background
• I n s t a l l a t i o n & S e t u p
• H o w T o D r a i n / F i l l
• P l u m b i n g & V a l v e s
• E l e c t r i c a l
• A p p C o n n e c t i o n
• C o n t r o l P a n e l
• W a t e r C a r e
• F i l t e r R e p l a c e m e n t
• R e m o t e - C h i l l e r S e t u p
• S a f e t y P r e c a u t i o n s
Contents
Click any item below to navigate directly to that section.
4
5
6
1 3
1 5
1 7
1 8
2 0
2 2
2 4
background
Product Dimensions
Hyperpod Pro Owners Guide 3
background
Installation & Setup
4
Site requirements
Place the Hyperpod Pro and Hyperchiller on a solid, level, waterproof surface.
Maintain space surrounding the ice bath as detailed in the roughing-in image below.
The cord is 5 ft. long. If you plan to use an extension cord, use a 12-gauge.
Electrical Outlet
Voltage
Amperage
Non-GFCI Receptacle Recommended*
120V
Dedicated 20A Circuit
*Unit includes integrated GFCI protection. It is not suggested to use in conjunction with a GFCI-protected outlet.
This will create a situation prone to nuisance tripping*
Note: chiller can be placed remotely, up to 40 feet away from tub, and connected via 2 water lines. Choose
between Colderatti insulated water lines or dedicated plumbing lines (See ‘Remote-Chiller Setup’ for details).
Plumbing Requirements: The unit is designed for self-contained, freestanding operation with no permanent
plumbing required. Unit may be operated by draining/filling with a standard hose. Water supply and floor drain
are recommended for an integrated setup, but entirely optional.
Hyperpod Pro Owners Guide
3" Min
4" Min
24" Min
Fan exhaust clearance
Water Supply
Outlet (120V / 20A)
background
5
Drain/Fill Without Plumbing:
To Fill:
Using a garden hose, fill the tub with water until the water level
reaches the middle of the skimmer.
*Plumbing is optional. For drain and fill plumbing
instructions, see the next page.
To Drain:
Attach a hose to the drain valve, then open the valve to drain.
If you have an automatic water pump:
• Connect a garden hose to the top port of the automatic water pump.
• Submerge the pump fully in plunge basin until it rests on the bottom.
• Route hose to drain location, plug in pump. Monitor water level.
Hyperpod Pro Owners Guide
background
50"
(1270mm)
6
Drain/Fill With Plumbing:
*refer to next page for precise drain/fill valve locations
1. Drain valve: 1" NPT stainless steel thread. Connect to nearby floor drain.
2. Fill valve: 1" NPT stainless steel thread. Connect to water supply.
Floor Drain
Water Supply
Indoor Installations Only: Install a vacuum breaker to the water supply pipe. Locate the vacuum
breaker 50″ (1270 mm) from the floor to achieve a height of 6″ (152 mm) above the bath rim.
ASSE 1022
Vacuum Breaker
Hyperpod Pro Owners Guide
Drain Outlet (two-way valve)
background
7
Hyperpod Pro Valve Specifications:
Hyperpod Pro Owners Guide
background
A
B
C
D
C
B
I
N
L
E
T
O
U
T
L
E
T
A
8
Attach stainless steel shutoff valves to the 2 remaining ports.
Attach two-way valve to the 2 and 3 hydraulic connection ports.
nd rd
1. Connect Valves and Pre-Filter:
• Twist water OUT and water IN valves to the ON position.
• Shut DRAIN and FILL all valves to the OFF position.
(ON position = straight, OFF position = sideways).
Attach pre-filter to the Hyperchiller INLET. Ensure the rubber o-ring
gasket is present before you screw it on.
Hyperchiller: backside
B
Hyperpod Pro Owners Guide
background
Connect one water line from the Hyperchiller OUTLET Water IN.
Connect second water line from the pre-filter on the INLET Water OUT.
D
9
2. Connect Water Lines:
Confirm pre-filter is attached to the Hyperchiller INLET.
Confirm the DRAIN and FILL shutoff valves are on the tub and
twisted to the OFF position.
A
B
C
D
Hyperchiller OUTLET
Hyperchiller INLET
A
B
C
D
Hyperpod Pro Owners Guide
Water IN
1" NPT
The drain outlet on the Water OUT two-way
valve can be plumbed to a sanitary septic
line or routed to a nearby floor drain for full
water emptying. A twist ball valve
opens/closes the drain.
(Optional) The fill valve can be
connected to a water source for easy
and controlled filling of the tub.
Water OUT
1" NPT
Open the two-way
valve to drain
FILL
1" NPT
background
10
3. Fill With Water:
Fill the Hyperpod Pro until water is midway up the surface skimmer.
Minimum fill
Hyperpod Pro Owners Guide
background
A
B
C
D
F
A
B
E
Water must be
above minimum fill
*Failure to follow these precautions may damage the machine and void warranty.
4. Before turning on your cold plunge:
11
The water level must be above minimum fill, midway up the skimmer.
Verify the clear filter canister is securely hand-tightened to the chiller,
and the filter is inside, straight and securely seated.
Verify the Water IN and Water OUT shut-off valves are straight, in the
ON position (next page).
Ensure the sediment pre-filter is securely connected (next page).
Ensure the two water lines are properly connected to the tub and
chiller, and in the correct orientation (page 9)
Ensure the rubber o-ring seals are in place inside the 2 water cables and
the pre-filter (next page).
Hyperpod Pro Owners Guide
filter inside
hand-tightened
straight & secure
background
12Hyperpod Pro Owners Guide
C
C
D
OFF Position
ON Position
E
background
13
5. Plug In:
Before plugging in your Hyperchiller, make sure all items in Step 4:
Before turning on your cold plunge are fully completed and verified.
Plug your Hyperchiller into a standard 120V outlet. The outlet must
be on a dedicated 20A (minimum) circuit.
NEMA 5-20, (3-pronged
standard outlet)
120V, 20A
The machine includes built-in GFCI protection, so an additional external
GFCI is not necessary and may cause nuisance tripping.
Use only a 12-gauge extension cord if needed.
Hyperpod Pro Owners Guide
background
14
6. Set Temperature:
UP
DOWN
SET
POWER
Power on the Hyperchiller by pressing the POWER button.
Press and hold the UP & DOWN buttons at the same time to toggle
lock/unlock (a lock icon will show the lock status).
Allow system 1 hour to reach the target temperature.
Press the SET button (the temperature will start flashing on the control
panel) and use the UP/DOWN buttons to set temperature.
Hyperpod Pro Owners Guide
background
15
7. Pair your Hyperchiller with the app:
Download the Smart Life app.
Press and hold the UP & DOWN buttons at the same time to
toggle lock/unlock (a lock icon will show the lock status).
Hold the SET button for 7 seconds. Let go. You will hear a beep
and see the WiFi icon flash.
Press “Add Device” on the app, and the chiller will auto-connect.
App Store
Google Play
UP
DOWN
SET
POWER
Hyperpod Pro Owners Guide
background
16
Setup is complete!
Continue reading for instructions for operation, water care, cleaning,
filter replacements, and remote chiller placement
Hyperpod Pro Owners Guide
background
17
Control panel
POWER
SET
DOWN
UP
• Press POWER button once to turn on. Press once to turn off.
• Press and hold SET button for 7 seconds then release to enter pairing for app connection.
• Press and hold UP and DOWN buttons to toggle lock/unlock. A lock icon will appear to show lock
status. When locked, you cannot change the temperature or power off.
• Press the UP and DOWN buttons to change temperature.
Hyperpod Pro Owners Guide
background
18
Water Care & Maintenance:
Everything you need for water care in one package:
6-month maintenance kit (Residential)
6-month maintenance kit (Commercial)
Hygiene Tip: A quick rinse/shower before use removes oils and impurities –
preserving water quality, extending time between water replacements, and
minimizing overall maintenance.
Initial Fill-Up
4oz Colderatti water clarifier
Daily Maintenance
1/2oz Colderatti water clarifier
Monthly Maintenance
• Replace water with fresh water
• Replace the filter
• Rinse the pre-filter
Quarterly Deep Clean¹
Every 3 Months, deep clean
Initial Fill-Up
4oz Colderatti water clarifier
Daily Maintenance
1oz Colderatti water clarifier
Monthly Maintenance
• Replace water with fresh water
• Replace the filter
• Rinse the pre-filter
Quarterly Deep Clean¹
Every 3 Months, deep clean
Residential Water Care
If your Hyperpod Pro lives at
home, follow these care
instructions to keep water clean,
clear, and at peak performance.
Commercial Water Care
While commercial settings require
more frequent care, you can
extend the interval between water
replacements to 4–8 weeks by
following our protocol and best
practices, and by integrating our
auto-sanitizer system. This ensures
maximum uptime for your facility.
¹Deep cleaning is recommended for optimal performance, cleanliness, and
longevity of the machine. Instructions on next page.
Hyperpod Pro Owners Guide
background
19
Deep clean your plunge
We recommend deep cleaning your plunge every 3 months, for optimal
performance and longevity of the machine.
1. Drain all water and refill with clean water to 1/3 capacity.
2. Add 2oz (1/4 cup) food-grade citric acid*
3. Turn the Hyperchiller on and set the temp 75ºF.
4. Let the water cycle for 15 minutes with the citric acid solution.
5. Turn the Hyperchiller off and drain the tub fully.
6. Rinse the inside basin with warm water and a clean microfiber.
7. Run a final flush: fill with clean water to 1/3 capacity and turn the
Hyperchiller on for 5 minutes. Then turn off and drain water fully.
8. Replace the filter with a new filter. Deep clean is finished.
*Citric acid is a natural descaler that breaks down mineral deposits, biofilm,
and tarnish from the inside surface of the system—ideal for naturally flushing
your system and restoring it to a like-new condition, while leaving the stainless
steel more corrosion-resistant and with a visibly cleaner and brighter finish.
Cleaning requirements
Follow these best practices for regular cleaning and care to keep your
Colderatti stainless steel system in peak condition.
Water care: use Colderatti water clarifier regularly and replace filters as
required to keep water clean, clear, and free of oils and debris.
Stainless steel:
Clean stainless steel surfaces with a soft cloth and mild degreaser (dish
soap).
For tough mineral spots or stains, wipe stainless steel with warm water
and food-grade citric acid, then rinse.
Always rinse and dry surfaces after cleaning.
Use only soft microfiber cloths—never abrasive scrubbers.
DO NOT mix citric acid or hydrogen peroxide with other cleaning
chemicals.
Hyperpod Pro Owners Guide
background
20
Replacing the filter
Replace the filter once per month for optimal performance and
longevity of the machine.
• Unscrew the clear filter canister.
• Remove the old filter, empty the water from the canister, replace
with new filter. Screw in.
1
2
3
4
5
remove old filter
insert new filter
Hyperpod Pro Owners Guide
background
21
Water Testing
If you choose to test your water using water test strips, expect each
parameter to fall within the ideal ranges below:
1. Free Chlorine or Bromine: 0ppm
2. pH: 7.2–7.8
3. Total Alkalinity: 80–120 ppm
4. Calcium Hardness: 150–250 ppm
5. Total Dissolved Solids (TDS): under 1,500 ppm
6. Cyanuric Acid: 0 ppm
7. Oxidation-Reduction Potential (ORP): 500–750 mV
Note: The parameters above are specifically for oxygen-based, chemical-free
sanitation. If you utilize chlorine-based sanitation, these values will differ – most
notably, Free Chlorine should typically be maintained between 1–2 ppm.
Expected Results After 2 Weeks of Daily Use:
With proper daily water care, pH, Alkalinity, Hardness, and TDS levels typically fall
within 90–95% of ideal ranges. Results may vary based on user hygiene, adherence
to water care routines, and the quality of your initial water source.
Hyperpod Pro Owners Guide
background
22
Remote-Chiller Setup:
1. Distance Requirements:
Max vertical lift: 15 ft
Max run length (vertical + horizontal): 40 ft
Make sure the chiller is placed within these limits.
2. Connect Water Cables (IN/OUT):
If connecting through wall ports:
Label wall lines as IN/OUT clearly to avoid confusion.
Hyperchiller INLET
→
connects to tub OUT (bottom) valve
Hyperchiller OUTLET
→
connects to tub IN (top) valve
• All plumbed water lines must be 1" with minimum 1/2" thick insulation
sleeve for thermal efficiency. Lines must terminate in 1" male NPT.
4. Prime the INLET Line:
Use a hose to push water into the INLET cable and remove air.
Fill the filter chamber with water before powering on.
3. Ensure Proper Ventilation:
Chiller must have 24" clearance on fan end.
5. Final Checks Before Powering On:
Review Step 4 (Page 11) for full checklist.
If chiller is placed in enclosed area, it must have (either):
At least 2 passive vents (one vent next to Hyperchiller fan out, one
vent opposite, allowing adequate passive airflow) OR
Inline duct fan (400 CFM+) high, and passive vent low, near chiller.
An open area or well-ventilated room with natural airflow is ideal for the
chiller and requires no additional venting or fan system.
*See next page for drawings
Hyperpod Pro Owners Guide
background
23
Remote-Chiller Setup Drawings
Any water lines running through
walls or long distances (e.g. a 1"
copper pipe running 20 feet to
another room) must be wrapped
in a 1/2" thick (minimum)
insulative sleeve. This prevents
temperature loss and ensures
proper system performance.
The chiller should always be
placed at or below the level of
the tub and never above.
Hyperpod Pro Owners Guide
15ft max vertical lift
A <= 15
40ft max run length
A+B+C <= 40
A
B
C
Hyperpod Pro tub
Hyperchiller
Top View
Side View
A
background
24
Safety Precautions:
No children or pets – never allow unsupervised access. Secure the cover when not
in use.
No alcohol or drugs – these can drastically increase the risk of unconsciousness,
drowning, or hypothermia.
Know your limits – sudden cold immersion can trigger cold shock or hypothermia.
Always use under supervision until you know your body’s response.
Electrical safety – only use a dedicated 20A, 120V circuit with GFCI protection;
keep all outlets and devices 5 feet away.
Do not modify electrical components – only qualified technicians should access
internal electronics. Tampering can lead to electric shock, fire, or system failure.
Consult Your Doctor – especially if pregnant, have heart conditions, blood
pressure issues, diabetes, or are taking medication that may cause drowsiness.
Use with supervision if needed – those with reduced physical, sensory, or mental
ability should only use the plunge under supervision.
Service & Troubleshooting:
Error Code
Reason
Solution
CLN
Low Flow Rate
Clean the filter
FL
Flow Issue
Possible solutions:
• Confirm both water valves are in the ON position (straight).
• Confirm seal rings are on the inside of the water hoses.
• Reset the Hyperchiller. Power it off and on.
Freezing Conditions – Operating or storing this equipment in temperatures below
32°F (0°C) strictly voids the warranty. While the Hyperchiller is equipped with
internal freeze protection as a safety measure; it is not rated for operation or
storage in freezing environments. The system must remain powered on at all times
to utilize its internal safety sensors; if the unit loses power or is turned off in cold
conditions, it must be drained and moved indoors immediately. Any damage
resulting from freezing temperatures – including damage resulting from power
failure or outdoor placement – is at the user’s own risk and is strictly excluded from
warranty coverage.
Hyperpod Pro Owners Guide
background

Specifications

Indexed Terms: Cold Plunge, Cold Therapy

Colderatti CLDRTI-PLNG-HYPERPOD-PRO Questions and Answers

Questions and Answers

Related Products