WCP-SERIES Operator's Manual 1
OPERATORS MANUAL FOR Mi-T-M
®
WCP-SERIES
WATER RECYCLING TREATMENT SYSTEM
©Copyright 2005, Mi-T-M Corporation® Form #37-0614-071522
CAUTION
RISK OF INJURY!
READ MANUAL BEFORE OPERATING!
This manual is an important part of the water recycling treatment system and must remain with
the unit when you sell it!
background
2 Mi-T-M
®
WCP-SERIES Operator's Manual
Contents
INTRODUCTION ........................................................................................................................................................... 3
CONTENTS OF WCP-SERIES WATER RECYCLING TREATMENT SYSTEM ...................................................... 4
SPECIFICATIONS ......................................................................................................................................................... 4
IMPORTANT SAFETY WARNINGS ............................................................................................................................. 5
FLOW DIAGRAM ....................................................................................................................................................... 8-9
FEATURES FOR WCP-10 ......................................................................................................................................... 10
FEATURES FOR WCP-10 ...........................................................................................................................................11
FEATURES FOR WCP-20 .......................................................................................................................................... 12
FEATURES FOR WCP-20 .......................................................................................................................................... 13
FEATURES FOR WCP-30 .......................................................................................................................................... 14
FEATURES FOR WCP-30 .......................................................................................................................................... 15
INSTALLATION ........................................................................................................................................................... 16
PRE-OPERATION CHECKLIST ................................................................................................................................. 19
PREPARATION ........................................................................................................................................................... 20
PRESTART PROCEDURES: ................................................................................................................................ 20
START-UP: ............................................................................................................................................................. 20
pH AND ORP CONTROL SYSTEM:..................................................................................................................... 21
INSTALLATION OF PH AND ORP PROBES: ..................................................................................................... 22
PH CONTROLLER PROGRAMMING .................................................................................................................. 23
ORP CONTROLLER PROGRAMMING: .............................................................................................................. 23
MEASURE MODE: ORP RMV ............................................................................................................................. 23
FRONT PANEL ...................................................................................................................................................... 23
LCD SCREEN ........................................................................................................................................................ 24
MEASURE MODE ................................................................................................................................................. 24
SETTINGS MODE ................................................................................................................................................. 25
PH BUFFER 1 SELECT: ....................................................................................................................................... 25
RELAY CONTROL PARAMETERS SELECT: ..................................................................................................... 26
PH CALIBRATION MODE .................................................................................................................................... 27
CONTROLLING THE RELAYS ............................................................................................................................ 27
OPERATION: ......................................................................................................................................................... 28
FINAL PH AND ORP SYSTEM SETUP: .............................................................................................................. 28
OPERATION ................................................................................................................................................................ 29
SETTING OF THE WATER RECYCLING TIMER: .............................................................................................. 29
MAINTENANCE ........................................................................................................................................................... 30
WASTE OIL DECANTER: ..................................................................................................................................... 30
SOLIDS COLLECTION AREA: ............................................................................................................................ 30
BACKWASHING OF FILTERS: ............................................................................................................................ 30
ACTIVE CARBON TEST: .................................................................................................................................... 32
REMOVING & REFILLING MEDIA FROM THE MULTIMEDIA & POLISHING FILTER: .................................. 33
WATER TESTING: ................................................................................................................................................ 34
MAINTENANCE: ................................................................................................................................................... 34
BUFFER 1 (STAND) CALIBRATION: ................................................................................................................... 35
BUFFER 2 (SLOPE) CALIBRATION: ................................................................................................................... 35
ORP CALIBRATION: ............................................................................................................................................. 35
WINTERIZING: ...................................................................................................................................................... 36
TROUBLESHOOTING ................................................................................................................................................ 37
REPLACEMENT PARTS ............................................................................................................................................ 43
STATEMENT OF WARRANTY ................................................................................................................................... 44
WARNING: This product can expose you to
chemicals including carbon monoxide, which is
known to the State of California to cause birth
defects or other reproductive harm. For more
information go to www.P65Warnings.ca.gov
WARNING
WARNING: This product can expose you to
chemicals including Lead, which is known to
the State of California to cause cancer and birth
defects or other reproductive harm. For more
information go to www.P65Warnings.ca.gov
WARNING
background
Mi-T-M
WCP-SERIES Operator's Manual 3
Congratulations on the purchase of your new Mi-T-M water recycling treatment system! You can be assured your Mi-T-M
water recycling treatment system was constructed and designed with quality and performance in mind. Each component
has been rigorously tested to ensure the highest level of acceptance.
This operator's manual was compiled for your benet. By reading and following the simple safety, installation, operation,
maintenance and troubleshooting steps described in this manual, you will receive years of trouble free operation from
your new Mi-T-M water recycling treatment system. The contents of this manual are based on the latest product informa-
tion available at the time of publication. Mi-T-M reserves the right to make changes in price, color, materials, equipment,
specications or models at any time without notice.
! IMPORTANT !
These paragraphs are surrounded by a "SAFETY ALERT BOX". This box is used to designate
and emphasize Safety Warnings that must be followed when operating this water recycling
treatment system.
Accompanying the Safety Warnings are "signal words" which designate the degree or level of
hazard seriousness. The "signal words" used in this manual are as follows:
DANGER: Indicates an imminently hazardous situation which, if not avoided, WILL
result in death or serious injury.
WARNING: Indicates a potentially hazardous situation which, if not avoided, COULD
result in death or serious injury.
CAUTION: Indicates a potentially hazardous situation which, if not avoided MAY
result in minor or moderate injury.
The symbols set to the left of this paragraph are "Safety Alert Symbols". These symbols are
used to call attention to items or procedures that could be dangerous to you or other persons
using this equipment.
ALWAYS PROVIDE A COPY OF THIS MANUAL TO ANYONE USING THIS EQUIPMENT. READ
ALL INSTRUCTIONS BEFORE OPERATING THIS WATER RECYCLING TREATMENT SYSTEM
AND ESPECIALLY POINT OUT THE "SAFETY WARNINGS" TO PREVENT THE POSSIBILITY OF
PERSONAL INJURY TO THE OPERATOR.
Once the unit has been uncrated, immediately write in the serial number of your unit in the space provided below.
SERIAL NUMBER_________________________________
Inspect for signs of obvious or concealed freight damage. If damage does exist, le a claim with the transportation company
immediately. Be sure that all damaged parts are replaced and that the mechanical and electrical problems are corrected
prior to operation of the unit. If you require service, contact Mi-T-M Customer Service at 1-800-553-9053 for the Sales or
Service Center nearest you.
Please have the following items available for all Service calls:
1. Model Number
2. Serial Number
3. Date and Place of Purchase
INTRODUCTION
background
4 Mi-T-M
®
WCP-SERIES Operator's Manual
CONTENTS OF WCP-SERIES WATER RECYCLING TREATMENT SYSTEM
Carefully unpack your new Mi-T-M WCP-Series Water recycling treatment system. Check the contents against the
packing list. Contact the freight line if a damage claim is required on any component. The following items are the basic
equipment sent with your WCP-Series Water recycling treatment system.
SPECIFICATIONS
2. Sump Pump
3. Three Unattached Floats for Sump Pit
a. Blue: Protects sump pump low level.
b. Red: To ll pit from the water recycling treatment system.
c. Green: High pit level discharge.
4. Sludge Tub
5. Sludge Hose
6. Water Test Kit
7. Manual
8. pH Sensor Probe
9. ORP Sensor Probe
1. Water recycling treatment system Platform
a. Clarier Type Oil/Solids Separator
1. Clarier Tank
2. Tank Stand
b Ozone Generator
c. Ozone Pump
d. Filter Pump
e. Inlet Flow Meter
f. Filter Flow Meter
g. Multi-Media Filter
h. Cartridge Filter
i. Polishing Filter
j. Transfer Pump
k. Pressurized Water Storage Tank
l. Waste Oil Decanter
MODEL WCP-10-0M10 WCP-20-0M10 WCP-30-0M10
MAX FLOW 10 GPM 20 GPM 30 GPM
ELECTRICAL 230 VOLT / 1 PHASE /
30 MAX AMP
230 VOLT / 1 PHASE /
35 MAX AMP
230 VOLT / 1 PHASE /
37 MAX AMP
SUMP PUMP 1 HP 1 HP 1 HP
OZONE PUMP 1/2 HP 1/2 HP 1/2 HP
CLARIFER CAPACITY 300 GALLONS 600 GALLONS 600 GALLONS
OIL COALESCING AREA 275 SQUARE FEET 425 SQUARE FEET 425 SQUARE FEET
FILTER PUMP 1 1/2 HP 1 1/2 HP 1 1/2 HP
MULTI-MEDIA FILTER 350 LBS 350 LBS 900 LBS
CARTRIDGE FILTER 100 SQ FT / 30 MICRON 400 SQ FT / 30 MICRON 400 SQ FT / 30 MICRON
POLISHING FILTER 110 LBS DEGASSED 110 LBS DEGASSED 165 LBS DEGASSED
TRANSFER PUMP 3/4 HP 3/4 HP 2 HP
DIMENSIONS 96" X 60" X 101" 96" X 72" X 110" 108" X 84" X110"
NET WEIGHT 1800 LBS 2650 LBS 3225 LBS
background
Mi-T-M
WCP-SERIES Operator's Manual 5
IMPORTANT SAFETY WARNINGS
WARNING: When using this product, basic precautions should always be observed, including the following:
READ ALL SAFETY WARNINGS BEFORE USING WATER RECYCLING TREATMENT SYSTEM
POTENTIAL CONSEQUENCE PREVENTION
Serious injury or death could occur if
the water recycling treatment system
is not properly grounded. Your
water recycling treatment system
is powered by electricity and may
cause electric shock or electrocution
if not installed properly.
Installation of this unit, including all electrical
connections, must comply with all local, state
and national codes.
This product must be grounded. Connect to a
GFCI circuit breaker when available. If the unit
should malfunction or breakdown, grounding
provides a path of least resistance for electric
current to reduce the risk of electric shock. Do
not ground to a gas supply line.
Improper connection of the equipment-
grounding conductor can result in a risk of
electrocution. Check with a qualied electrician
or service personnel if you are in doubt as to
whether the system is properly grounded.
Always be certain the unit is receiving proper
voltage (+/- 5% of the voltage listed on the
nameplate). Before installing electrical
connections, be certain the power switches
are in the "OFF" position.
Keep all connections dry and o󰀨 the ground.
DO NOT allow metal components of the water
recycling treatment system to come in contact
with live electrical components.
Never operate the water recycling treatment
system with safety guards/covers removed
or damaged. Ensure all electrical covers are
securely in place when unit is operating.
Any electrical wiring or repairs performed on
this water recycling treatment system should
be done by Authorized Service Personnel in
accordance with National and Local electrical
codes.
Before opening any electrical enclosure,
always shut o󰀨 the water recycling treatment
system and drain the water. Disconnect the
water recycling treatment system from the
power source. If the power disconnect is not
in sight, lock it in the open position and tag
it to prevent power usage. (Never assume
the water recycling treatment system is safe
to work on just because it is not operating, it
could restart at any time! Always disconnect
from the power source.)
RISK OF ELECTRIC SHOCK
OR ELECTROCUTION
HAZARD
Electrical shock may occur if water
recycling treatment system is not
operated properly.
Serious injury or death may occur if
electrical repairs are attempted by
unqualied persons.
background
6 Mi-T-M
®
WCP-SERIES Operator's Manual
Never allow any part of your body to contact
the electrical motor until cooled.
POTENTIAL CONSEQUENCE
PREVENTION
IMPORTANT SAFETY WARNINGS
READ ALL SAFETY WARNINGS BEFORE USING WATER RECYCLING TREATMENT SYSTEM
RISK OF EXPLOSION OR FIRE
Serious injury or death could occur
from an explosion or re caused
by a system electric spark.
This unit must be placed in an area that is
well ventilated, free of ammable vapors,
combustible dust, gases or other combustible
materials.
HAZARD
RISK OF BURNS
Serious injury may occur from
touching the electrical motor.
This area can remain hot for
some time after the water
recycling treatment system is
shutdown.
RISK OF BURSTING
Serious injury or death could occur
from bursting caused by excessive
pressure in the system.
Do not mistreat the pressure gauges on the
system. Pressure gauges will malfunction
if they are subjected to excessive pressure,
vibration, pulsation or temperature or if they
are placed in an environment which causes
corrosion of parts. Incorrect readings on a
pressure gauge could mislead the operator and
place him in a dangerous working condition.
Do not use a booster pump or any type of
additional pumping system. Pressurizing the
suction of the pump may cause the pump body
to explode.
Do not use this water recycling treatment
system to pump ammable material! An
explosion could occur from a gas vapor buildup
inside the system.
In freezing temperatures, the unit must always
be warm enough to ensure there is no ice
formation in the pump. Do not start the water
recycling treatment system if it has been in a
freezing environment without rst allowing the
pump to thaw.
Serious injury may occur if
attempting to start the water
recycling treatment system when
the pump is frozen.
background
Mi-T-M
WCP-SERIES Operator's Manual 7
RISK OF BODILY INJURY
Injury may occur from the water
recycling treatment system.
!SAVE THESE INSTRUCTIONS!
HAZARD
POTENTIAL CONSEQUENCE
PREVENTION
IMPORTANT SAFETY WARNINGS
READ ALL SAFETY WARNINGS BEFORE USING WATER RECYCLING TREATMENT SYSTEM
DO NOT DRINK THE WATER IN THE
WATER RECYCLING TREATMENT
SYSTEM!! This is non-potable water and is
not suitable for consumption.
The Cartridge Filter operates under pressure.
DO NOT attempt to loosen the locking ring or
open the lter tank unless the pump is turned
o󰀨 an the air relief valve is opened.
DO NOT allow children to operate this unit.
DO NOT overreach or stand on unstable
support.
Wet surfaces can be slippery, wear protective
foot gear and keep good footing and balance
at all times.
Know how to stop the water recycling treatment
system. Be thoroughly familiar with controls.
Before servicing, ALWAYS shut o󰀨 the water
recycling treatment system.
Never use any solvents or highly corrosive
detergents or acid type cleaners with this water
recycling treatment system.
Keep all chemicals out of the reach of
children!
Consult Material Safety Data Sheets for safe
handling of chemicals used with your system,
especially oxidizers and acids.
Serious injury may occur to the
operator from moving parts on the
water recycling treatment system.
Do not operate the unit without all
protective covers in place.
Follow the maintenance instructions
specied in the manual.
RISK FROM MOVING PARTS
Injury may occur from chemicals
contacting the skin.
background
8 Mi-T-M
®
WCP-SERIES Operator's Manual
FLOW DIAGRAM
As pressure washers are being operated, used water ows into the Wash Water Catch Pit (1). From there, it moves
to the 3-Stage Collection Pit (2). Heavy debris falls to the bottom of the pit where it is trapped by a weir which is
designed to stop heavy debris while allowing the remaining water to move into the Sump Pit (3). The Sump Pump (4)
draws water from the Sump Pit (3) and brings it through the Water Inlet Flow Control Valve 1. This adjustable valve
is used to regulate the ow of water entering the water clarication tank. A Flow Meter (5) is positioned just ahead of
the water clarication tank. The water enters the water clarication tank through the Inlet Tee (6) and is directed down
to the Diverted Tee (7). From there the water is deected downward by the Solids Deection Cone (8), then to the
Solids Separation Chamber (9). The Solids Separation Chamber (9) allows the velocity of the water to slow so that
any suspended solids settle to the bottom. The water then rises up through the Oil Coalescing Cones (10).
WCP FLOW DIAGRAM-080700-JJ
background
Mi-T-M
WCP-SERIES Operator's Manual 9
1) The non-emulsied oil molecules in the water adhere to the Oil Coalescing Cones (10). When
enough oil molecules attach to each other, they form oil droplets. The oil droplets are carried along
with the water through the Top Separator Cone (11) and into the Oil Separation Chamber (12),
where the oil droplets oat to the surface. The Oil Skimmer (13) is positioned near the top of the Oil
Separation Chamber (12) which allows the thin layer of surface oil and water to drain into the Waste
Oil Decanter (14). Since oil is lighter than water, the oil oats to the top and is released from the
Waste Oil Decanter (14) when the Waste Oil Release Valve 2 is opened. Excess water is returned to
the Wash Water Catch Pit (1).
2) The solids that accumulate in the bottom of the Solids Separation Chamber (9) should be regularly
drained through the Solids Drain Valve 3 into the Sludge Tub (15) where the solids are ltered out
and the water is returned to the Wash Water Catch Pit (1). The Filter Bag (16) is biodegradable and
may be tied o󰀨 and disposed of as it is lled. If the solids accumulated at the bottom of the Solids
Separation Chamber (9) are unable to drain, open Valve 4 and Valve 5 to push the solids towards
the Sludge Tub (15). If the solids are still unable to drain, open Valve 6 and Valve 7 to break up the
solids on the inside of the Solids Separation Chamber (9). When the solids from the Solids
Separation Chamber (9) is empted, close Valve 4, Valve 5, Valve 6 and Valve 7.
3) An Anti-siphon Device (17) is attached to the Inlet Tee (5) to relieve any suction that may develop
when the Sump Pump (4) is turned o󰀨, preventing any siphoning of water back out of the water
clarication tank.
Water then ows through the Ozone Pump Valve 8 down past the Sensor Probes (18 & 19) then into the Ozone
Pump (20) where it is forced through the Ozone Injector (21) and back up into the Oil Separation Chamber (12).
(See “pH & ORP Control System” pg. 16 for details.)
1) Ozone is generated by oxygen molecules passing through a corona discharge Ozone Generator
(22). This is an electric charge which causes the oxygen atoms to become ozone molecules. Since
ozone molecules are extremely unstable, they only retain their structure for a very short time. For this
reason, ozone cannot be stored, but must be continually produced by the Ozone Generator (22).
2) Ozone kills bacteria approximately 3,000 times faster than chlorine.
3) The ow of ozone is controlled by the Ozone Flow Control Valve 9.
Water then ows from the Oil Separation Chamber (12) through the Outlet Ring (23) and into the Outlet Y (24).
The Outlet Tee (24) directs the water into the Product Tank (25) where the Filter Pump (26) sends the water to
the Filter Control Valve 10 which regulates the amount of water going into the ltering system. A Flow Meter (27) is
positioned just ahead of the Multi-Media Filter (28) to monitor ow. (Flow should be set at no more than the rating of
the machine.) The Multi-Media Filter Valve 11 has many settings, with only two being utilized: Filter and Backwash.
When in the “Filter” Position, water ows into the Multi-Media Filter (28) from the top and passes through several
layers of ltering product as it moves toward the bottom. By the time the water reaches the bottom to the lter tank,
the contaminants have been ltered down to approximately 30 microns. Laterals are positioned at the bottom of
the lter tank, which absorb the ltered water and move it up through the center and out the top of the tank. From
there, the water ows into the bottom of the Cartridge Filter (29). A Cartridge Filter Drain Valve 12 is located at the
bottom of the Cartridge Filter (29) for lter cleaning purposes. This valve should be closed during the water recycling
treatment operation. On initial start-up, the Air Bleed Valve (30) must be opened to let air escape while the Cartridge
Filter (29) lls with water. Once full, and the Air Bleed Valve (30) is closed, the water passes through the Reemay
Polyester Fiber lter which reduces the contaminants down to 20 microns. The water moves out of the Cartridge
Filter (29) and into the Polishing Filter Valve 13. This valve has many settings, two of which are utilized. “Filter” and
“Backwash” When in the “Filter” position, water ows into the Polishing Filter (31) from the top and passes through
the activated carbon or ltering agent. As it moves toward the bottom, the activated carbon or ltering agent absorbs
odor and contaminants while “polishing” the water. Laterals are positioned at the bottom of the tank, which absorb
the water and move it up through the center and out the top of the tank. From there, the water moves to the Product
Tank (32) where the recycled water is held until usage is required. When needed, water is pulled from the Product
Tank (25) by the Transfer Pump (33) and moved into the Pressure Tank (34). This tank holds water at 30-50
PSI/2.0-3.5 Bar. Water moves directly from this tank to the water discharge outlets upon demand.
If water is needed for washing, water is sent to the Outlet To Pressure Washer (35).
If the Wash Water Catch Pit (1) water level is low, water is added through the Fresh Water Makeup (38).
If the Wash Water Catch Pit (1) water level is too high, water is sent to the Rain Water Overow (36).
If the recycle timer turns on, water is sent through the Recycled Wash Water (37) to the Wash Water Catch
Pit (1).
FLOW DIAGRAM
background
10 Mi-T-M
®
WCP-SERIES Operator's Manual
FEATURES FOR WCP-10
22
21
20
19
18
16
7
108
9
VALVE 4
12
11
VALVE 5
17
15
14
13
6
5
VALVE 2
VALVE 1
4
3
2
3537
36
34
33
32
31
302928
27
26
25
23
24
1
VALVE 3
VALVE DESCRIPTIONS
1. Pressurized Clean-Out (Sludge
Outlet)
2. Pressurized Clean-Out (Solids
Chamber)
3. Ozone Pump
4. Ozone Flow Control
5. Solids Drain
6. Sludge Outlet Pressurized
Clean-Out (Not Shown)
7. Solids Chamber Pressurized
Clean-Out (Not Shown)
1. Inlet Flowmeter
2. High Filter Pump Float (Not
Shown)
3. Transfer Pump Float
4. Pressure Gauge: Transfer
Pump
5. Transfer Pump
6. Pressure Tank
7. Outlet Return To Pit
8. Orp Sensor Probe
9. Ph Sensor Probe
10. Inlet From Sump Pump
11. Ozone Pump
12. Sludge Outlet
13. Optional Return To Pit
14. Ozone Injector
15. Holding Tank Overow
16. Solids Separtaion Chamber
17. Oil Coalescing Cones
18. Solids Deection Cone
19. Diverter Tee
20. Top Separator Cone
21. Oil Separation Chamber
22. Lid
23. Sludge Tub
24. Filter Bag
25. Power Indicator Light
26. Indicator Ligh: Backwash
Required
27. Backwash Switch
28. Sump Pump Switch (On/O󰀨)
29. Filter Pump Swithc (On /O󰀨)
30. Transfer Pump Switch (On /O󰀨)
31. Ph/Orp Meters Switch (On/O󰀨)
32. Ph Pump Switch (On/O󰀨)
33. Orp Pump Switch (On/O󰀨)
34. Hour Meter
35. Orp Meter
36. Ozone Generator Switch (On/
O󰀨)
37. Ph Meter
UNIT DESCRIPTIONS
WCP-10-0M10 FEATURES FRONT ISO 022422
background
Mi-T-M
WCP-SERIES Operator's Manual 11
55
54
53
52
47 48 49
50
51
46
VALVE 94544
43
VALVE 8
42
41
40
39
38
6667
VALVE 13
68
6970
65
64
63
VALVE 12
VALVE 11
62
6160
59
58
VALVE 10
57
56
UNIT DESCRIPTIONS
38. Outlet Y
39. High Sump Pump Float
40. Filter Flowmeter
41. Low Filter Pump Float
42. End Fork Lift Holes (6' Fork Required)
43. Filter Pump
44. Air Relief Valve
45. Skid
46. Side Fork Lift Holes
47. Product Tank Overow
48. Rain Water Overow
49. Rinse Water Outlet
50. Outlet To Pressue Washer
51. Fresh Water Makeup
52. Ph Pump
53. Orp Pump
54. Orp Chemical Injector
55. Ph Chemical Injector
56. Polishing Filter
57. Pressure Gauge: Polishing Filter
58. Product Tank
59. Recycled Wash Water
60. Control Panel
61. Waste Oil Decanter
62. Ozone Generator
63. Oil Skimmer
64. Anti-Siphon Device
65. Outlet Ring
66. Holding Tank
67. Pressure Gauge: Multi-Media Filter
68. Multi-Media Filter
69. Cartridge Filter
70. Pressure Gauge: Cartridge Filter
WCP-10-0M10 FEATURES REAR AND TOP 022422
FEATURES FOR WCP-10
background
12 Mi-T-M
®
WCP-SERIES Operator's Manual
FEATURES FOR WCP-20
1
2
3
4
5
6
7
8
9
13
15
16
17
18
19
20
21
22
23
24 25
3638
35
VALVE 1
VALVE 2
VALVE 5
34
333231
30
29
26
27
28
VALVE 3
10 11 12
14
VALVE 4
37
VALVE DESCRIPTIONS
1. Pressurized Clean-Out (Sludge
Outlet)
2. Pressurized Clean-Out (Solids
Chamber)
3. Ozone Pump
4. Ozone Flow Control
5. Solids Drain
6. Sludge Outlet Pressurized
Clean-Out (Not Shown)
7. Solids Chamber Pressurized
Clean-Out (Not Shown)
1. Product Tank Overow
2. Inlet Flowmeter
3. High Filter Pump Float
4. Transfer Pump Float
5. Pressure Gauge: Transfer Pump
6. Transfer Pump
7. Pressure Tank
8. Inlet From Sump Pump
9. Outlet Return To Pit
10. Orp Sensor Probe
11. Ph Probe
12. Ozone Pump
13. Sludge Outlet
14. Ozone Injector
15. Optional Return To Pit
16. Solids Separation Pit
17. Oil Coalescing Cones
18. Solids Deections Cone
19. Holding Tank Overow
20. Diverter Tee
21. Top Separator Cone
22. Oil Separation Chamber
23. Lid
24. Sludge Tub
25. Filter Bag
26. Power Indicator Light
27. Indicator Light: Backwash
Required
28. Backwash Switch
29. Sump Pump Swtich (On/O󰀨)
30. Filter Pump Switch (On/O󰀨)
31. Transfer Pump Switch (On/O󰀨)
32. Ph/Orp Meters Switch (On/O󰀨)
33. Ph Pump Switch (On/O󰀨)
34. Orp Pump Switch (On/O󰀨)
35. Hour Meter
36. Orp Meter
37. Ozone Generator Switch (On/O󰀨)
38. Ph Meter
UNIT DESCRIPTIONS
FEATURES FRONT ISO & CONTROL PANEL - WCP-20-0M10 031122
background
Mi-T-M
WCP-SERIES Operator's Manual 13
39
40
41
42
43
46
47
48
49
50
51
52
53
56
57
62
VALVE 11
VALVE 12
63
64
65
65
VALVE 8
68
44 45
VALVE 9
VALVE 10
55
54
69
VALVE 13
66
67
61605958
VALVE DESCRIPTIONS
8. Filter Control
9. Cartridge Filter Drain
10. Polishing Filter Drain
11. Waste Oil Release
12. Water Inlet Flow Control
13. Multi-Media Filter
UNIT DESCRIPTIONS
39 Outlet Y
40 High Sump Pump Float
41 Filter Flowmeter
42 Low Filter Pump Float
43 End Fork Lift Holes
(6' Fork Required)
44 Filter Pump
45 Air Relief Valve
46 Skid
47 Side Fork Lift Holes
48 Rain Water Overow
49 Rinse Water Outlet
50 Outlet To Pressure Washer
51 Fresh Water Makeup
52 Orp Chemical Injector
53 Ph Chemical Injector
54 Polishing Filter
55 Pressure Gauge: Polishing Filter
56 Product Tank
57 Recycled Wash Water
58 Ph Pump
59 Orp Pump
60 Control Panel
61 Ozone Generator
62 Waste Oil Decanter
63 Oil Skimmer
64 Anti-Siphon Device
65 Holding Tank
66 Multi-Media Filter
67 Gauge: Multi-Media Filter
68 Cartridge Filter
69 Gauge: Cartridge Filter
FEATURES REAR ISO & TOP DOWN - WCP-20-0M10 031122
FEATURES FOR WCP-20
background
14 Mi-T-M
®
WCP-SERIES Operator's Manual
FEATURES FOR WCP-30
1
2
4
3
VAVLE 1
VALVE 2
5
6
7
8
9 10 VALVE 3
VALVE 4
13 14
15
19
17
20
21
22
23
24 25
35343332313029
36
38
26
27
28
16
VALVE 5
1211
18
37
VALVE DESCRIPTIONS
1. Pressurized Clean-Out (Sludge
Outlet)
2. Pressureized Clean-Out (Solids
Chamber)
4. Ozone Pump
3. Ozone Flow Control
5. Solids Drain
6. Sludge Otlet Pressurized Clean-
Out (Not Shown)
7. Solids Chamber Pressurized
Clean-Out (Not Shown)
1 Inlet Flowmeter
2 High Filter Pump Float
3 Transfer Pump Float
4 Pressure Gauge: Transfer Pump
5 Rain Water Overow
6 Rinse Water Oulet
7 Outlet To Ressure Washer
8 Fresh Water Makeup
9 Inlet From Sump Pump
10 Outlet Return To Pit
11 Orp Sensor Probe
12 Ph Sensor Probe
13 Ozone Pump
14 Sludge Outlet
15 Ozone Injector
16 Optional Return To Pit
17 Solids Separation Chamber
18 Oil Coalescing Cones
19 Solids Deection Cone
20 Diverter Tee
21 Top Separator Cone
22 Oil Separation Chmaber
23 Lid
24 Sludge Tub
25 Filter Bag
26 Power Indicator Light
27 Indicator Lisht Backwash Required
28 Backwash Switch
29 Sump Pump Switch (On/O󰀨)
30 Filter Pump Switch (On/O󰀨)
31 Transfer Pump Switch (On/O󰀨)
32 Ph/Orp Meters Switch (On/O󰀨)
33 Ph Pump Switch (On/O󰀨)
34 Orp Pump Switch (On/O󰀨)
35 Hour Meter
36 Orp Meter
37 Ozone Pump Switch (On/O󰀨)
38 Ph Meter
UNIT DESCRIPTIONS
FEATURES FRONT ISO & CONTROL PANEL - WCP-30-0M10 021722
background
Mi-T-M
WCP-SERIES Operator's Manual 15
70
69 VAVLE 13
68
67 66
50
51
VALVE 10
52
53
54 56 57
58
5955
VALVE 12
VALVE 11
61
62
65
64
63
39
40
41
42
43 44
47
45
46
VAVLE 8
49
48
VALVE 9
60
VALVE DESCRIPTIONS
8. Filter Control
9. Cartridge Filter Drain (Not Shown)
10. Polishing Filter
11. Waste Oil Release
12. Water Inlet Flow Control
13. Multi-Media Filter
UNIT DESCRIPTIONS
FEATURES REAR & TOP DOWN - WCP-30-0M10 021722
FEATURES FOR WCP-30
39 Outlet Y
40 High Sump Pump Float
41 Filter Flowmeter
42 Low Filter Pump Float
43 End Fork Lift Holes (6' Fork Required)
44 Filter Pump
45 Skid
46 Side Fork Lift Holes
47 Air Relief Valve
48 Orp Chemical Injector
49 Ph Chemical Injector
50 Polishing Filter
51 Pressure Gauge: Polishing Filter
52 Product Tank
53 Product Tank Overow
54 Transfer Pump
55 Pressure Tank
56 Ph Pump
57 Orp Pump
58 Recycled Wash Water
59 Control Panel
60 Ozone Generator
61 Waste Oil Decanter
62 Oil Skimmer
63 Anti-Siphon Device
64 Outlet Ring
65 Holding Tank Overow
66 Holing Tank
67 Pressure Gauge: Multo-Media Filter
68 Multi-Media Filter
69 Cartridge Filter
70 Pressure Gauge: Cartridge Filter
background
16 Mi-T-M
®
WCP-SERIES Operator's Manual
NOTE: Proper Attire is essential to your safety. It is advised to utilize whatever means necessary to protect eyes, ears,
and skin.
1. A Collection Pit System must already be an established structure before installing the WCP-Series water recycling
treatment system. A well designed pit system is critical for the proper operation of the recycle system. Consult your
Mi-T-M dealer for installation requirements.
2. Place the water recycling treatment system platform on a hard, level surface in an area free of ammable vapors,
combustible dust, gases or other combustible materials.
3. Set the unit so you have access to all four sides.
4. Do not place unit in an area:
a. with insu󰀩cient ventilation.
b. where environmental hazards (i.e. rain and snow) can come in contact with the water recycling treatment
system.
c. where the unit may freeze.
5. The water recycling treatment system is shipped with some union connections loosened to protect the unit from
shipping damage. Tighten all union connections at this time.
INSTALLATION
INLET & OULET LOCATION-WCP-071101-KS
Ref. Description WCP-10 WCP-20 WCP-30
A Rainwater Overow 11 3/4" 11 3/4" N/A
B Rinse Water Outlet 8 3/4" 8 3/4" N/A
C Pressure Washer Outlet 5 3/4" 5 3/4" N/A
D Fresh Water Inlet 2 3/4" 2 3/4" N/A
E Rainwater Overow N/A N/A 48"
F Rinse Water Outlet N/A N/A 51"
G Pressure Washer Outlet N/A N/A 54"
H Fresh Water Inlet N/A N/A 57"
J Inlet From Sump Pump 18 1/2" 18" 25"
K Outlet Return to Pit 21" 21 1/2" 28 1/4"
L Optional Outlet Return to Pit 35 1/2" 68" 74"
background
Mi-T-M
WCP-SERIES Operator's Manual 17
INSTALLATION
6. Use schedule 80 PVC slip connections.
a. Install the Sump Pump in the plumbing in between the Sump Pit and the unit. Install the Sump Pump close
to the Sump Pit to reduce priming time.
b. Install plumbing from the Sump Pit to the Sump Pump using minimum connection sizes of 1-1/2" for WCP-10
and 2" for the WCP-20 and WCP-30.
c. Install a check valve between the Sump Pit and the Sump Pump.
d. Install plumbing from the Sump Pump to the unit using 1-1/2" minimum plumbing.
e. Install plumbing from the Outlet Return To Pit to the Wash Water Catch Pit using a minimum pipe size of 2"
for the WCP-10 and 3" for the WCP-20 and WCP-30.
f. Install plumbing from the Sludge Tub to the Wash Water Catch Pit. Position the Sludge Tub so that the Sludge
Hose can be connected from the Sludge Outlet to the Sludge Tub.
7. Install the three oats in the Sump Pit. Allow a 2" tether and enough room for them to move freely without interfering
with the plumbing.
a. Float #1 Blue: Pit low level shut-o󰀨. Attach this oat 10" above the inlet.
b. Float #5 Red: Fresh water makeup. Height of this oat must be adjusted to the individual pit system.
c. Float #6 Green: Rain water overow. Height of this oat must be adjusted to the individual pit system.
NOTE: The above information is for reference only. Professional installers or architects may use this guideline to meet
specic site requirements.
SUMP PUMP-071101-KS
background
18 Mi-T-M
®
WCP-SERIES Operator's Manual
9. Make the following hose connections:
a. From a pressurized water supply to the Fresh Water Makeup.
b. From the Outlet to Pressure Washer to the pressure washer.
c. From the Rain Water Overow to a storage tank for further processing or disposal. DO NOT SEND THIS
WATER BACK TO THE WASH WATER CATCH PIT!
d. Connect the Sludge Hose to the Sludge Outlet and the Sludge Tub.
NOTE: In most cases, you must have a permit to legally dispose discharged water.
INSTALLATION
8. A qualied electrician must hook up the electrical system.
a. Verify the electrical supply at the power source is o󰀨.
b. Be certain all switches on the Control Panel are in the "OFF" position.
c. Run water tight conduit or cord from the Sump Pump and Floats to the Control
Panel.
d. Run water tight conduit from the local disconnect to the Control Panel.
e. The electrician will need to drill holes in the Control Panel for the conduit and/or
cord(s).
f. Make connections to the terminal strips as shown below.
FIELD WIRING DIAGRAM WCP 10-20-30 230V 1PH 041818 MLK
WARNING
RISK OF ELECTROCUTION!
TO REDUCE THE RISK OF ELECTROCUTION,
KEEP ALL CONNECTIONS DRY AND OFF THE GROUND.
background
Mi-T-M
WCP-SERIES Operator's Manual 19
Before proceeding, answer all the questions on this checklist. YES NO
CODES:
1. Does the electrical wiring meet all codes?
2. Does plumbing meet all codes?
LOCATION:
1. Is the unit located on a hard level surface free of ammable vapors,
combustible dust, gases or other combustible materials?
2. Is the unit located in a large ventilated area?
ELECTRICAL:
1. Is the unit properly grounded?
2. Does the power supply, voltage and amperage match the data plate?
PLUMBING:
1. Is the plumbing sized correctly?
2. Is the check valve installed before the Sump Pump?
3. Are all plumbing connections secured?
4. Are all hose connections secured?
GENERAL:
1. Have all operators using this unit read and understood this entire manual?
2. Has the unit been installed by qualied service people who followed the
instructions listed in this manual?
IF "NO" WAS MARKED TO ANY OF THESE QUESTIONS, CORRECT THE SITUATION BEFORE OPERATING.
PRE-OPERATION CHECKLIST
STOP
TO ENSURE YOUR WATER RECYCLE TREATMENT SYSTEM OPERATES
SAFELY AND EFFICIENTLY, COMPLETE THE PRE-OPERATION CHECKLIST
BEFORE PROCEEDING.
background
20 Mi-T-M
®
WCP-SERIES Operator's Manual
PREPARATION
PRESTART PROCEDURES:
1. Position the valves on the WCP water recycling treatment system in the "Start-up Mode".
-Water Inlet Flow Control Valve: Turn valve one rotation short of completely closed.
-Filter Control Valve: Turn valve one rotation short of completely closed.
-Multi-Media Filter Valve: Turn valve to "Filter".
-Polishing Filter Valve: Turn valve to "Filter".
-Cartridge Filter Drain Valve: Turn valve completely closed.
-Air Bleed Valve: Turn valve open.
-Oil Release Valve: Turn valve completely closed.
-Ozone Pump Valve: Turn valve open.
-Pressurized Clean-Out Valves: Turn valves completely closed.
2. Be certain all hoses are securely connected.
3. Be certain the incoming air tube to the Ozone Generator is not obstructed.
4. Be certain all switches on the Control Panel and Ozone Generator are in the "OFF" position.
5. Turn on the power supply. The Power Indicator Light should glow.
START-UP:
1. Ensure water supply to the Fresh Water Makeup is turned on and pit is lled with water. If the pit is not full, water
will ll the Product Tank and overow through the Product Tank Overow and back to the Sump Pit.
2. To prime the Sump Pump, remove the lid over the Basket Strainer and ll the Basket Strainer and the plumbing
from Sump Pit to the Sump Pump, then replace the lid.
3. Turn on the Sump Pump Switch; water will ow into the Clarier Tank.
4. Flow can be increased by opening the Water Inlet Flow Control Valve and reading the Inlet Flowmeter. Fill the
Clarier Tank.
5. After the water lls the Solids Separation Chamber, it will begin to ow through the Top Separator Cone and ll
the Oil Separation Chamber.
6. As water lls the Oil Separation Chamber, the Ozone Pump will prime.
7. When the Oil Separation Chamber is full, the water will begin to ow through the Outlet Ring and into the Outlet
Y.
8. The Outlet Y directs the water into the Holding Tank where it is ready to be processed.
9. As the water lls the Holding Tank, it will begin to ow out the Overow Drain at the top of the tank. At this point,
ow can be adjusted to the rated ow rate with the Water Inlet Flow Control Valve.
10. Ensure that the Ozone Pump Valve is open and turn on the Ozone System Switch located on the Ozone Generator.
The ozone system is working properly when air bubbles are seen in the Oil Separation Chamber. if no air bubbles
are observed, turn o󰀨 the Ozone System Switch and loosen the union after the Ozone Pump until the pump is
primed. (The Ozone Flow Control Valve is set at the factory and should not need adjusting.) The Ozone Generator
Switch can now be turned on.
11. Turn on the Filter Pump Switch. The Filter Pump will automatically turn o󰀨 when the Product Tank is full of
water.
12. As water ows to the lters, use the Filter Control Valve to adjust the water ow to the GPM rating of the Water
Treatment System. Check the Filter Flowmeter located ahead of the Multi-Media Filter.
13. Water will begin to ow from the Multi-Media Filter to the Cartridge Filter. As water ows through the Multi-Media
Filter, air will automatically bleed from the Multi-Media Filter to the Cartridge Filter.
14. Air will release from the Air Bleed Valve as the Cartridge Filter lls. Close the Air Bleed Valve when water begins
to exit from it. This indicates the Cartridge Filter is lled and water will begin owing to the Polishing Filter. Since
it may take some time for the air to bleed out of the Multi-Media Filter, occasionally open the Air Bleed Valve while
the Filter Pump is operating to relieve any air buildup. For optimum e󰀩ciency, the Air Bleed Valve may need to
be periodically opened to relieve any air that builds up in the Cartridge Filter during operation.
15. As water ows through the Polishing Filter, air will automatically bleed from the Polishing Filter to the Product
Tank.
16. When the Product Tank is full and the Filter Pump turns o󰀨, prime the Transfer Pump by opening the Outlet to
Pressure Washer valve until water exits.
17. Turn on the Transfer Pump Switch to allow water to ow into the Pressure Tank.
18. Water is now completely cycled in the system.
background
Mi-T-M
WCP-SERIES Operator's Manual 21
WLP-0009-112098-JJ
WLP-0008-112098-JJ
PREPARATION
pH AND ORP CONTROL SYSTEM:
Proper pH and ORP levels must be maintained in the pit to prevent growth of bacteria, algae, odors, etc. Water must be
chemically balanced to e󰀨ectively recycle. The e󰀨ectiveness of Safe 0
3
in the water depends on the pH level.
-The optimum pH level to add Safe 0
3
is 6.5 - 6.8.
-As the pH level rises to 7.5, about 5% more Safe 0
3
must be added to achieve the same ORP reading.
-At a pH level of 8.0 and above, a large amount of Safe 0
3
must be added to increase the ORP reading.
As excess water ows through the Ozone System , it moves past the pH and ORP Sensor Probes before returning
to the Oil Separation Chamber . The Sensor Probes analyze the pH and ORP levels in the water.
a. pH Sensor Probe. This probe analyzes the pH (acidity & alkalinity) in the water. If the water is too acidic (low
pH) the acid will breakdown the iron present in the water to a liquid form, thus causing rusty looking water in the
system. If the water is too alkaline (high pH) the bacteria killing potential of the ORP agent will be drastically
lowered.
b. ORP Sensor Probe. This probe analyzes the Oxidation Reduction Potential (ORP). This reading states amount
of bacteria killing agent in the water.
The probes analyze the pH and ORP levels of the water and display the readings on the digital pH and ORP Meters.
background
22 Mi-T-M
®
WCP-SERIES Operator's Manual
PREPARATION
INSTALLATION OF PH AND ORP PROBES:
1. Turn o󰀨 the Ozone System Switch and close the Ozone Pump
Valve.
2. Locate the probe grips in the Ozone System plumbing and
unscrew the nut from one of the grips.
3. Remove one of the probes (pH or ORP) from its storage
container. (Be certain to save the container for probe storage
during winterizing.)
4. Carefully slide the probe grip nut over the glass probe.
5. Gently push the probe through the probe grip approximately 2
inches and tighten the nut onto the probe grip.
6. Repeat process for the remaining probe.
7. Immediately open the Ozone Pump Valve to rell the plumbing
with water.
THE PROBES CANNOT BE ALLOWED TO DRY OUT.
8. Turn on the Ozone System Switch.
9. Turn on the pH/ORP Meters Switch.
CAUTION
RISK OF PROBE DAMAGE!
-DO NOT ALLOW PROBES TO BE EXPOSED TO AIR. ONCE PROBES ARE IN PLACE, TURN WATER
ON IMMEDIATELY.
-HANDLE PROBES CAREFULLY AS THEY ARE MADE OF GLASS.
-DO NOT ALLOW PROBES TO BE EXPOSED TO FREEZING ENVIRONMENTS. KEEP THE ORIGINAL
CONTAINERS IN WHICH THE PROBES WERE SHIPPED. THEY WILL BE NEEDED FOR PROBE
STORAGE DURING WINTERIZING.
ORP SENSOR PROBE
pH SENSOR PROBE
WLP-0006-110298-JJWLP-0007-112098-JJ
background
Mi-T-M
WCP-SERIES Operator's Manual 23
PREPARATION
PH CONTROLLER PROGRAMMING
pH controller will come programmed and on measure mode with the following parameters set.
Measure Mode: pH
• Temperature Compensation: 03 MAN (No use of a temperature probe, manually can adjust temperature but
this is normally is not required as long as temperature is in the 60°F-80° it has a small e󰀨ect on pH reading.)
• Manual temperature set at 70°F.
• 7.00 Bu󰀨er and 4.01 Bu󰀨er: Controller is calibrated on STAND using a 7 pH bu󰀨er solution or calibrator, then
a 4.00 bu󰀨er calibrator for SLOPE. This will never need to be changed.
• pH relay 1 selected for HI1: Relay 1 will be closed if the probe reads HIGH over the set point (+ 1/2) the
hysteresis. This relay will turn on the chemical pump, low pH chemical to be used to lower pH. Relay 1 can be
changed to LOW1 to work in the opposite direction; if probe reads below set point the chemical pump will turn
on to add high pH chemical.
• Set point 1 is 7.00: pH point at which (+,-) half the hysteresis, the relays will close to turn on chemical pump.
• Hysteresis is at 0.20: The range around the set point that the relays will turn on and o󰀨. At a set point of 7.00,
the relay will close between 7.10 and 6.90.
• Set point 2, Relay 2 and Hysteresis 2 is not used for pH controller.
For ORP controllers will come programmed and on measure mode with the following parameters set.
ORP CONTROLLER PROGRAMMING:
ORP controllers will come programmed and on measure mode with the following parameters set.
MEASURE MODE: ORP RMV
• Temperature Compensation: 03 MAN (No use of a temperature probe) does not a󰀨ect ORP reading.
• Manual temperature set at 70°F.
• 7.00 Bu󰀨er and 4.01 Bu󰀨er: Controller is calibrated on STAND using a 7 pH bu󰀨er solution or calibrator, then a
4.00 bu󰀨er calibrator for SLOPE. This will never need to be changed.
• Relay 1: Set for ORP RMV
• ORP relay 1 selected for LOW1: Relay 1 will be closed if the probe reads LOW under the set point (- ½) the
hysteresis. This relay will turn on the ORP chemical pump.
• Set point 1 is 350rmv: ORP point at which (+,-) half the hysteresis, the relays will close to turn on chemical pump.
• Hysteresis is at P10.0: The range around the set point that the relays will turn on and o󰀨. At a set point of 350mv,
the relay will close between 345mv and 355mv.
• Relay 2 is not used for ORP controller.
FRONT PANEL
The front panel consists of a 4-digit LCD display and 4 keys.
1. [ MODE ] key:
1a. In the Measure mode, this key will switch the display in sequence from pH, Temperature, ORP absolute mV,
ORP relative mV and back to pH again.
1b. In the Calibration/Setting mode, pressing this key for three seconds will move you back to the previous pa-
rameter in the case when recalibration / resetting is required.
2. [ UP ] key:
2a. In the Calibration mode, pressing this key will show the next possible option. In the Setting mode, pressing
this key will show the next possible option and increases the numeral increment.
2b. In the Measure mode, pressing this key and [ENTER] key at the same time, the unit will enter the Calibration mode.
3. [ DOWN ] key:
3a. In the Calibration mode, pressing this key will show the next possible option. In the Setting mode, pressing
this key will show the next possible option and decreases the numeral increment.
3b. In the Measure mode, pressing this key and [ENTER] key at the same time, the unit will enter the Setting mode.
4. [ ENTER ] key:
In any mode where the user can change the settings, pressing this key will save the new
settings. If no change has been made then pressing this key will just move the user to the next setting.
background
24 Mi-T-M
®
WCP-SERIES Operator's Manual
PREPARATION
LCD SCREEN
1. Major LCD display.
2. CAL – This icon will be displayed if the meter is in the Calibration/Setting mode.
3. HI1 & LOW1 – These icons, when displayed, indicate relay action and relay number.
4. HI2 & LOW2 –These icons, when displayed, indicate relay action and relay number.
5. °C – Temperature and unit display.
6. pH – Unit indicator.
7. STAND – This icon will blink before Bu󰀨er 1 calibration. The icon will stay on while Bu󰀨er 1 is being calibrated.
8. SLOPE – This icon will blink before Bu󰀨er 2 calibration. The icon will stay on while Bu󰀨er 2 is being calibrated.
9. 6.86 – The 6.86 bu󰀨er group: 6.86, 4.00, 9.18.
10. 7.00 – The 7.00 bu󰀨er group: 7.00, 4.01, 10.01.
11. ATC –This icon will be displayed when a temperature probe is connected.
12. MAN –This icon will be displayed when a temperature probe is not connected.
13. RmV – Unit indicator.
MEASURE MODE
Turning on the unit will always display the Measure mode. This instrument is designed to provide 4 distinct measurements:
1. pH – The degree of acidity or alkalinity of the solution.
2. Temperature – Current temperature of the solution.
3. ORP mV – A measurement of absolute ORP mV.
4. ORP RmV – A measurement of relative ORP mV. The o󰀨set value at the RmV calibration will be added to the ORP
absolute value to display the ORP relative value.
Note: ORP relative value range: ORP absolute value - 1000mV to ORP absolute value + 1000mV Pressing
[MODE] key in the Measure mode will cycle the display from the four modes above.
HI1 HI2 LOW1 LOW2
STAND
SLOPE
RmV
CAL
6.86 7.00
ATC MAN
pH
654321
13121110987
C
7. 00
ATC
pH
ATC
C
mV
RmV
MODE
MODE
MODE
MODE
background
Mi-T-M
WCP-SERIES Operator's Manual 25
PREPARATION
SETTINGS MODE
Pressing [DOWN] key and [ENTER] key at the same time, the meter will enter into the Setting mode.
1. Temperature compensation select:
Pressing [UP] key or [DOWN] key in this screen will cycle the display from 01 (Thermistor: 10k ohm), 02 (Resistor:
PT1000), 03 (Manual) modes above.
Select the preferred temperature compensation mode, press [ENTER] key to save, and enter the next setting screen.
PH BUFFER 1 SELECT:
Pressing [UP] key or [DOWN] key in this screen will cycle the display from 7.00, 6.86 bu󰀨er above.
Select the preferred bu󰀨er, press [ENTER] key to save, and enter the next setting screen.
Pressing [UP] key or [DOWN] key in this screen will cycle the display from 4.01, 10.01 (or 4.00, 9.18) bu󰀨er above.
Select the preferred bu󰀨er, press [ENTER] key to save, and enter the next setting screen.
Note: The pH buer 2 is either 4.01 or 10.01 if select 7.00 buer at pH buer 1 select screen. The pH buer 2 is
either 4.00 or 9.18 if select 6.86 buer at pH buer 1 select screen.
+ENTER
ENTER ENTER
ENTER
pH buffer 1 select
CAL
ATC
CAL
ATC
CAL
MAN
Temperature compensation select
pH buffer 2 select
ENTER
ENTER
ENTER
CAL
6.86
pH
CAL
7.00
pH
Buffer 1 7.00
Relay control parameters select
ENTER
CAL
7.00
pH
CAL
7.00
pH
ENTER
ENTER
Buffer 2 6.86
Relay control parameters select
ENTER
ENTER
ENTER
CAL
6.86
pH
CAL
6.86
pH
background
26 Mi-T-M
®
WCP-SERIES Operator's Manual
PREPARATION
RELAY CONTROL PARAMETERS SELECT:
Pressing [UP] key or [DOWN] key in this screen will cycle the display from pH, ORP mV ORP RmV modes above.
Select the preferred mode, press [ENTER] key to save, and enter the next setting screen.
Note: The relay will work with the choice of parameters.
Pressing [UP] key or [DOWN] key in this screen will cycle the display from HI, LOW modes above. Select the preferred
mode, press [ENTER] key to save, and enter the next setting screen.
Note: See “Controlling the relays ” page.
Relay 1 set point value:
Pressing [UP] key or [DOWN] key in this screen to adjust the value, press [ENTER] key to save, and enter the next
setting screen.
Buffer 2 select
Relay 1 HI/LOW select
ENTER
ENTER
ENTER
ENTER
RmV
CAL
CAL
pH
mV
CAL
Relay control paramelers select
Relay 1 set point value
ENTER
ENTER
ENTER
HI1CAL CALLOW1
Relay 1 HI/LOW select
Relay 1 hysteresis value
ENTER
ENTER
CAL
pH
background
Mi-T-M
WCP-SERIES Operator's Manual 27
PREPARATION
Relay 1 hysteresis value:
Pressing [UP] key or [DOWN] key in this screen to adjust the value, press [ENTER] key to save, and enter the next
setting screen.
Relay 2 High / Low select: Same as “Relay 1 work way select”
Relay 2 set point value: Same as “Relay 1 set point value”
Relay 2 hysteresis value: Same as “Relay 1 hysteresis value”
PH CALIBRATION MODE
The TX20 uses 2-point calibration for pH. The rst point must be 6.86/7.00, and the second point can either be 4.00/4.01
or 9.18/ 10.01.
In the pH Measure mode, pressing [UP] key and [ENTER] key at the same time to allow the meter to go to the pH Cali-
bration mode.
CONTROLLING THE RELAYS
1. ISOLATION VOLTAGE:
The maximum isolation voltage of the relay output contacts is 1500 VDC. The voltage di󰀨erential between the relay
output contacts and the load should not exceed 1500 VDC.
2. OUTPUT LOAD:
The current through the relay output contacts should not exceed 5 Amp at 115 VAC and 2.5 Amp at 230 VAC in order
not to cause permanent damage to the relay contacts. This rating is specied for resistive loads only.
3. RELAY ACTION, RELAY SET POINT AND HYSTERESIS VALUE:
If the relay action is set to HIGH, the relay will turn ON at (Set Point +1/2 Hysteresis ), and will turn OFF at (Set Point
-1/2 Hysteresis ).
If the relay action is set to LOW, the relay will turn ON at (Set Point -1/2 Hysteresis ), and will turn OFF at (Set Point
+1/2 Hysteresis ).
There are two Independent relays the user can bind to the pH, ABSOLUTE mV or RELATIVE mV mode. The user can
only bind the two relays to one reading mode at a time. The user can change this anytime by changing option at the
setting mode.
Note:
1. The ideal set point range for pH is 0.00 to 16.00 pH.
2. The ideal set point range for absolute mV is –2000 to 2000 mV.
3. The ideal set point range of for relative mV is -3000 to 3000 mV.
Relay 2 HI/LOW select
ENTER
ENTER
CAL
Relay 1 set point value
pH
Relay Action E󰀨ective RELAY-ON Set Point E󰀨ective RELAY-OFF Set Point
HI S.P. + (1/2 H.V) S.P. – (1/2 H.V)
LOW S.P. – (1/2 H.V) S.P. + (1/2 H.V.)
background
28 Mi-T-M
®
WCP-SERIES Operator's Manual
PREPARATION
OPERATION:
At this point the PH and ORP control system is ready for operation. The system will now read the PH and ORP of the
water and the metering pump will activate when the PH or ORP is out of the range of the desired set point.
NOTE: If the metering pump is activated but the rollers fail to spin, the rollers of the pump might be stuck. You
should be able to manually spin the roller by hand to get these started. Add lubricant to the rollers if the prob-
lem persists.
FINAL pH AND ORP SYSTEM SETUP:
1. Place the hoses from the pH and ORP Pumps into the Adjustment Chemicals.
a. The recommended pH chemical for this system is aluminum sulfate.
b. The recommended ORP chemical for this system is bleach or sodium hypochlorite at 5%.
2. Turn on the pH and ORP Pump Switches. Chemicals will be inserted into the water as necessary.
background
Mi-T-M
WCP-SERIES Operator's Manual 29
SETTING OF THE WATER RECYCLING TIMER:
1. Dormant water creates bacteria buildup and odor. If the water recycling
treatment system is going to be dormant for more than six (6) hours, a water
recycle mode should be setup.
2. The water recycling treatment system should be set to recycle in accordance
with the unit dormant time.
Example 1: If the unit will be dormant for approximately 10 hours, the recycle
time should be set to run for 3-4 hours half way between the
dormant time.
Dormant time: 8:00 p.m. to 6:00 a.m
Recycle time: 11:00 p.m. to 3:00 a.m.
Example 2: If the unit will be dormant for approximately 3 hours, the recycle
time should be set to run for 1 hour half way between the dormant
time.
Dormant time: 2:00 a.m. to 5:00 a.m
Recycle time: 3:00 a.m. to 4:00 a.m.
NOTE: If odor is still present, increase recycle times.
3. Disconnect power to the system and open the Control Panel. Located
inside the Control Panel , the water recycling timer consists of individual
pins which surround a 24 hour clock display.
a. Turn the dial until the arrow points to the correct time.
b. Each pin represents 1/2 hour of water recycling time.
c. Using your ngertips, pull the amount of pins needed for water recycling
time to correspond to the clock on the timer.
d. The water recycling treatment system will automatically recycle during
the set time.
4. Close the Control Panel and reconnect power supply.
WATER RECYCLING TIMER
WLP-0012-112098-JJ
PREPARATION
1. The water recycling treatment system is now ready to operate.
2. Ensure all switches on the Control Panel are on.
3. With the sump pump running, set Water Inlet Flow Control Valve so that
the Inlet Flowmeter reads the rated ow rate of the systems.
4. Oil Skimmer positioning must be done when water is owing into the
Clarier Tank at the rated ow rate.
a. Tilt the Oil Skimmer so that it just breaks the surface of the water.
b. When a thick layer of oil accumulates in the Waste Oil Decanter, place
a container below Waste Oil Release Valve and open the valve until
water begins to come out.
5. Monitor the system closely the rst few days to ensure smooth operation.
OPERATION
background
30 Mi-T-M
®
WCP-SERIES Operator's Manual
WASTE OIL DECANTER:
1. The Oil Skimmer removes the top layer of oil and water from the Oil Separation
Chamber and sends it to the Waste Oil Decanter.
2. As the Waste Oil Decanter lls with the oil/water mixture, the oil will oat to
the top while the water remains on the bottom.
3. The water then moves up the standpipe, through the Oil Decanter Outlet,
and back to the Wash Water Catch Pit to be recycled again.
4. As oil accumulates, it will have to periodically be removed from the Waste
Oil Decanter.
a. Place a 5 gallon bucket below the hose on the Waste Oil Release Valve
b. Open the Waste Oil Release Valve and allow oil to ow into the 5 gallon
bucket. Turn o󰀨 valve when water begins owing into the bucket.
c. Dispose of oil according to EPA Standard
SOLIDS COLLECTION AREA:
The solids collection area of the Solids Separation Chamber will need to be
cleaned occasionally to prevent overow of solids into the Holding Tank. Do not
use pressure washers while performing this maintenance.
1. Ensure the Sludge Hose is connected to the Sludge Tub and the Sludge
Outlet Assembly and a Filter Bag is secured in the Sludge Tub.
2. By opening the Solids Drain Valve, sludge from the Solids Separation Chamber
will enter the SludgeTub.
3. If the solids accumulated at the bottom of the Solids Separation Chamber
are unable to drain, open Valve 4 and Valve 5 to push the solids towards the
Sludge Tub. If the solids are still unable to drain, open Valve 6 and Valve 7 to
break up the solids on the inside of the Solids Separation Chamber. When
the solids from the Solids Separation Chamber is empted, close Valve 4,
Valve 5, Valve 6 and Valve 7.
4. As sludge is forced into the disposable Filter Bag, solids in the Sludge are
retained by the disposable Filter Bag and uids drain out into the area created
by the Riser Plate.
5. The remaining water drains out of the bottom of the Sludge Tub through Sludge
Tub Outlet and back to the Wash Water Catch Pit.
6. When the Filter Bag is lled with accumulated solids, loosen the Hose Clamp
used to retain the Filter Bag, tie the Filter Bag o󰀨 and dispose of in a manner
consistent with local and federal regulations.
7. To replace the Filter Bag, bunch up the neck and feed it through the Hose
Clamp, place the Hose Clamp and Filter Bag over the inside nipple on the
inlet coupling and tighten the Hose Clamp.
BACKWASHING OF FILTERS:
1. Backwashing removes debris from the lters and sends the sediments back to
the pit where they will settle. Always backwash the lters if the Indicator Light
or Audio Alarm turns on. The Multi-Media Filter Pressure Gauge should be
checked daily for pressure elevation. When the pressure di󰀨erence between
the Multi-Media Filter Pressure Gauge and Cartridge Filter Pressure Gauge
registers more than 10 PSI, the Multi-Media Filter needs to be cleaned even
if the Indictor Light is not lit.
2. Pressure washers cannot be in use when backwashing any lters.
3. When performing backwash maintenance, backwash the Polishing Filter
immediately after backwashing the Multi-Media Filter. When backwashing
is complete, be certain to clean the Cartridge Filter.
MAINTENANCE
CAUTION!
Filter Pump Switch must
be turned o󰀨 before
repositioning any valves
on the Filters! Failure
to do so can cause
equipment damage.
WCP-0027030700-WKB
WASTE OIL DECANTER
WCL-0026-030100-WKB
SOLIDS COLLECTION AREA
background
Mi-T-M
WCP-SERIES Operator's Manual 31
a. Multi-Media Filter & Polishing Filter:
1. Turn the Filter Pump Switch to OFF.
2. Set the Multi-Media Filter Valve to "Backwash".
3. Turn the Filter Control Valve one rotation short of completely closed.
4. Turn the Filter Pump Switch to ON.
5. Press the Backwash Switch until the Filter Pump turns on.
6. Use the Filter Control Valve to adjust the rate on the Filter Flow Meter as listed:
WCP-10 WCP-20 WCP-30
10 GPM 15 GPM 20 GPM
7. When the backwash water is the same color as the incoming water, the backwashing process is complete.
(Approximately 5 minutes.)
8. Turn the Filter Pump Switch to OFF.
9. Set the Multi-Media Filter Valve to "Filter"
10. Set the Polishing Filter Valve to "Backwash".
11. Turn the Filter Pump Switch to ON. If the Filter Pump does not turn on, press the Backwash Switch
until the Filter Pump turns on.
12. Set the Filter Control Valve as listed in #6, above. See "Caution" above.
13. Backwash approximately 5 minutes.
14. Turn the Filter Pump Switch to OFF.
15. Set the Polishing Filter Valve to "Filter"
16. Turn the Filter Pump Switch to ON.
17. Clean Cartridge Filter as explained below.
b. Cartridge Filter:
When the pressure di󰀨erence between the Cartridge Filter Pressure Gauge and the Polishing Filter
Pressure Gauge is more than 10 PSI, it is time to clean the Cartridge Filter.
1. Turn the Filter Pump Switch to OFF.
2. Open the Cartridge Filter Drain Valve to allow water to be released from the Cartridge Filter.
3. Open the Air Bleed Valve to allow air to displace the outgoing water.
4 When water is drained from tank, loosen knob on middle clamp assembly.
5. Remove clamp and pry o󰀨 the top portion of the lter housing.
6. Remove the Polyester Fiber lter(s).
7. Use a garden hose to spray clean the lter(s).
8. Rinse out the Cartridge Filter tank.
9. If lter(s) are in good condition, reinsert them into the Cartridge Filter. If excessive wear is noted, replace
with new lter(s).
10. Lubricate the o-ring with petroleum jelly and replace around the outside of the Cartridge Filter body.
11. Reinstall the tank lid.
12. Reinstall and tighten the middle clamp assembly, tighten knob completely.
13. Close the Cartridge Filter Drain Valve to stop water from owing out the bottom of the Cartridge Filter.
tank.
14. Turn the Filter Pump Switch to ON.
15. Leave the Air Bleed Valve open as the tank lls with water. Close completely when water begins to
emerge from the Air Bleed Valve.
CAUTION!
Do not set ow above chart. If ow is set too high, water will begin pushing the
ltering agent out with the backwash debris.
MAINTENANCE
CAUTION!
Risk of bodily injury! Filters may weigh up to 70 pounds
each. Use caution when lifting the lters.
background
32 Mi-T-M
®
WCP-SERIES Operator's Manual
MAINTENANCE
ACTIVE CARBON TEST:
To ensure the Polishing Filter is working e󰀨ectively, you should perform an active carbon test.
I. TEST PROCEDURE A: For systems with pH & ORP Control, your test kit will include test strips.
A. Following the directions included with the test strip kit, test the water in the Holding Tank.
1. The test strip should show chlorine present in the system.
2. If no chlorine is present, check the following:
a. The ORP Adjustment Chemical is empty. Replace.
b. The ORP Pump is turned o󰀨 or malfunctioning. Ensure the ORP Pump Switch is in the ON position.
Contact your local distributor if additional maintenance is needed.
c. If you are not using chlorine as an ORP control, you must refer to TEST PROCEDURE B to ensure the
carbon is still active.
B. With the Filter Pump operating, use a test strip to test the incoming water to the Product Tank.
1. The test should not show chlorine present in the system.
2. If chlorine is present, the carbon must be replaced. See REMOVING AND REFILLING MEDIA section pg.
21.
II. TEST PROCEDURE B: For systems without pH & ORP Control, your test kit will include a Carbon removal scoop,
4 oz. empty container, 2 oz. empty container, 2 oz. bottle of chlorine, Chlorine test paper with color chart. Contact
your local distributor if any parts are missing.
A. Turn o󰀨 the Filter Pump Switch.
B. Unscrew the six head bolts and remove the Polishing Filter Valve.
C. Remove the following items from the Polishing Filter tank in the order given:
1. Upper dispersing cup.
2. Small section of PVC.
3. Lower dispersing cup.
D. Fill the Carbon Removal Scoop with a sample of carbon from the Polishing Filter tank.
E. Add 2 oz. of the carbon sample into the 4 oz. empty container.
F. Fill the 2 oz. empty container with water.
G. To the water, add one drop of chlorine.
H. Follow the directions on the bottle of test strips. Dip a chlorine test paper into the 2 oz. container. The chlorine
reading should be at least 10 parts per million. If not, add another drop of chlorine.
I. Add the 2 oz. of chlorine/water solution to the carbon sample in the 4 oz. container.
J. Tightly cap the chlorine/carbon mixture and shake occasionally for 3 minutes.
K. Dip a new strip of chlorine test paper into the liquid part of the 4 oz. container. Do not dip the test paper into the
solid carbon as this will produce incorrect results. Read the directions on the bottle of test strips.
L. Check the reading against the color chart.
1. A reading of zero means the carbon is still active.
a. Reassemble the dispersing section of the Polishing Filter and replace the Polishing Filter Valve.
b. Turn the Filter Pump Switch on.
2. A positive reading means the carbon is inactive and must be recharged or replaced. Refer to pg. 18.
background
Mi-T-M
WCP-SERIES Operator's Manual 33
REMOVING & REFILLING MEDIA FROM THE MULTIMEDIA & POLISHING FILTER:
1. New media can be ordered from your local distributor using the part numbers listed below.
2. Be certain to wear proper attire such as goggles, gloves, coveralls, dust mask, etc. to protect eyes and skin.
3. Turn o󰀨 the Filter Pump Switch.
4. Remove the valve from the desired lter tank.
5. Remove the following items from the lter tank in the order given:
Upper dispersing cup, Small section of PVC, Lower dispersing cup.
6. Use a vacuum to remove the media from the lter.
7. Cover the PVC opening to prevent media from entering the laterals.
8. Ensure the lateral assembly remains centered and ush on the bottom of the tank and the layers are level when
pouring media into the lter tank.
9. Reassemble the dispersing section of the lter tank and replace its corresponding valve.
10. Turn on the Filter Pump Switch.
11. Dispose of used media according to EPA standards.
MAINTENANCE
Model Part number Description Quantity Weight (lbs.)
WCP-10-0M10 19-0557 24" MEDIA FILTER 1
33-0303 GRAVEL #3 100 LBS
33-0304 GARNET #12 100 LBS
33-0305 GARNET #50 100 LBS
33-0306 FILTER AG 50 LBS
19-0557 24" POLISHING FILTER 1
33-0302 ACTIVATED CARBON 2 110 LBS
WCP-20-0M10 19-0557 24" MEDIA FILTER 1
33-0303 GRAVEL #3 100 LBS
33-0304 GARNET #12 100 LBS
33-0305 GARNET #50 100 LBS
33-0306 FILTER AG 50 LBS
19-0557 24" POLISHING FILTER 1
33-0302 ACTIVATED CARBON 110 LBS
WCP-30-0M10 19-0559 36" MEDIA FILTER 1
33-0303 GRAVEL #3 300 LBS
33-0304 GARNET #12 200 LBS
33-0305 GARNET #50 300 LBS
33-0306 FILTER AG 100 LBS
19-0558 30" POLISHING FILTER 1
33-0302 ACTIVATED CARBON 165 LBS
background
34 Mi-T-M
®
WCP-SERIES Operator's Manual
MAINTENANCE:
1. Clean pH AND ORP probes every 1-2 months.
a. Shut o󰀨 sump pump, wait for drain line to dran and loosen aluminum strain relief around probe to remove.
b. Use water or vinegar and a soft cloth or Q-tip to wipe away build up on the probe.
c. Place probe back in line, with tip at center of piping. Tighten strain relief around probe. DO NOT OVERTIGHTEN.
Note: probes will be damaged if they are allowed to dry out. If they will be exposed to air for more than a few
hours keep tip submerged in water or the storage solution that comes with the probe.
Note: probes have a shelf life of about 1 year so it’s recommended to replace the probes yearly.
2. Calibration of pH meter. You should recalibrate the external meter 1 or 2 times a year. You should also always
recalibrate the meter when a pH probe has been replaced. Follow the calibration instructions below for the pH meter.
An electronic calibrator can be used in place of the bu󰀨er solutions.
MAINTENANCE
WATER TESTING:
Water chemical makeup should be tested on a weekly basis. With the Sump Pump operating, use a test strip, test
the incoming water to the Holding Tank. (Follow the directions given with your test strips.) Use the ow chart below
to check and correct the following:
1. pH: Acidity and alkalinity in the water. Low pH (acidic) will cause rusty looking water.
2. Alkalinity: Dissolvable salts in the water. Too much alkaline causes cloudiness and reduces lter life.
3. Calcium Hardness: Calcium in the water. Too much calcium creates scale buildup in coils of hot water pressure
washers.
4. *Free Chlorine: Chlorine which is not combined with dirt, oils, etc. Controls odor, bacteria and algae formation.
*If using chlorine as a water purifying agent.
WLP-0015-112398-JJ
background
Mi-T-M
WCP-SERIES Operator's Manual 35
MAINTENANCE
BUFFER 1 (STAND) CALIBRATION:
Enter into the pH calibration mode, the “STAND” icon will ash, the unit is ready to be standardized at the rst bu󰀨er.
Rinse the pH and ATC/Temp probes in distilled water and immerse them in the rst bu󰀨er solution (either 7.00 or 6.86).
Allow temperature reading to stabilize, then press “ENTER” key to calibrate. The “pH” icon will ash until the unit detects
a stable reading. Once the unit calibrates the rst point, the “SLOPE” icon will ash. The unit is ready to be sloped at
the second bu󰀨er.
BUFFER 2 (SLOPE) CALIBRATION:
Rinse the pH and ATC/Temp probe in distilled water and immerse them in the second bu󰀨er solution (either 4.00/4.01 or
9.18/10.01). Allow temperature reading to stabilize, then press “ENTER” key to calibrate. The “pH” icon will ash until the
unit detects a stable reading. Once the unit calibrates the second point and the unit will automatically exit the calibration
mode and goes to the pH Measure mode. Dual point calibration is complete.
Note: In the Setting mode (1. Temperature compensation select), select 03 (Manual temperature compensation
mode) if no temperature probe is being used. Press the [UP] key or [DOWN] key in the Manual temperature
compensation mode to adjust the value to that of the test solution temperature. Then calibrate buer 1 and
buer 2.
ORP CALIBRATION:
The model TX20 uses 1-point calibration for RmV. In the RmV Measure mode, pressing [UP]
key and [ENTER] key at the same time, the meter will enter into RmV calibration mode.
Rinse the ORP probe in distilled water and immerse it in the ORP standard solution, then press
[UP] or [DOWN] key to adjust the ORP value to that the ORP standard. Press [ENTER] key to
save. The unit beeps to indicate a successful calibration. Calibration is now complete and the
unit will automatically switch to the ORP relative mV Measure mode.
Buffer 2 calibration
+ENTER
ENTER
STAND
CAL
7.00
pH
STAND
SLOPE7.00
pH
HI2
STAND
CAL
7.00
pH
ENTER
Buffer 1 calibration
Measure mode
STAND SLOPE
CAL
7.00
pH
STAND SLOPE
CAL
7.00
pH
RmV normal mode
or
CAL
RmV
CAL
RmV RmV
+ENTER
background
36 Mi-T-M
®
WCP-SERIES Operator's Manual
MAINTENANCE
WINTERIZING:
If you must store your unit in an area where the temperature may fall below 32°F/0°C, you can protect your water recy-
cling treatment system by draining all water from the system.
1. Follow the backwashing/cleaning procedures outlined on pages 15-16 for the Multi-Media Filter, Polishing Filter
and Cartridge Filter, but DO NOT rell the Cartridge Filter.
2. Turn all switches on the Control Panel to the OFF position and disconnect power to the Control Panel.
3. Open the check valve near the Sump Pit and drain the water transport line. Drain Sump Pump.
4. Open check valve at the inlet and drain the inlet line.
5. Set the Multi-Media Filter Valve 3 and the Polishing Filter Valve 4 to "Winterize".
6. Remove drain plug from Multi-Media Filter and Polishing Filter.
7. Open the Cartridge Filter Drain Valve 5 and open the Air Bleed Valve. Break the unions on each side.
8. Remove the drain plug from the Filter Pump.
9. Remove the drain plug from the Transfer Pump.
10. Follow the procedures listed for the solids collection area in the maintenence section. Completely drain the Clarier
Tank.
11. Remove the pH and ORP Sensor Probes and place them in their original containers lled with deionized water.
Store at room temperature.
12. Drain the pH and ORP lines.
13. Store all chemicals at room temperature.
background
Mi-T-M
WCP-SERIES Operator's Manual 37
SUMP PUMP
Sump Pump will not run.
Sump Pump motor starts and
stops frequently.
Sump Pump runs, but there is
little or no water discharge.
TROUBLESHOOTING
SYMPTOM PROBABLE CAUSE REMEDY
Level Limit Switch in the
Holding Tank has ipped up.
Circuit overload/breaker has tripped.
Motor overload.
Motor is defective.
This is a common occurrence on
initial start-up while pits are lling.
Excessive water ow to reclaim unit.
Readjust.
Add water to the Sump Pit.
Replace.
Push Level Limit Switch down,
or remove excess water in the
Holding Tank.
Reset breaker or replace fuse at
power source.
Allow motor to cool. Motor will
automatically restart when cool.
Replace pump.
Allow pits to ll.
Turn valve clockwise to reduce ow.
Disconnect power and unclog impeller.
Allow motor to cool. Motor will
automatically restart when cool.
Expand size of pit.
Manually ll the inlet pipe with water.
Replace.
Cycle pump in one minute
increments several times to clear air
from pump.
Ensure wire size is capable of
handling the rated amperage of the
unit. If wire size is correct, contact
your distributor.
Ensure Float 1 is not caught in
plumbing.
Not enough water in the Sump Pit.
Float 1 is defective.
Floats are not adjusted correctly in
the Sump Pit.
Sump Pump impeller is clogged.
Motor overload.
There is an air lock in the Sump
Pump.
Sump Pit is not large enough.
Strainer basket in Sump Pump
is clogged.
Water level is below pump inlet.
Clogged impeller or worn pump parts.
Defective switch inside Float 1.
Pump is air locked.
Low voltage.
Clean, repair or replace
Contact your distributor.
Sump Pump will not turn o󰀨.
background
38 Mi-T-M
®
WCP-SERIES Operator's Manual
ELECTRICAL
No power at Control Panel.
Power Indicator Light is OFF.
Power failure to Control Panel.
Blown fuses inside Control Panel.
on step down transformer.
Check circuit breaker at power
source or contact your local
distributor.
Check fuses, replace if necessary.
If fuses are OK, contact your
distributor.
CLARIFIER TANK
Water will not ow into the Sump Pump is not turned on. Move Sump Pump Switch to
Clarier Tank. "ON".
Circuit breaker has tripped or is "OFF". Reset or turn breaker "ON".
High Sump Pump Float in Holding Check On/O󰀨 with voltmeter, repair
Tank is malfunctioning. or replace.
Strainer basket in Sump Pump is Clean, repair, or replace.
clogged.
Dirt is lodged in the check valve. Clean.
Sump Pump impeller is clogged. Disconnect power and clean.
Lines or valves contain frozen water. Allow to thaw. Inject with warm water.
water if necessary.
FILTERS
Indicator Light remains on after Debris is packed too tightly. Increase backwash ow to 5 GPM
backwashing. above the maximum listed on pg.16.
SHAFT SEALS
Water is leaking at pumps. Damaged stationary shaft seal. Seal ran dry. Ensure seal chamber
is lled with liquid.
Short seal life. Unexpected temperature and Replace.
chemical usage.
TROUBLESHOOTING
SYMPTOM PROBABLE CAUSE REMEDY
background
Mi-T-M
WCP-SERIES Operator's Manual 39
FILTER PUMP
Filter Pump will not run. Filter Pump Switch is o󰀨. Turn switch on.
Circuit overload/breaker has tripped. Reset breaker or replace fuse.
Motor overload. Allow motor to cool. Motor will
automatically restart when cool.
Filter Pump Switch is Replace switch.
malfunctioning.
Low Filter Pump Float or High Filter Check On/O󰀨 with voltmeter, repair
Pump Float is malfunctioning. or replace.
Filter Pump runs but there is no Plumbing is obstructed. Remove obstruction.
water discharge OR Filter Pump
cycles excessively.
Pump sucking air. Eliminate leaks and tighten all
connections on intake line.
Low water in Holding Tank. Increase ow by opening Water Inlet
Flow Control Valve 1.
Rain Water Overow is Reduce ow by adjusting solenoid on
discharging too much water. the Rain Water Overow.
Check valve is leaking or stuck in Clean or replace as necessary.
closed position.
Filters are dirty. Backwash lters. (See pg.15-16.)
Lines or valves contain frozen water. Allow to thaw. Inject with warm
water if necessary. Ensure the
Sump Pit remains above
freezing.
Pump impeller is obstructed. Disconnect power and clean.
Pump motor is operating below Contact your local distributor.
maximum RPM.
Filter Pump is hot or turns o󰀨. Multi-Media Filter is dirty. Backwash.
Low voltage. Ensure wire size is capable of
handling the rated amperage of the
unit. If wire size is correct, contact
your local distributor.
Motor overload. Allow motor to cool. Motor will
automatically restart when cool.
TROUBLESHOOTING
SYMPTOM PROBABLE CAUSE REMEDY
background
40 Mi-T-M
®
WCP-SERIES Operator's Manual
TRANSFER PUMP
Transfer Pump runs but there is Water is being used elsewhere. Reduce ow to other source or
low water discharge. contact your local distributor.
Low Transfer Pump Float is not Check On/O󰀨 with voltmeter.
functioning. Repair or replace.
Timer kicked in. Water is recycling Do not run pressure washers while
water is in timed recycle mode.
Rain Water Overow is Do not run pressure washers while
discharging back to pit. water is discharging.
Plumbing is obstructed or too small. Remove obstruction or use larger
plumbing.
Scale buildup in metal piping. Replace with plastic plumbing.
Transfer Pump cycles Solenoid valve(s) is open or stuck Fix Solenoid valve(s) or reduce ow.
excessively. open.
Pump sucking air. Eliminate leaks and tighten all
connections on intake line.
Bladder failure in Pressure Tank. Replace Pressure Tank.
Pressure switch malfunction. Adjust pressure settings.
Too low of pressure in the Pressure Increase pressure.
Tank.
Transfer Pump does not turn o󰀨. Pressure switch line is obstructed. Disconnect line and remove
obstruction. Replace.
Pressure switch is out of alignment. Realign or replace.
Pressure switch contacts are frozen. Replace if necessary.
Impeller is obstructed. Contact your local distributor.
TROUBLESHOOTING
SYMPTOM PROBABLE CAUSE REMEDY
background
Mi-T-M
WCP-SERIES Operator's Manual 41
SOLENOIDS
Solenoid valve won't turn on. Low or no water pressure. Turn o󰀨 water, switch solenoids
between valves. Turn on water. If
problem is corrected, replace faulty
solenoid.
No electrical contact to solenoid. Contact your local distributor.
Solenoid valve leaks when turned o󰀨. Solenoid is obstructed. Turn o󰀨 water, remove and clean
solenoid.
Damaged solenoid. Replace.
Solenoid o-ring is misaligned or Realign or replace.
damaged.
Diaphragm seat is dirty. Clean or replace.
Diaphragm is damaged. Replace.
ODOR
Excessive odor in water system. Not enough chemicals in the system Increase the pH and ORP set points.
to maintain water balance. (See pg.14)
Water remains dormant in the system Increase timer settings to recycle
too long causing bacteria buildup. water.
CHEMICALS
Excessive chemical usage. pH and ORP Meters are Recalibrate meters or change
calibrated incorrectly or faulty probes. probes.
Low chemical usage (with possible Chemical pumps are not working. Replace chemical hose inside pump.
odor.) Recalibrate pH and ORP Meters.
WATER FLOW
Air shoots from Water Outlet. This is a common occurrence while Air will stop shooting from the water
pump is priming. outlet when pump is primed.
Transfer Pump is sucking air at Eliminate leaks or tighten
suction inlet. connection.
Water will not turn o󰀨. Solenoid failure. Repair or replace.
TROUBLESHOOTING
SYMPTOM PROBABLE CAUSE REMEDY
background
42 Mi-T-M
®
WCP-SERIES Operator's Manual
OvEr
Undr
OvEr
OvEr
OvEr
Undr
TROUBLESHOOTING
pH/OPR DISPLAY TEMPERATURE DISPLAY DISPLAY MODE POSSIBLE CAUSE(S) [ACTION(S)]
pH > 16.00pH [Recalibrate], replace probe
pH > -2.00pH [Recalibrate], replace probe
a. Temperature > 120.0 °C [Bring bu󰀨er
solution to lower temperature.] [Replace
temperature probe.]
b. No temperature sensor. [Adjust the
manual temperature to -10~120 °C.]
a. Temperature > -10.0 °C [Bring bu󰀨er
solution to higher temperature.] [Replace
temperature probe.]
b. No temperature sensor. [Adjust the
manual temperature to -10~120 °C.]
Absolute ORP mV > +1999 mV
a. Bring solution down to lower ORP
b. Recalibrate
c. Replace probe
Absolute ORP mV > -1999 mV
a. Bring solution up to higher ORP
b. Recalibrate
c. Replace probe
-10.0~120.0 °C
-10.0~120.0 °C
OvEr
Undr
Temperature reading
Temperature reading
pH measure mode
pH measure mode
pH measure mode
pH measure mode
Absolute ORP mV or
relative ORP
Absolute ORP mV or
relative ORP
background
Mi-T-M
WCP-SERIES Operator's Manual 43
REPLACEMENT PARTS
DESCRIPTION REORDER PART #
Replacement Cartridge Filter for WCP-10 ........................ 19-0274
Replacement Cartridge Filter for WCP-20/30 ................... 19-0264
pH Sensor Probe .............................................................. 32-0538
ORP Sensor Probe ........................................................... 32-0540
Activated carbon ............................................................... 33-0302
Gravel ............................................................................... 33-0303
Garnet #12........................................................................ 33-0304
Garnet #50........................................................................ 33-0305
Filter Ag. ........................................................................... 33-0306
Test Strips ......................................................................... 33-0314
background
44 Mi-T-M
®
WCP-SERIES Operator's Manual
STATEMENT OF WARRANTY
Mi-T-M warrants all parts (except those referred to below) of your new WCP Water Recycling Treatment system
to be free from defects in materials and workmanship for One (1) Year from the date of original purchase.
Defective parts not subject to normal wear and tear will be repaired or replaced at Mi-T-M's option during the
warranty period. In any event, reimbursement is limited to the purchase price paid.
EXCLUSIONS
1. The motor is covered under separate warranty by its respective manufacturer and is subject to the terms
set forth therein.
2. Normal wear parts:
Seals Filters Gaskets
O-rings Packings Pistons
Valve Assembly Brushes Filtering Media
Sensors
3. Parts damaged due to:
-normal wear, misapplication, modications/alterations, abuse,
-operation at other than recommended speeds, pressures or temperature,
-the use of caustic liquids,
-chloride corrosion or chemical deterioration,
-uctuations in electrical or water supply,
-operating unit in an abrasive, corrosive or freezing environment.
4. Parts damaged by failure to follow recommended:
-installation, operating and maintenance procedures.
5. This warranty does not cover the cost of:
-normal maintenance or adjustments,
-labor charges,
-transportation charges to Service Center,
-freight damage.
6. The use of other than genuine Mi-T-M parts will void warranty. Parts returned, prepaid to Mi-T-M's
factory or to an Authorized Service Center will be inspected and replaced free of charge if found to be
defective and subject to warranty. There are no warranties which extend beyond the description of the
face hereof. Under no circumstances shall Mi-T-M bear any responsibility for loss of use of the unit,
loss of time or rental, inconvenience, commercial loss or consequential damages.
background
Mi-T-M
WCP-SERIES Operator's Manual 45
background
46 Mi-T-M
®
WCP-SERIES Operator's Manual

Specifications