INSTALLATION
GAS TYPE NATURAL GAS UNIVERSAL LPG PROPANE
Supply pressure at inlet to appliance
regulator (if fitted)
1�13 (kPa)
Minimum
2�75* (kPa) 2�75* (kPa)
Operating pressure at
appliance test point
1�00 (kPa) 2�75 (kPa) 2�75 (kPa)
* If the regulator is placed upstream of the cooker inlet, as is normal for cookers operating on LPG, then the supply pressure and
operating pressure are the same�
The following table shows the injector sizes for each burner�
INJECTOR NATURAL GAS UNIVERSAL LPG PROPANE
Low heat burner 1�00 mm 0�55 mm 0�62 mm
Medium heat burner 1�35 mm 0�70 mm 0�82 mm
High heat burner 1�60 mm 0�90 mm 0�95 mm
Intense heat wok burner 1�75 mm 1�00 mm 1�00 mm
Grill – main injector 1�50 mm 0�82 mm 0�82 mm
Oven – main injector 1�60 mm 0�82 mm 0�95 mm
Oven – bypass screw 0�73 mm 0�45 mm 0�45 mm
Checking pipe size
To work out a suitable pipe size for connection use the information in this table�
NATURAL GAS UNIVERSAL LPG PROPANE
Configuration
STD
Hob
WOK Hob
STD
Hob
WOK
Hob
STD
Hob
WOK
Hob
Hourly gas consumption for
cooker
58�1MJ 60�2MJ 45�7MJ 48�2MJ 56�5MJ 58�3MJ
Also use information about the length of the run, number of
elbows, tees and bends, the available service pressure and
the supply requirements� AS/NZS 5601�1 will help you with this
matter�
Operation ON NG
• The appliance regulator MUST be orientated so that the
pressure nipple is accessible�
• The arrow showing the direction of flow MUST be
pointed correctly�
• The regulator has a ½” BSP internal thread at the inlet
and outlet�
Gas requirements
This appliance must be installed by an authorised person,
according to all codes and regulations of:
• AS/NZS 5601�1 (particular attention to clause 6�10�1
and figure 6�3 on page 97, and clause 6�10�1�11)
• Local gas fitting regulations, municipal building codes
and other statutory regulations�
Unpacking
When packaging is removed from product you will notice
there are several items nested in the packaging base�
The burner crowns, burner caps and trivets can be fitted to
the hob�
The regulator or test point fitting installation is described in the
front of the manual with UNPACKING�
The cookers come in three gas types:
Natural gas, Propane and Universal LPG� If the cooker is
required to use ULPG, a conversion kit can be obtained by
contacting the Customer Care Centre for details� Before
installation, check that the cooker is suitable for the gas supply
by looking at the data plate behind the bottom of the oven
door�
The following table shows the supply and operating pressures
for various supplies�
Restraining Device
Anchor Points
Connection
Gas
Point
150mm
650mm
NG Regulator
Gas flow
Pressure test
point
1/2" BSP
Internal thread
INSTALLATION