X-Sense XR0A-SR Radon Detector for Basement, Zero Lab Fees,

Product's Documents

Below are documents related to this product, you can read online or download:
XR0A-SR photo

User Manual

This is the main product document for model XR0A-SR.

The file format is pdf, 16 pages, you can download this manual here .

background
F800004000278 V1.0
Radon Alarm
User Manual
XR0A-SR
Make Invisible Risks Visible
background
1 Introduction
2 Get to Know Your Device
3 How to Use Your Device
4 Other Features
5 Troubleshooting
6 Daily Maintenance
7 Statement
8 Manufacturer and Service Information
01
03
08
15
19
23
24
26
Contents
Note: Scan the QR code on the left to view the full digital
manual (including appendix).
background
01 02
This user manual contains important information regarding the installation and
operation of your radon alarm. Please take a few minutes to thoroughly read
this manual, which should be saved for future reference. If you are installing the
radon alarm for use by others, you must leave this manual—or a copy of it—
with the end user.
1 Introduction
This device is a battery-powered, standalone radon alarm for domestic use. It
is easy to use, accurately outputs radon data, and provides online-generated
reports for convenient record-keeping.
⚠
WARNING
1. READ THE INSTRUCTIONS CAREFULLY BEFORE OPERATING OR SERVICING.
2. THIS PRODUCT IS INTENDED FOR USE IN ORDINARY INDOOR LOCATIONS OF
FAMILY LIVING UNITS.
3. DO NOT DISASSEMBLE THE DEVICE YOURSELF. IT CONTAINS SENSITIVE
COMPONENTS THAT HAVE BEEN CAREFULLY CALIBRATED BEFORE LEAVING
THE FACTORY. DISASSEMBLY MAY LEAD TO DISTORTED DETECTION RESULTS!
What is Radon
Radon is a cancer-causing, radioactive gas.
You can’t see radon. And you can’t smell or taste it. But it may be a problem in
your home. Radon is estimated to cause many thousands of deaths each year.
That’s because when you breathe air containing radon, you can get lung cancer.
Only smoking causes more lung cancer deaths. If you smoke and your home
has high radon levels, your risk of lung cancer is particularly high.
Radon can be found everywhere.
Radon comes from the natural (radioactive) breakdown of uranium in soil, rock,
and water, and gets into the air you breathe. Radon can be found everywhere. It
can enter any type of building—homes, offices, and schools—and result in high
indoor radon levels. However, you and your family are most likely to experience
the greatest exposure at home, where you spend most of your time.
⚠
WARNING
1. Radon measurement can help assess the risk of lung cancers. The likelihood
of lung cancer caused by radon primarily depends on:
a. The radon levels in your home.
b. The amount of time spent at home.
c. Whether you’re a smoker or have smoked in the past.
2. Smoking combined with radon exposure is a particularly serious health issue.
If you smoke or have smoked in the past, the presence of radon significantly
increases the risk of lung cancer. However, quitting smoking and reducing
radon levels in your home can lower the risk of lung cancer.
3. Measurements can be taken at any time of the year. The longer the detection
period, the more accurate the data. If the testing period is less than 72 hours,
avoid testing during abnormal or severe weather conditions in the area. In
case of severe weather during testing, retesting may be necessary.
4. Although some buildings react differently to seasonal changes,
background
03 04
measurements taken during continuous heating operation (day and night)
are more likely to clearly describe the radon hazards.
2 Get to Know Your Device
2.1 What’s Inside the Box
823
4 5 6 7
Pull
4
3
1
2
6
5
Recommended ≥ 7 Days
“Maintenance Recommended” Icon
Refer to this value and compare it with the table below.
Scan this QR code
Anti-slip strips
Date Sticker
(5 pieces; manually filled
with the start time of detection)
LCD After the First Power-On or Data Reset
Verification Code
Transparent
Screen-Icon Sticker
(Apply to the back only; avoid side air intake area)
User Manual
Radon Alarm
(Pre-installed removable AA battery × 3)
The device is self-testing.
LCD Displays Peak Level
Remove the insulating film.
1
2.2 Understanding the Buttons and Screen Interface
823
4 5 6 7
Pull
4
3
1
2
6
5
Recommended ≥ 7 Days
“Maintenance Recommended” Icon
Refer to this value and compare it with the table below.
Scan this QR code
Anti-slip strips
Date Sticker
(5 pieces; manually filled
with the start time of detection)
LCD After the First Power-On or Data Reset
Verification Code
Transparent
Screen-Icon Sticker
(Apply to the back only; avoid side air intake area)
User Manual
Radon Alarm
(Pre-installed removable AA battery × 3)
The device is self-testing.
LCD Displays Peak Level
Remove the insulating film.
1
LCD: Displays the device information.
LED: Flashes yellow periodically when the battery is low or there is a
malfunction. For more details, please refer to “Troubleshooting”.
Peak Level Button: Click to view the maximum radon level within the
recorded interval; during the peak level display period, press and hold the
button for 3 seconds or more to clear the current peak level and start a new
interval (only clears the peak value; other monitoring data will not be cleared).
Backlight Button: Click to illuminate the LCD backlight for 5 seconds
(backlight cannot be activated once the device enters low battery mode).
Reset Button: Press and hold the button for 3 seconds or more to clear all
data (return to factory settings), then the device will restart. Please proceed
background
05 06
with caution, and it is recommended to perform this action before starting a
new detection cycle.
Air Intake Area: Where radon enters the devices. Do not block this area
during monitoring.
823
4 5 6 7
Pull
4
3
1
2
6
5
Recommended ≥ 7 Days
“Maintenance Recommended” Icon
Refer to this value and compare it with the table below.
Scan this QR code
Anti-slip strips
Date Sticker
(5 pieces; manually filled
with the start time of detection)
LCD After the First Power-On or Data Reset
Verification Code
Transparent
Screen-Icon Sticker
(Apply to the back only; avoid side air intake area)
User Manual
Radon Alarm
(Pre-installed removable AA battery × 3)
The device is self-testing.
LCD Displays Peak Level
Remove the insulating film.
1
Long-Term Average (the main data): Displays the average value of all
radon monitoring data since power on or data reset, used to determine
whether further action is needed. The maximum duration for long-term
monitoring is 999 days, starting from "000D" (Day). After 24 hours, it will
display “001D” (Day). The long-term average is updated every 24 hours.
Short-Term Average (the auxiliary data): Reflects short-term variations
over different intervals. A total of 4 intervals are displayed in a rolling manner,
representing the average radon levels over the past 1/7/30/90 days (if the total
detection days are insufficient, the corresponding short-term interval will not
be displayed). The short-term average is updated every hour except for
the "01D" interval, while the other settings are updated every 24
hours.
Value Change Trend: Indicates the recent fluctuations in radon
concentration. “ ” represents a significant increase; “ ” represents a significant
decrease; “ ” represents no significant fluctuation.
“Peak Level” Icon: The icon will appear after clicking the “Peak Level”
button, indicating that the displayed data is the maximum value for the
recorded interval.
823
4 5 6 7
Pull
4
3
1
2
6
5
Recommended ≥ 7 Days
“Maintenance Recommended” Icon
Refer to this value and compare it with the table below.
Scan this QR code
Anti-slip strips
Date Sticker
(5 pieces; manually filled
with the start time of detection)
LCD After the First Power-On or Data Reset
Verification Code
Transparent
Screen-Icon Sticker
(Apply to the back only; avoid side air intake area)
User Manual
Radon Alarm
(Pre-installed removable AA battery × 3)
The device is self-testing.
LCD Displays Peak Level
Remove the insulating film.
1
“Testing” Icon: Indicates that the device is performing radon detection. If
this icon stops flashing, please restart the device or contact us.
“Maintenance Recommended” Icon: When this icon appears, it indicates
that an excessive radon concentration has been detected.
“Battery” Icon: Indicates the current battery level of the device. When this
icon (“ ” or “ ”) appears, please replace the battery promptly.
Measurement Units: Switch the unit of the current radon data (pCi/L or
Bq/m
3
) by double-clicking the “Peak Level” button. In the United States,
recommend to use the unit “pCi/L” while in Europe or Canada, the unit “Bq/
m
3
” is recommended.
background
07 08
2.3 Technical Specifications
Power Supply
1.5 V (
⎓
) AA alkaline battery × 3 (replaceable)
Battery Life 2 years
Warranty Period 5 years
Sampling Method Passive diffusion chamber
Measurement Method Continuous alpha spectrometry
Detection Range
0–500 pCi/L
0–9999 Bq/m
3
Accuracy/Precision (95%
Confidence)
< ± 10% @5.4 pCi/L (200 Bq/m
3
) after 7 days
Sensor Sensitivity 1.25 cph (counts per hour) per 1 pCi/L (37 Bq/m
3
)
Detection Stabilization
Time
Reliable data is obtained within 4 to 24 hours (the
higher the concentration, the faster the data is
available). The longer the testing period, the more
accurate the results. It is recommended to perform a
single detection for at least 7 days.
Data Update Cycle
1 hour/24 hours (Short-term average and long-term
average have different update cycles).
Operating Temperature 14–122°F (-10–50°C)
Operating Relative
Humidity
≤ 85% RH (non-condensing)
Dimensions (unit
excluding packaging)
3.23 × 3.15 × 2.79 inches (82 × 80 × 70.8 mm)
Weight (unit excluding
packaging)
10.3 oz. (292 g)
3 How to Use Your Device
3.1 How to Power On/Off
Power On: After installing the battery or removing the insulating film, the
device will automatically power on. The LCD will display all content (with
backlight on), accompanied by flashing yellow during this period. Once
powered on, the device will perform a self-check. The LCD will show “CAL” along
with a continuously increasing value. During this process, the device will check
its core components. If an issue is detected, the corresponding error code will
be displayed (refer to “Troubleshooting” for more details). If no issues are
found, the device will automatically enter standby mode and begin testing
without any further setup required.
823
4 5 6 7
Pull
4
3
1
2
6
5
Recommended ≥ 7 Days
“Maintenance Recommended” Icon
Refer to this value and compare it with the table below.
Scan this QR code
Anti-slip strips
Date Sticker
(5 pieces; manually filled
with the start time of detection)
LCD After the First Power-On or Data Reset
Verification Code
Transparent
Screen-Icon Sticker
(Apply to the back only; avoid side air intake area)
User Manual
Radon Alarm
(Pre-installed removable AA battery × 3)
The device is self-testing.
LCD Displays Peak Level
Remove the insulating film.
1
background
09 10
823
4 5 6 7
Pull
4
3
1
2
6
5
Recommended ≥ 7 Days
“Maintenance Recommended” Icon
Refer to this value and compare it with the table below.
Scan this QR code
Anti-slip strips
Date Sticker
(5 pieces; manually filled
with the start time of detection)
LCD After the First Power-On or Data Reset
Verification Code
Transparent
Screen-Icon Sticker
(Apply to the back only; avoid side air intake area)
User Manual
Radon Alarm
(Pre-installed removable AA battery × 3)
The device is self-testing.
LCD Displays Peak Level
Remove the insulating film.
1
After the first power-on or data reset, both the long-term average and short-
term average will show “run”, indicating that the device is testing for the first
stable data. Based on the varying radon concentration in the environment, the
first data will be displayed within 4–24 hours.
NOTE: In most household environments, the first reliable reading comes in 24
hours. Please be patient. The higher the radon concentration, the shorter the
time for the first stable reading.
823
4 5 6 7
Pull
4
3
1
2
6
5
Recommended ≥ 7 Days
“Maintenance Recommended” Icon
Refer to this value and compare it with the table below.
Scan this QR code
Anti-slip strips
Date Sticker
(5 pieces; manually filled
with the start time of detection)
LCD After the First Power-On or Data Reset
Verification Code
Transparent
Screen-Icon Sticker
(Apply to the back only; avoid side air intake area)
User Manual
Radon Alarm
(Pre-installed removable AA battery × 3)
The device is self-testing.
LCD Displays Peak Level
Remove the insulating film.
1
Power Off: If the battery is removed or depleted, the device will automatically
power off. At this point, all records will be temporarily saved. When the device
is powered back on and completes the self-test, it will continue recording from
the last saved data.
All data in the device can only be cleared by holding down the “Reset Button”.
NOTE: It is not recommended to power off for more than 4 hours, as the detection
data may become distorted. In such cases, a retest is required.
3.2 Where to Place
1. It is recommended to conduct measurements in the basement or on the
lowest livable floor of the house, as radon primarily enters through these
areas. Since radon is much heavier than air, it tends to accumulate in lower
regions. However, you may also test any other frequently used area in the
house.
2. If an area is still under construction but is intended to be used later as a
workspace, game room, or additional bedroom, it is advisable to test in that
area as well.
3. Additionally, if the heating system is not operating during the test, the results
may be inaccurate. In such cases, it is recommended to perform the test while
the heating system is running.
NOTE: Normally, home radon detectors generally do not have strict placement
requirements. However, if you are concerned about placement or have specific
preferences, you can scan the QR code below the manual’s table of contents to
access the full digital manual and refer to “Appendix 1: Installation Location
Guidelines from AARST.”
Regardless of the choice, alarms shall be located no less than:
1. 3 feet (90 cm) from exterior doors, windows, or other potential openings to
the outdoors.
background
11 12
2. 20 inches (50 cm) above the floor.
3. 1 foot (30 cm) from the exterior wall of the building.
4. 1 foot (30 cm) below the ceiling.
5. 4 inches (10 cm) from other test alarms and objects or surfaces located above
or to the side of the alarm.
Another point to note is:
Improper location can affect the sensitive electronic components in this alarm.
To avoid causing damage to the device, to provide optimum performance, do
not locate the radon alarm in the following areas:
1. Inside closets, cabinets, sumps, crawl spaces, or nooks within the building
foundation.
2. Near heat sources, such as on appliances, radiators, fireplaces, or in direct sunlight.
3. Near drafts caused by fans or heating and air conditioning vents or in
enclosed areas of high air velocity, such as mechanical/furnace closets.
4. Within enclosed areas of high humidity exceeding 85%, such as bathrooms,
laundry rooms, and kitchens that are isolated from large open areas by
partitions or other enclosures.
5. Do not use outdoors.
NOTE: Avoid placing the radon alarm on or near objects that may produce
radiation, such as natural stone (e.g., rock collections, granite counter tops,
hearths, or slate pool tables).
Placement Instructions
The device is designed with anti-slip strips on the bottom, allowing it to be
placed on a flat surface for stable testing. During testing, do not block the air
intake area on the side of the device to ensure stable sampling.
823
4 5 6 7
Pull
4
3
1
2
6
5
Recommended ≥ 7 Days
“Maintenance Recommended” Icon
Refer to this value and compare it with the table below.
Scan this QR code
Anti-slip strips
Date Sticker
(5 pieces; manually filled
with the start time of detection)
LCD After the First Power-On or Data Reset
Verification Code
Transparent
Screen-Icon Sticker
(Apply to the back only; avoid side air intake area)
User Manual
Radon Alarm
(Pre-installed removable AA battery × 3)
The device is self-testing.
LCD Displays Peak Level
Remove the insulating film.
1
NOTE: Ensure that the device remains stationary throughout the entire testing period.
3.3 How to Conduct a Test
1. Monitoring starts automatically after the device is powered on. Please be
patient and wait for the first reading to appear (it will be available within 4–24
hours, typically around 24 hours).
NOTE: Normally, home radon detectors do not have strict pre-test preparation
requirements. However, if you are concerned, you can scan the QR code below
the table of contents to access the full digital manual and refer to “Appendix 2:
Pre-test Preparation Guidelines from AARST”.
2. Radon gas has unstable characteristics, so short-term data may not accurately
background
13 14
reflect the actual radon concentration in the house. It is recommended that
each monitoring cycle last at least 7 days, as the accuracy rises over time. If
the monitoring interval exceeds 1 year, covering the entire heating season,
rainy season, and so on, the monitoring data will be more precise, and you
can get accurate yearly radon average results.
NOTE: Don’t worry, the health threat posed by radon comes from long-term
(several years) exposure to high concentrations of radon. High concentrations of
radon do not pose an immediate health threat.
823
4 5 6 7
Pull
4
3
1
2
6
5
Recommended ≥ 7 Days
“Maintenance Recommended” Icon
Refer to this value and compare it with the table below.
Scan this QR code
Anti-slip strips
Date Sticker
(5 pieces; manually filled
with the start time of detection)
LCD After the First Power-On or Data Reset
Verification Code
Transparent
Screen-Icon Sticker
(Apply to the back only; avoid side air intake area)
User Manual
Radon Alarm
(Pre-installed removable AA battery × 3)
The device is self-testing.
LCD Displays Peak Level
Remove the insulating film.
1
NOTE: Normally, home radon detectors do not have strict testing procedures.
If you are concerned, you can scan the QR code below the table of contents
to access the full digital manual and refer to “Appendix 3: Testing Method
Guidelines from EPA”.
3.4 What the Test Result Means
823
4 5 6 7
Pull
4
3
1
2
6
5
Recommended ≥ 7 Days
“Maintenance Recommended” Icon
Refer to this value and compare it with the table below.
Scan this QR code
Anti-slip strips
Date Sticker
(5 pieces; manually filled
with the start time of detection)
LCD After the First Power-On or Data Reset
Verification Code
Transparent
Screen-Icon Sticker
(Apply to the back only; avoid side air intake area)
User Manual
Radon Alarm
(Pre-installed removable AA battery × 3)
The device is self-testing.
LCD Displays Peak Level
Remove the insulating film.
1
When the “Maintenance Recommended” icon ( ) appears and the LCD starts
flashing, it indicates that the radon concentration exceeds the threshold and
triggers the built-in alarm. You can take action yourself or consult local
professionals or authorities to learn about how to reduce the concentration in
your house.
NOTE: The flashing screen and the icon will automatically deactivate once radon
levels drop, requiring no manual intervention.
823
4 5 6 7
Pull
4
3
1
2
6
5
Recommended ≥ 7 Days
“Maintenance Recommended” Icon
Refer to this value and compare it with the table below.
Scan this QR code
Anti-slip strips
Date Sticker
(5 pieces; manually filled
with the start time of detection)
LCD After the First Power-On or Data Reset
Verification Code
Transparent
Screen-Icon Sticker
(Apply to the back only; avoid side air intake area)
User Manual
Radon Alarm
(Pre-installed removable AA battery × 3)
The device is self-testing.
LCD Displays Peak Level
Remove the insulating film.
1
However, due to varying testing habits, the device cannot cover all warning
scenarios. If the “Maintenance Recommended” icon ( ) does not appear but
background
15 16
you are still concerned, you can check the long-term average and refer to the
following table (the long-term average is meaningful only after at least 7-day
monitoring, and the accuracy rises over time):
Monitoring
Period
Concentration Recommended Actions
Long-Term
Average
≥4 pCi/L (150 Bq/m
3
) Maintenance required.
2-4 pCi/L (75-150 Bq/m
3
) Consider maintenance.
≤2 pCi/L (75 Bq/m
3
)
No obvious problems found. It
is recommended to continue
monitoring or change the monitoring
location. (When changing the
location, please use the “Reset Button”
to clear all data.)
NOTE: Any exposure to radon carries some level of risk. There is no completely
safe level of radon, and health risks still exist even when radon levels are below 4
pCi/L (150 Bq/m
3
).
4 Other Features
4.1 Device Battery Status and Battery Replacement
Device Battery Status
When the LCD displays the “Lo batt” message, the LED indicator flashes yellow once
every 60 seconds. Remove the old batteries and replace them with new ones.
823
4 5 6 7
Pull
4
3
1
2
6
5
Recommended ≥ 7 Days
“Maintenance Recommended” Icon
Refer to this value and compare it with the table below.
Scan this QR code
Anti-slip strips
Date Sticker
(5 pieces; manually filled
with the start time of detection)
LCD After the First Power-On or Data Reset
Verification Code
Transparent
Screen-Icon Sticker
(Apply to the back only; avoid side air intake area)
User Manual
Radon Alarm
(Pre-installed removable AA battery × 3)
The device is self-testing.
LCD Displays Peak Level
Remove the insulating film.
1
Even if the device has not yet reached the low battery alarm state, it is still
recommended to replace the batteries with fully charged ones before starting
a new testing cycle to prevent the device from shutting down due to battery
depletion during the testing. This is especially important during long-term tests,
as extended interruptions could lead to data distortion.
NOTES:
1. The device features a unique data continuity design. After a power outage
or shutdown, the data will not be automatically cleared. Once the device is
powered back on and restarted, it will continue recording from the previous
data. However, please ensure that the power-off duration does not exceed 4
hours to maintain data accuracy.
2. Rechargeable batteries are not allowed, as they may negatively impact
operation.
Battery Replacement
The device’s battery compartment is located at the bottom. Please flip the
device over and remove the battery cover (remember to read the precautions
on the inside of the battery cover). After replacing the batteries, the device can
be powered on and will perform a self-test.
background
17 18
823
4 5 6 7
Pull
4
3
1
2
6
5
Recommended ≥ 7 Days
“Maintenance Recommended” Icon
Refer to this value and compare it with the table below.
Scan this QR code
Anti-slip strips
Date Sticker
(5 pieces; manually filled
with the start time of detection)
LCD After the First Power-On or Data Reset
Verification Code
Transparent
Screen-Icon Sticker
(Apply to the back only; avoid side air intake area)
User Manual
Radon Alarm
(Pre-installed removable AA battery × 3)
The device is self-testing.
LCD Displays Peak Level
Remove the insulating film.
1
⚠
WARNING
1. KEEP NEW OR OLD USED BATTERIES OUT OF REACH OF CHILDREN.
2. In the event of a battery leaking, do not allow the liquid to come into contact
with the skin or eyes. If contact has been made, wash the affected area with
copious amounts of water and seek medical advice immediately.
3. Do not mix alkaline, standard (carbon-zinc), or rechargeable (Ni-Cd; Ni-MH)
batteries.
4. Different types of batteries or new and used old batteries are not to be mixed.
Do not mix batteries of different manufacturers, capacities, or sizes.
5. Batteries must be inserted with the correct polarity. Replacement of a battery
with an incorrect type can defeat the safeguard. There will be a risk of fire or
explosion if a battery is replaced with an incorrect type.
6. CONSTANT EXPOSURE TO HIGH OR LOW TEMPERATURES OR HIGH HUMIDITY
MAY REDUCE BATTERY LIFE.
7. Use only batteries specified in the marking. Use of a different battery may
have a detrimental effect on alarm operation.
4.2 Report Generation Feature
You can open the web interface by scanning the QR code at the bottom of the
device or manually entering the URL: https://radon.x-sense.com/report
On this interface, follow the instructions to manually enter the relevant
parameters and data, which will generate a PDF report that can be downloaded
to your phone or PC.
NOTES:
1. Please save the data report promptly at the end of each testing cycle.
2. Please ensure the accuracy of the input information, as incorrect data will
prevent the report from being generated.
823
4 5 6 7
Pull
4
3
1
2
6
5
Recommended ≥ 7 Days
“Maintenance Recommended” Icon
Refer to this value and compare it with the table below.
Scan this QR code
Anti-slip strips
Date Sticker
(5 pieces; manually filled
with the start time of detection)
LCD After the First Power-On or Data Reset
Verification Code
Transparent
Screen-Icon Sticker
(Apply to the back only; avoid side air intake area)
User Manual
Radon Alarm
(Pre-installed removable AA battery × 3)
The device is self-testing.
LCD Displays Peak Level
Remove the insulating film.
1
background
19 20
823
4 5 6 7
Pull
4
3
1
2
6
5
Recommended ≥ 7 Days
“Maintenance Recommended” Icon
Refer to this value and compare it with the table below.
Scan this QR code
Anti-slip strips
Date Sticker
(5 pieces; manually filled
with the start time of detection)
LCD After the First Power-On or Data Reset
Verification Code
Transparent
Screen-Icon Sticker
(Apply to the back only; avoid side air intake area)
User Manual
Radon Alarm
(Pre-installed removable AA battery × 3)
The device is self-testing.
LCD Displays Peak Level
Remove the insulating film.
1
NOTE: The report interface requires a 4-digit verification code. To obtain the
verification code, simultaneously press the Peak Level Button and the Backlight
Button.
5 Troubleshooting
No. LCD Indicator Problem
Possible
Causes
Solution
1 None.
The device
cannot be
powered on, and
the LCD shows
nothing.
The device isn’t
powering on
properly.
Open the battery
compartment
and remove the
battery insulating
film; if the
batteries run out,
please replace
them.
2
The LCD displays
“Lo batt,” and
the LED flashes
yellow once every
60 seconds.
The device has
entered the
low-battery
mode.
Replace the
batteries.
3
The LCD displays
“Err 01”, “Err 02”,
or “Err 03”, and
the LED flashes
yellow twice
every 60 seconds.
The device has
entered the
fault mode.
Restart the
device. If the
issue persists,
please replace
the device.
4
The LCD displays
“End” along with
a countdown in
days, and the LED
flashes yellow 3
times every 60
seconds.
The device
has started
a lifetime
countdown.
Promptly record
and save the
detection data
and replace the
device once it
reaches the end
of its service life.
5
The LCD displays
“End 00”, no
longer scrolls
data, and does
not respond to
any operations.
The device
has reached
the end of its
service life.
Replace the
device.
background
21 22
6
The LCD displays
“run” rather than
the specific data.
The device has
just powered
on and is
waiting to
output the first
stable data.
According to the
different radon
levels, the device
will output the
first stable data
within 4-24
hours. Please
wait patiently.
7 None.
The device has
not displayed the
“Maintenance
Recommended”
icon (
).
The radon
concentration
or testing
duration has
not yet reached
the threshold.
Continue to test.
Non-built-
in standard
warning
threshold.
Refer to “3.4
What the Test
Result Means”.
8 None.
The backlight
cannot be lit.
The device’s
battery is too
low.
Replace the
batteries.
The button is
not properly
pressed.
Ensure the
button has been
properly pressed.
9 None.
After replacing
the batteries, the
device retains the
previous data.
The data
retention
feature ensures
that removing
batteries will not
erase the data.
If you need to
erase the data,
please press the
Reset Button on
the device.
10
The short-term
average does not
fully display all
4 measurement
intervals.
The testing
duration
has not yet
reached the
required time
for the next
measurement
interval level.
Continue to test:
For example,
when the device
is first powered
on, only the “01D”
measurement
interval is
displayed. Once
the testing
time exceeds 7
days, both the
“01D” and “07D”
measurement
intervals will be
shown and scroll
on the display,
and so on.
background
23 24
6 Daily Maintenance
To keep your alarm in good working order, you should adhere to the
following steps:
1. Vacuum the alarm cover once every three months to remove any
accumulated dust.
2. Never use detergents or solvents to clean the alarm. Chemicals can
permanently damage or temporarily contaminate the sensor.
3. Avoid spraying air fresheners, hair spray, paint, or other aerosols near the
alarm.
4. Do not paint the unit. Paint may clog the openings to the sensing chamber
and prevent the unit from operating properly.
⚠
WARNING
1. DO NOT TAMPER WITH THE APPARATUS, AS THERE IS A RISK OF ELECTRIC
SHOCK OR MALFUNCTION.
2. USING THE DEVICE IN EXCESSIVELY HUMID ENVIRONMENTS MAY CAUSE
INTERNAL SENSOR CONTAMINATION, LEADING TO IRREVERSIBLE DAMAGE.
7 Statement
The Limitations of Radon Measurement
There is uncertainty in any measurement result due to statistical variations
and factors such as daily and seasonal changes in radon concentrations. These
variations may be caused by changes in the weather, the operation of the
dwelling, or possible interference with the required test conditions.
FCC Statement:
1. This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference
that may cause undesired operation.
2. Note: This equipment has been tested and found to comply with the limits
for a Class B digital device. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
background
25 26
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
3. Changes or modifications not expressly approved by the party responsible for
compliance could void your authority to operate the equipment.
4. The distance between user and products should be no less than 20 cm.
Environmental Protection
Waste electrical products should not be disposed of with household waste.
Please recycle where facilities exist. Check with the Local Authority or retailer for
recycling advice.
8 Manufacturer and Service Information
X-Sense Electronics Co., Ltd.
Address: Room 402, Building 4, No. 9, Jinshagang 1st Road, Shixia Village, Dalang
Town, Dongguan City, 523750 Guangdong, P.R. China
Email: support@x-sense. com
Website: www.x-sense.com
background
X-Sense Electronics Co., Ltd.
Email
:

Specifications

Indexed Terms: Radon Detector, Basement

X-Sense XR0A-SR Questions and Answers

Questions and Answers

Related Products

Product Kidde RAB image
Kidde RAB Radon Detector
2026-09-30 2 docs