6
INSTALLATION
FIG. 4
COMPLY WITH THE DIMENSIONS
(in mm)
A B C D E
2F (30) 285 473 59 59 100 min.
2F (45) 285 473 63.5 63.5 117 min.
4F (60) 553 473 63.5 63.5 173.5 min.
4F - 5F (70) 645 473 63.5 63.5 173.5 min.
5F (90) 833 475 62.5 62.5 73.5 min.
TECHNICAL INFORMATION
FOR THE INSTALLER
This appliance shall be installed only by authorised
personnel and in accordance with the
manufacturer’s installation instructions, local gas
fitting regulations, municipal codes, electrical wiring
regulations, AS 5601 - Gas Installation and any other
statutory regulations. Ventilation must be in
accordance with AS 5601 - Gas installation. In
general, the appliance should have adequate
ventilation for complete combustion of gas,
proper flueing and to maintain temperature of
immediate surroundings safe limits.
The wall and bench surfaces must be capable of
sustaining temperatures of 75 °C. All laminates,
fixing adhesive and surfacing materials should
be certified suitable for this temperature.
3) INSTALLING THE HOT PLATE
Check that the appliance is in a good condition after
having removed the outer packaging and internal
wrappings from around the various loose parts. In
case of doubt, do not use the appliance and contact
qualified personnel.
Never leave the packaging materials (cardboard,
bags, polystyrene foam, nails, etc.) within
childrens reach since they could become
potential sources of danger.
The measurements of the opening made in the top of
the modular cabinet and into which the hot plate will be
installed are indicated in either fig. 4. Always comply
with the measurements given for the hole into which
the appliance will be recessed (see fig. 4)
.
The appliance belongs to class 3 and is
therefore subject to all the provisions
established by the provisions governing such
appliances.
Any adjoining wall surface situated within 200 mm
from the edge of any hob burner must be a suitable
non-combustible material for a height of 150 mm for
the entire length of the hob. Any combustible
construction above the top of the burner and no
construction shall be within 450 mm above the top
of the burner. A minimum depth of 60 mm from the
top of the work surface must be provided for this
applaince.
CAUTION:
the installer shall test the appliance
before leaving. Test the safety
operation of the ignition system on all
burners individually and combined.
CAUTION:
do not place the glass directly on
the unit. The bottom of the hob
must rest on the unit.
Loading ...