MICROWAVE/ WALL OVEN COMBINATION
INSTALLATION INSTRUCTIONS
3
Figure 2
3-WIRE GROUNDED JUNCTION BOX
Cable from Power Supply
Black
Wires
Junction
Box
Cable from appliance
Ground Wire
(Bare or Green Wire)
White Wire
(Neutral)
U.L.-Listed Conduit
Connector (or CSA listed)
Red
Wires
White Wire
(Neutral)
3. Electrical connection
It is the responsibility and obligation of the consumer to
contact a qualied installer to assure that the electrical
installation is adequate and is in conformance
with the National Electrical Code ANSI/NFPA No.
70-latest edition, or with CSA Standard C22.1,
Canadian Electrical Code, Part 1, and local codes and
ordinances.
Risk of electrical shock (Failure to
heed this warning may result in electrocution or
other serious injury.) This appliance is equipped
with copper lead wire. If connection is made to
aluminum house wiring, use only connectors that
are approved for joining copper and aluminum wire
in accordance with the National Electrical Code
and local code and ordinances. When installing
connectors having screws which bear directly on
the steel and/or aluminum exible conduit, do no
tighten screws sufciently to damage the exible
conduit. Do not over bend or excessively distort
exible conduit to avoid separation of convolutions
and exposure of internal wires.
DO NOT ground to a gas supply pipe. DO NOT
connect to electrical power supply until appliance
is permanently grounded. Connect the ground wire
before turning on the power.
(If your appliance is equipped with a
white neutral conductor.)
This appliance is manufactured with a white neutral
power supply and a frame connected copper
wire. The frame is grounded by connection of
grounding lead to neutral lead at the termination
of the conduit, if used in USA, in a new branch
circuit installation (1996 NEC), mobile home,
recreational vehicles, where local code do not
permit grounding trough the neutral (white) wire
or in Canada, disconnect the white and green lead
from each other and use ground lead to ground
unit in accordance with local codes, connect
neutral lead to branch circuit-neutral conductor
in usual manner see Figure 3. If your appliance
is to be connected to a 3 wire grounded junction
box (US only), where local code permit connecting
the appliance-grounding conductor to the neutral
(white) see Figure 2.
NOTE TO ELECTRICIAN: The armored cable leads
supplied with the appliance are UL-recognized for
connection to larger gauge household wiring. The
insulation of the leads is rated at temperatures much
higher than temperature rating of household wiring.
The current carrying capacity of the conductor is
governed by the temperature rating of the insulation
around the wire, rather than the wire gauge alone.
Where local codes permit connecting the
appliance-grounding conductor to the neutral
(white) wire (US Only) (see Figure 2):
1. Disconnect the power supply.
2. In the junction box:
Connect appliance and power supply cable wires as
shown in Figure 3.
Electrical Shock Hazard
Electrical ground is required on this appliance.
Do not connect to the electrical supply until
appliance is permanently grounded.
Disconnect power to the junction box before
making the electrical connection.
This appliance must be connected to a
grounded, metallic, permanent wiring system,
or a grounding connector should be connected
to the grounding terminal or wire lead on the
appliance.
Do not use a gas supply line for grounding the
appliance.
Failure to do any of the above could result in a
re, personal injury or electrical shock.