Colderatti CLDRTI-PLNG-VSSL-PRO Vessel Pro Hot & Cold Plunge

Product's Documents

Below are documents related to this product, you can read online or download:
User Manual Specification
CLDRTI-PLNG-VSSL-PRO photo

Owner's Guide

This is the main product document for model CLDRTI-PLNG-VSSL-PRO. Additionally, the document applies to other Colderatti models: CLDRTI-PLNG-VSSL-PRO4W

The file format is pdf, 28 pages, you can download this manual here .

background
Vessel Pro
O w n e r s G u i d e
Installation · Operation · Care
background
• I n s t a l l a t i o n & S e t u p
• H o w T o D r a i n / F i l l
• P l u m b i n g & V a l v e s
• E l e c t r i c a l
• A p p C o n n e c t i o n
• C o n t r o l P a n e l
• W a t e r C a r e
• F i l t e r R e p l a c e m e n t
• R e m o t e - C h i l l e r S e t u p
• S a f e t y P r e c a u t i o n s
Contents
Click any item below to navigate directly to that section.
4
5
6
1 3
1 5
1 7
1 8
2 0
2 3
2 6
background
Product Dimensions
V e s s e l P r o O w n e r s G u i d e 3
background
Installation & Setup
Vessel Pro Owners Guide 4
Site requirements
Place the Vessel Pro and Hyperchiller on a solid, level, waterproof surface.
Maintain space surrounding the ice bath as detailed in the roughing-in image below.
The cord is 5 ft. long. If you plan to use an extension cord, use a 12-gauge.
Floor Drain
Electrical Outlet
Voltage
Amperage
GFCI Receptacle Recommended
120V
Dedicated 20A Circuit
3" Min
4" Min
24" Min
Fan exhaust clearance
Water Supply
Note: chiller can be placed remotely, up to 40 feet away from tub, and connected via 2 water lines. Choose
between Colderatti insulated water lines or dedicated plumbing lines (See ‘Remote-Chiller Setup’ for details).
Plumbing Requirements: The unit is designed for self-contained, freestanding operation with no permanent
plumbing required. Unit may be operated by draining/filling with a standard hose. Water supply and floor drain
are recommended for an integrated setup, but entirely optional.
background
5
Drain/Fill Without Plumbing:
To Fill:
Using a garden hose, fill the tub with water until the water level
reaches the middle of the skimmer.
*Plumbing is optional. For drain and fill plumbing
instructions, see the next page.
To Drain:
Attach a hose to the drain valve, then open the valve to drain.
If you have an automatic water pump:
• Connect a garden hose to the top port of the automatic water pump.
• Submerge the pump fully in plunge basin until it rests on the bottom.
• Route hose to drain location, plug in pump. Monitor water level.
Vessel Pro Owners Guide
background
34"
(864mm)
6
Drain/Fill With Plumbing:
*refer to next page for precise drain/fill valve locations
1. Drain valve: 1" NPT stainless steel thread. Connect to nearby floor drain.
2. Fill valve: 1" NPT stainless steel thread. Connect to water supply.
Vessel Pro Owners Guide
Floor Drain
Water Supply
Drain outlet.
Fill valve.
Indoor Installations Only: Install a vacuum breaker to the water supply pipe. Locate the vacuum
breaker 34″ (864 mm) from the floor to achieve a height of 6″ (152 mm) above the bath rim.
ASSE 1022
Vacuum Breaker
background
7
Vessel Pro Valve Specifications:
V e s s e l P r o O w n e r s G u i d e
background
A
B
C
D
C
B
I
N
L
E
T
O
U
T
L
E
T
A
Vessel Pro Owners Guide 8
Attach stainless steel shutoff valves to the 3 remaining ports.
Attach two-way valve to the 2 and 3 hydraulic connection ports.
nd rd
1. Connect valves and pre-filter:
• Twist water OUT and water IN valves to the ON position.
• Shut DRAIN and FILL all valves to the OFF position.
(ON position = straight, OFF position = sideways).
Attach pre-filter to the Hyperchiller INLET. Ensure the rubber o-ring
gasket is present before you screw it on.
Hyperchiller: backside
B
B
background
Connect one water line from the Hyperchiller OUTLET Water IN.
Connect second water line from the pre-filter on the INLET Water OUT.
D
9
2. Connect water lines:
Confirm pre-filter is attached to the Hyperchiller INLET.
Confirm the DRAIN and FILL shutoff valves are on the tub and
twisted to the OFF position.
A
B
C
D
Vessel Pro Owners Guide
Hyperchiller OUTLET
Hyperchiller INLET
Water IN
1" NPT
(Optional) The drain outlet can be
plumbed to a sanitary septic line
or routed to a nearby floor drain
for full water emptying. Uses a
twist ball valve for open/close.
(Optional) The fill valve can be
connected to a water source for easy
and controlled filling of the tub.
Water OUT
1" NPT
DRAIN
1" NPT
FILL
1" NPT
A
B
C
D
background
10
3. Fill with Water:
Fill the Vessel Pro until water is midway up the surface skimmer.
Vessel Pro Owners Guide
Minimum fill
background
*Failure to follow these precautions may damage the machine and void warranty.
4. Before turning on your cold plunge:
11
filter inside
hand-tightened
straight & secure
Water must be
above bottom valve
A
B
C
D
F
The water level must be above minimum fill, midway up the skimmer.
Verify the clear filter canister is securely hand-tightened to the chiller,
and the filter is inside, straight and securely seated.
Verify the Water IN, Water OUT, and any other shut-off ball valves are
straight, in the ON/OPEN position (next page).
Ensure the sediment pre-filter is securely connected (next page).
Ensure the two water lines are properly connected to the tub and
chiller, and in the correct orientation (page 9).
A
B
E
Ensure the rubber o-ring seals are in place inside the 2 water cables and
the pre-filter (next page).
Vessel Pro Owners Guide
Water must be
above minimum fill
background
C
D
12
C
D
E
V e s s e l P r o O w n e r s G u i d e
background
13
5. Plug In:
Before plugging in your Hyperchiller, make sure all items in Step 4:
Before turning on your cold plunge are fully completed and verified.
Plug your Hyperchiller into a standard 120V outlet. The outlet must
be on a dedicated 20A (minimum) circuit.
NEMA 5-20, (3-pronged
standard outlet)
120V, 20A
The machine includes built-in GFCI protection, so an additional external
GFCI is not necessary and may cause nuisance tripping.
Use only a 12-gauge extension cord if needed.
Vessel Pro Owners Guide
background
14
6. Set Temperature:
UP
DOWN
SET
POWER
Power on the Hyperchiller by pressing the POWER button.
Press and hold the UP & DOWN buttons at the same time to toggle
lock/unlock (a lock icon will show the lock status).
Allow system 1-2 hours to reach the target temperature.
Press the SET button (the temperature will start flashing on the control
panel) and use the UP/DOWN buttons to set temperature.
Vessel Pro Owners Guide
background
15
7. Pair your Hyperchiller with the app:
Download the Smart Life app.
Press and hold the UP & DOWN buttons at the same time to
toggle lock/unlock (a lock icon will show the lock status).
Hold the SET button for 7 seconds. Let go. You will hear a beep
and see the WiFi icon flash.
Press “Add Device” on the app, and the chiller will auto-connect.
App Store
Google Play
UP
DOWN
SET
POWER
Vessel Pro Owners Guide
background
16
Setup is complete!
V e s s e l P r o O w n e r s G u i d e
Continue reading for instructions for operation, water care, cleaning,
filter replacements, and remote chiller placement
background
17
Control panel
POWER
SET
DOWN
UP
• Press POWER button once to turn on. Press once to turn off.
• Press and hold SET button for 7 seconds then release to enter pairing for app connection.
• Press and hold UP and DOWN buttons to toggle lock/unlock. A lock icon will appear to show lock
status. When locked, you cannot change the temperature or power off.
• Press the UP and DOWN buttons to change temperature.
Vessel Pro Owners Guide
background
18
Water Care & Maintenance:
Everything you need for water care in one package:
6-month maintenance kit (Residential)
6-month maintenance kit (Commercial)
Hygiene Tip: A quick rinse/shower before use removes oils and impurities –
preserving water quality, extending time between water replacements, and
minimizing overall maintenance.
Initial Fill-Up
4oz Colderatti water clarifier
Daily Maintenance
1/2oz Colderatti water clarifier
Monthly Maintenance
(or as needed)
• Replace water with fresh water
• Replace the filter
• Rinse the pre-filter
Quarterly Deep Clean¹
Every 3 Months, deep clean
Initial Fill-Up
4oz Colderatti water clarifier
Daily Maintenance
1oz Colderatti water clarifier
Bi-Monthly Maintenance
(or as needed)
• Replace water with fresh water
• Replace the filter
• Rinse the pre-filter
Quarterly Deep Clean¹
Every 3 Months, deep clean
Residential Water Care
If your Vessel Pro lives at home,
follow these care instructions to
keep water clean, clear, and at
peak performance.
Commercial Water Care
While commercial settings require
more frequent care, you can
extend the interval between water
replacements to 4–8 weeks by
following our protocol and best
practices, and by integrating our
auto-sanitizer system. This ensures
maximum uptime for your facility.
Vessel Pro Owners Guide
¹Deep cleaning is recommended for optimal performance, cleanliness, and
longevity of the machine. Instructions on next page.
background
19
Deep clean your plunge
We recommend deep cleaning your plunge every 3 months, for optimal
performance and longevity of the machine.
1. Drain all water and refill with clean water to 1/3 capacity.
2. Add 4oz (1/2 cup) food-grade citric acid*
3. Turn the Hyperchiller on and set the temp 75ºF.
4. Let the water cycle for 15 minutes with the citric acid solution.
5. Turn the Hyperchiller off and drain the tub fully.
6. Rinse the inside basin with warm water and a clean microfiber.
7. Run a final flush: fill with clean water to 1/3 capacity and turn the
Hyperchiller on for 5 minutes. Then turn off and drain water fully.
8. Replace the filter with a new filter. Deep clean is finished.
*Citric acid is a natural descaler that breaks down mineral deposits, biofilm,
and tarnish from the inside surface of the system—ideal for naturally flushing
your system and restoring it to a like-new condition, while leaving the stainless
steel more corrosion-resistant and with a visibly cleaner and brighter finish.
Cleaning requirements
Follow these best practices for regular cleaning and care to keep your Colderatti
stainless steel system in peak condition.
Water care: use Colderatti water clarifier regularly and replace filters as required
to keep water clean, clear, and free of oils and debris.
Stainless steel:
Clean stainless steel surfaces with a soft cloth and mild degreaser (dish
soap).
For tough mineral spots or stains, wipe stainless steel with warm water and
food-grade citric acid, then rinse.
Always rinse and dry surfaces after cleaning.
Use only soft microfiber cloths—never abrasive scrubbers.
DO NOT mix citric acid or hydrogen peroxide with other cleaning chemicals.
Vessel Pro Owners Guide
background
20
Replacing the filter
Replace the filter once per month for optimal performance and
longevity of the machine.
• Unscrew the clear filter canister.
• Remove the old filter, empty the water from the canister, replace with new
filter. Screw in.
• The pre-filter (smaller filter located on the chiller INLET) must also be rinsed
out with water and a small brush or toothbrush.
1
2
3
4
5
remove old filter
insert new filter
Vessel Pro Owners Guide
background
21
Water Testing
If you choose to test your water using water test strips, expect each
parameter to fall within the ideal ranges below:
1. Free Chlorine or Bromine: 0ppm
2. pH: 7.2–7.8
3. Total Alkalinity: 80–120 ppm
4. Calcium Hardness: 150–250 ppm
5. Total Dissolved Solids (TDS): under 1,500 ppm
6. Cyanuric Acid: 0 ppm
7. Oxidation-Reduction Potential (ORP): 500–750 mV
Note: The parameters above are specifically for oxygen-based, chemical-free
sanitation. If you utilize chlorine-based sanitation, these values will differ – most
notably, Free Chlorine should typically be maintained between 1–2 ppm.
Expected Results After 2 Weeks of Daily Use:
With proper daily water care, pH, Alkalinity, Hardness, and TDS levels typically fall
within 90–95% of ideal ranges. Results may vary based on user hygiene, adherence
to water care routines, and the quality of your initial water source.
Vessel Pro Owners Guide
background
22
Remote-Chiller Setup Requirements:
1. Distance Requirements:
Max vertical lift: 15 ft
Max run length (vertical + horizontal): 40 ft
Make sure the chiller is placed within these limits.
3. Ventilation Requirements:
Chiller must have minimum 24" clearance on fan end.
If chiller is placed in enclosed area, it must have (either):
2 passive vents (one vent next to Hyperchiller fan out, one vent
opposite, allowing adequate passive airflow) OR
Inline duct fan (900 CFM+) high, and passive vent low, near chiller.
An open area with adequate air circulation is ideal for chiller installation. A
large, climate-controlled space with HVAC airflow typically requires no
additional ventilation or fan system, provided the room has a minimum
airflow capacity of 900 CFM. Avoid installing the chiller in small, enclosed
spaces without sufficient air exchange, as heat buildup can reduce
performance and efficiency.
The below requirements are to be used for general information and planning
purposes. Any installations with water lines longer than the standard (6ft) require
an engineered solution. Please consult with a licensed pool and spa professional,
and approve all remote-chiller designs with a Colderatti engineer before installing.
Vessel Pro Owners Guide
2. Plumbing Requirements:
All plumbed water lines must be 1" diameter minimum and insulated
with a 1/2" thick HVAC-grade pipe insulation.
Each line must terminate with a 1/2" male threaded NPT connection at
both end points.
All directional changes must use long-radius sweep 90° fittings to
minimize flow restriction. Avoid sharp 90° elbows.
For remote chiller installations with water lines longer than 6 ft, an
inline water supply is required to prime the INLET line and remove
trapped air from the system.
background
23
Remote-Chiller Setup:
Vessel Pro Owners Guide
1. Connect Water Lines (IN/OUT):
If connecting through wall ports, label wall lines as IN/OUT clearly to
avoid confusion or mismatching the water lines.
Hyperchiller INLET
→
connects to pump suction port on the tub
Hyperchiller OUTLET
→
connects to water return port on the tub
3. Prime the INLET Line:
Open the valve to allow the prime water source to fill the water lines.
The priming process typically takes 10–15 seconds. Once primed, the
filter chamber will fill with water, indicating that the air is removed and
the lines are fully primed.
2. Final Checks Before Powering On:
Review STEP 4 (Page 11) for full checklist.
The below setup instructions are to be used for general information and planning
purposes. Any installations with water lines longer than the standard (6ft) require
an engineered solution. Please consult with a licensed pool and spa professional,
and approve all remote-chiller designs with a Colderatti engineer before installing.
4. Power on the chiller:
Once the water lines are primed and the filter chamber is filled with
water, power on the chiller by pressing the power button.
As soon as the chiller pump establishes water circulation (the flowrate
on screen should be reading 25-30L/min), immediately turn off the
prime water supply.
background
Side View
24
Remote-Chiller Setup Drawings
Vessel Pro tub
Hyperchiller
Top View
15ft max vertical lift
A <= 15
40ft max run length
A+B+C <= 40
A
B
C
A
Vessel Pro Owners Guide
The chiller should always be
placed at or below the level of
the tub and never above.
background
25
Remote-Chiller Installation Examples
Vessel Pro Owners Guide
Installation Guidelines:
15ft max vertical lift
40ft max total run length
Chiller below water level
Water lines always below water level
Do not install a plumbing path which
rises above water level.
Do not place the chiller above ground
level.
background
26
Safety Precautions:
No children or pets – never allow unsupervised access. Secure the cover when not
in use.
No alcohol or drugs – these can drastically increase the risk of unconsciousness,
drowning, or hypothermia.
Know your limits – sudden cold immersion can trigger cold shock or hypothermia.
Always use under supervision until you know your body’s response.
Electrical safety – only use a dedicated 20A, 120V circuit with GFCI protection;
keep all outlets and devices 5 feet away.
Do not modify electrical components – only qualified technicians should access
internal electronics. Tampering can lead to electric shock, fire, or system failure.
Consult Your Doctor – especially if pregnant, have heart conditions, blood
pressure issues, diabetes, or are taking medication that may cause drowsiness.
Use with supervision if needed – those with reduced physical, sensory, or mental
ability should only use the plunge under supervision.
Freezing Conditions – Operating or storing this equipment in temperatures below
32°F (0°C) strictly voids the warranty. While the Hyperchiller is equipped with
internal freeze protection as a safety measure; it is not rated for operation or
storage in freezing environments. The system must remain powered on at all times
to utilize its internal safety sensors; if the unit loses power or is turned off in cold
conditions, it must be completely drained of water and moved indoors
immediately. Any damage resulting from freezing temperatures – including
damage resulting from power failure or outdoor placement – is at the user’s own
risk and is strictly excluded from warranty coverage.
Vessel Pro Owners Guide
Install Properly – the standard package is designed for self-installation in outdoor
locations or large, open indoor spaces with adequate airflow and HVAC. The
standard configuration includes 6ft water lines connecting the tub directly to the
chiller. Any installations that differ from this standard configuration – including
water line runs longer than 6ft, or installation in enclosed spaces with limited airflow
– requires additional planning and an engineered solution. Consult with a qualified
pool and spa professional and obtain approval from Colderatti before proceeding
with custom or non-standard installation designs.
background
Error Code
Reason
Solution
CLN
Low Flow Rate
Clean or replace the filter
FL
Flow Issue
Possible solutions:
• Confirm both water valves are in the ON position (straight).
• Confirm seal rings are on the inside of the water hoses.
• Reset the Hyperchiller. Power it off and on.
Issue
Solution
Water leaking at a
connection point
• Verify water lines are firmly hand-tightened (only hand-
tightening required)
• Verify the O-rings within the water lines are intact and
properly seated inside the metal connection fittings.
• Teflon is not required on connection points with Colderatti
insulated water lines due to the included o-rings. Any other
connections (such as the tub hydraulic connections to the
manifold) must have 7-10 wraps of teflon around each thread.
Water dripping from
chiller
In humid environments, or if the chiller is heating the water,
condensation can cause water to drip from the chiller
condensation line. Place a drip pan underneath the chiller to
catch condensation drips if needed.
Service & Troubleshooting:
27V e s s e l P r o O w n e r s G u i d e
background

Specifications

Colderatti CLDRTI-PLNG-VSSL-PRO Questions and Answers

Questions and Answers

Related Products