MeoWant MW-PA16 Pet Air Purifier for Home, Dual-sided Intake Air Purifier

Product's Documents

Below are documents related to this product, you can read online or download:
MW-PA16 photo

User Manual

This is the main product document for model MW-PA16.

The file format is pdf, 10 pages, you can download this manual here .

background
AIR
PURIFIER
User Manual
suppo@meowanthome.com
GET IN TOUCH?
Model: MW-PA16
DISTRIBUTOR
Shenzhen Guiyang Network Technology Co., Ltd
ADDRESS
1404K3, East Block, Shengtang Commercial Building,
Futian District, Shenzhen, China
Rev_1.1_EN
Made In China
Intertek
5030403
CM
background
CONTENT
01 02 03
USING
AIR
PURIFIER
04
CARE
AND
MAINTENANCE
05
TROUBLE-
SHOOTING
GUIDE
IMPORTANT
SAFETY
INSTRUCTIONS
Safety Instructions
Specications
01-03
01
03
EXPLORING
AIR
PURIFIER
In the Box
Control Function
LED Display
04-06
04
05
06
Setting Up
Replacing Filter
07-11
07
09
11-13 14-15
background
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE AND SAVE
FOR FUTURE REFERENCE
When using an electrical appliance, basic safety precautions should always be followed to
reduce the risk of re, electric shock, and/or inju to persons including the following:
•This appliance is not intended for use by persons (including children) with reduced physical, senso or mental capabilities, or lack of experience and
knowledge, unless they have been given supeision or instruction concerning the use of the appliance by person responsible for their safety.
•Close supeision is necessa when any appliance is used by or near children. Children should be supeised to ensure that they do not play with the
•DO NOT use the appliance with a damaged cord or plug or if it malfunctions, is dropped or damaged in any manner.
•DO NOT operate any fan with a damaged cord or plug. Discard fan or return to an authorized seice facility for examination and/or repair.
•DO NOT use an external power supply other than the one provided with the appliance. Use only the provided power adapter.
•DO NOT immerse the appliance, power cord or plug in water or other liquid.
•DO NOT touch or hold the plug or operate the control panel with wet hands.
•DO NOT let cord hang over edge of table or counter, or touch hot suaces.
•If the supply cord is damaged, it must be replaced by the manufacturer, its seice agent or similarly qualied persons in order to avoid a hazard.
INTENDED USE
ELECTRICITY SAFETY
•DO NOT use the lter as fuel or for similar purposes.
•DO NOT use the air purier in an enclosed space where ammable, combustible or explosive gases are present.
•Always place and use the air purier on a d, stable, level, and horizontal suace. Arrange the air purier and cord away from trac areas and where it will
not be knocked over.
•DO NOT expose to direct sunlight or other sources of sustained heat. Do not place near any heat sources such as radiators, heat registers, stoves, etc.
•DO NOT place the air purier directly below an air conditioner to prevent condensation from dripping onto the appliance.
•DO NOT place the air purier directly on or against soft furnishings, such as bedding or cuains, as this could cause the air purier to block the air inlet or
outlet.
•Keep indoors in a cool, d location. Reduce exposure to high temperature and humidity.
•DO NOT sit on or place any object on top of the air purier.
•DO NOT allow pets to chew on or swallow any pas. Cover or hide the power cord with care to prevent pets from biting.
•DO NOT allow anything to rest on the power cord. Do not plug in power adapter in an area where people or animals may walk or trip on cord.
•DO NOT run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances.
Arrange cord away from trac area and where it will not be tripped over.
RELATED TO USE
01 02
•DO NOT attempt to disassemble, repair, modify or replace any pa of the appliance. No user seiceable pas inside. All seicing should be peormed by
qualied personnel only.
•To reduce the risk of re, electric shock, or inju to persons, do not use replacement pas that have not been recommended by the manufacturer (e.g.,
pas made at home using a 3D printer).
•Always turn o and unplug the air purier before moving, opening the covers or changing the lter.
•Always turn o and unplug the air purier before cleaning, making any repairs or seicing, or whenever not in use. To disconnect, turn it o, then remove
the plug from the outlet. Do not pull on cord.
•Dispose of all packaging materials properly. Keep away from children and pets. Keep plastic bags away from babies and small children. Do not use in cribs,
beds, carriages or play pens.
WARNING
Always ensure the lters are properly
installed with plastic wrap removed
before use.
DO NOT cover or block the air inlets
or outlets in any manner. Allow at
least 8 in of clearance.
DO NOT inse ngers or any objects
through the grille or openings while
in operation.
appliance. Cleaning and user maintenance shall not be done by children unless they are older than 8 and supeised. Keep the appliance and its cord out
of reach of children.
•Use the appliance only for intended household purposes as described in this User Manual. Any other use not recommended by the manufacturer may
cause re, electric shock, or inju to persons.
•WARNING - To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan With Any Solid-State Speed Control Device.
background
03
04
•DO NOT attempt to disassemble, repair, modify or replace any pa of the appliance. No user seiceable pas inside. All seicing should be peormed by
qualied personnel only.
•To reduce the risk of re, electric shock, or inju to persons, do not use replacement pas that have not been recommended by the manufacturer (e.g.,
pas made at home using a 3D printer).
•Always turn o and unplug the air purier before moving, opening the covers or changing the lter.
•Always turn o and unplug the air purier before cleaning, making any repairs or seicing, or whenever not in use. To disconnect, turn it o, then remove
the plug from the outlet. Do not pull on cord.
•Dispose of all packaging materials properly. Keep away from children and pets. Keep plastic bags away from babies and small children. Do not use in cribs,
beds, carriages or play pens.
FOR HOUSEHOLD USE ONLY
READ AND SAVE THESE INSTRUCTIONS
Specications
Rated Voltage
Rated Power
Power Adapter
48W
EXPLORING AIR PURIFIER
In the Box
24V
Check if all pas and accessories are included. Contact us via email: suppo@meowanthome.com if there is any pa
missing or damaged.
Air Outlet
Control Panel
LED Display
Rear Cover
Power Adapter x1
(bundled at bottom)
HEPA Filter
with Pre-lter
Dust Sensor
Main Unit
Cable Slot
Power Po
Front Cover
HEPA Filter
with Pre-lter
Input: 100-240V~ 50/60Hz 1.0A
Output: 24V 2A
background
05 06
LED Display
Control Function
ON / OFF
•Press once to turn the air purier on (Auto
mode on by default).
•Press once again to turn the air purier o.
Auto Mode
•With air purier on, press to turn Auto mode on
or o.
•Once Auto mode is enabled, the air purier
automatically adjusts the fan speed based on
the air quality.
Sleep Mode
•With air purier on, press to turn Sleep mode on
or o.
•Once Sleep mode is enabled, the air purier
automatically runs at low fan speed with display
o. Press any button to wake up the display.
Fan Speed
With air purier on, press repeatedly to cycle
through fan speeds: P1 → P2 → P3 → P4 → P0
(Auto mode)→ P1...
Child Lock
With air purier on, press and hold for 3 seconds
to turn on or cancel child lock.
Auto OFF Timer
•With air purier on, press repeatedly to set a time
(0-12H) to turn o automatically.
•To cancel, set timer to 0H, or turn the air purier o.
Check / Reset Filter
•With air purier on, press once to check the lter
life. The lter life will display for 6 seconds.
•When the lter reaches its seice life (2000 hours),
button indicator and will ash red. Replace the
lter and reset the lter life by holding the button
for 6 seconds until three beeps are heard.
Air Quality
Indicator
Real-time
PM2.5 (μg/m³)
Child Lock
Auto OFF Timer
Filter Replacement
Reminder
(Flashes red when lter
is to be replaced)
Auto Mode
Air Quality Indicator Cha
PM2.5 (μg/m³)
007-079
080-149
150-199
200-500
P1
P2
P3
P4
Green
Yellow
Red
Excellent
Moderate
Poor
Indicator Color Air Quality Fan Speed
background
07 08
USING AIR PURIFIER
Setting Up
•IMPORTANT: Remove the plastic wraps from the lters before use.
•Always ensure that the pull tabs are facing outward when inseing the lter in.
•Always ensure that the lters and covers are properly installed in place before use.
1 2 3
Remove the adapter from the bottom
before use. Place the air purier on a at,
stable suace. Pull the sides of the front
and rear covers to remove both covers.
Remove the lters from the front and rear of
the air purier.
Remove the plastic wraps from both lters.
* Discard and do not allow children to play with the
plastic wraps.
Place both lters back into the air purier.
Ensure that the pull tabs are facing
outward when inseing the lter in.
4 5 6
Align with the bottom slots and attach the
front and rear covers back. Press the covers
to secure in place.
Locate the air purier with enough
circulation space around (> 8 inches). Run
the cord through the slot and plug in the
air purier.
> 8in /
20cm
> 8in /
20cm
Face pull
tabs outward
background
Replacing Filter
1 2 3
will ash red as a reminder to replace
the lter. Press once to turn o and
unplug the air purier.
Open the front and rear covers to remove
the old lters from the air purier.
09
10
4
5 6
Align with the bottom slots and attach the
front and rear covers back. Press the
covers to secure in place.
Plug in and press once to turn on the
air purier.
Press and hold for 6 seconds until
three beeps are heard to reset the lter
life.
•When the lter reaches its seice life (2000 hours), will ash red as a reminder to replace the lter.
•Turn o and unplug the air purier before replacing the lter.
•Using your purier in heavily polluted or dusty environments may cause the lter to clog faster, reducing its lifespan. To
maintain optimal peormance, clean and replace the lter more frequently.
Place new lters in. Ensure that the pull
tabs are facing outward.
Face pull
tabs outward
x1
x1
6s
background
Cleaning HEPA Filter & Pre-Filter
11 12
CARE AND MAINTENANCE
•Always make sure the air purier is turned o and unplugged before cleaning.
•DO NOT stick any foreign objects or your ngers inside of the air purier.
•Never immerse in water or allow water to drip into the motor housing.
•DO NOT clean with abrasive chemicals or ammable cleaning agents.
Wipe the suace with a soft, d cloth. If
necessa, wipe with a damp cloth, then
immediately d.
Vacuum up dust with a vacuum cleaner or
wipe it with a cloth.
Clean the dust sensor with a lightly
dampened cotton swab. Wipe d with a
d cotton swab.
* Clean eve 6 months to help maintain the eciency of
the sensor. If your air is often polluted with dust, dander,
smoke, and other paicles, you may need to clean the
dust sensor more often.
Outer Suace Air Outlet
Dust Sensor
•Clean the pre-lter when paicles are visible or excessive noises are heard. It is recommended to clean eve 2 weeks.
•Using your purier in heavily polluted or dusty environments may cause the lter to clog faster, reducing its lifespan. To maintain
optimal peormance, clean and replace the lter more frequently.
Turn o and unplug the air purier. Open
the front and rear covers and remove the
lters from the air purier.
Vacuum up dust on the main unit and
lters with a vacuum cleaner.
Gently pull the pre-lter apa from the
HEPA lter. If the pre-lter is heavily soiled
with dust and debris, rinse it with water. Air
d thoroughly before attaching it back.
1 2 3
background
13 14
4 5 6
Vacuum up dust on the HEPA lters with a
vacuum cleaner. Do not rinse or immerse
in water. Replace the lters when seice
life is reached.
Attach the pre-lters back to the HEPA
lters. Place both lters back. Ensure that
the pull tabs are facing outward.
Align with the bottom slots and attach
the front and rear covers back. Press the
covers to secure in place.
TROUBLESHOOTING GUIDE
The troubleshooting guide addresses the most common problems. If problems persist, feel free to contact the
Customer Suppo via email: suppo@meowanthome.com
Problem Solution
Air purier does not turn
on or respond to button
controls.
Ailow is signicantly
reduced.
•Ensure that the lters are removed from the packaging and properly installed in place.
•Leave at least 8 inches / 20 cm of clearance around the air purier. Ensure enough circulation space.
•Adjust to a higher fan speed.
•The pre-lter may be clogged by large paicles, such as hair or lint, blocking ailow. Clean the pre-lter.
•Check if HEPA lter reaches its seice life. Replace the lter if necessa.
•Check and clean the lters. Replace the lters if necessa.
•Make sure not to use your air purier in an area with high humidity. High humidity levels may cause
mildew to grow on the lters.
Strange smell coming from
air purier.
•Ensure that the air purier is properly connected to a powered electrical outlet.
•Ensure that the power adapter is rmly plugged into the power po.
•Check if the power cord is damaged. Stop using the air purier if damaged and contact our Customer
Suppo for help.
•Check if child lock is turned on. Press and hold child lock button for 3s to cancel.
Face pull
tabs outward
background
FCC Compliance
This device complies with Pa 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful inteerence, and
(2) this device must accept any inteerence received, including inteerence that may cause undesired operation.
15 16
•Ensure that the lters are properly in place with plastic wraps removed.
•Ensure that the front and rear covers are properly installed in place.
•Ensure that the air purier is operating on a hard, at, level suace.
•Check and clean the lters. Replace the lters if necessa.
•Remove the covers and lters to check if there is any foreign objects inside the air purier.
•Clean the dust sensor.
•Avoid using an ultrasonic humidier near the air purier. If you are using an ultrasonic humidier near
the air purier, the mist may aect the accuracy of the dust sensor.
Air purier makes an
unusual noise while the
fan is on.
Poor air purication quality.
•Adjust to a higher fan speed.
•Ensure that no objects are blocking the front, rear or top of the air purier (inlet or outlet).
•Ensure that the lters are properly in place with plastic wraps removed.
•Check and clean the lters. Replace the lters if necessa.
•For optimal purication peormance, close doors and windows while using the air purier.
•If the room is too large, air purication will take longer.
Air quality indicator always
stays red under good air
quality.
•Clean the dust sensor.
•The dust sensor detects airborne paicles, but it cannot detect gas. Make sure there are no gasses
polluting the air.
Air quality indicator always
stays green even under poor
air quality.
How to get replacement
lters?
For replacement lters, search for MeoWant replacement lter on Amazon or contact our Customer
Suppo via email: suppo@meowanthome.com. DO NOT use replacement lters that are not
recommended by the manufacturer.

Specifications

Indexed Terms: Pet Air Purifier

MeoWant MW-PA16 Questions and Answers

Questions and Answers

Related Products