info@ vikiohome.com / www.vikiohome.com
Available Sizes: 30 36



•
• fi fi
fi
•
•
•
• fl fi
•
•
•
• fi
•
• fl
IMPORTANT SAFETY INSTRUCTIONS
2

•
IMPORTANT SAFETY INSTRUCTIONS
•
•
•
•
•
•
•
•
•
fl
•
•
3

4

5

Putty
Knife
Pencil
Tape
Measure
Phillips
Screwdriver
Aluminum Tape
Power
Drill
UtilityKnife
Drywall Knife
To calculate the length of the duct system you require, subtract the equivalent feet
for each “Duct piece” (Table Below) used in the system from the “Recommended
maximum run” (Table Below). The
transition, etc.) installed in
your duct run will determine the maximum length the duct run can be. Please refer
to the example below:
Duct Run Calculation:
Recommended maximum run
6” round duct
Duct piece deduction
Each round to rectangle transition
used
Side wall cap with damper
Roof cap
Duct Run Calcuation example:
used:
30ft
used.
The above duct pieces used are
equivalent to 30ft of a straight duct
run. Subtract 30ft from the
the longest that the straight ducting
(in addition to the vent pieces) can be.
CALCULATING VENT SYSTEM LENGTH
REQUIRED TOOLS
Level
6

7

NOTE:
Where necessary, additional screws will be needed for installation and added
support, but is not included. Please review contents before installation.
RB11-PARTS SUPPLIED
QTY: 1 PCS
Anchor Screw
(M4x
mm)
8

NOTE:
Where necessary, additional screws will be needed for installation and added
support, but is not included. Please review contents before installation.
RB12-PARTS SUPPLIED
QTY: 1 PCS
Anchor Screw
(M4x
mm)
9

TOP VIEW
DIMENSIONS
FRONT VIEW
SIDE VIEW
10

Advanced Preparations:
• Be familiar with the controls of the range hood by reading through Range
Hood
Operations.
•
standard outlet (please refer the product label for the suitable voltage
of this unit) and turn on the range hood. Verify all operations of the range hood
by referring to Range Hood
verify the existence of all supplied parts.
• Carefully remove the white or blue plastic protective coat from the range hood.
Preparations:
NOTE: To avoid damage to your hood, prevent debris from entering
the vent opening.
•
Disconnect power cord, remove the stainless steel bafe flter and grease tunnel.
•
Vikio will not be responsible for additional labour costs related to
reinstallation of the hood due to transportation internal damage or wiring issues.
(a)
(b)
(c)
the manual. Areducer will reduce the CFM of the hood and increase the noise.
c.
Use a smooth elbow to guide the air outdoors.
a.
b. DO NOT use REDUCERS. Keep the size of the duct the same, as per
11

ROUGH-IN
center line
Max: 30”
Min: 24”
Optimal: 28”
Preferred areas to
install wall or roof
vent ducting
Allow spacing for
wood blocking
to bottom panel
Wall or roof vent
may be installed
in these areas but
not recommended
Cabinet surround should
accommodate the bottom
lip of the range hood
120v Outlet can
be located here
Side Cabinet Side Cabinet
Cooking Surface
Ceiling
on accidentally.
12

13

INSTALLATION (Continued)
SAFETY WARNING: Risk of electrical shock. This range hood must be properly
grounded. Make sure this is done by qualifed electrician in accordance with all
applicable national and local electrical codes. Before connecting wires, switch
power of at service panel and lock service panel to preduct power from being
switched on accidentally.
(3) Carefully insert and slide the range
(4)
hood in the overhead cabinet.
6
Cut out hole on
the top panel of
cabinet, and in
ceiling for
6”
6
6
Cut out hole
in wall to
accommodate
elbow duct.
- Ø Transition
- Ø Elbow Duct
- Ø Duct
exhaust duct
- Ø Transition
W
ALL VENT
ROOF VENT
Use 6" round steel pipe to connect the
exhaust on the hood to the duct work above.
Use aluminum tape to make all joints secure
(3) Distance from wall to transition
circumference edge for 6".
and air tight.
14

15

Retractable Tabs
BOTTOM VIEW
SIDE VIEW
you lift the lever for the retractable tabs to
tab inserts toward
the aft slot of the
range hood opening.
INSTALLATION OF FILTERS
T
Lift Lever
***Before installing, remove
***
16

VENTING METHODS
Backdraft Damper
Wrap insulation
required for
cold climates
Minimum
6” Ø Duct
Wall
Vent
Roof
Vent
36”
typical
Min: 24” Max: 30”
17
½”
*Min height: 77 ½”
f
rom bottom of duct
to ground when range
height to stove is 24”
Min height: 83 ½”
from bottom of duct
to ground when range
height to stove is 30”
•
This range hood is factory set for venting through the roof or wall.
•
IMPORTANT:
• NEVER exhaust air or terminate
walls, crawl
spaces, ceiling, attics or garages. All exhaust must be vented to the outside.
•
only.
•
Fasten all connections with sheet metal screws and tape all
Tape.
•
wall or roof opening around the cap.
• Colder climates require wrapping insulation around the ducts and optional blowers.
Motor
•
The system must have a
17

18

RB11-EXPLOSION DAGRAM
No. Description
Quantity
1
2
3
Rubber Gasket
4
5
6
7
8
Circuit Board
9
6" Round Duct Connector
Hood Body
Control Panel
Light
10
11
12
13
14
Spuirrel Cage
Fan Blade
Motor
15
Protective Panel
16
Capacaitor
1
Plastic box
1
1
1
1
1
1
1
2
2(30") / 3(36")
1
1
1
1
Protective Grill
1
Power Cord
Filter
19

No. Description
Quantity
1
2
3
Rubber Gasket
4
5
6
7
8
Circuit Board
9
6" Round Duct Connector
Hood Body
Control Panel
Light
10
11
12
13
14
Spuirrel Cage
Fan Blade
Motor
15
Protective Panel
16
Capacaitor
1
Plastic box
1
1
1
1
1
1
1
2
2(30") / 3(36")
1
1
1
1
Protective Grill
1
Power Cord
Stainless Steel Baffle Filter
RB12-EXPLOSION DAGRAM
20

21

•
22

CONTROL PANEL REPLACEMENT
Replacing Control Panel:
3. Remove the screws on the LED Light panel.
5. Fix the screws holding the control panel.
Fix the screws of LED Light panel.
WIRING DIAGRAM (Digital Panel)
Never work on or clean the range hood while the power is on.
W
ARNING
Always unplug the unit or switch the electrical breaker to the off position.
Plug to Outlet
Black 110V
White 110V
L
N
Yellow
Capacitor
M
L
N
(F )
(F )
( F )
LIGHTS
(RB11)-Scan for a button panel
installation tutorial video.
(RB12)-Scan for a button panel
installation tutorial video.
23

Circuit Board
WARNING
Never work on or clean the range hood while the power is on.
Always unplug the unit or switch the electrical breaker to the
off position.
24

Replacing LED 3W Light Fixture:
RB11-BULB REPLACEMENT
Scan for a light bulb
installation tutorial video.
25

RB12-BULB REPLACEMENT
Replacing LED 3W Light Fixture:
Scan for a light bulb
installation tutorial video.
.
Turn the light to the left and it will loosen.
Take a new LED light, the light leg is aligned with the
hole on the lamp holder, and then turn to the right,
and the replacement is completed.
26

WARNING
Never work on or clean the range hood while the power is on.
Always unplug the unit or switch the electrical breaker to the
off position.
27

1
General Safety
TO OBTAIN SERVICE UNDER WARRANTY:
You must present proof of original purchase date.
WARRANTY
Year Parts Warranty:
For year from the date of original purchase, Vikio Range Hoods will provide free of
materials.
Replacement parts or products will be provided by Vikio Range Hoods on an exchange basis,
and will be either new or refurbished to be functionally equivalent to new.
This Warranty Will Be Voided When:
Product is damaged through negligence, improper installation, accident, abuse, misuse,
follow installation
instructions. When product is used commercially or other than its intended purpose. Damaged
because of improper connection with equipment of other manufacturers.
Who is Covered:
This warranty is extended to the original purchaser for products purchased for ordinary
home use.
What is Not Covered:
and
wear due to improper maintenance, use of corrosive and abrasive cleaning products,
acts of God. The
manufacturer and/or distributor/reseller is not liable for, and does not cover under warranty, any
loss of properties or any costs associated with removing
, servicing, installing, or determining
the source of problems with this product.
applies only to the original purchaser and does not extend to subsequent owners of this product.
Any applicable implied warranties, including the warranty of merchantability, are limited in
duration to a period of express warranty as provided herein beginning with the date of original
purchase and, no warranties, whether expressed or implied, shall apply to this product thereafter.
of
Vikio Range Hood’s policies prior to contacting us. Typically, you must include product
problem you are experiencing. You must also include proof of the date of original purchase as
evidence that the product is within the applicable warranty period, and that it isagenuine range
hood from Vikio Range Hoods.
kio
28

2
info@ vikiohome.com www.vikiohome.com
29

2
General Safety
30




info@ vikiohome.com
www.vikiohome.com