DRAPER 03030 Spare A1P2 Filters (2) for Combined Vapour and Dust Respirator

Product's Documents

Below are documents related to this product, you can read online or download:
Other Documents Specification
03030 photo

Other

This is the main product document for model 03030.

The file format is pdf, 2 pages, you can download this manual here .

background
03030
EN
Original Instructions
Version 2
April 2025
REPLACEMENT DUST & VAPOUR
F I LT E R S
Stock No. 03030
Part No. 0503A1P2
Model Testing Centre and Certication Authority:
Institute of industrial safety of the German legal accident
insurrance (IFA)
Alte HeerstraBe 111
53757 Sankt Augustin
Germany
(Notied Body 0121)
1. Health and Safety Information
• IMPORTANT: Read this leaet in full before using this
product and retain it for future use. Always use the latest
version of the leaet. Please visit
drapertools.com/manuals for the latest version.
• The national regulations with regards to the use of the
lter must be followed exactly.
WARNING!
The lters must be used before the
expiration date marked on them (Year/Month
'YYYY/MM'). The lters help to protect against
certain airborne contaminants including toxic
dusts & bres as well as aqueous mists. For proper
use see instructions for both the lters and
respirator mask (03021). Improper use may cause
serious injury, harm to your health or death.
• Before use check the surroundings (type and
concentration of the dangerous materials) and that the
lters are suitable for the required application.
• NEVER use the lter under the following conditions:
In an oxygen enriched environment (oxygen
concentration >23.5%). Fires can start easily with
electrostatic sparks.
When the concentration of harmful gases exceeds 0.1%.
When there is a risk of explosion.
Close to sources of ames or liquid metal droplets
that may cause serious risk due to ignition of active
carbon in the lter generating high levels of toxic
substances.
In unventilated containers, pits, canals or narrow
rooms.
2. Markings on Filters
• The replacement lters supplied are type A1P2.
Filter
Type
Colour
Code
Application Max.
concentration
allowed
A1P2 Brown/
White
Class 1 – low capacity
for ltration of
organic gas/steam
vapour >65°. No
protection against
CO.
Dust and particles/
reuseable.
1.000ml/m3
(0.1 Vol.%)
or
30-times limit
value.
3. Usage Instructions
Suitable for use with Draper 03021 Vapour and Dust
Filter Respirator.
• Check the packaging and lter prior to use. DO NOT use if
there are any signs of damage such as holes or tears in the
packaging or the lters are deformed, cracked or show
signs of fatigue.
• Read both the lter and lter mask instruction leaets
carefully before tting the lters to the mask.
• Replace the lters as soon as increased breathing
resistance occurs.
• The lter is designed to protect against particles, ne
dust, water-based mists and liquid based aerosols. Check
the marking on the lter to ensure appropriate for your
application.
• Replace the lter away from the contaminated area.
• Important: Facial hair such as beards can prevent a tight
seal when mask tted.
EN
14387
A1
P2
background
Helpline: +44 (0) 23 8049 4344 Sales Desk: +44 (0) 23 8049 4333 General Enquiries: +44 (0) 23 8026 6355
Internet: drapertools.com Email: [email protected]
Draper Tools Limited, Hursley Road, Chandler’s Ford, Eastleigh, Hampshire. SO53 1YF UK.
Delta International, Delta International BV, Oude Graaf 8, 6002 NL, Weert, Netherlands. 0425
3.1 Storage & Cartridge Shelf Life
• After use remove the lters from the face piece and store
them separately.
• Store in a container away from the contaminated area
when not in use.
• The lters should always be tted or replaced in pairs and
the replacement lter should be of the same type and
class.
• Spent lters should be disposed of responsibly and in line
with local regulations. Recycle where possible.
• Always check the expiry date stated on the packaging and
lters (Year/Month = YYYY/MM) before using. DO NOT use
the lters after the expiry date or if the packaging is
damaged.
• Check the integrity of the respirator and replace the lters
as soon as the wearer begins to smell or taste the
contaminant or an irritation occurs. Store in a dry clean
area out of direct sunlight.
4. Symbols
Read the instruction manual
European conformity
UK Conformity Assessed
Maximum ambient humidity
for storage. Such as 80%
+35
-10
Storage temperature (ºC)
From -10ºC to 35ºC
Date at end of shelf life
"yyyy" as year
"mm" as month
At any time two lters only of the
same type and class must be used

Specifications

DRAPER 03030 Questions and Answers

See other models: 84120 84131 90064 07866 41918