User's manual
(Suitable upper-arm circumference of the cuff: 22~32cm)
YE660B
Electronic Blood Pressure Monitor
Please read the user's manual closely!
YE660B
SYS
DIA
P/min
mmHg
mmHg
www.yuwell.com
JIANGSU YUYUE MEDICAL EQUIPMENT & SUPPLY CO.,LTD.
NO.1 Baisheng Road Development Zone, Danyang, Jiangsu
212300 CHINA
英文YE660B电子血压计说明书印刷要求
尺寸:210X142.5mm 色彩:准确、单色,层次分明
纸张:80克双胶纸 印后加工:对折装订
封面纸张:铜板纸,覆亚膜
Danger! Go
to hospital
as soon as
possible
Range
Systolic pressure
Diastolic pressure
Counter-
measures
Hypotension
≤100
≤60
Consult dr.
Ortho-arteriotony
100~140
60~90
Self check
Mild hypertension
140~160
90~100
Consult dr.
Medium hypertension
160~180
100~110
Consult dr.
Severe hypertension
180 110
mmHg mmHg

Wearing method
Sit straightly
2~3cm
Sitting posture
Measurement
Sit still for 5 minutes
before the measurement.
Keep the center of cuff and
heart at the same lever.
K e e p the u p p e r a r m
bareness or wearing thin
clothes.
Press the switch button, then start measuring.
Maintain the position during the measurement.
Relax while in the measuring process. It is unbefitting to
measure after meal, sporting, or in high mood.
Contents
Keep the center
of cuff and heart
at the same lever
The idealy height
difference between table
and chair is 25~30cm
The ideally height difference between table and chair is
25~30cm.
Keep the upper arm
bareness or wearing
thin clothes
1. Safety notes...............................................................................01
2. Application scope and attention items................................02
3. Features and technical parameters......................................03
4. Structure & Operating instructions......................................05
5. Measurement method.............................................................08
6. Other fuctions...........................................................................13
7. Common questions...................................................................18
8. Common faults and trouble shooting...................................21
9. Maintenance .............................................................................23
Wind the cuff around the upper arm. (As shown in the picture)
Keep the lower edge of the cuff at the position above 2-3cm
to the elbow joint and keep the air inlet which insert to the
cuff at the inside of arm.
英文YE660B电子血压计说明书印刷要求
尺寸:210X142.5mm 色彩:准确、单色,层次分明
纸张:80克双胶纸 印后加工:对折装订
封面纸张:铜板纸,覆亚膜
Danger! Go
to hospital
as soon as
possible
Range
Systolic pressure
Diastolic pressure
Counter-
measures
Hypotension
≤100
≤60
Consult dr.
Ortho-arteriotony
100~140
60~90
Self check
Mild hypertension
140~160
90~100
Consult dr.
Medium hypertension
160~180
100~110
Consult dr.
Severe hypertension
180 110
mmHg mmHg

02
Safety notes
Symbols
Application scope and attention items
Range of application
Attention items
Caution: Pay attention to the following points when
measuring or it may cause the incorrect results.
Sit still for 5 minutes before measuring to ensure quiet and
stable mode.
Do not take the measurement while standing, walking or
having body pressed.
Do not take the measurement after smoking, drinking wine
or coffee (black tea).
Do not take the measurement after sport or bath.
Do not speak or move while measuring.
Do not move, shake arm or bend fingers while measuring.
Do not take the measurement at extreme temperature
condition or the varied severely environment.
The monitor is used for measuring blood pressure of human
body(adult older than 12,not suitable for new born baby)!
This monitor is suitable fordaily healthcare. People can measure
blood pressure anytime and anywhere.
Contraindication:None
01
Symbol
Description
Attention! It might cause damage
Prohibited
Obligatory
Type BF application part
Class II device
Consult the manual
Keep Upright
Fragile
Keep Dry
Safety and environmental protection
use periodFor 10 years
英文YE660B电子血压计说明书印刷要求
尺寸:210X142.5mm 色彩:准确、单色,层次分明
纸张:80克双胶纸 印后加工:对折装订
封面纸张:铜板纸,覆亚膜
Danger! Go
to hospital
as soon as
possible
Range
Systolic pressure
Diastolic pressure
Counter-
measures
Hypotension
≤100
≤60
Consult dr.
Ortho-arteriotony
100~140
60~90
Self check
Mild hypertension
140~160
90~100
Consult dr.
Medium hypertension
160~180
100~110
Consult dr.
Severe hypertension
180 110
mmHg mmHg

03 04
Features and technical parameters
Features and technical parameters
Features
Technical parameters
Large-scale LCD with date and time display.
Automatical stored, 74 groups of memory.
Average value display of 3 times measurement.
Power off in 2 minutes without operation.
Displaying: LCD digital display
Measuring method: Oscillating mensuration
Measuring range:
Pressure measurement range:0~300mmHg
Pulse: 40~200 times/min
Precision:
Pressure: within ±3mmHg
Pulse: within ±5% of reading value
Working system: Continuous operation
Electric classification: Class II, type BF application part
Pressure sensor: Semiconductor pressure sensor
Pressurization: Automatic pressurize
Depressurization: Automatic air releasing
Power: 4 AA batteries or 5V/1A DC power
Weight: 252g
Suitable upper-arm circumference: 22~32cm
Dimension: Approximately L120.5mm×W100mm×H69.3mm
Working temperature: +5℃~+40℃
Relative humidity: 15%~80%RH
Working atmosphere pressure: 80kPa~105kPa
Transport and storage temperature: -20℃~ +55℃
Transport and storage relative humidity:15%~80%,
no condensation
Transportation and storage atmosphere pressure:
80kPa ~ 105kPa
Operation environment
Avoid electromagnetic interference, violent shock and noise
environment.
There is the potentia risk of radio frequency interference
between the device and other devices. If there is, please find
out the problems and take the following measures:
(1) Turn off the device, and turn on again,
(2) Change the direction of the device,
(3) Keep the product away from the interferential devices.
Operation and storage conditions
Attachments
User's manual, Warranty card, 4 AA batteries
Radio frequency interference
英文YE660B电子血压计说明书印刷要求
尺寸:210X142.5mm 色彩:准确、单色,层次分明
纸张:80克双胶纸 印后加工:对折装订
封面纸张:铜板纸,覆亚膜
Danger! Go
to hospital
as soon as
possible
Range
Systolic pressure
Diastolic pressure
Counter-
measures
Hypotension
≤100
≤60
Consult dr.
Ortho-arteriotony
100~140
60~90
Self check
Mild hypertension
140~160
90~100
Consult dr.
Medium hypertension
160~180
100~110
Consult dr.
Severe hypertension
180 110
mmHg mmHg

YE660B
SYS
DIA
P/min
mmHg
mmHg
0605
Structure Structure
Main part
Dispaly
The start button
The memory
button
Battery cover
Plug port
Dispaly
Time
Date
Systolic pressure
Diastolic pressure
Pulse
Storage number
Air-releasing sign
Air-filling sign
Storage sign
Heart beating sign
Low power sign
Cuff
Suitable upper-arm circumference: 22cm~32cm
Air tube
Air plug
Cuff
2~3cm
22~32cm
kPa unit
英文YE660B电子血压计说明书印刷要求
尺寸:210X142.5mm 色彩:准确、单色,层次分明
纸张:80克双胶纸 印后加工:对折装订
封面纸张:铜板纸,覆亚膜
Danger! Go
to hospital
as soon as
possible
Range
Systolic pressure
Diastolic pressure
Counter-
measures
Hypotension
≤100
≤60
Consult dr.
Ortho-arteriotony
100~140
60~90
Self check
Mild hypertension
140~160
90~100
Consult dr.
Medium hypertension
160~180
100~110
Consult dr.
Severe hypertension
180 110
mmHg mmHg

0807
Wrong postures
Bend down or body
bend forward.
Sit with legs crossed.
Sit on a sofa.( Belly
pressure may increase
the blood pressure)
Put the arm on low
table.( May increase the
blood pressure )
Install the batteries
properly
Operating instructions
Battery installation
Open the battery cover of blood
pressure monitor and install four AA
batteries properly.
If it appears " ", please remove old
batteries and replace with new
batteries.
Please take out the batteries if the
monitor is not used for a long term(
over three months). Properly dispose
the waste batteries to avoid the
pollution of the environment.
NOTE: 5V/1A DC external power can be
connected to the monitor.
Open the battery
cover
Close the battery
cover
Cuff connection
Low power sign
Plug the air plug of the cuff into the
left side port of the monitor, as the
following picture.
Correct measuring postures
The idealy height
difference between table
and chair is 25~30cm.
Sit straightly
Measurement method
Keep the upper arm
bareness or wearing
thin clothes
Keep the center
of cuff and heart
at the same lever
YE660B
SYS
DIA
P/min
mmHg
mmHg
2~3cm
22~32cm
英文YE660B电子血压计说明书印刷要求
尺寸:210X142.5mm 色彩:准确、单色,层次分明
纸张:80克双胶纸 印后加工:对折装订
封面纸张:铜板纸,覆亚膜
Danger! Go
to hospital
as soon as
possible
Range
Systolic pressure
Diastolic pressure
Counter-
measures
Hypotension
≤100
≤60
Consult dr.
Ortho-arteriotony
100~140
60~90
Self check
Mild hypertension
140~160
90~100
Consult dr.
Medium hypertension
160~180
100~110
Consult dr.
Severe hypertension
180 110
mmHg mmHg

YE660B
SYS
DIA
P/min
mmHg
Press the [ ] button
to start measuring
1009
2-3cm
Quick instructions for measuring
Measurement methodMeasurement method
The use of cuff
Tips
Both arms can be measured.
Encircle the cuff on upper-arm
with the air plug pointed to the
forearm. Keep the lower edge of
the cuff at the position above
2-3cm to the elbow joint and
keep the air inlet which insert to
the cuff at the inside of arm.
Strain the cuff and stick.
Cuff should be encircled the
arm comfortably without space
between the cuff and arm,
avoiding too tightness or
looseness.
Flat the arm on the table with
palm up and sit straightly. Keep
the center of cuff and heart at
the same lever. Make sure
there's no bended of the air
tube.
Place the cuff on the table, the
sticking side face down, then make
the cuff go though the metal ring.
Don't eat, smoke,drink, take bath or any high impact sport half
an hour before measuring. Measurements shall be taken at the
same time every day.
Please confirm the cuff, air plug and air tube are firmly
connected, and make sure air plug is plugged into the left side
port of the monitor.
Keep the upper arm bareness or wearing thin clothes.
Sit straightly with feet flatted on the floor and encircle the
cuff around the arm. Flat the arm on the table with palm up.
Keep the center of cuff and heart at the same lever. Sit still
for 5 minutes before the measurement.
The stateinflated
The screen shows " " when pressed
the [ ] button, which means the
system is in zeroing test. It will show
" " several seconds later and the air
inflation starts. (When using external
power, the screen menu will be all
light, then press the [ ] button to
measure).
The m onitor starts measurin g
automatically after inflation finished,
and the measuring sign " " starts to
flicker, pressure release value starts
to decrease gradually. Please maintain
英文YE660B电子血压计说明书印刷要求
尺寸:210X142.5mm 色彩:准确、单色,层次分明
纸张:80克双胶纸 印后加工:对折装订
封面纸张:铜板纸,覆亚膜
Danger! Go
to hospital
as soon as
possible
Range
Systolic pressure
Diastolic pressure
Counter-
measures
Hypotension
≤100
≤60
Consult dr.
Ortho-arteriotony
100~140
60~90
Self check
Mild hypertension
140~160
90~100
Consult dr.
Medium hypertension
160~180
100~110
Consult dr.
Severe hypertension
180 110
mmHg mmHg

If the measurement need stoping for uncomfortableness or
other reasons, please press the [ ] button, the measurement
will stop immediately and air releases fast. Take off the cuff
manually if the [ ] button is not working.
1211
Measurement methodMeasurement method
Measuring state
The measuring sign " "stops flickering
when the measurement is finished, and
the monitor will show the systolic blood
pressure, diastolic blood pressure, and
heart rate, and also quickly release the air
in cuff automatically.
If once more measuring is needed, please
press the [ ] button twice. The monitor
Tips
If continuous measurement is needed, the interval should be
more than 2~3 minutes between two measurements.
Emergency stop during measurement
Press the [ ] buton to stopped
measurement immediately
Warning: Upper limit pressure of air inflation is 300mmHg.
Don't keep the inflated state for a long time to protect the
arm.
will power off automatically in 3 minutes with no operation
the position during the measurement and don't speak or
move the body or hand.
NOTICE
This product can automatically record the data of each
measurement for at most 74 times (including time, date, blood
pressure and pulse). Press the [ ] button to read.
m
YE660B
SYS
DIA
P/min
mmHg
英文YE660B电子血压计说明书印刷要求
尺寸:210X142.5mm 色彩:准确、单色,层次分明
纸张:80克双胶纸 印后加工:对折装订
封面纸张:铜板纸,覆亚膜
Danger! Go
to hospital
as soon as
possible
Range
Systolic pressure
Diastolic pressure
Counter-
measures
Hypotension
≤100
≤60
Consult dr.
Ortho-arteriotony
100~140
60~90
Self check
Mild hypertension
140~160
90~100
Consult dr.
Medium hypertension
160~180
100~110
Consult dr.
Severe hypertension
180 110
mmHg mmHg

1413
Other functionsOther functions
Time and date setting
2. Press the button of [ ] once to set the year. Every time
press to increase one year.
3. Press the button of [ ] after the year was set to switch
to set the month, date, hour and minute.
m
Press the [ ] and [ ] for at
least 3 seconds at the same time
m
m
Long press the [ ] button
to enter the quick setting mode
Press the [ ] button to
switch
The BP is different in different time period in the same day.
The BP monitor can record the values automatically for
convienient monitoring and management.
Turn on the monitor after installing new batteries, the
time/date displays the last setting data, for example: 1-25
13:43, that is month-date-time, the year is elided. Please
operate as following steps to reset the time and date. (For
example: input date is 2016-1-25, time is 13:43).
1. Turn on the monitor, press
the [ ] and [ ]for at
least 3 seconds at the same
time to set the year, then
the last two numbers of the
year begin to flicker(the first
two numbers are elided) ,
for example 2016 displays
as 16.
m
YE660B
SYS
DIA
P/min
mmHg
YE660B
SYS
DIA
P/min
mmHg
YE660B
SYS
DIA
P/min
mmHg
After finishing the time and date setting,press [ ] button
to enter the unit setting. And then press the [ ] button to
switch units. When the screen displays [ kPa ], [ m ]
Otherwise, the unit is mmHg. Press [ ] to
finish setting.
After finishing unit setting, press the [ ] button to shut
down.
press to
set the unit to kPa.
Unit setting
英文YE660B电子血压计说明书印刷要求
尺寸:210X142.5mm 色彩:准确、单色,层次分明
纸张:80克双胶纸 印后加工:对折装订
封面纸张:铜板纸,覆亚膜
Danger! Go
to hospital
as soon as
possible
Range
Systolic pressure
Diastolic pressure
Counter-
measures
Hypotension
≤100
≤60
Consult dr.
Ortho-arteriotony
100~140
60~90
Self check
Mild hypertension
140~160
90~100
Consult dr.
Medium hypertension
160~180
100~110
Consult dr.
Severe hypertension
180 110
mmHg mmHg

1615
m
m
2. Delete the recorded data.
Long press both the [ ] button and [ ] button utill the
"Clr1" sign to delete the recorded data. Shown as the following
picture:
m
m
Other functionsOther functions
NOTE: This operation may delete all the rocorded data.
Press the [ ] button
Show the
average value
The 3rd group
of memory
1. Press the [ ] button to display the latest recorded values.
m
m
A. Press the [ ] button to display the average value of the
latest 3 times measurement.
B. Repress the button to display the 1st group of memory, the
serial number is displayed as "1" to "74". "1" is the latest
group and the "74" is the earliest one.
If the memory capacity is full, the 74th data may be
replaced by the 73rd.
C. Read the recorded data by pressing the [ ]button as the
st
sequence: "1", "2" , …… "74"(max). Then return to the 1 .
D. Keep pressing the [ ] button to search the recorded
data quickly.
Tip
YE660B
SYS
DIA
P/min
mmHg
YE660B
SYS
DIA
P/min
mmHg
Static mode
The function is designed for professionals to proof test with
standard pressure meter .
NOTE: Ordinary users need not know this function, also do
not use this function. Our company is not responsible for any
consequences caused by inappropriate operation.
The BP monitor can record the data as BP values, pulses,
time and data automatically for convienient monitoring and
management.
Memory function
英文YE660B电子血压计说明书印刷要求
尺寸:210X142.5mm 色彩:准确、单色,层次分明
纸张:80克双胶纸 印后加工:对折装订
封面纸张:铜板纸,覆亚膜
Danger! Go
to hospital
as soon as
possible
Range
Systolic pressure
Diastolic pressure
Counter-
measures
Hypotension
≤100
≤60
Consult dr.
Ortho-arteriotony
100~140
60~90
Self check
Mild hypertension
140~160
90~100
Consult dr.
Medium hypertension
160~180
100~110
Consult dr.
Severe hypertension
180 110
mmHg mmHg

Press the [ ] button after installing the batteries,then the
screen shows the " " sign which means system is in reset
testing mode. Several seconds later the screen shows the " "
sign, the pump start inflating as the same time. The
disappearance of the " " sign means the operation completed.
Then press the [ ] button to stop inflating and take out the
batteries to enter the next step.
NOTE: It should be reset the system before entering the static
mode, or may cause inaccurate proof test.
1817
(1)After entering the static mode, if the screen still doesn't
show the " " sign, please reset the sysytem again. Please
contact the distributor if the problem cann't be solved.
(2)After entering the static mode, the monitor will automatic
power-off in 4 minutes without any operation.
2. Enter the static mode
1. Reset the system
Press an hold the [ ] button,
install the batteries at the same time,
wait for about 3 seconds, release the
[ ]button when heard a click, then
the screen shows " ", date and
time, this moment the system has
been reseted and entered to the
static mode. Proof test can be started.
m
m
Common questions of blood pressure measurementOther functions
YE660B
SYS
DIA
P/min
mmHg
Tip
1. What is blood pressure?
Blood pressure is the force exerted by blood against the walls of
the arteries. Systolic pressure occurs when the heart contracts.
Diastolic pressure occurs when the heart expands. Blood
pressure is measured in millimetres of mercury (mmHg). One's
natural blood pressure is represented by the fundamental
pressure, which is measured first thing in the morning while one
is still at rest and before eating.
2. What is Hypertension and how is it controlled?
Hypertension, an abnormally high arterial blood pressure, if left
unattended can cause many health problems including stroke
and heart attack. Hypertension can be controlled by altering
lifestyle, avoiding stress, and with medication under a doctor's
supervision.
To prevent Hypertension or keep it under control: Do not smoke,
exercise regularly, reduce salt and fat intake, have regular
physical checkups, maintain proper weight.
3. Why measure Blood Pressure at home?
Blood pressure measured at a clinic or doctor's office may cause
apprehension and can produce an elevated reading, 25~30
mmHg higher than that measured at home. Home measurement
reduces the effects of outside influences on blood pressure
readings, supplements the doctor's readings and provides a
more accurate, complete blood pressure history.
英文YE660B电子血压计说明书印刷要求
尺寸:210X142.5mm 色彩:准确、单色,层次分明
纸张:80克双胶纸 印后加工:对折装订
封面纸张:铜板纸,覆亚膜
Danger! Go
to hospital
as soon as
possible
Range
Systolic pressure
Diastolic pressure
Counter-
measures
Hypotension
≤100
≤60
Consult dr.
Ortho-arteriotony
100~140
60~90
Self check
Mild hypertension
140~160
90~100
Consult dr.
Medium hypertension
160~180
100~110
Consult dr.
Severe hypertension
180 110
mmHg mmHg

2019
Common questions of blood pressure measurement
4. W HO Blood Pressure Classification?
Standards to assess high blood pressure, without regard to age,
have been established by the world Health Organization (WHO), as
shown below:
5. Blood pressure variations?
An individual's blood pressure varies greatly on a daily and
seasonal basis. It may vary by 30 to 50 mmHg due to various
conditions during the day. In hypertensive individuals variations
are even more pronounced. Normally, the blood pressure rises
while at work or play and falls to its lowest levels during sleep.
So do not be overly concerned by the results of one
measurement.
Note: There is no definition about hypopiesia, and generally
SYS (systolic pressure) less than 90mmHg or DIA (diastolic
pressure) less than 60mmHg is called hypotension.
Take measurements at the same time every day using the
procedure described in this manual to get to know your
normal blood pressure. Regular readings give a more
comprehensive blood pressure history. Be sure to note date
and time when recording your blood pressure. Consult doctor
to interpret the blood pressure data.
6. When is the best time to measure blood pressure?
After urination, before breakfast in the morning.
Before sleeping at night.
Before taking medicine.
Please keep a stable body state and mind every time
measuring. We suggest taking measurements at a same time
every day.
Common questions of blood pressure measurement
kPa/mmHg kPa/mmHg
12.0~18.5kPa
90~139mmHg
18.7~21.2kPa
140~159mmHf
12.0~13.2kPa
90~99mmHg
21.3~23.9kPa
160~179mmHg
13.3~14.5kPa
100~109mmHg
≥24.0kPa
≥180mmHg
≥14.7kPa
≥110mmHg
8.0~11.9kPa
60~89mmHg
英文YE660B电子血压计说明书印刷要求
尺寸:210X142.5mm 色彩:准确、单色,层次分明
纸张:80克双胶纸 印后加工:对折装订
封面纸张:铜板纸,覆亚膜
Danger! Go
to hospital
as soon as
possible
Range
Systolic pressure
Diastolic pressure
Counter-
measures
Hypotension
≤100
≤60
Consult dr.
Ortho-arteriotony
100~140
60~90
Self check
Mild hypertension
140~160
90~100
Consult dr.
Medium hypertension
160~180
100~110
Consult dr.
Severe hypertension
180 110
mmHg mmHg

2221
Common fault and trouble shooting Common fault and trouble shooting
Common fault
Solutions
It doesn't work after
pressing the [ ] button
with batteries installation
Check the batteries are installed
correctly
Replace new batteries
Multiple occurrences of
measuring failure, or
measured value is low
(or high)
Check the connection and winding
of cuff
Check if the cuff winded too tight
or too loose. Take off your clothes
if rolled too tight
Please ensure a quiet, relaxed body
state. Deep breathing to relax
yourself before measurement
Please read the "blood pressure
variations"carefully
The monitor is in good
condition, but the each
measuring result are
different
The value is different
from that measured at a
clinic or doctor's office
Pump works, but the
pressure doesn't rise
Check whether the cuff has
connected well
Write down the value every day,
and consult a doctor
Warning: If the situations cannot be solved or unexpected
problem happens, please consult the local distributor.
Fault cause
Wrong
indication
Solution
Err 4
Err 5
Err 6
Err 7
Err 8
Showing low
voltage icon
" "
Unable to measure
pressure
Pressurizing error
Fasten cuff correctly
before measurement
Check if there is air
leakage from the cuff
Pressurizing error
caused by arm or
body motion
Keep arm and body still
and measure again
Cuff is too lose or
fall off
Fasten cuff tightly
Pressure exceeds the
maximum value
(300mmHg)
Battery is low
Measure again please
Replace new batteries
The table below shows the possible fault displaying icon,
possible reason, and solutions.
英文YE660B电子血压计说明书印刷要求
尺寸:210X142.5mm 色彩:准确、单色,层次分明
纸张:80克双胶纸 印后加工:对折装订
封面纸张:铜板纸,覆亚膜
Danger! Go
to hospital
as soon as
possible
Range
Systolic pressure
Diastolic pressure
Counter-
measures
Hypotension
≤100
≤60
Consult dr.
Ortho-arteriotony
100~140
60~90
Self check
Mild hypertension
140~160
90~100
Consult dr.
Medium hypertension
160~180
100~110
Consult dr.
Severe hypertension
180 110
mmHg mmHg

23
Maintenance
Please observe the following items to protect the device and
ensure the accuracy of measurement.
We advice to calibrate the monitor according to local
laws and regulations.
Tips!
Please store the monitor and accessories properly after use.
Do not place the monitor and accessories in high
temperature, moisture, dust, or exposure to sunshine.
The cuff contains an airbag inside, please care in applications,
do not fold, pull or twist it.
Do not disassemble or repair the device without
authorization.
Do not replace the parts without authorization.
Please clean the monitor with soft dry cloth. If it's necessary,
please use wiped soft cloth with water or neutral detergent
before cleaning by soft dry cloth.
Using absorbent cotton to wipe gently with rubbing alcohol,
disinfection of the machine when it necessary. Do not use
detergent to clean.
Do not let water seep into the device.
英文YE660B电子血压计说明书印刷要求
尺寸:210X142.5mm 色彩:准确、单色,层次分明
纸张:80克双胶纸 印后加工:对折装订
封面纸张:铜板纸,覆亚膜
Danger! Go
to hospital
as soon as
possible
Range
Systolic pressure
Diastolic pressure
Counter-
measures
Hypotension
≤100
≤60
Consult dr.
Ortho-arteriotony
100~140
60~90
Self check
Mild hypertension
140~160
90~100
Consult dr.
Medium hypertension
160~180
100~110
Consult dr.
Severe hypertension
180 110
mmHg mmHg