Operating your air conditioner properly helps you to obtain the best possible results.
This section explains proper air conditioner operation.
IMPORTANT:
NOTE: In the event of a power failure, your air conditioner will operate at the previous settings when the power is restored.
2. Press POWER again to turn off the air conditioner
NOTE: After 5 seconds, display will show the current room temperature.
NOTE: After 5 seconds, display will show the current room temperature.
NOTES:
Press the up arrow button to increase the set temperature. Press the down arrow button to decrease the set temperature.
NOTE: After 5 seconds, the display on the air conditioner control panel will show the current room temperature.
Delayed Shutoff:
Use the timer to set the air conditioner to turn off automatically after a 0.5- to 24-hour delay (the air conditioner must be on):
NOTE: The Set light will turn on while setting.
Delayed Start:
You can also set the air conditioner to turn on automatically after a 0.5- to 24-hour delay.
NOTE: After the set delay, the air conditioner will turn on with the previous settings. Change the mode, fan speed, and/or temperature before setting the timer, if desired.
To Cancel Timer:
After the timer has been set, press TIMER.
Use the thumb wheel on the vent louvers to adjust the air direction left or right.
When your air conditioner is operating normally, you may hear sounds such as:
To help maximize energy efficiency, this air conditioner features a Clear Filter reminder.
After 500 hours of operation, FILTER will illuminate as a reminder that it is time to clean the filter. Once the light is illuminated, it can be turned off by pressing the FILTER button. See the “Air Conditioner Care” section for instructions on how to clean the filter.
Power
Cool
Press COOL to enter Cool mode.
Fan Speed
NOTES:
Eco
Adjusting Temperature
Press the up arrow button to increase the set temperature. Press the down button to decrease the set temperature.
NOTE: After 5 seconds, the display on the air conditioner control panel will show the current room temperature.
Sleep
Automatically adjusts the temperature and fan speed to make the room more comfortable during the night.
Press and hold the SLEEP button for 10 seconds until the Sleep light turns on. All of the left lights will turn off. The set temperature will automatically raise by 1.8°F (1˚C) every 30-60 minutes. At most, the temperature will change six times until the temperature reaches 82°F (28°C). Running time depends upon the set temperature.
Timer
Delayed Shutoff:
Use the timer to set the air conditioner to turn off automatically after a 0.5- to 24-hour delay (the air conditioner must be on):
NOTE: The Set light will turn on while setting.
Delayed Start:
You can also set the air conditioner to turn on automatically after a 0.5- to 24-hour delay.
NOTE: After the set delay, the air conditioner will turn on with the previous settings. Change the mode, fan speed, and/or temperature before setting the timer, if desired.
To Cancel Timer:
After the timer has been set, press TIMER.
Auto:
Press AUTO MODE to enter into Auto mode. In this mode, the fan speed and temperature are set automatically according to the room temperature as tested by the indoor temperature sensor.
Display:
Press DISPLAY to switch on/off all lights or the LED display
Fan only:
Press the Fan Only button to enter Fan Only mode.
Use a small Phillips screwdriver to loosen the battery cover screw. Slide the battery cover down with two thumbs to remove. Remove and properly dispose of old batteries, then replace with two new AAA batteries. Replace the battery cover and tighten the screw.
Your new air conditioner is designed to give you many years of dependable service. This section tells you how to clean and care for your air conditioner properly
On some models, the air filter is located behind the intake grille of air conditioner.
1. Removing the intake grille
Turn off the air conditioner.
2. Removing the air filter
Remove the air filter by pressing down on the tabs on the air intake grille and pulling the grille away from the air conditioner.
Remove the filter from the grille by lifting to release the slotted tabs on the top and bottom of the grille.
Reinstalling the air filter:
On some models, the air filter slides out the side of the intake grille.
1. Removing the air filter
Remove the filter by grasping the tab on the filter and pulling it out of the grille to the side.
Reinstalling the air filter:
The air filter is removable for easy cleaning. A clean filter helps remove dust, lint, and other particles from the air and is important for best cooling and operating efficiency. Check the filter at least once per month to see whether it needs cleaning.
NOTE: Do not operate the air conditioner without the filter in place. Doing so will degrade the unit performance over time.
Use a vacuum cleaner to clean air filter. If the air filter is very dirty, wash it in warm water with a mild detergent.
NOTE: Do not wash the air filter in the dishwasher or use any chemical cleaners; it may damage the filter. Air dry the air filter completely before replacing to ensure maximum efficiency.
Check once or twice a year for paint damage. This is very important, especially in areas near saltwater or where rust is a problem. If needed, touch up with a good grade enamel paint.
Before calling for service, try the suggestions below to see whether you can solve your problem without outside help
| PROBLEM | POSSIBLE CAUSES | RECOMMENDED SOLUTIONS |
| The Air Conditioner Will Not Start |
The air conditioner is unplugged. | Make sure the power supply cord is plugged into a grounded 3 prong outlet. |
| The fuse is blown/circuit breaker is tripped. | Check the house fuse/circuit breaker box and replace the fuse or reset the breaker. | |
| Power failure | The unit will automatically restart when power is restored. There is a protective time delay (approximately 3 minutes) to prevent tripping of the compressor overload. The unit may not start normal cooling for 3 minutes after it is turned back on. | |
| The power cord reset button is tripped. | Press the reset button located on the power cord plug. If the reset button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician. | |
| The Air Conditioner Is Not Cooling Properly |
Airflow is restricted. | Make sure there are no curtains, blinds, or furniture blocking the front of the air conditioner. |
| The temperature control is not set correctly. | Lower the set thermostat temperature. | |
| The air filter is dirty. Clean the filter. | See the “Air Conditioner Care” section | |
| The room is too warm. | Allow time for the room to cool down after turning on the air conditioner. | |
| Cold air is escaping. | Close all open doors and/or windows where warm air may be entering. | |
| The cooling coils are frozen. | See “The Air Conditioner Is Freezing Up” below | |
| The Air Conditioner Is Freezing Up | Ice is blocking the airflow. | Turn off the unit and allow it to thaw until the ice has melted, then operate on a higher fan speed. If this continues to occur, contact customer service for additional help. |
| The Remote Control Is Not Working |
Batteries are inserted incorrectly. | Check that the batteries are inserted in the correct direction. |
| Batteries are dead. | Replace the batteries and dispose of them in a responsible manner. | |
| Water Is Dripping From the Unit on the Outdoor Side | The weather is hot and humid. |
This is normal during periods of high humidity. NOTE: Do not drill a hole into the bottom of the metal base pan; doing so will reduce cooling performance. |
| Water Is Dripping Inside the Room | The air conditioner is not properly leveled. |
The air conditioner should slope slightly downward toward the outside. Level the air conditioner to provide a downward slope toward the outside to ensure proper drainage. See the “Installation Instructions” section. NOTE: Do not drill a hole into the bottom of the metal base pan; doing so will reduce cooling performance. |
| Water Collects in the Base Pan | Moisture removed from the air is collecting in the base pan. |
This is normal. Water that collects in the base pan will evaporate to the outside air. This helps with the unit's cooling process. NOTE: Do not drill a hole into the bottom of the metal base pan; doing so will reduce cooling performance. |
Before calling for assistance or service, please check the “Troubleshooting” section. It may save you the cost of a service call. If you still need help, follow the instructions below.
When calling, please know the purchase date and the complete model and serial numbers of your appliance. This information will help us to better respond to your request.
The electrical ratings for your air conditioner are listed on the model and serial number label. The model and serial number label is located on the right-hand side of the air conditioner cabinet.
Specific electrical requirements are listed in the “Electrical Requirements” sections. Follow the requirements for the type of plug shown in these sections.
Model BTUs − 6,000; 8,000; 10,000; 12,000; 15,000
All models −
6,000-8,000 BTU models −
10,000-15,000 BTU models −
Model BTUs − 18,000; 22,000; 24,000
This air conditioner must be grounded. This air conditioner is equipped with a power supply cord having a grounded 3 prong plug. To minimize possible shock hazard, the cord must be plugged into a mating, grounded 3 prong outlet, grounded in accordance with all local codes and ordinances. If a mating outlet is not available, it is the customer’s responsibility to have a properly grounded 3 prong outlet installed by a qualified electrical installer. It is the customer’s responsibility:
NOTE: Your air conditioner’s power supply cord may differ from those shown.
This air conditioner is equipped with a power supply cord required by UL. This power supply cord contains state-of-the-art electronics that sense leakage current. If the cord is crushed, the electronics detect leakage current and power will be disconnected in a fraction of a second.
To test your power supply cord:
NOTES:
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
Check that all parts are included in parts package.
NOTE: Not all parts are included with all models.
A. Foam seal with adhesive strip
B. Foam seal without adhesive strip
C. Sash lock x1
D. Lock frame x2
E. 1/2" screws x3
F. 3/4" screws x4
G. Side curtains x2
H. 3/8" screws x4
I. Top channel (appearance may vary)
J. 1/2" flathead bolt with locknut x4
K. Gasket x2
L. Top channel (appearance may vary)
M. Window support bracket x2
N. Side curtains x2
O. Side retainers x2
Other: AAA batteries x2
IMPORTANT: Observe all governing codes and ordinances.
Check the location where the air conditioner will be installed. Make sure you have everything necessary for correct installation.
The location should provide:
NOTE: Cabinet louvers must not be obstructed. Air must be able to pass freely through the cabinet louvers.
1. Measure and mark center line
Measure the width of the window opening (A). Mark the center line (B) of the window on the inside windowsill.
2. Attach upper foam seal
Attach the foam seal with adhesive strip to the bottom of the window sash.
Follow the steps in “Prepare Window Opening”. If possible, remove the storm window frame or other obstruction.
If the storm window frame or obstruction CANNOT be removed, a wood spacer will be required to ensure that the air conditioner slopes to the outside. This will allow condensation and rainwater to drain away. Make sure that drain holes or slots are not caulked or painted shut.
1. Measure size of spacer needed
Using a level and measuring tape, determine thickness of wood spacer needed to allow the air conditioner to slope downward slightly to the outdoors. The block should provide at least 1/2" (1.27 cm) of height above the obstruction.
2. Place block on windowsill
Place wood spacer on windowsill. Spacer should be at least the full width of the air conditioner cabinet.
1. Unpack the Air Conditioner
Remove Packaging Materials:
2. Install top channel
Place the top channel on the top of the air conditioner, lining up the holes in the top channel with the holes in the top of the air conditioner.
3. Attach screws
Using four 3/8" screws, attach the top channel to the air conditioner.
NOTE: Attach curtains to the air conditioner before placing the air conditioner in window.
1. Install side curtain
Holding the center of the right-hand side panel in one hand, pull the curtain open. Place the tabbed side of the side curtain in the track on the right-hand side of the air conditioner cabinet.
Slide the side curtain down the track, making sure to leave enough space to slip the top and bottom of the frame into the channels on the cabinet.
2. Insert curtain frame into channels
Slide the side curtain frame into the top channel and bottom channels of the air conditioner. Make slight adjustments until the panel sits securely inside the channels.
Repeat steps 1 and 2 for other side curtain and frame
IMPORTANT:
1. Position air conditioner in window
Using two or more people, place the air conditioner into the window opening so the bottom of the air conditioner frame is against the window sill. Tilt the back of the unit slightly downward to allow accumulated rain water to drain out.
2. Lower window sash into place
Lower the window sash behind the top channel to hold the air conditioner in place.
NOTE: Your model may differ from the one shown.
3. Extend side curtains
Extend side curtains out until they fit into the window channels.
4. Install side curtain brackets
Slide a side bracket over the bottom corner of each side curtain frame.
Using a 1/8" drill bit, drill a starter hole through the hole in the side curtain bracket and into the windowsill.
Secure each bracket to the windowsill with a 3/4" screw.
5. Install screws into window sash
Use a 1/8" drill bit to drill a starter hole through the holes in the top rail and the top corners of the side curtains into the window sash.
Secure with three 1/2" screws through the holes in the top rail and side curtain and into the window sash.
6. Secure lower sash
Attach the right angle sash lock with a 3/4" screw.
7. Install foam seal
Insert the foam seal without adhesive strip between the top of the lower window sash and the glass of the upper window.
Remove any remaining clear plastic film from the control panel and plastic front panel.
Reference file: Whirlpool WHAW101BW Energy Star 10,000 BTU 115V Window-Mounted Air Conditioner
Additionally, the document applies to other Whirlpool models: WHAW050BW, WHAW061BW, WHAW081BW, WHAW121BW, WHAW151BW, WHAW182BW, WHAW222BW, WHAW242BW