.com
Portable Air Conditioner
Product ID. Q2U2U
Scan for Support
support@garvee.com

Model: FDP35-3037ZR5
Mobile
Local Air Conditioner

Install Exhaust Hose and Adapter
5
7
8
9
12
Using Information
13
Technical specifications
14
Accessories and Select the best location
Installation
11
Installation

Caution,risk of fireCaution,risk of fire
1
–the maximum refrigerant charge amount: 200g
Do not pierce or burn.
Be aware that refrigerants.
May not contain an odour.
using your air conditioner,follow these basic precautions:
1.Plug into a grounded 3 prong outlet.
2.Do not remove ground prong.
3.Do not use an adapter.
4.Do not use an extension cord.
5.Unplug air conditioner before servicing.
6.Use two or more people to move and install air conditioner.
11.This appliance is not intended for use by persons(including children)with reduced physical,sensory or mental capabilities,
or lack of experience and knowledge,unless they have been given supervision or instruction concerning use of the
appliance by a person responsible for their safety.Young children should be supervised to ensure that they do not play with the appliance.
12.Correct Disposal of this product
This marking indicates that this product should not be disposed with other household wastes throughout
The EU.To prevent possible harm to the environment or human health from uncontrolled waste disposal,
Recycle it responsibly to promote the sustainable reuse of material resources.To return your used device,
Please use the return and collection , systems or contact the retailer where the product was purchased.They
13.Do not use means to accelerate the defrosting process or to clean,other than those recommended by the manufacturer.
Recommended by the manufacturer.
example: open flames, an operating.
Gas appliance or an operating electric heater.
WARNING
To reduce the risk of fire,electrical shock or injury when
Can take this product for environmental safe recycling.
14.When the machine malfunctions, do not repair it yourself.Please contact a professional organization or a
professional trained maintenance personnel or a service organization recommended by the supplier for repair!.
7. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory
or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards involved.
8. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
9. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
10. The appliance shall be installed in accordance with national wiring regulations
The appliance shall be stored in a room without continuously operating ignition sources for
Thank you for choosing this mobile air conditioner to provide you and your family with all of the
“Home Comfort”requirements for your home,cottage or office.The appliance can be moved
From room to room within your home and set-up in just minutes.
It is a multi-functional room air exchanging,air-processing appliance,designed to offer you the
Functions of:Air Conditioning,Dehumidifying,Independent Fan and Heating.The external static
Pressure at which the appliance was tested is 0 Mpa.
This manual will provide you with valuable information necessary for the proper care and maintenance
For your new appliance.Please take a few moments and read the instructions thoroughly.If properly
Maintained,your appliance will give you many years of trouble free operation.
1.All wiring must comply with local and national electrical codes and be installed by a qualified electrician
If you have any questions regarding the following instructions,contact a qualified electrician.
2.Check available power supply and resolve any wiring problems before installation and operation of this unit.
3.For your safety and protection,this unit is grounded through the power cord plug when plugged into
a matching wall outlet.If you are not sure whether the wall outlets in your home are properly grounded,
please consult a electrician.If supply cord is damaged,it must be replaced by the manufacture,its
service agent or similarly qualified persons in order to avoid a hazard.

4
Front
5
1
2
3
7
8
6
Back
The figures in this manual are based on the external view of a standard model.
Consequently, the shape may differ from that of the air conditioner you have selected.
Identification of parts
1
2
3
4
5
6
7
8
Control panel
Cold air outlet
Signal receptor
Remote controller
Transport handle
Evaporator air intake
Continuous drainage outlet
Air outlet hose
Identification of parts
2

Full water alarm
FAN
low、middle 、high Fan speed
Dehumidify and Fan mode
6.
Press this button to set swing .
Swing
C by 1
a) Plug in,then the unit beeps once.
E
E
Timer button
Swing button
On/Off button
and Fan Model operation.
Power
3
mobile
“ ”
“ ”
“ ”
“ ”
Timer/Temperature up button
Timer/Temperature down button
Mode button
Speed button
Aatomatic、Cool、
3
mobile

≥
=
4.
22
<
23
4

55

How to install batteries
Slide the cover to open
Be sure the direction
is correct
Inserting batteries
1. Open the back cover, ;and take off the isolating film on the batteries
2. Put the batteries inside the slot,
with anode and cathode in right directions;
3. Put on the back cover.
Notices:
1). The anode and cathode of the batteries must be corresponding to the signs of
“+” and “-” on the remote control;
2). Do not use new battery cells together
with run-down cells;
3). For long time no use,
take out the batteries;
4). To prevent environmental pollution,
take out the used batteries and dispose
safely and appropriately.
6
distance of up to 5m (16.4 feet) when pointing
at singal receptor of the air conditioner

Special reminder: there is condensing water recycling hidden within this unit. The
condensing water is partly kept recycling between the condenser and the water plate.
When the water level rises to the upper level, the float switch
and water full indicator (E4) lights on to remind draining water. Please cut off the
power supply, move the appliance to a suitable place, remove the drain plug, drain water
completely. after the drain, re-install the plug, or the appliance may leak and make your room wet.
7

8

9
“E4”

10
Before claiming repair, check the machine as follows:
The evaporator oil pipe sensor
fails or damaged.
Replace the evaporator coil pipe
sensor.
Water-full warning.
Drain out the water.
Failures
Causes
Solutions
Machine fails to start up.
Power supply failure:
1. Not plugged;
2. Plug or socket damaged;
3. Fuse broken.
1. Plug in;
2. Replace the power cord or
socket;
3. Replace the fuse by service
provider (Specification:
3.15A/250VAC).
Machine automatically
stops.
TIMING shut down or set
temperature reached.
Restart or wait for auto-switch.
No cold air under
COOLING mode.
1. Room temperature lower
than set temperature;
2.Machine enters into
anti-frost protection.
1. This is a normal
phenomenon, the machine will
auto-switch while the room
temperature is higher than the
set temperature;
2. The machine will auto switch
after anti-frost protection is
over.
LED displays failure
code “E2”
Room temperature sensor
fails or damaged.
Replace the room temperature
sensor.
LED displays failure
code “E3”
LED displays failure
code “E4”

4
Installation
2
1
3
5 Baffle Plate
5
1 Air exhaust duct
3 Window exhaust adapter 4 Remote control
2 Connector of air exhaust duct
11
Installation accessories

How to connect the connectors to the Air exhaust duct
1.Extend the air exhaust duct by drawing out the two ends of the duct.
2.Screw the air exhaust duct into the connector of air exhaust duct.
3.Screw the connector of window into the plastic connector.
4.Connect the connector of air exhaust duct to the unit.
12

Warranty Information
The manufacturer provides warranty in accordance with the legislation of the
customer's own country of residence, with a minimum of 1 year (Germany: 2
years), starting from the date on which the appliance is sold to the end user.
The repairs under warranty may only be carried out by an authorized service
centre. When making a claim under the warranty, the original bill of purchase
(with purchase date) must be submitted.
The warranty will not apply in cases of:
-Normal ware and tear
-Incorrect use, e.g. overloading of the appliance, use of non-approved
accessories
-Use of force, damage caused by external influences
-Damage caused by non-observance of the user manual, e.g.connection to
an unsuitable mains supply or non-compliance with the installation instructions
-Partially or completely dismantled appliances
Using Information
Cautions
Keep the unit at least 1 meter away from TV or radios to avoid electromagnetic
interference.
Do not expose the unit under direct sun light to avoid surface color fading.
Do not tilt the unit for more than 35° or upside-down while transporting.
Place the unit on a flat surface with less than 5° inclination.
The unit operates more efficiently in certain room locations (see Technical
Specifications).
Empty the condensed drainage pan before putting the unit in storage to
prolong the unit lifetime at the end of the season.
Do not use chemical solvents (e.g. Benzene, alcohog-glazer) to clean the unit
surface to avoid scratching, damaging the surface.
Make sure to cut off the power before disassembing or installing the air-inlet
fence.
Please empty the water from the water tank, if you want to move the machine.
The battery must be removed from the appliance before it is scrapped
The battery is to be disposed of safely
The plug must be removed before cleaning, maintaining or filling the appliance
13

Dimensions
W×D×H
Body(mm)
Package(mm)
Rated Energy Efficiency Ratio(EER )
rated
Global Warming Potential (kg CO )
2
Model
Cooling Capacity
Dehumidifying Capacity (l/h)
Cooling Inpuy Power/Current
Air Flow Volume (m³/h)
RatedVoltage /Frequenc(V/Hz)
Sound Pressure Level ( dB (A) )
Heatling Capacity
Heatling Inpuy Power/Current
EER
rated
Class
Net Weight (Kg)
Refrigerant
Applying Space(m²)
Miniature Fuse
1.2 l/h
220-240V~/50Hz
L
WA
:
65dB(A)
2.6
3
A
L
PA
1300W
:
54dB(A)
/6.0A
400m³/h
FDP35-3037ZR5
3500W
29Kg
440
X335X710mm
470X380X880mm
R290
18-23
m²
3.15A 250VAC
14
Technical specifications
Manufacturer: Ningbo Fuda Intelligent Technology Co., Ltd.
Address : No.1 Zhenhua Road ,Zhennan Village,Simen Town,315470
Yuyao ,Zhejiang Province,People's Republic of China
Web: http://www.fuda-china.com/

Limited Liability & Warning
No Unauthorized Modifications/Repairs: Do not modify or attempt to repair this product
unless you are an authorized technician. Unauthorized actions may create hazards and void
all warranties
Misuse & Non-Compliance: We are not liable for any injury, damage, or loss resulting from:
(a) misuse, abuse, neglect, or improper installation;
(b) failure to follow instructions or safety precautions;
(c) use of unauthorized parts/accessories;
(d) unauthorized modifications/repairs;
(e) accidents, natural disasters, or external causes.
If you doubt any step of installation or operation, stop using the product and contact
authorized service or the customer support.
LIMITACIÓN DE RESPONSABILIDAD Y ADVERTENCIA
Modificaciones o Reparaciones No Autorizadas: NO modifique ni intente reparar este
producto a menos que sea un técnico autorizado. Las acciones no autorizadas pueden
generar riesgos y anularán todas las garantías.
Uso Indebido e Incumplimiento: No asumimos responsabilidad alguna por lesiones, daños o
pérdidas que resulten de:
(a) uso indebido, abuso, negligencia o instalación incorrecta;
(b) incumplimiento de las instrucciones o precauciones de seguridad;
(c) uso de piezas o accesorios no autorizados;
(d) modificaciones o reparaciones no autorizadas;
(e) accidentes, desastres naturales o causas externas.
Si tiene dudas sobre algún paso de la instalación o el funcionamiento, deje de usar el
producto y póngase en contacto con el servicio técnico autorizado o con atención al cliente.