8 INSTALLING THE ELECTRIC ELEVATED COOKER
Hard wiring
1. To gain access to the terminal block, remove the
small rear panel by unscrewing the two screws.
2. Fit wires through the hole in the base using the
appropriate gland to protect insulation of wires
from the hole edge.
3. Set the length of wiring from the gland to terminal
block, ensuring length is sufficient but not excessive.
4. Make connections to terminals.
5. Replace rear panel.
A2
A1
N
INSTALLING THE ELECTRIC ELEVATED COOKER (CONTINUED)
Electric wiring requirements
The cooker MUST be installed in compliance with:
Wiring connections in AS/NZS3000 wiring rules.
Local regulations, municipal building codes and other
statutory regulations.
Data plate – Gives information about the rating and
is located behind the bottom of the oven door.
For New Zealand only: The cooking range must be
connected to the supply by a supply cord fitted with
the appropriately rated plug that is compatible with the
socket-outlet fitted to the final sub-circuit in the fixed
wiring that is intended to supply this cooking range.
See table below:
MODEL
CURRENT
RATING
(AMPS)
WIRE
SECTION
(MM
2
)
MINIMUM
TEMP
RATING
(°C)
WDE135WA 50 6 75
WDE147WA 50 6 75
A functional switch MUST be provided near the
appliance in an accessible position (AS/NZS3000 –
Clause 4.7.1).
Wiring MUST be protected against mechanical failure
(AS/NZS3000 – Clause 3.9).
Disconnection in the fixed wiring must occur in
accordance with the AS/NZS3000 Wiring Rules.
The cooker MUST be properly earthed.
This product has passed the insulation resistance
test after manufacture. If the resistance reading is low
at installation, it is probably caused by moisture from
the atmosphere being absorbed by the elements
after the range has been produced. (Pass at 0.01MΩ
AS/NZS 3000 Wiring Rules Clause 8.3.6.2)
When connections are made to a multiphase
230/240V supply, the bridge piece MUST be removed
from between the active connections.
If the supply cord is damaged, it must be replaced
by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
IMPORTANT: Before you cook in your new oven
it is important that the protective oils used in the
manufacture of the product be removed. Refer to
‘Before Operating your Appliance for the First Time’
in the Using The Oven section.
MODEL TOTAL kW A1 kW A2 kW
WDE135WA 10.1 4.1 6.0
WDE147WA 10.5 4.1 6.4
Rated power input