Perlick G5BD24SC 24-Inch Undercounter Beverage Dispenser with 5.1 Cu. Ft. Capacity, RAPIDCOOL Technology in Panel Ready

Product's Documents

Below are documents related to this product, you can read online or download:
Installation Instruction Specification Other Documents
  • G5 Toe Kick Template - (English) Download
  • Stainless Steel Care and Cleaning Guide - (English) Download
  • G5 Solid Panel Overlay Template - (English) Download
  • Hardware Kit for Toe Kick Panel - (English) Download
G5BD24SC photo

Installation Manual

This is the main product document for model G5BD24SC. Additionally, the document applies to other Perlick models: G5BD24SC

The file format is pdf, 16 pages, you can download this manual here .

background
Form No. Z3025
Rev. 10.01.25
INSTALLATION MANUAL
FOR BEVERAGE DISPENSING EQUIPMENT
background
background
Perlick customer service (800)558-5592 | 3
Beverage Dispensing Installation Manual
CONGRATULATIONS
Congratulations on your purchase of a Perlick high
quality residential Beverage Dispenser. Perlick has
proudly manufactured Beverage Dispensing systems
for over 50 years for bars, restaurants, stadiums,
arenas and large venues around the world. That same
technology is used in each and every residential
Beverage Dispenser we produce, assuring you’ll pour
fresh, cold beer as the brewery intended it to be
enjoyed.
All Perlick products are built with commercial grade
stainless steel, providing you with the beauty and
durability for a lifetime of use. This installation guide
will show you how to properly install the dispensing
equipment on your Perlick Beverage Dispenser.
We dedicate considerable time to ensure that our
products provide the highest level of customer
satisfaction. If, however, service is required, call Perlick
at 800.558.5592. For your own protection, never
return merchandise for credit without our approval.
We thank you again for selecting a high quality Perlick
Beverage Dispenser. Cheers!
IMPORTANT!
Make sure the hole in the countertop and
the hole in unit are inline to ensure proper
installation of the pvc sleeve.
DANGER
Keep CO2 cylinder away from
heat. Rupture disc vents at 122°F
maximum.
DANGER
Do not drop or throw regulator or
CO2 cylinder.
CAUTION
Allow only properly trained and
experienced personnel to handle
high pressure gas.
CAUTION
Do not apply oil to the
regulator!
PLEASE NOTE
The following instructions are for both the Draft Arm
and the Adara Tower.
Some photos and drawings may only show the Draft
Arm, but the instructions will also apply to the Adara
Beer Tower unless noted.
WARNING: California Prop 65 Notice
These products may expose you to chemicals including
Chromium, which are known to the state of California
to cause cancer and birth defects or other reproductive
harm. For more information on whether a product in this
list contains these chemicals, please refer to the specic
product page at perlick.com. Or to nd out more about
Prop 65, go to P65Warnings.ca.gov.
background
4 | perlick.com/residential
Beverage Dispensing Installation Manual
BEVERAGE DISPENSING COMPONENTS LIST
Description 66585-1 66585-2 69862-1 69862-2 Unit Of Measure
Draft Arm - Single
Faucet
1 - - - EA
Draft Arm - Dual
Faucet
- 1 - - EA
Adara Tower - Single
Faucet
- - 1 - EA
Adara Tower - Double
Faucet
- - - 1 EA
Beer Line 6.5 13 6.5 13 FT
CO2 Line 4.2 13.8 4.2 13.8 FT
CO2 Regulator 1 1 1 1 EA
Misc. Hardware 1 1 1 1 EA
Faucet Handle 1 2 1 2 EA
Low Prole Keg
Coupler
1 2 1 2 EA
Air Snorkel Tube 1.3 1.3 1.3 1.3 FT
CO2 Cylinder - 5LB 1 1 1 1 EA
Surface Mount Drainer 1 1 1 1 EA
Drainer Insert 1 1 1 1 EA
Insulation Sleeve 1 1 1 1 EA
Beer Faucet 1 2 1 2 EA
2-Way Air Distributor - 1 - 1 EA
Air Sleeve 1 1 1 1 EA
background
Perlick customer service (800)558-5592 | 5
Beverage Dispensing Installation Manual
INSTALLATION OF DISPENSING EQUIPMENT
Open the beverage dispensing kit box and become
familiar with its components. The instructions on
pages 8 through 12 will demonstrate how to properly
install the beverage dispensing equipment on your
new Perlick Beverage Dispenser.
Draft Arm
Faucet Lead
Apply silicone to
bottom ange
Air Distributor
Flange Sleeve
All hose
connections use
worm-drive hose
clamps (view
enlarged to verify)
Distributor is only on
multiple keg units,
each keg is connected
to a valve on the air
distributor. Single keg
is connected directly
to the regulator.
Keg
Keg Coupler
Beer Connection
NOTE: Image does not accurately reflect positions of
the different elements within the unit. Positions and
hose lengths shown are to clearly illustrate proper
connection methods only.
background
6 | perlick.com/residential
Beverage Dispensing Installation Manual
Figure 2.
PVC SLEEVE
INSTALLATION OF DISPENSING EQUIPMENT
Open the beverage dispensing kit box and become
familiar with its components. If the dispensing head is
going to be mounted on a counter top directly above
the refrigerated cabinet, have the counter top pre-
drilled using the supplied template on page 13. NOTE:
Make sure the access holes in the refrigerated cabinet
is in line with the counter top holes so the PVC sleeve
can be installed all the way through the fridge cabinet.
Remove any obstructions from the access hole of the
refrigerator.
Follow instructions on pages 8 through 12 to properly
install the beverage dispensing equipment on your
perlick unit.
NOTE: Wash beverage dispensing devices
thoroughly. Flush beverage and faucet lines,
as well as the beverage dispensing device
(keg coupler) with fresh water.
IF YOU ARE INSTALLING A DRAFT ARM - SKIP TO PAGE 8. THE FOLLOWING INSTRUCTIONS ARE
ADDITIONAL PREPARATION STEPS FOR THE ADARA DISPENSING HEAD ONLY
1. Mark the air tube for correct length dependent upon your installation scenario. If installing directly on top of
the refrigerated cabinet, make a mark 5 inches from the bottom of the tower (Figure 1). If installing directly
on top of a countertop, add the depth of the countertop to the original 5 inches and mark at that new
dimension (Figure 2).
Figure 1.
Figure 2.
background
Perlick customer service (800)558-5592 | 7
Beverage Dispensing Installation Manual
2. Remove air “T” from end of air tube by loosening fastener holding the two halves together. Remove the air
tube from the tower being careful not to damage the product tube.
3. Cut air tube at mark made in step 1. Re-install air tube into tower and re-install “T” on the end of the air tube
so “T” faces the rear of the tower.
4. Cut product tube 3 inches below the “T” and install included barbed union into product tube and clamp using
worm drive clamp.
Figure 3.
Figure 4.
background
8 | perlick.com/residential
Beverage Dispensing Installation Manual
Locate the dispensing head , black beverage line(s),
and hose clamp(s). Slide one end of each beer line
onto the stainless steel tubes which protrude out the
bottom of the dispensing head and clamp tight.
1.
Remove transit tape with a utility knife around the
hole in the top of the unit from both inside and outside
of the cabinet. Gently punch out foam w/screwdriver
and remove.
2.
For countertop installations only - The PVC sleeve is
used to create an airtight seal between the countertop
and inside of the refrigerator cabinet. Feed the PVC
sleeve from the top and hold it approx. 1/8” higher
than the countertop. From the inside, mark the sleeve
at the roof of the cabinet. Cut the PVC Sleeve to
length.
3.
background
Perlick customer service (800)558-5592 | 9
Beverage Dispensing Installation Manual
Insert end of the snorkel up into the tower and screw
air scoop mounting bracket into holes above the fan.
6.
For Countertop installations only – Using the
provided Silicone, seal the upper edge of the PVC
sleeve to the countertop and the lower edge of the
PVC sleeve to the top of the refrigerator cabinet.
4.
Assemble components from the kit as follows –
Insert black snap bushing into air scoop mounting
bracket, then insert one end of the air snorkel
through the snap bushing. A zip tie can be inserted
behind the mounting bracket to keep the tube in
place.
NOTE: For Adara Towers, the air snorkel consists of
a 3 inch piece of black tubing and a 3 inch piece
of clear tubing that slides over each other and then
is clamped using included worm drive clamp. The
black tube is inserted per the above instructions and
secured with the included zip tie. The clear tube is
installed over the air “T” from the dispensing head
and secured with the included worm drive clamp.
See Figure 4 on page 7 for illustration.
5.
background
10 | perlick.com/residential
Beverage Dispensing Installation Manual
Pick up tower and insert the beer line(s) through the
hole in the counter top. Move head aside and bead
silicone around perimeter of hole, and then position
the head back in place. Fasten using the 4 chrome
screws included with the dispensing head. Wipe off
excess silicone to complete the seal. Be careful not
to dislodge the PVC Sleeve.
7.
If installing a two faucet system, a CO2 manifold
will need to be installed. Locate the red CO2 lines,
CO2 manifold and a #10 x 1/2” sheet metal screw.
Slide one end of each hose onto the barbed ttings
on the manifold and clamp. On the left rear side
wall of the beer compartment there is a double
row of screws which run vertically. Remove one of
the two top screws and discard. Insert the sheet
metal screw through the manifold and into the hole
vacated previously.
8.
On a single beer system, locate the red CO2 hose.
Slide one end onto the barbed tting of the regulator
assembly and clamp. On systems with two beers,
locate the CO2 line that comes off the backside
of the manifold assembly. Slide the hose onto the
barbed tting of the regulator assembly and clamp.
For detailed information on connecting the regulator
to the CO2 cylinder, see page 12.
9.
background
Perlick customer service (800)558-5592 | 11
Beverage Dispensing Installation Manual
CO2 tanks are shipped empty and must be lled
prior to use. Turn the adjusting knob on the regulator
counter-clockwise until the secondary gauge
(top) reads zero. Make sure that the valve at the
bottom of the regulator where the red hose is
connected is in the off position as shown. Watching
the secondary pressure gauge, turn the regulator
adjusting knob clockwise until the pressure is at 15
psig. Adjustments can later be made based on ow
rates. IMPORTANT: All pressure adjustments MUST be
made when the shut-off valve is in the OFF position!
12.
Locate the low prole keg coupler(s). Slide one of
the red CO2 lines onto the larger barbed tting of
coupler and clamp. Locate one of the black beer
lines and slide onto the smaller barbed tting of the
coupler and clamp. Repeat for additional couplers.
Note: This unit comes
standard with Perlick’s new
304SS Lo-Boy coupler
(40030SSLD)
10.
A Safety chain is provided to prevent CO2 tank tip
over. On the right rear sideway there is a pre-drilled
hole for the safety chain screw. Locate the safety
chain and a #10 x 1/2” sheet metal screw from
the parts bag. Insert the screw through the closed
end link of the chain and tighten in the vacant screw
hole. The chain can now be used to secure the tank
with “S” hook, preventing damage to the regulator.
11.
NOTE: To rell C02 tanks, search online or contact
your dealer for nearest location.
background
12 | perlick.com/residential
Beverage Dispensing Installation Manual
Locate the beer faucet(s) and install onto the
dispensing head shanks. Tighten with supplied
spanner wrench. Install black handle(s) onto
faucet(s).
13.
14.
CONNECTING THE REGULATOR TO THE CO2 CYLINDER
1. Remove the blue plug from the regulator tting, but do
not remove the carbonic washer.
2. Screw regulator onto gas cylinder valve. Tighten with
wrench until vertically straight. Be sure that the shut-off
valve on the regulator is in the OFF (horizontal) position.
3. Place screw clamp over the end of red line and push onto
regulator tail piece. Tighten clamp with a screwdriver.
4. Turn regulator adjusting screw counterclockwise until it
turns freely.
5. Turn hand valve counter-clockwise on the CO2 cylinder
to the fully open position.
6. Turn regulator adjusting screw clockwise until desired
pressure is reached (approximately 12-15 lbs.) Tighten
stop nut on adjusting screw.
7. Open shut-out valve on bottom of regulator.
8. Dilute a small amount of liquid dishwashing soap and
rub the soapy mixture around connections. If bubbles
appear, tighten connection.
Before beverage dispensing, make sure the beer
faucet is closed. To tap a keg, insert the coupler into
the neck of the barrel. Turn the coupler clockwise
until it stops (about an 1/8 turn), then push down on
the top of the coupler and again turn clockwise until
it stops. Your barrel is now tapped. Open the CO2
valve on the regulator as well as the valve on the
manifold if used.
background
Perlick customer service (800)558-5592 | 13
Beverage Dispensing Installation Manual
ATTENTION INSTALLERS
THIS IS A FULL SIZE TEMPLATE.
PLEASE CONFIRM THAT PRINT
DIMENSIONS ARE TO SCALE
PRIOR
TO INSTALLATION.
MOUNTING HOLE TEMPLATE FOR DRAFT ARMS
AND ADARA SIGNATURE TOWERS
NOTE: The hole placement for the Draft Arm
and Adara towers are the same even though the
decorative flanges are different shapes.
background
14 | perlick.com/residential
Beverage Dispensing Installation Manual
background
Perlick customer service (800)558-5592 | 15
Beverage Dispensing Installation Manual
background
Form No. Z3025
Rev. 10.01.25

Specifications

Perlick G5BD24SC Questions and Answers

Questions and Answers