Installation guide
Billi Home C
(913000)

2
Components for Billi Home C
Before commencing installation,
ensur
e you have identified the following.
1. Chilled Water Module
2. Installation Requirements
3. Installation Hardware and Dispenser
4. Warranty
Water Suppl
y
A single cold water supply is required.
Supply Pressure: 200 – 1000 Kpa
Supply Temperature: 5°C – 30°C
Do not install with water that is
microbiologically unsafe or with water of
unknown quality without adequate disinfection
before or after the system. Systems certified
for cyst reduction may be used on disinfected
water that may contain filterable cysts.
Power Requirements
A single 10 amp standard power outlet is
required. Chiller module is supplied with
1 metre of flex cord and plug.
Drainage
A drainage point, such as a dishwasher nipple
or a tundish, is required.
Installation
requirements.
Diagram 1
Power
Outlet
800mm
Tube Length
Supplied
Stop Tap
(Installed by Plumber)
Max 450mm from Unit
bench
thickness
1mm-37mm
Diagram 2
113mm
Cupboard Dimensions:
220mm Minimum Width
550mm Minimum Depth
233mm
37mm

3
Installing the
dispenser.
IMPORTANT: This Billi appliance is to be installed by a licensed trades person in accordance with
AS/NZS 3500.1 and AS/NZ 3500.2 and in compliance with applicable state regulatory requirements.
For correct operation of this appliance, it is essential to observe the manufacturer’s instructions.
1. Determine Component Location
A stop tap (not supplied) is to be installed
in an easily accessible position for later
service. Determine the location of each
of the components, taking into account
the tube lengths and space available.
Refer to Diagrams 1 & 2.
2. Mount Backflow Prevention/
Pressure Regulator Valves
5. Install Chiller Module
Connect all plastic tubing as shown.
Refer to Diagram 4. All connections are
made using push-fit connectors. Trim tubes
to correct lengths. Tubes should be cleanly
cut square using a sharp knife or plastic
tube cutter. Ensure that tube ends are round
and not flattened or kinked, then push into
connectors firmly until properly seated (to
release, press the outer ring in while pulling
gently on the tube).
6. Install Drain Connection
The Billi dispenser tap incorporates an
air break above the spill level of the sink
and therefore a tundish is not required.
Connect a 3/8" drain tube to dishwasher
nipple, or alternativedrainage point, using
fittings supplied.
ENSURE DRAIN TUBE HAS A CONTINUAL FALL.
7. Turn on Water Supply
Pull dispenser tap lever and then turn on
water supply. After water flows from outlet,
release lever and ensure that there are no leaks.
Pull lever again and run for at least 5 minutes.
8. Turn on Electricity Supply
9. Set Chilled Water Temperature
Set the desired water temperature using
temperature control knob. Refer to Billi
B-3000 User Guide.
10. Re-check Connections for Leaks
11. Explain Operation to User
Diagram 3
22mm
Hole
Flexible
braided
hose
1/4" Blue tube
6mm Black
1/2" Stop tap
(installed by plumber)
Power cord
10mm Black
Adaptor
Fitting
To drainage point
e.g. Dishwasher nipple
Diagram 4
Locking
bush
Locking
nut
F
it certified pressure limiting valve with
dual internal check valve for backflow
prevention (supplied) to stop tap, in
accordance with enclosed
manufacturer’s instructions.
3. F
lush Lines
It is important to flush lines before fitting.
Install outlet fitting to combined valve.
Refer to Diagram 4.
4. Install Dispenser Tap Assembly
DISPENSER MUST NOT BE INSTALLED
BELOW THE SPILL LEVEL OF THE
RECEIVING FIXTURE.
A 22mm hole
is required either in the
benchtop or flat surface of sink adjacent
to bowl of sink. Mount the dispenser tap.
Refer to Diagram 3.

For continued safety of this appliance
it must be installed, operated and
maintained in accordance with the
manufacturer’s instructions.
— Your appliance should be installed by
a suitably qualified tradesperson.
— For correct operation of this appliance
it is essential to observe the instructions
as outlined in this booklet.
— Filter replacement must be performed
at intervals of not more than 6 months.
— Use this appliance only as directed
in these instructions and only for its
designed purpose.
— This appliance is not intended for use
by persons (including children) with
reduced physical, sensory or mental
capabilities, or lack of experience and
knowledge, unless they have been given
supervision or instruction concerning
use of the appliance by a person
responsible for their safety.
— Children should be supervised to ensure
that they do not play with the appliance.
— DANGER: The operation of the thermal
cut-out indicates a possibly dangerous
situation. Do not reset the thermal cut-out
until the water heater has been serviced by
a qualified person.
— WARNING: Do not connect any restrictor
or pressure relief device to the vent pipe
of this water heater if installed.
— If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent or similarly qualified persons in
order to avoid a hazard.
— New hose-sets supplied with the appliance
are to be used and old hose-sets should not
be re-used.
WARNINGS.
Billi Australi
a Pty Ltd
42 Luckno
w Crescent, Thomastown
Victoria 3074 Australia
Telephone 1800 812 321
www.billi.com.au
Designed and manufactured in Australia.
As Billi Australia Pty Ltd has a policy of
continual improvement, all details are
subject to change without notice. All
goods are sold subject to our published
terms and conditions. Billi is a registered
trademark. 613200-05
If any problems or difficulties arise contact Billi Australia Pty Ltd: Phone 1800 812 321 (Free call).
To validate your warranty online at www.billi.com.au.
For information on our filtration and service contracts please contact Billi Customer Service on
1800 812 321 or [email protected].
Scan the QR Code to access the Support page
and Shop online.