Colderatti CLDRTI-PLNG-VSSL Vessel Cold Plunge

Product's Documents

Below are documents related to this product, you can read online or download:
User Manual Specification
CLDRTI-PLNG-VSSL photo

User Guide

This is the main product document for model CLDRTI-PLNG-VSSL. Additionally, the document applies to other Colderatti models: CLDRTI-PLNG-VSSL4W

The file format is pdf, 25 pages, you can download this manual here .

background
Vessel
U s e r G u i d e
background
• I n s t a l l a t i o n & S e t u p
• E l e c t r i c a l
• A p p C o n n e c t i o n
• C o n t r o l P a n e l
• H o w T o D r a i n / F i l l
• P l u m b i n g & V a l v e s
• W a t e r C a r e
• F i l t e r R e p l a c e m e n t
• R e m o t e - C h i l l e r S e t u p
• S a f e t y P r e c a u t i o n s
Contents
Click any item below to navigate directly to that section.
4
1 0
1 2
1 4
1 5
1 6
1 8
2 0
2 2
2 4
background
Product Dimensions
V e s s e l U s e r G u i d e 3
32" [815]
66“ [1680]
28“ [710]
31“ [792]
17.7“ [450]
24" [610]
Ventilation
Clearance
113“ [2870]
background
Installation & Setup
V e s s e l U s e r G u i d e 4
Site requirements
Place the Vessel and Hyperchiller on a solid, level, waterproof surface.
Maintain space surrounding the ice bath as detailed in the roughing-in image below.
The cord is 5 ft. long. If you plan to use an extension cord, use a 12-gauge.
Floor Drain
Electrical Outlet
Voltage
Amperage
Non-GFCI Receptacle Recommended*
120V
Dedicated 20A Circuit
3" Min
4" Min
24" Min
Fan exhaust clearance
Water Supply
*Unit includes integrated GFCI protection. It is not suggested to use in conjunction with a GFCI-protected outlet.
This will create a situation prone to nuisance tripping*
Note: chiller can be placed remotely, up to 40 feet away from tub, and connected via 2 water lines. Choose
between Colderatti insulated water lines or dedicated plumbing lines (See ‘Remote-Chiller Setup’ for details).
Plumbing Requirements: The unit is designed for self-contained, freestanding operation with no permanent
plumbing required. Unit may be operated by draining/filling with a standard hose. Water supply and floor drain
are optional.
background
A
B
C
D
A
C
B
I
N
L
E
T
O
U
T
L
E
T
A
A
V e s s e l U s e r G u i d e 5
Attach drain valve (3/4" thread) to the Vessel drain thread.
Attach shutoff valves (1/2" thread) to the Vessel IN, OUT, and FILL.
1. Connect valves and pre-filter:
Twist all valves to the OFF position
(valve ON position = straight, valve OFF position = sideways).
Attach pre-filter to the Hyperchiller INLET. Ensure the rubber o-ring
gasket is present before you screw it on.
Hyperchiller: backside
background
Connect one water line from Hyperchiller OUTLET Vessel IN.
Connect second water line from the pre-filter Vessel OUT.
V e s s e l U s e r G u i d e 6
2. Connect water lines:
Confirm pre-filter is attached to the Hyperchiller INLET.
Confirm the drain and fill shutoff valves are on the tub and twisted
to the OFF position.
A
B
C
D
A
B
B
C
C
D
D
background
V e s s e l U s e r G u i d e 7
3. Fill with Water:
Fill the Vessel with a hose to the level of the water inlet valves,
about 5 inches below the top.
* How to drain/fill your Vessel and how to plumb drain/fill valves on page 11&12
background
*Failure to follow these precautions may damage the machine and void warranty.
4. Before turning on your cold plunge:
V e s s e l U s e r G u i d e 8
filter inside
hand-tightened
straight & secure
Water must be
above bottom valve
A
B
C
D
F
The water level must be at least above the bottom water valve.
Verify the clear filter canister is securely hand-tightened to the chiller,
and the filter is inside, straight and securely seated.
Verify the shut-off water valves are straight, in the ON position (page 5).
Ensure the sediment pre-filter is securely connected (page 5).
Ensure the two water cables are properly connected to the tub and
chiller, and in the correct orientation (page 2).
A
B
E
Ensure the rubber seals are in place in the 2 water cables and the pre-
filter (page 5).
background
C
D
V e s s e l U s e r G u i d e 9
C
D
E
background
V e s s e l U s e r G u i d e 10
5. Plug In:
Before plugging in your Hyperchiller, make sure all items in Step 4:
Before turning on your cold plunge are fully completed and verified.
Plug your Hyperchiller into a standard 120V outlet. The outlet must
be on a dedicated 20A (minimum) circuit.
NEMA 5-20, (3-pronged
standard outlet)
120V, 20A
The machine includes built-in GFCI protection, so an additional external
GFCI is not necessary and may cause nuisance tripping.
Use only a 12-gauge extension cord if needed.
background
V e s s e l U s e r G u i d e 11
6. Set Temperature:
UP
DOWN
SET
POWER
Power on the Hyperchiller by pressing the POWER button.
Press and hold the UP & DOWN buttons at the same time to toggle
lock/unlock (a lock icon will show the lock status).
Allow system 1 hour to reach the temperature target.
Press the SET button (the temperature will start flashing on the control
panel) and use the UP/DOWN buttons to set temperature.
background
V e s s e l S e t u p G u i d e 12
7. Pair your Vessel with the app:
Download the Smart Life app.
Press and hold the UP & DOWN buttons at the same time to
toggle lock/unlock (a lock icon will show the lock status).
Hold the SET button for 7 seconds. Let go. You will hear a beep
and see the WiFi icon flash.
Press “Add Device” on the app, and the chiller will auto-connect.
App Store
Google Play
UP
DOWN
SET
POWER
Recommended schedule:
Press “Timing Control” on the app
to begin setting a schedule.
Residential
7 days per week – 9hrs runtime
5AM–8AM (3hrs)
11AM–2PM (3hrs)
5PM–8PM (3hrs)
Commercial
7 days per week – 24hrs runtime
No schedule. 24/7 water
circulation recommended.
Hyperchiller will auto-regulate
temperature, filtration, and water
purification.
background
V e s s e l U s e r G u i d e 13
Setup is complete!
• Control Panel
• How To drain and Fill your Vessel
• How To Plumb Drain/Fill Valves
• Drain/fill Valve Locations and Specs
• Water Care & Maintenance
• Deep Clean Your Plunge
• Cleaning Requirements
• Replacing the Filter
• Water Testing
• Remote Chiller Setup
• Remote Chiller Setup Drawings
• Safety Precautions
• Service & Troubleshooting
–
–
–
–
–
–
–
–
–
–
–
–
–
Page 14
Page 15
Page 16
Page 17
Page 18
Page 19
Page 19
Page 20
Page 21
Page 22
Page 23
Page 24
Page 24
Instructions for use:
background
V e s s e l U s e r G u i d e 14
Control panel
POWER
SET
DOWN
UP
• Press POWER button once to turn on. Press once to turn off.
• Press and hold SET button for 7 seconds then release to enter pairing for app connection.
• Press and hold UP and DOWN buttons to toggle lock/unlock. A lock icon will appear to show lock
status. When locked, you cannot change the temperature or power off.
• Press the UP and DOWN buttons to change temperature.
background
V e s s e l U s e r G u i d e 15
How to drain and fill your Vessel:
Without Plumbing:
To Fill:
Using a garden hose, fill the tub with water until the water level
reaches the top valve (the water jet).
*Plumbing is optional. For drain and fill plumbing
instructions, see the next page.
To Drain:
Attach a garden hose to the drain valve (bottom valve on the back of the
Vessel), then open the valve to drain.
If you have an automatic water pump:
• Connect a garden hose to the top port of the automatic water pump.
• Submerge the pump fully in plunge basin until it rests on the bottom.
• Route hose to drain location, plug in pump. Monitor water level.
background
V e s s e l U s e r G u i d e 16
Drain/fill with plumbing:
*refer to page 12 for precise drain/fill valve locations
1. Drain valve (bottom): 3/4" GHT stainless steel thread. Connect to
gravity water drain. If needed, an inline booster pump can be installed.
2. Fill valve (top): 1/2" NPT stainless steel thread. Connect to water fill.
1
2
3/4" GHT Male
1/2" NPT Male
background
V e s s e l U s e r G u i d e 17
Vessel valve specifications:
background
V e s s e l U s e r G u i d e 18
Water Care & Maintenance:
Everything you need for water care in one package:
6-month maintenance kit (Residential)
6-month maintenance kit (Commercial)
*Maintain clean & clear water at all times. If at any moment the water is not
crystal clear, replace the water with fresh water and replace the filter.
Initial Fill-Up
4oz Colderatti water clarifier
Daily Maintenance
1/2oz Colderatti water clarifier
Monthly Maintenance
• Replace water with fresh water
• Replace the filter
• Rinse the pre-filter
Quarterly Deep Clean¹
Every 3 Months, deep clean
¹ Deep cleaning is recommended for optimal performance and longevity of
the machine. Instructions on next page.
Initial Fill-Up
4oz Colderatti water clarifier
Daily Maintenance
1oz Colderatti water clarifier
Bi-Monthly Maintenance
• Replace water with fresh water
• Replace the filter
• Rinse the pre-filter
Quarterly Deep Clean¹
Every 3 Months, deep clean
Residential Water Care
If your Vessel lives at home, follow
these care instructions to keep it
clean, clear, and performing like
new.
Commercial Water Care
If your Vessel is used in a
commercial setting (gym, spa, or
shared space), more frequent care
is required.
background
V e s s e l U s e r G u i d e 19
Deep clean your plunge
We recommend deep cleaning your plunge every 3 months, for optimal
performance and longevity of the machine.
1. Drain all water and refill with clean water to 1/3 capacity.
2. Add 8oz (1 cup) food-grade citric acid*
3. Turn the Hyperchiller on and set the temp to max hot.
4. Let the water cycle for 30 minutes with the citric acid solution.
5. Turn the Hyperchiller off and drain the tub fully.
6. Rinse the inside basin with warm water and a clean washcloth.
7. Run a final flush: fill with clean water to 1/3 capacity and turn the
Hyperchiller on for 5 minutes. Then turn off and drain water fully.
8. Replace the filter with a new filter. Deep clean is finished.
*Citric acid is a natural descaler that breaks down mineral deposits, biofilm,
and tarnish from the inside surface of the system—ideal for naturally flushing
your system and restoring it to a like-new condition, while leaving the stainless
steel more rust-resistant and with a visibly cleaner and brighter finish.
Cleaning requirements
Follow these best practices for regular cleaning and care to keep your
Colderatti stainless steel system in peak condition.
Water care: use Colderatti water clarifier regularly and replace filters as
required to keep water clean, clear, and free of oils and debris.
Stainless steel:
Clean stainless steel surfaces with a soft cloth and mild degreaser (dish
soap).
For tough mineral spots or stains, wipe stainless steel with warm water
and food-grade citric acid, then rinse.
Always rinse and dry surfaces after cleaning.
Use only soft microfiber cloths—never abrasive scrubbers.
DO NOT mix citric acid or hydrogen peroxide with other cleaning
chemicals.
background
V e s s e l U s e r G u i d e 20
Replacing the filter
Replace the filter once per month for optimal performance and
longevity of the machine.
• Unscrew the clear filter canister.
• Remove the old filter, dump the dirty water from the canister, replace
with new filter. Screw in.
1
2
3
4
5
remove old filter
insert new filter
background
V e s s e l U s e r G u i d e 21
Water Testing
If you choose to test your water using water test strips, expect each
parameter to fall within the ideal ranges below:
1. Free Chlorine or Bromine: 0ppm
2. pH: 7.2–7.8
3. Total Alkalinity: 80–120 ppm
4. Calcium Hardness: 150–250 ppm
5. Total Dissolved Solids (TDS): under 1,500 ppm
6. Cyanuric Acid: 0 ppm
7. Oxidation-Reduction Potential (ORP): 650–750 mV
• If pH is low: turn on the machine with ozone enabled and add 1/2 oz
Colderatti Water Clarifier.
• If hardness is low: add Colderatti Magnesium Sea Salt Blend.
Expected Results After 2 Weeks of Daily Use:
With proper daily water care, pH, Alkalinity, Hardness, and TDS levels typically fall
within 90–95% of ideal ranges. Results may vary based on user hygiene, adherence
to water care routines, and the quality of your initial water source.
background
V e s s e l U s e r G u i d e 22
Remote-Chiller Setup:
1. Distance Requirements:
Max vertical lift: 15 ft
Max run length (vertical + horizontal): 40 ft
Make sure the chiller is placed within these limits.
2. Connect Water Cables (IN/OUT):
If connecting through wall ports:
Label wall lines as IN/OUT clearly to avoid confusion.
Hyperchiller INLET
→
connects to tub OUT (bottom) valve
Hyperchiller OUTLET
→
connects to tub IN (top) valve
4. Prime the INLET Line:
Use a hose to push water into the INLET cable and remove air.
Fill the filter chamber with water before powering on.
3. Ensure Proper Ventilation:
Chiller must have 24" clearance on fan end.
5. Final Checks Before Powering On:
Review Step 4 (Page 4) for full checklist.
If chiller is placed in enclosed area, it must have (either):
At least 2 passive vents (one vent next to Hyperchiller fan out, one
vent opposite, allowing adequate passive airflow) OR
Inline duct fan (400 CFM+) high, and passive vent low, near chiller.
An open area or well-ventilated room with natural airflow is ideal for the
chiller and requires no additional venting or fan system.
*See next page for drawings
background
Side View
V e s s e l U s e r G u i d e 23
Remote-Chiller Setup Drawings
Vessel tub
Hyperchiller
Vessel tub
Hyperchiller
Top View
15ft max vertical lift
A <= 15
40ft max run length
A+B+C <= 40
A
B
C
A
Any water lines running through
walls or long distances (e.g. a 1/2"
copper pipe running 20 feet to
another room) must be wrapped
in a 1/2" thick (minimum)
insulative sleeve. This prevents
temperature loss and ensures
proper system performance.
The chiller should always be
placed at or below the level of
the tub and never above.
background
V e s s e l U s e r G u i d e 24
Safety Precautions:
No children or pets – never allow unsupervised access. Secure the cover when not
in use.
No alcohol or drugs – these can drastically increase the risk of unconsciousness,
drowning, or hypothermia.
Know your limits – sudden cold immersion can trigger cold shock or hypothermia.
Always use under supervision until you know your body’s response.
Electrical safety – only use a dedicated 20A, 120V circuit with GFCI protection;
keep all outlets and devices 5 feet away.
Do not modify electrical components – only qualified technicians should access
internal electronics. Tampering can lead to electric shock, fire, or system failure.
Consult Your Doctor – especially if pregnant, have heart conditions, blood
pressure issues, diabetes, or are taking medication that may cause drowsiness.
Use with supervision if needed – those with reduced physical, sensory, or mental
ability should only use the plunge under supervision.
Service & Troubleshooting:
Error Code
Reason
Solution
CLN
Low Flow Rate
Clean the filter
FL
Flow Issue
Possible solutions:
• Confirm both water valves are in the ON position (straight).
• Confirm seal rings are on the inside of the water hoses.
• Reset the Hyperchiller. Power it off and on.
Freezing Conditions – Operating or storing this equipment in temperatures below
32°F (0°C) strictly voids the warranty. While the Hyperchiller is equipped with
internal freeze protection as a safety measure; it is not rated for operation or
storage in freezing environments. The system must remain powered on at all times
to utilize its internal safety sensors; if the unit loses power or is turned off in cold
conditions, it must be drained and moved indoors immediately. Any damage
resulting from freezing temperatures – including damage resulting from power
failure or outdoor placement – is at the user’s own risk and is strictly excluded from
warranty coverage.
background

Specifications

Indexed Terms: Cold Plunge, Vessel

Colderatti CLDRTI-PLNG-VSSL Questions and Answers

Questions and Answers

Related Products