.0 1.0 1.0 1.5 1.5
4
LPG G30/31 AUX SR RR R1 R2
Rated heating capacity (kW)
1.1 1.7 2.6 3.2 3.0
Nozzle diameter (1/100 mm)
48 62 76 85 82
Reduced capacity (W)
400 500 750 1050 1050
Primary air (mm)
422103
Rated capacity G30 (g/h)
80 124 189 233 218
Rated capacity G31 (g/h)
79 121 186 229 214
5
LPG G30/31 50 mbar AUX SR RR R1 R2
Rated heating capacity (kW)
1.1 1.7 2.6 3.2 3.0
Nozzle diameter (1/100 mm)
42 54 67 73 73
Reduced capacity (W)
450 550 850 1050 1050
Primary air (mm)
2 1 0.5 1.5 1.5
Rated capacity G30 (g/h)
80 131 189 233 218
Rated capacity G31 (g/h)
79 129 186 229 214
6
City Gas G110 8 mbar AUX SR RR R1 R2
Rated heating capacity (kW)
1.1 1.7 2.6 3.2 2.9
Nozzle diameter (1/100 mm)
132 165 230 270 250
Reduced capacity (W)
400 500 750 1050 1050
Primary air (mm)
1.0 0.5 1 1 1
7
City Gas G120 8 mbar AUX SR RR R1 R2
Rated heating capacity (kW)
1.1 1.7 2.6 3.2 3.0
Nozzle diameter (1/100 mm)
126 160 210 240 230
Reduced capacity (W)
400 500 750 1050 1050
Primary air (mm)
1 0.5 1 1 1
Loading ...