INSTALLATION
Wiring connection for gas cooker
To allow for disconnection of the appliance after installation,
the plug must be accessible after installation�
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons
in order to avoid a hazard�
Gas connection
Read these points before connecting to the gas supply:
• The cooker inlet connection point has a ½" BSP external
thread� See diagram below�
• An NG regulator or a LPG test point fitting is supplied�
• It is recommended to fit the regulator or test point fitting
to the appliance connection point, then fit either hard
piping or a high level flexible connection (AS/NZS 5601�1
clauses 5�9 and 6�10�1�9) which is then attached to the
consumer hard piping�
• Ensure installation allows withdrawal of appliance�
Restraining device
anchor points
Gas connection
point
650mm
150mm
Operation on universal LPG/propane
1� The appliance inlet fitting provided MUST be orientated
so that the pressure nipple is accessible�
2� The inlet fitting has ½" BSP internal thread at the inlet
and outlet�
Operation on SNG
• If the cooker is to be used with SNG, then the grill burner
MUST be modified by the replacement of the shutter,
which fits into the throat of the grill burner�
• A conversion kit can be obtained by contacting the
Customer Care Centre�
Restraining Device
Anchor Points
Connection
Gas
Point
150mm
650mm
Grill shutter
WARNING
WARNING
Disconnect electric power before removing control panel�
1� Remove the control panel�
2� Remove the existing NG shutter securing screw (refer to
diagram above) and slide upwards to disengage from
grill burner�
3� Slide the SNG shutter into position and secure with
screws�
Testing the gas cooker
WARNING
WARNING
You MUST test the cooker after installation, before you hand
it over to the customer�
You MUST have a manometer and a connecting tube�
INSTALLATION