Useducttapetosealalljoints.Donotusescrewsto
securevent.Lintmaycatchonscrews.
Use4-inchdiameterheavymetalorflexiblemetalvent.
Donotkinkorcrushflexiblemetalvent.Itmustbefully
extendedtoallowadequateexhaustairtoflow.Check
ventafterinstallation.
Theexhaustventcanberoutedup,down,left,right,or
straightoutthebackofthedryer.Spacerequirements
arelistedlaterinthissection.
Usethestraightestpathpossiblewhenroutingthe
exhaustvent.Usethefewestnumberofelbowsand
turns.Allowasmuchroomaspossiblewhenusing
elbowsormakingturns.Bendventgraduallytoavoid
kinking.Removeexcessflexibleventtoavoidsagging
andkinkingthatmayresultinreducedairflow.
Good
Exhaust airflow
Maximum length of the exhaust system depends upon
the type of vent used, number of elbows, and the type
of exhaust hood. The maximum length for both heavy
and flexible metal vent is shown in the chart following.
See figure 1 for exhaust outlet location (at rear of
the dryer) and dimensions. Minimum side and rear
clearances appear on model and rating plate on back
of dryer.
Determining vent length
The maximum length of the exhaust system depends
upon:
The type of vent (heavy or flexible metal).
The number of elbows (90° turns) used.
To determine maximum vent length:
1. See the Exhaust Hood Type chart that matches your
type hood for the maximum vent lengths you can use.
Do not use vent runs longer than
specified in exhaust vent length chart,
Exhaust systems longer than specified will:
Shorten the life of the dryer.
Reduce performance, resulting in longer drying
times and increased energy usage.
2. Determine the number of elbows you will need.
3. In the column listing the type of metal vent you are
using (heavy or flexible), find the maximum length of
metal vent on the same line as the number of elbows.
EXHAUST HOODTYPE
Numberof _ "_ _-_
90° Turns
Maximum length of 4-inch diameter heavymetal vent.
0 64 ft. 64 ft. 58 ft.
1 54 ft. 54 ft. 48 ft.
2 44 ft. 44 ft. 38 ft.
3 35 ft. 35 ft. 29 ft.
4 27 ft. 27 ft. 21 ft.
Maximum length of 4-inch diameter flexible metal vent.
0 36 ft. 36 ft. 28 ft.
1 31 ft. 31 ft. 23 ft.
2 27ft. 27ft. 19ft.
3 25ft. 25ft. 17ft.
4 23ft. 23ft. 15ft.
NOTE: Check periodically to ensure that the outside
exhaust hood is not blocked.