READ AND SAVE THESE INSTRUCTIONS
CEILING FAN INSTALLATION MANUAL
background
background
WARNING: To reduce the risk of personal injury,
do not bend the blade brackets (also referred to as
flanges) during assembly or after installation. Do not
insert objects in the path of the blades.
WARNING: To reduce the risk or fire or electric
shock, do not use this fan with any solid-state
speed control device.
WARNING: To avoid possible electric shock,
turn the electricity off at the main fuse box before
wiring. If you feel you do not have enough electrical
wiring knowledge or experience, contact a licensed
electrician.
WARNING: Electrical diagrams are for reference
only. Optional use of any light kit shall be UL-listed
and marked suitable for use with this fan.
WARNING: To reduce the risk or fire, electric shock,
or personal injury, mount to outlet box marked”
Acceptable for fan support of 35 lbs.(15.9 kg) or
less“ and use the screws provided with the outlet
box.
WARNING: Remove the rubber motor stops on
the bottom of the fan before installing the blades
or testing the motor.
Safety Information
To reduce the risk of electric shock, the electricity
has been turned off at the circuit breaker or fuse
box before begin.
All wiring must be in accordance with the National Electrical
Code NASI/NFPA 70-1999 and local electrical codes.
Electrical installation should be performed by a qualified
licensed electriccian.
The outlet box and support structure must be securely
mounted and capable of reliably supporting
35lbs(15.9kg). Use only UL listed outlet boxes marked
“Acceptable for Fan Support of 35lbs(15.9kg) or less.”
The fan must be mounted with a minimum of 7 ft. (2.1m)
clearance from the trailing edge of the blades to the floor.
Do not operate the reversing switch while the fan blades
are in motion. You must turn the fan off and stop the
blades before you reverse the blade direction.
Do not place objects in the path of the blades.
To avoid personal injury or damage to the fan and
other items, please be careful when working around
or cleaning the fan.
Electrical diagrams are for reference only. Light kits that
are not packed with the fan must be UL-listed and marked
suitable for use with the model fan you are installing.
Switches must be UL General Use Switches. Refer to the
instructions packaged with the light kits and switches for
proper assembly.
After making electrical connections, spliced conductors
should be turned upward and pushed carefully up into
the outlet box. The wires should be spread apart with the
grounded conductor and the equipment-grounding
conductor on one side of the outlet box.
All set screws must be checked and retightened where
necessary before installation.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
Installation & Operating Instructions for the
Parrotuncle Owner's Installation, Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BERAKER
F8004ABK-NL
background
Thank you for purchasing this quality product. To ensure correct function and safety, please read and save all instructions before using the
product.
1. To avoid possible electric shock, turn off the electricity at the main fuse box or circuit panel before you begin the fan installation or before servicing the fan or
installing accessories.
2. Read all instructions and safety information carefully before installing your fan and save these instructions.
3. Make sure all electrical connections comply with local codes or ordinances and the National Electrical Code. If you are unfamiliar with electric wiring, please
use a qualified and licensed electrician.
4. Make sure you have a location selected for your fan that allow clear space for the blades to rotate, and at least seven(7) feet of clearance between the floor and
the fan blade tips. The fan should be mounted at least thirty (30) inches from walls or other up right structures.
5.WARNING: The outlet box and ceiling support joist used must be securely mounted, and capable of supporting at least 100 pounds. To reduce the risk of fire,
electric shock or personal injury, mount to the outlet box marked acceptable for fan supported and use mounting screws provided with the outlet box. The box must
be supported directly by the building structure.
6. WARNING: To reduce the risk of fire, electric shock or personal injuy, mount to outlet box marked "acceptable for fan support" and use mounting screws
provided with the outlet box most outlet boxes commonly used for the support of lighting fixtures are not acceptable for fan support and may need to be replaced.
Consulta qualified electrician if in doubt.
7. Electrical diagrams are for reference only. Light kits that are not packed with the fan must UL listed and marked suitable for use with the model fan you are
installing. Switches must be UL. general use switches. Refer to the instructions packaged with the light kits and switches for proper assembly.
8. After installation is complete, check that all connections are absolutely secure.
9. After making electrical connections, spliced conductors should be turned upward and pushed carefully up into outlet box. The wires should be spread apart with
the grounded conductor and the equipment-grounding conductor on one side of the outlet box.
10. WARNING: To reduce the risk of electrical shock and fire, do not use this fan with any solid-state fan speed control device, or rheostat.
11. Do not separate the reverse switch until the fan has come to a complete stop.
12. Do not insert anything into the fan blades while they are rotating.
13. WARNING: To reduce the risk of personal injury, do not bend the blade brackets (also referred to as "flanges") during assembly or after installation.
Do not insert objects in the path of the blades.
14. To avoid personal injury or damage to the fan and other items, be cautious when working around or cleaning the fan.
15. Do not use water or detergent when cleaning the fan or fan bades. A dry dust cloth or lightly dampened cloth will be suitable for most cleaning.
NOTE: The important safety precautions and instructions appearing in the manual are not meant to cover all possible conditions and situations that may occur.
It must be understand that common sense and caution are necessary factors in the installation and operation and operation of this fan.
NOTE: This productis not intended for use by persons (including children) with reduced physical, sensory or mental capabilities are different or are impaired, or
lack of experience or knowledge, unless such persons are supervised or trained to operate the appliance by a person responsible for their safety.
NOTE: Children should be supervised to ensure that they do not use appliances as a toy.
SAFETY TIP
TECHNICAL INFORMATION
SKU# Rated Voltage
F8004ABK-NL
110-120 VAC
Rated Power (motor) Light
THANK YOU FOR YOUR PURCHASE
58W NON
Installation & Operating Instructions for the
Parrotuncle Owner's Installation, Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BERAKER
F8004ABK-NL
background
Wood screws
(4PCS)
Mounting screws
(2PCS)
Washer (2PCS)
Spring washer
(2PCS)
Screw
(1PC)
PIs check whether above accessories are completed or not? Yes, and install.
Remote control (1 set)
Installation & Operating Instructions for the
Parrotuncle Owner's Installation, Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BERAKER
F8004ABK-NL
Slide-on mounting bracket
10" Ball/downrod assembly
Canopy
Canopy cover
Coupling cover
"R" Locking pin
Fan body
Bottom cap
Blade (6PCS)
Hanging pin
Top housing
Blade bracket (6PCS)
Blade screw
(19PCS)
Washer (19PCS)
Hex nut (19PCS)
Wrench(1PC)
18” Extension cord (1PC)
24” Extension cord (2PC)
REV
ON/OFF
1H/2H/4H/8H
+
-
1 2 4 8
background
Installation & Operating Instructions for the
Parrotuncle Owner's Installation, Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BERAKER
F8004ABK-NL
3
Attach the fan blade to the blade bracket using 3 blade screws, 3 hex nuts and 3 washers provided, tighten them firmly using wrench.
Complete 6 blades assemblies.
1
Loose 2 screws of the mounting bracket under the canopy, removed the
mounting bracket from the canopy.
WARNING:
To avoid possible electrical shock, before installing your ceiling fan, disconnect the power by turning off the circuit
breakers to the outlet box associated with the wall switch location.
Option 1: Concrete ceiling
Use 2 mounting screws and washers provided when:
Securing to existing ceiling fan-rated outlet box.
Make sure it is securely installed and is acceptable
for fan support of 15.9kg (35 lbs) or less.
Option 2: Wood ceiling
Use 4 wood screws when:
Securing to support structure with apporved electrical
outlet box. Drill 4 holes in support structure to aid in
securing ceiling bracket.
Wood
Screws
background
Installation & Operating Instructions for the
Parrotuncle Owner's Installation, Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BERAKER
F8004ABK-NL
4
6
8 9
Remove the pre-installed setscrews and downrod pin.
7
Remove 6 screws and top housing surport from fan body, attach the top housing
to the fan body using removed screws and top housing surport
Remove 18 screws from the ceiling fan body, place the screws
for subsequent.
5
Slide a blade assembly through one of the narrow of the fan body, and use the
3 screws removed to lock it onto the fan body and tighten them.
Install 6 blade assemblies.
Loosen and remove the two screws on the downrod ball
from the downrod. Lift the downrod upwards then remove
the horizontal bar.
Insert the canopy, canopy cover and the coupling cover to the downrod.
Pass all the wires and safety rope to the downrod.
background
Installation & Operating Instructions for the
Parrotuncle Owner's Installation, Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BERAKER
F8004ABK-NL
12
10 11
14
Place the downrod ball into the ceiling bracket. Make sure the downrod
ball slot matches the inner lock. Rotate the downrod until it secured.
13
Install the safety rope.
Re-install the downrod ball onto the downrod, insert the horizontal
bar in its designated position. Tighten 2 removed screws from
the downrod ball.
Carefully screw the downrod into the yoke of the fan body. Carefully
re-install the downrod pin and clip. Tighten 2 removed setscrews. Put down
the coupling cover.
Safety rope
a. Connect the wires (white to white, black to
black) from the ceiling to the controller using
wire nuts.
b. Connect the 4 grounding wires (green wires)
coming from the ceiling, downrod, controller and
ceiling bracket using a wire nut.
c. Insert the motor wires from the fan body to the
motor wire of the controller.
d. Slide the controller between the mounting
bracket and the top of the downrod.
Note: Use the canopy to place the
exceeded wires.
WIRING MUST BE UP TO CODE. All wiring
must be in accordance with national and
local electrical codes. If you are unfamiliar
with wiring or in doubt, consult a
qualified electrician.
Motor wire
background
15
16
Screw the bottom cap to the fan body and tighten firmly.
Installation & Operating Instructions for the
Parrotuncle Owner's Installation, Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BERAKER
F8004ABK-NL
Install the canopy to the screws of the ceiling bracket, tighten the screws and cover the canopy cover.
background
PRODUCT SIZE
Installation & Operating Instructions for the
Parrotuncle Owner's Installation, Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BERAKER
F8004ABK-NL
120 in. (3020mm)
Dia 15.9 in.(Ø150mm)
Dia 9.9 in.(Ø252mm)
17.4 in. (442mm)
background
Installation & Operating Instructions for the
Parrotuncle Owner's Installation, Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BERAKER
F8004ABK-NL
REMOTE CONTROL MATCHING CODE:
Within 5 seconds after power on, hold press the the key, when hear the buzzing sound, the code match is
successful. If not, please repeat the above steps again.
●
RF wireless digital transmission technology is adopted to realize the one-to-one control providing a rate of
coincident code less than 1/50000. Same code number is attached to the back of the emitter and the receiver.
It is required to return a pair of the same code number of emitter / receiver to the manufacturer for repair service in
case of any damage.
In a sufficient space, you can use the receiver at any angle, no worry about the direction.
●
- Press key, fan speed 1 to 6 levels
- Press key, fan speed 6 to 1 level
Timer Settings
Control buttons
Power Switch
Press to turn the power ON/OFF
Within 5 seconds after power on,
hold press 3 seconds to match code.
Forward and Reverse
Press to change the airflow
direction.
Within 5 seconds after power on,
hold press 3 seconds to clear code.
- Press once time, fan auto off after 1hr
- Press twice time, fan auto off after 2hr
- Press 3 times, fan auto off after 4hr
- Press 4 times, fan auto off after 8hr
- Press 5 times, cancel timer
Fan Speed Setting
Natural Wind Mode
- Fan speed cycle from 1-2-3-4-3-2-1
LED Indicator
Timer setting Indicator
Speed setting Indicator
Child lock settingSwitch
- Hold press 3 seconds to open/close,The
indicator light flashes twice.
- When the child lock is closed, only this button
can work.
REV
ON/OFF
1H/2H/4H/8H
+
-
1 2 4 8
Sleep Wind Mode
- Fan speed cycle from 1-2-1
background
Installation & Operating Instructions for the
Parrotuncle Owner's Installation, Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BERAKER
F8004ABK-NL
INSTALL THE REMOTE CONTROL HOLDER
Use the two holes on the holder as a guide to drill two
corresponding holes in the flat wall.
Insert two expansion screws into the holes and
make them level with the flat wall.
Align the two holes on the holder with the two holes
on the wall. Insert the two screws into the holes and
tighten them using a screwdriver.
NOTE: Install a CR2032, 3 volt lithium battery
(Included). Open battery cover to remove
insulation spacer before use remote control.
REPLACE THE BATTERIES
Remove the screw from the battery cover on the
remote control using a Phillips head screwdriver.
Pull up and remove battery cover.
Remove the old battery and replace a new
CR2032, 3V battery. Install the battery cover
removed earlier with the screw removed.
WARNING
TO REDUCE THE RISK OF SHOCK.THIS FAN MUST BE INSTALLED WITH A WALL CONTROL/SWITCH.
Battery cover
Insulation spacer
Screw
CR2032
3V lithium battery
Store your remote control.
REV
ON/OFF ON/OFF
1H/2H/4H/8H
K
+
-
1 2 4 8
background
Installation & Operating Instructions for the
Parrotuncle Owner's Installation, Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BERAKER
F8004ABK-NL
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference.
(2) this device must accept any interference received, including interference that may cause undesired
operation.
Please note that changes or modifications of this product is not expressly approved by the party responsible
for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been
tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception which can be determined
by turning the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
FCC STATEMENT
WARNING INGESTION HAZARD:
This product contains a button cell or coin battery.
Remove and immediately recycle or dispose of used batteries according to local regulations and keep away
from children. Do NOT dispose of batteries in household trash or incinerate.
Even used batteries may cause severe injury or death.
Call a local poison control center for treatment information.
Compatible battery type is CR2032, 3V.
Ensure the batteries are installed correctly with regard to polarity (+ and -).
Do not mix old and new batteries, different brands or types of batteries, such as alkaline, carbon-zinc,
or rechargeable batteries.
Non-rechargeable batteries are not to be recharged. Exhausted batteries are to be removed from the
product.
Do not force discharge, recharge, disassemble, heat above (manufacturer's specified temperature rating)
or incinerate.
Doing so may result in injury due to venting, leakage or explosion resulting in chemical burns.
Remove and immediately recycle or dispose of batteries from equipment not used for an extended period
of time according to local regulations.
Always completely secure the battery compartment. If the battery compartment does not close securely,
stop using the product, remove the batteries, and keep them away from children.
WARNING
INGESTION HAZARD:
This product contains a
button cell or coin battery.
DEATH
or serious injury can occur if ingested.
A swallowed button cell or coin battery can cause
Internal Chemical Burns
in as little as 2 hours.
KEEP
new and used batteries
OUT OF BEACH OF CHILDREN
Seek immediate medical attention
if a
battery is suspected to be swallowed or inserted
inside any part of the body.
background
Installation & Operating Instructions for the
Parrotuncle Owner's Installation, Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BERAKER
F8004ABK-NL
TROUBLESHOOTING GUIDE
Table of Contents
1. Fan / Remote is not working
2. Fan is noisy
3. Fan Wobbles
4. Light is not working
Please refer to the instruction sheet for detailed directions and descriptions of
installation steps and requirements
1. FAN / REMOTE IS NOT WORKING
Ensure the remote is within the 20 feet range of the receiver
To reset the remote control: 1) Turn off power to fan using the wall switch or circuit breaker. 2) Remove ba�eries from remote.
3) Wait 10 seconds. 4) Replace ba�eries and turn power on
Check ba�eries to insure they are good and oriented correctly
Check to make sure the frequency switches (DIP Switches) from the remote to the receiver are set to the same frequency
Check the main and branch circuit fuses or breakers
If using a Variable Speed Wall Switch, ensure it is specifically designed for use with a ceiling fan.
Check the line wire connec�ons to the fan and the switch wire connec�ons in the switch housing per the instruc�ons
If fan s�ll does not work, please contact Customer Service [email protected]
Make sure all motor housing screws are �ghtened
Make sure the screws that a�ach fan blade to motor are �ght
Make sure the wire nut connectors are not ra�ling against each other or the interior wall of the switch housing
Allow 24-hour break in period. Most noises associated with the new fan may disappear during this �me
If using a ceiling light kit, make sure the glassware is secured �ghtly
Make sure there is a short distance/gap from the ceiling to the top of the canopy. The canopy should not touch the ceiling!
Make sure your ceiling box is secure and that the rubber isolator pads are used between the moun�ng bracket and outlet box
2. THE FAN IS NOISY
Verify all blades and blade bracket screws are secure (most fan wobble problems are caused by loose parts). Once fan is properly
installed, run the ceiling fan for 10 minutes to let the fan self-adjust.
If wobble occurs a�er running the fan for 10 minutes, verify blade level using the following process:
a) select a point on the ceiling above the �p of one of the blades. Then select the fan blade and measure from the center
of the selected blade to point on the ceiling. Rotate the fan un�l the next blade is posi�oned and repeat the
measurement using the same point from the ceiling for every blade. Measurements should be within 1/8 inch.
3. THE FAN WOBBLES
b) If all devia�on are less than 1/8 inch and the fan con�nues to wobble, please contact Customer Service Support@parr
otuncle.com to order a complimentary Blade Balancing Kit
- If all devia�ons are less than 1/8 inch and the fan con�nues to wobble, please contact Customer Service Support@parrotuncle
.com to order a complimentary Blade Balancing Kit
4. LIGHT IS NOT WORKING
Check Bulb to make sure it is installed correctly
Remove non-working bulb and replace with a bulb that is known to be a good working bulb
To reset the remote control: 1) Turn off power to fan using the wall switch or circuit breaker. 2) Remove ba�eries from
remote. 3) Wait 10 seconds. 4) Replace ba�eries and turn power on
background
Installation & Operating Instructions for the
Parrotuncle Owner's Installation, Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BERAKER
F8004ABK-NL
The fan blades have been adjusted in the factory to minimize any wobble
AFTER INSTALLATION
WOBBLE
NOTE: CEILING FANS TEND TO MOVE DURING OPERATION DUE TO THE FACT THAT THEY ARE MOUNTED ON A RUBBER
CROMMET. IF THE FAN WAS MOUNTED RIGIDLY TO THE CEILING, IT WOULD CAUSE EXCESS VIBRATION. MOVEMENT OF
A FEW CENTIMENTERS IS QUITE ACCEPTABLE AND DOES NOT SUGGEST ANY PROBLEM
TO REDUCE THE FAN WOBBLE, PLEASE CHECK THAT ALL SCREWS WHICH SECURED THE MOUNTING BRACKET AND
DOWNROD ARE SECURE.
BALANCING A WOBBLING CEILING FAN
1. Check that all blade and blade arm screws are secure.
2. Most fan wobbling problems are caused when blade levels are unequal.
Check this level by selec�ng a point on the ceiling above the �p of one of
the blades. Measure this distance. Rotate the fan un�l the next blade is
posi�oned for measurement. Repeat for each blade. The distance devia�on
should be equal within 1/8"(0.32cm).
3. If the blade wobble is s�ll no�ceable, interchanging two adjacent (side by
side) blades can redistribute the weight and possibly result in smoother opera�on.
WARNING: TO REDUCE THE RISK OF PERSONAL INJURY, DO NOT BEND THE BLADE ARM WHILE INSTALLING, BALANCING
THE BLADES, OR CLEANING THE FAN. DO NOT INSERT FOREIGN OBJECTS BETWEEN ROTATING FAN BLADES.
NOISE
When it is quiet (especially at night) you may hear occasional small noises. This is normal. Please allowa 24-hour “breaking-in”
period, most noises associated with a new fan disappear during the �me.
CARE AND CLEANING
1. Periodic cleaning of your ceiling fan is the only maintenance required. Use a so� brush or lint free cloth to avoid scratching
the paint finish. Please make sure to turn off electricity power before you clean your fan.
2. Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an
electrical shock.
3. Motor has permanently lubricated ball bearing. No need to oil.
NOTE:
MAKE SURE THE POWER IS OFF AT THE ELECTRICAL PANEL BOX BEFORE YOU ATTEMPT
ANY CLEANING OR REPAIRS.
Tauching
ceiling
background

Specifications

Indexed Terms: Ceiling Fan, HVLS, HVLS Fan