ElectriQ CD12LE-V3 Premium 12L Low-Energy Quiet Laundry Dehumidifier

Product's Documents

Below are documents related to this product, you can read online or download:
CD12LE-V3 photo

User Manual

This is the main product document for model CD12LE-V3.

The file format is pdf, 20 pages, you can download this manual here .

background
USER MANUAL
PREMIUM LOW-ENERGY DEHUMIDIFIER
With Digital Humidistat
CD12LE 12Litres per day
CD20LE 20Litres per day
background
2
background
3
CONTENTS
SAFETY INSTRUCTIONS
VISUAL SAFETY GUIDE
INFORMATION ON INDOOR POLLUTANTS
APPLIANCE DIAGRAM
FEATURES
FITTING THE OPTIONAL FILTERS
CONTROL PANEL
4
6
6
7
8
8
9
OTHER FEATURES AND INDICATORS
QUICK REFERENCE GUIDE
POSITIONING THE DEHUMIDIFIER
WATER DRAINAGE
11
12
13
14
CARE AND MAINTENANCE
END-OF-SEASON MAINTENANCE
TROUBLESHOOTING
TECHNICAL DATA
SUPPORT
15
15
16
17
18
background
4
SAFETY INSTRUCTIONS
IMPORTANT
Carefully read the instrucons before
operang the unit.
This appliance is only intended for use in
an indoor domesc environment. The
manufacturer does not recommend any
other use and may cause re, electrical
shock or other injuries to a person or
damage to property.
Rang: This unit must only be connected to
an AC 220-240V / 50 Hz earthed outlet.
Installaon must be in accordance with the
regulaons of the country where the unit is
used.
If you are in any doubt about the suitability
of your electrical supply, have it checked
and, if necessary, modied by a qualied
electrician.
This dehumidier has been tested and is
safe to use. However, as with any electrical
appliance – care must be taken during use.
CAUTION: In order to avoid a hazard due to
inadvertent reseng of the thermal cut-
out, this appliance must not be supplied
through an external switching device, such
as a mer, or connected to a circuit that is
regularly switched on and o by the ulity.
Disconnect the power from the appliance
before dismantling, assembling or cleaning.
Avoid touching any moving parts of the
appliance.
Never insert ngers, pencils or any other
objects through the guard.
This appliance is not intended for use by
persons (including children) with reduced
physical, sensory or mental capabilies. It
is also not intended for use by those with a
lack of experience and knowledge unless
they have been given supervision or
instrucon concerning the use of the
appliance by a person responsible for their
safety.
Children should be supervised to ensure
they do not play with the appliance.
Do not clean the unit by spraying it or
immersing it in water.
Never connect the unit to an electrical
outlet using an extension cord. If a power
outlet is not available, one should be
installed by a qualied electrician.
Never operate this appliance if the unit is
damaged. Call the retailer rst. Ensure the
power cord is not stretched or exposed to
sharp objects or edges.
If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent or similarly qualied persons in order
to avoid a hazard.
An authorised service representave
should perform any service other than
regular cleaning or lter replacement.
Failure to comply could result in a voided
warranty.
The unit must be disconnected from the
power prior to any cleaning, maintenance
or servicing.
The unit must only be opened by a suitably
competent engineer when the power is
disconnected and aer reading the service
manual.
Do not use the appliance for any purpose
other than its intended use.
Do not �lt the unit while in use. The unit is
designed to work only in a vercal posion.
This dehumidier must always be stored
upright; otherwise, irreparable damage
may be caused.
background
smaller than 4m .
35
5
Avoid restarng the dehumidier un�l 5
minutes have passed a�er it has been
turned o.
Never use the mains plug as a switch to
start or turn o the dehumidier. Instead,
use the power buon provided on the
control panel.
Always place the unit on a dry and stable
surface.
The appliance should not be installed in a
laundry or wet room where the humidity is
higher than 85% RH. This unit should be
operated at an ambient temperature
between 5°C and °C.
Do not dry laundry directly above the unit.
To prevent water from entering the
dehumidier, laundry should be placed at
least 40 cm away from your dehumidier.
Do not place the unit next to heat sources
(e.g. electrical fires, replaces, etc.)
Do not store or use gasoline, petrol, paint,
solvents or other ammable vapours and
liquids in the vicinity of this dehumidier or
any other appliance. Do not use
dehumidiers where ammable gases or
VOC can be released or accumulate.
Refrigerants can be odourless; if the casing
is damaged, please do not use the unit and
contact the retailer.
Do not use or store the unit in a room
2
ENERGY SAVING AND UNIT SAFETY
PROTECTION TIPS
Do not cover or restrict the airow from the
outlet or inlet grills.
For maximum performance, the unit should be
operated at least 20 cm away from walls and
50 cm from other objects within the room.
Whilst storing the unit when not in use, ensure
the same ven�laon clearances as in
operaon. Do not store anything on top or
leaning against the unit.
Always store the unit in a dry room away from
direct sunlight.
Keep the appliance's filters and grills clean.
Under normal condions, filters and grills
should only need cleaning once every three
weeks (approximately). Do not use the unit
without the mesh air filter, as this will allow
dirt to gather inside the dehumidier, which
could invalidate the warranty.
A dirty filter restricts the airow into the
machine, increasing the resistance of the fan.
This can damage the unit and invalidate your
warranty.
Since the filters remove airborne parcles,
more frequent cleaning may be necessary
depending on the air quality. Vacuum and
wash the mesh lters with hot, soapy water
and dry them before placing them back in the
unit.
WARNING SYMBOLS
Read the operang
instrucons.
Read the operator's
manual.
Read the
service/technical
manual.
background
6
Q
UICK VISUAL SAFETY GUIDE ON WHERE OR WHEN NOT TO USE
YOUR DEHUMIDIFIER
E
xposed to the weather
outdoors
Near water If the power cable wires
are frayed or cut.
Where small children may be
le una ended
If an extension lead
becomes overloaded
Where it may be
damaged by
chemicals
Where the power cable
may be damaged
Where there is a risk of
interference by foreign
objects
On a slope or uneven
surface
This product is not
for DIY repair
Where there is a risk of
re or close to a naked
ame
Where there is a risk of water
falling on the unit
INFORMATION ON INDOOR POLLUTANTS
VOC (Volatile Organic Compound): VOCs come from motor vehicle exhausts, gasoline vapour, pollutants
such as formaldehyde, ammonia and many other common and chemical solvents such as paints and glues,
or can be a by-product of mould growth. VOCs irritate the eyes and or nose as well as cause headaches,
rooms, paint and cleaning solvents are common sources of VOCs.
Mould/Fungus:
Other indoor pollutants include bacteria, viruses, dust mites and pollen.
Emissions from electronic office equipment: Many studies, including those from EPA and the University of
California Berkeley, have reported that emissions from office equipment such as computers and printers
on the health of many people, and these can be reduced by using an air purifier.
Using HEPA and Carbon filters:
odours and reduce the VOC content in the air.
background
APPLIANCE DIAGRAM
Control Panel
Louvres
Air Outlet
Power Cable
Castors
Handle
Air Inlet
Pre Filter
us Drain Port
Water Tank
7
HEPA f ilter
(oponal)
Carbon f ilter
(oponal)
Water pipe
(oponal)
background
HEPA FILTER AND CARBON FILTER
An oponal HEPA filter and carbon f ilter can be purchased (available separately) for use with these
dehumidif iers. They are available under the part code: FIL-CDLECGM / FIL-CDLEHEPAGM
Note: Diagrams within this manual are for illustrave purposes only and may dif fer from the actual item.
Unclip the f ilter housing.
Remove the f ilter housing and
f it the f ilter.(If required)
Ensure the f ilter housing is securely
clipped into posi�on.
8
1.
Easy-to-use controls.
2.
Low energy only uses a fraction of the electricity of similar dehumidifiers.
3.
Cost-effective way to combat mould, condensation and dampness.
4.
Dries laundry more efficiently than a tumble dryer.
5.
Designed to complement any modern
space.
6.
Castors for improved mobility.
7.
Intelligent CPU-controlled digital humidistat with 35-80% RH and room humidity display.
8.
Quiet vs turbo fan operation ensures the right balance between quiet operation
and maximum
dehumidification.
9.
24-hour start/ stop timer.
10.
Tank operation or permanent drainage option with splash proof tank.
11.
Tank full alarm and auto-stop function.
These dehumidifiers use compressor technology to extract water from the environment. They are ideal for
normal domestic or office environments that are heated during the winter months and maintain a
temperature above 12-15C.
This dehumidifier is easy to move around on castors and is designed to extract unwanted humidity while
saving money due to its power-saving logic. It features
an
i
ntelligent humi
distat where the desired relative
humidity can be adjusted in increments of 5% between 35 and 80%, ensuring the air in your room is not too
dry and that power is not wasted.
Remove any water from within the water tank before starting the unit. To save energy, do not open windows or
doors while the unit is running. Place the unit on a hard/flat surface. On first use, run the unit continuously for
24 hours.
TO REDUCE NOISE LEVELS: Place a piece of carpet or a rubber mat under the unit to reduce vibrations while
it is running. Also, ensure it is placed on a flat-level surface.
FITTING THE OPTIONAL FILTER
The optional HEPA and carbon f ilter (available separately under part code: FIL-CDLECGM / FIL-
CDLEHEPAGM) can be fitted within the filter frame on the rear of the unit.
FEATURES
Your dehumidifier belongs to the electriQ dehumidifier range, featuring power-saving logic
and advanced
air purification
.
background
CONTROL PANEL
POWER Button
Turn the appliance on/o .
MODE Button
You can select the unit's
Air Purif ier
,
and Laundry.
g mode b
etween Smart, Dehumidify,
INCREASE AND DECREASE Buttons
Use the INCREASE and DECREASE bu ons to select the desired rela ve
humidity level in dehumidify mode; the default is 55% and can be adjusted
in 5% increments . When a relave humidity of 35% is selected, the
compressor will not stop un l the water tank is full.
9
SMART MODE: The unit will default to SMART mode the f irst me it is
switched on and remains in this mode unl another program is chosen. In
smart mode, it will aim for a relave humidity of 55% and adjust the fan
based on humidity level. This mode is ideal and is the recommended mode,
as the compressor will only run when necessary. This saves energy and
keeps your room at the ideal humidity.
AIR PURIFIER: In this mode, only the fan will run, and water will not be
extracted. You can select the fan speed you desire. This is to be used in
conjuncon with the oponal f ilters, but it can also be run without the f ilters
to work as a fan.
DEHUMIDIFY: The unit removes moisture from the air. The increase and
decrease buons allow you to set the desired humidity level between 35%
and 80%. In this mode, you can also change the fan speed.
LAUNDRY: The dehumidif ier runs connuously at the highest fan speed,
and the target humidity is 35% to remove the most moisture possible, which
is ideal for drying clothes. This will not turn off unl you turn it off or the
tank is full.
SPEED Button
Press the SPEED button to change the fan speed to Quiet, Medium or Turbo.
CHILD LOCK
Hold the buon for 3 seconds to lock the control panel, and hold it for 3
seconds again to unlock it. When locked, the indicator will be lit, and all
buons other than the lock will be disabled.
background
10
SWING Butt
on
SLEEP
INTELLIGENT DEFROST
The appliance defrosts automacally when the coil sensor detects that the
internal temperature is too low. During defrosting, the fan speed is TURBO,
and the indicator flashes. Once the defrost cycle has finished, the appliance
returns to its previous operating mode if it was previously on SMART,
SLEEP, DEHUMIDIFY or LAUNDRY.
TIMER But
ton
Press the TIMER bu on to program the mer. When the mer is ac vated,
the "TIMER" light will illuminate. When the light is , the mer is
deac vated. The following mer programs are available.
DELAYED POWER-ON FUNCTION: With the appliance on standby, press
the TIMER bu on, then use the increase and de
crease b ns to set in how
many hours you require the unit to start (0~24 hours).
DELAYED POWER-OFF FUNCTION: While the appliance is running with
the desired se ngs, press the TIMER bu on, then use the increase and
decrease bu ons to set in how many hours you require the unit to stop
(0~24 hours).
Humidity/Temperature Toggle Button
When the unit is powered on, both the front panel and the control panel
display the current humidity — this is the default mode.
Pressing the Humidity/Temperature Toggle Buon cycles through the
following display configuraons:
Press once: Front Panel displays Humidity; Control Panel displays
Temperature
Press twice: Front Panel displays Temperature; Control Panel displays
Humidity
Press three mes: Front Panel displays humidity; Control Panel displays
humidity
TANK-FULL
When the water tank is full, the TANK FULL indicator light will ash, and the
unit will stop opera ng. Once emp ed and replaced, the ap
pliance will
resume opera on.
OPTIONAL CARBON AND HEPA FILTERS (Air purification function)
Insert the f ilters into the f ilter housing. It is suggested to hoover the f ilters
every 2-3 weeks and change them every 3-6 m onths, as this will help to
ensure the room is kept fresh and odour-free.
background
11
The led indicator performs the following funcons:
1.
When the unit is plugged in, it will indicate the humidity level/temperatu re
of the room.
2. When the increase and decrease bu ons are pressed, it will indicate t he
desired humidity currently set, then revert back to the current humidity
/temperature.
When the mer is programmed
, it will show the d inpu ed befo re
rever ng back to the current humidity/temperature.
3.
IMPORTANT:
HUMIDITY LEVEL
& TIMER 2 DIGIT DISPLAY
Note: If the ambient humidity is lower than 20%, it will show “LO.” If i t is higher than 90%, it will show “HI
.”
There is also a display on the front of the unit to give a visual indic a on of the
current humidity level of the room.
RED = Excessive humidity > 70% (uncomfortable: high mold risk
ORANGE = Elevated humidity 60–70% sticky, less comfortable
GREEN = Ideal humidity < 60% pleasant, healthy
OTHER FEATURES AND INDICATORS
TANK FULL LIGHT
When the water tank is full, removed or incorrectly inserted, the unit will stop dehumidifying, the tank full light
will illuminate, and the unit will beep. Empty the tank and reinsert it correctly to resume operaon.
AUTO DEFROST
When frost builds up on the evaporator coils, the compressor cycles o, and the unit goes into defrost mode.
Following the defrost mode's compleon, the unit returns to its previous operang sengs.
The unit will defrost more frequently if the room humidity is high or if the ambient temperature is cold. The
defrost mode lasts 8-11 minutes.
HUMIDISTAT CONTROL AND FAN/COMPRESSOR OPERATION
When the room humidity is 2% lower than the desired humidity, the compressor will turn off
automatically.
When the humidity of the room is equal to or higher than the desired humidity, the compressor will
restart after a 3-minute delay to protect the compressor.
AUTO-RESTART
If the unit stops unexpectedly due to the power cut, it will restart with the previous funcon selected
automacally when the power resumes and the 3-minute compressor protecon has elapsed.
POWER
Aer the unit has stopped, it is not recommended to resume operaon for at least 5 minutes to protect the
compressor. The operaon can resume aer this period lapses. When the unit is restarted, there is a 3-minute
delay before the compressor starts.
background
12
QUICK REFERENCE GUIDE
Power Button: Press to turn the dehumidif ier on and off.
SMART Mode: This is designed for maximum convenience and defaults to the ideal
dome
environment humidity level of 50-55% while saving electricity. This is the
default mode and is recommended for most users.
During opera on, the compressor will operate un l the desired humidity is reached and then stop. The fan
moves the air around the room, ensuring the en re air in the room is processed and humidity is correctly
measured.
DEHUMIDIFY MODE: This is the standard opera ng mode for which the desired humidity can be set using
the increase and decrease bu ons.
Incre
ase and Decrease Buttons: When in dehumidify mode, the unit will display the
current rela
ve humidity, these bu ons can be used to adjust the desired humidity
level. The desired rela ve humidity can be set between 35 and 80% in 5% increments.
Timer: Press the mer bu on, then use the
the mer (1-24 hrs, start/ stop mer).
bu ons to adjust the d n of
LAUNDRY MODE: When drying clothes, the dehumidif ier should operate connuously with maximum water
extracon unl the water tank is full. Do not place clothes directly over any of the dehumidif ier's vents. Make
sure that nothing is blocking the hot air exhaust airflow, and for best results, place the laundry within 1.5
meters of the dehumidif ier.
If set while the unit is running: The number will represent the number of hours the unit will operate before
turning off. This will not be affected if the unit enters defrost mode or the tank is emptied and reinserted.
If set while the unit is on standby, the set number represents the period in hours after which the unit will start.
To cancel start/stop mode, press the timer key again.
NOTES:
If a permanent drainage pipe is fitted, the unit will not stop operating. Setting the desired humidity to
around 35% is good for laundry mode, a quick drying boost, or in emergencies. It is not recommended
for long normal operation in a domestic or office environment.
To allow more moisture in the air, press the up button and set the humidity to a higher desired level
(e.g., 60-70%).
We recommend setting the Humidity to 50-55%. This is great for domestic operation and dry storage.
Setting the humidity to 60% is great for personal comfort and applications where 50% RH is
considered too dry.
Setting the humidity to 70% is ideal for unoccupied properties or where an economical run is needed
without the need to reduce the humidity further.
background
13
POSITIONING THE DEHUMIDIFIER
A badly posioned dehumidif ier will have lile effect. When posioning the dehumidif ier, please ensure air
circulaon is not restricted around the unit.
Allow at least 20 cm of space around the unit. This dehumidif ier is designed only for indoor residenal or small
of f ice applicaons, and any commercial or industrial use will invalidate the warranty.
For maximum efficiency, use in an enclosed area, closing all doors and windows to create an effective operating
environment. Do not use outdoors.
Your electriQ dehumidifier will begin to protect your space from the harmful effects of excessive moisture as
soon as it is turned on. Excess moisture is dispersed throughout your home. For this reason, the dehumidifier
should be positioned in a central and clear location so that it can draw this moist air towards it from all over
the home. A warm hallway or landing is an excellent position for your dehumidifier. If possible, leave interior
doors ajar to allow air circulation.
Alternatively, if you have a serious problem in one area, you can begin by positioning the dehumidifier there
and moving it to a more central location later. For the most effective use, run your dehumidifier with external
doors and windows kept closed. Please note that the unit should not be placed directly against a radiator or
other heat source.
Before moving the appliance, the water tank should be emptied. The handle on the appliance is designed to aid
in its movement and should not be used to support the full weight of the dehumidifier. When carrying the unit,
it should be kept upright and sufficiently supported from its base. The handle should not be used if there are
any signs of damage to its fixings.
When positioning your electriQ dehumidifier, ensure that it is clear of any obstacle that may limit air
movement. Place the dehumidifier on a flat, dry surface.
Note: Do not force castors to move over carpet or uneven surfaces, nor move the unit with water in the tank,
as it may tip over and spill water.
background
·
·
·
When you remove the water tank, please do not touch
the sensors or any parts behind it. Doing so may
damage the product.
Be sure to push the tank gently all the way into the
unit. Banging the tank against anything or failing to
push it in securely may cause the unit not to operate.
Do not remove any parts from the water tank or tank enclosure. The full water sensor will no longer
be able to detect the water level correctly, which may result in a leak.
14
water tank
handle
WATER DRAINAGE
When the water tank is full, the unit stops automatically. The TANK FULL light illuminates on the control panel.
NOTE: Only empty the water tank when it is full or before moving, turning off or storing the unit.
There are two ways to dispense collected water.
1. USE THE TANK
When the tank is full, the unit will automatically stop running,
and the Tank Full indicator will flash.
Slowly pull out the tank. Securely grip the tank by its handle and
carefully pull it out. Empty the water tank and reinsert it into
the dehumidifier. The tank must be in place and securely seated
for the dehumidifier to operate again. The dehumidifier will
restart when the tank is restored to its correct position.
NOTES:
2. CONTINUOUS DRAINAGE (PIPE NOT SUPPLIED)
Water can be automatically plumbed in or drained into a sink, a larger container, or through the wall into an
outside drain by attaching a pipe (10 mm internal diameter) to the unit. Insert the pipe into the drain outlet at
the back of the unit, as shown here.
Make sure the connection between the pipe and the drain outlet is tight and does not leak. Then, direct the
pipe to a suitable drainage point.
This unit uses gravity to dispose of water, so the drain should be lower than the water outlet on the
unit.
The water tank must be in position in the unit for it to operate.
Be sure to run the water pipe downward and let the water flow out smoothly.
Do not kink or bend the pipe.
The maximum pipe length is 1 metre. For longer distances an uplift pump must be used.
The permanent drain can be used in conjunction with a water pump (e.g. when draining from a cellar) to lift the
water upwards.
background
15
CARE AND MAINTENANCE
Always shut off the unit and unplug from the mains before cleaning or performing any maintenance. When it is
not in use for long periods, it is advisable to remove the plug from the power socket. Do not use chemical
solvents (such as benzene, alcohol or gasoline), as they may cause irreversible damage to the unit.
1 . CLEAN THE GRILLE AND CASE
Use water and a mild detergent to clean the
washable mesh f ilter. Do not use bleach or
abrasives. Do not splash water directly onto the
main unit. Doing so may cause an electrical
shock, deteriorate the insulaon, or cause the
unit to rust. The air intake and outlet grilles get
soiled easily, so use a vacuum aachment or so
brush to clean them. Wipe the dehumidif ier
body with a so, damp cloth or kitchen towel.
1.
Empty and clean the water tank.
2.
Clean the unit and the f ilters as per the cleaning procedure above.
3.
Cover the unit and keep it in a dry place.
water. Clean the tank every few weeks to prevent the growth of mould, mildew, and bacteria. Par
NOTE:
securely into a dehumidif
END-OF-SEASON MAINTENANCE
f ill the
Remove the f ilter housing. If the oponal filters are f ied, remove them from the frame and hoover gently
approximately every 2-3 weeks.
If the mesh f ilter is dirty, hoover it. If it is heavily soiled, wash it with warm, soapy water and dry thoroughly
before reinserng it in the unit. When f ilter cleaning is f inished and the f ilters are dry, place them back into
the unit. The oponal filters should be replaced every 3-6 months.
NOTE: While the HEPA and Carbon f ilters are oponal, never run the unit without the mesh filter housing
correctly inserted.
2 . CLEAN THE WATER TANK
background
16
TROUBLESHOOTING
Issue Cause Solution
Hot or cold air
being
produced
Normal Operaon
When the unit is in dehumidifying mode it absorbs humid air from
room and freezes it to reduce the humidity.
During the cold cycle there should be cold air coming out of the un it.
During the defrost cycle hot dry air should be coming out of the
outlet grill.
Unit does not
operate
Is the plug properly
inserted in the socket?
Insert the plug into the socket and ensure the socket is switched
on.
Is the tank full indicator
lit?
Tank full, float
displaced or tank not properly inserted. Empty tank,
checkoat and make sure tank is properly inserted in unit.
Front louvres
do not open
Louvre motor is blocked
Check if anything is blocking the louvre.
Try to move the louvres gently increase and decrease while the unit
is off. If the above fails return the unit to service centre
does not
extract water
Is the unit set to a
humidity level lower than
the humidity of the room?
Set the humidity level on the humidistat below the current
humidity reading.
Is the temperature too
low for water extracon
to be efficient?
Increase temperature in the room or reposion the unit.
Is any intake grill or outlet
blocked? Is the unit t oo
close to the walls?
Remove obstrucons and restart the unit.
Ensure a distance of at least 20 cm between the unit & walls
Airow seems
weak
Unit is noisy
during
operaon
Is the unit on an uneven
surface?
Please place on at horizontal surface. Where possible this should
be so such as rubber or carpet to prevent vibraons.
E3 or E4 Humidity sensor error
Use the unit within the prescribed humidity range. Unplug the unit,
rest and plug it back in. If error repeats, call the service centre.
E1 or E2 Temperature sensor error
Use the unit within the prescribed temperature range. Unplug the
unit, rest and plug it back in. If error repeats, call the service centre.
E5 or E6
Abnormal Coil sensor
temperature or current
Use the unit within the prescribed humidity and temperature
range. Unplug the unit, rest and plug it back in. If error repeats, call
the service centre.
Defrost light
on and unit
stops regularly
Unit is defrosng
Allow the unit to automacally defrost. The protecon will clear
aer the unit self defrosts. Increase the temperature in the room if
this repeats too oen
Tank full light
Any other malfuncons will need to be reported to electriQ service centre. Do not aempt unauthorised repairs as
these may invalidate the warranty.
Tank is full or is not in the right posion- Empty the tank and
replace in the right posion.
Dehumidif ier
Are the f ilters dirty or
clog
ged?
Is f i
lter clogged? Please service the f ilters regularly as per user manual.
Please service the f ilters regularly as per the user manual.
Water tank full
nof icaon
background
1
7
Mo
del CD12LE-V4
CD20L
E-V5
Voltage
220-240V 50Hz
Dehumidifying capacity
12 L / day
(at 30
C / 80%RH)
20 L
/ day
(at 30
C / 80%RH)
Fan Speeds
3
Rated Input Power
190W 250W
R
ated Current
0.9
Amps 1.18 Amps
Tank Capacity
5 litres
Desired Humidity Range
35 – 80%
IP Ra ng
IPX1
Refrigerant
R290,45grams
R
290,70grams
Air ow m
3
/
h
170
High / Low Pressure
3.2/0.7MPa
Filters
Dimensions mm (WxDxH)
370*233*608mm
Weight kgs
11.8 14
GWP
3
HEP
A filter: FIL-CDLEHEPAGM (oponal)
Carbon filter: FIL-CDLECGM (oponal)
FREQUENTLY ASKED QUESTIONS
Why doesn’t the dehumidifier seem to extract much water if the temperature is low?
This is a compressor dehumidier which works best in temperatures above 15C. If the temperature is low
and the air is drier than the seng on the humidistat the unit will not extract water. If you want to use a
dehumidier for outside buildings, unheated properes, boats or garages please check our desiccant range.
Why doesn’t the unit work /or stops suddenly?
The water tank may be full or displaced. To recfy, empty the tank and carefully place it back in the unit. Also,
the unit may be running in dehumidifying mode with a low room temperature. Please check if the room
temperature is lower than 5C. If so, the unit will stop working while in dehumidifying mode. (The unit may
be defrosng.)
The ambient operang range is between 5
C and 35C with a relave humidity ranging from 30% to 80%.
For maximum eciency use the unit between 15C and 32C.
Sometimes cold and/or hot air comes out from the air outlet grill, why?
When the unit is in dehumidifying mode it absorbs humid air from room and freezes it to reduce the
humidity.
During the cold cycle there should be cold air coming out of the unit.
During the hot cycle hot dry air should be coming out of the outlet grill.
TECHNICAL DATA
background
18
electriQ UK SUPPORT
www.electriQ.co.uk/support
Please, for your own convenience, make these simple checks before calling the service line.
1. Has the unit been standing upright for at least 2 hours?
2. Is the unit plugged into the mains?
3. Is the fuse OK?
4. Switch the unit off and wait three minutes to see if the issue is resolved. Restart the unit.
5. Check if the water tank is full.
6. Was the troubleshooting guide followed?
If the unit still fails to operate call: 0330 390 3061 or complete the online form
Office hours: 9AM - 5PM Monday to Friday
Unit 2A Trident Business Park,
Neptune Way, Leeds Road,
Huddersfield, HD2 1UA.
Recycling facilities are now available for all customers at which you can deposit your old
electrical products. Customers will be able to take any old electrical equipment to
participating sites run by their local councils. Please remember that this equipment will be
further handled during the recycling process, so please be considerate when depositing your
equipment. Please contact the local council for details of your local household waste
recycling centres.
background
background

Specifications

Indexed Terms: Laundry Dehumidifier, Quiet

ElectriQ CD12LE-V3 Questions and Answers

Questions and Answers

Related Products