TABLE OF CONTENTS
General Information ..................................................... 2
Safety Instructions ....................................................... 2
Installation ................................................................... 3
Operation .....................................................................4
Maintenance ................................................................ 5
Repair .......................................................................... 5
Troubleshooting ........................................................... 9
Illustrated Parts List ................................................... 10
Specications ............................................................ 11
Parts and Service ...................................................... 11
Great Plains Industries, Inc. is a member of
the Petroleum Equipment Institute.
SAVE THESE INSTRUCTIONS
08/16
To the owner...
Congratulations on receiving your GPI fuel pump. We
are pleased to provide you with a system designed to
give you maximum reliability and efciency.
Your fuel pump is designed, tested, and approved for use
with gasoline (up to 15% alcohol blends such as E15),
diesel fuel (up to 20% biodiesel blends such as B20) and
kerosene. Please take all due precautions when handling
these ammable liquids. Your safety is important to us.
Also, to assure the longest possible service life, it is
important that you follow the operation and maintenance
procedures outlined in this manual. We are proud to
provide you with a quality product and dedicated
support. Together with your conscientious use, we are
sure that you will obtain years of safe, dependable service.
President
Great Plains Industries, Inc.
M-1115S Series Fuel Pump
Owner’s Manual
STOP
DO NOT RETURN THIS
PRODUCT TO THE STORE!
Please contact GPI before returning
any product. If you are missing
parts or experience problems with
your installation, our Customer
Support Department will be happy
to assist you.
GPI Customer Support
800-835-0113 or
316-686-7361
background
2
921487-09E
Important Information
To ensure safe operation, all fuel transfer systems must
be properly grounded.
Proper grounding means a continuous metal-to-metal
contact from one component to the next, including tank,
bung, pump, meter, lter, hose and nozzle.
Care should be taken to ensure proper grounding
during initial installation and after any service or repair
procedures.
All factory-supplied accessories and components assure
proper grounding.
Here is a list of major warnings and cautions that are
given throughout this manual. Please take a moment to
review them now for your future safety.
1. To prevent physical injury, observe precautions
against re or explosion when dispensing fuel. Do
not operate the system in the presence of any source
of ignition including running or hot engines, lighted
cigarettes, or gas or electric heaters.
2. Observe precautions against electrical shock when
operating the system. Serious or fatal shock can
result from operating electrical equipment in damp
or wet locations.
3. Avoid prolonged skin contact with petroleum fuels.
Use protective goggles, gloves and aprons in case
of splashing or spills. Change saturated clothing and
wash skin promptly with soap and water.
4. This product is RAINPROOF for outdoor use. Use
this pump for gasoline (up to 15% alcohol blends
such as E15), diesel fuel (up to 20% biodiesel
blends such as B20) and kerosene. Do not use this
pump for dispensing any uids other than those for
which it was designed. To do so may damage pump
components and will void the warranty.
5. Do not leave the system running without uids. “Dry
running” can damage the pump. If the system fails
to deliver fuel after 15 to 20 seconds, turn the pump
off and refer to the Troubleshooting Section.
6. Do not pump the tank completely dry, as contaminants
from the tank bottom may enter the pump.
7. To avoid pump damage, do not run the pump for
more than 10 minutes with the nozzle closed.
8. The duty cycle of this pump is 30 minutes ON and 30
minutes OFF. Allow the pump to cool for 30 minutes.
9. Observe precautions against electrical shock when
servicing the pump. Always disconnect power before
repairing or servicing. Never apply electrical power to
the system when any of the coverplates are removed.
10. If using solvent to clean pump components or tank,
observe the solvent manufacturer’s recommendations
for safe use and disposal.
Damage Inspection
Upon receipt of your system, inspect all parts and
components. Remove protective caps and plugs, as
needed, for a thorough inspection.
If any items are damaged or missing, please contact your
dealer or distributor.
This manual will assist you in operating and maintaining
your fuel pump. It furnishes information which will help
you achieve years of dependable performance and
trouble-free operation.
Please take a few moments to read through this manual
before installing and operating your pump. If you have
problems with the pump, refer to the Maintenance and
Troubleshooting Sections.
If you need assistance, contact the dealer from whom
you received your pump. If you need further assistance,
please call the factory.
How to Use this Manual
All information in this manual applies to the 120-volt
electric gear pump with an automatic or manual nozzle.
This symbol is used throughout this manual
to call your attention to safety messages.
WARNINGS alert you to
the potential for personal
injury.
CAUTIONS call attention
to practices or procedures
which may cause damage
to your equipment.
NOTES give you information that can improve efciency
of operations.
It is your responsibility to:
• know and follow applicable national, state, and local
safety codes pertaining to installing and operating
electrical equipment for use with ammable liquids.
• know and follow all safety precautions when handling
petroleum fuels.
• ensure that all equipment operators have access to
adequate instructions concerning safe operating and
maintenance procedures.
This is a safe product, designed and manufactured to meet
the high safety standards of Underwriters Laboratories
(UL) and the Canadian Standards Association (CSA). It is
designed to safely handle fuel products and, if installed,
operated, and maintained correctly, will give years of
dependable service.
WARNING
CAUTION
GENERAL INFORMATION
SAFETY INSTRUCTIONS
background
3
921487-09E
Before installation, wrap all threaded fuel connections
with three to four turns of thread tape or a pipe thread
sealant approved for use with petroleum fuels.
Important Information
To ensure safe operation, all fuel transfer systems must
be properly grounded.
Proper grounding means a continuous metal-to-metal
contact from one component to the next, including tank,
bung, pump, meter, lter, hose, and nozzle.
Care should be taken to ensure proper grounding
during initial installation and after any service or repair
procedures.
All factory-supplied accessories and components assure
proper grounding.
Priming
This pump is designed to self-prime with dry gears. Expect
suction lift as follows:
Manual Nozzle: 5.5 feet (1.7 m) with diesel
6.7 feet (2.1 m) with gasoline
Automatic Nozzle: 4.8 feet (1.5 m) with diesel
5.8 feet (1.8 m) with gasoline
If your installation requires a greater distance from the
lowest fuel level to the pump, the pump may not prime
until the gears are coated with uid.
To coat the gears, remove the plug on the top of the
pump (as detailed in Figure 6) and pour a small quantity
of motor oil into the gear cavity. Replace the plug, turn
the pump on, and open the nozzle.
A foot valve with pressure relief will be required to
maintain prime.
Install Bung Adapter and Suction Pipe
Before installation, wrap all threaded fuel connections
with three to four turns of thread tape or a pipe thread
sealant approved for use with petroleum fuels.
1. Tighten the bung adapter snugly on the fuel tank.
2. Place the union ring gasket into the inlet tting on
the bottom of the pump.
3. Thread the suction pipe into the inlet tting and tighten
until snug.
Install Pump on Tank
1. Clean the tank interior of all dirt and foreign material.
2. Extend the suction pipe to its full length and insert
into the tank opening. (Figure 1)
The suction pipe will adjust to the length needed to
rest on the tank bottom.
NOTE: The suction pipe supplied has a variable length
of 22 to 40 inches (56 to 102 cm). If additional length
is needed, use the 15 inch (38 cm) Suction Pipe
Extension. See the Illustrated Parts List for information
on accessories.
3. Place the pump on the bung adapter and tighten the
union ring securely with a pipe wrench. Make sure
the union ring is not cross-threaded.
NOTE: To prevent pressure buildup and possible fuel leaks
through the nozzle, make sure the tank is vented.
A vent cap rated at 3 psi or less is recommended.
Install Electrical Connections
This pump is designed for use with 120-volt power. Do
not attempt installation on 12-volt, 24-volt or 230-volt
power sources.
It is important to exercise more than ordinary care with
electrical installation and maintenance. Failure to follow
these electrical connection instructions could result in
death or serious injury from shock, re or explosion.
Electrical wiring and connections must be made only by
a licensed electrician in accordance with national, state,
and local electrical codes regarding Class I, Division 1
requirements as well as NFPA Code 70 and 30. Other
codes may apply.
Install UL Listed, rigid metal conduit and code-specied
gasoline and oil-resistant wire with ground wire from the
switch box to the pump electrical box and use proper
seal offs.
Figure 1
To avoid personal injury, these instructions must
be followed.
WARNING
To avoid personal injury, make sure power is discon-
nected before removing coverplates.
WARNING
INSTALLATION
background
4
921487-09E
1. Remove the electrical coverplate. (Figure 2) Be
careful not to damage gasket.
2. Route the wiring and conduit to the pump.
3. Attach the ground wire to the pump’s green ground wire.
4. Attach wiring to pump wires.
5. Position all wires inside the pump’s electrical cavity.
6. Replace the electrical coverplate.
Install Hose and Nozzle
NOTE: If installing accessories such as owmeters
or lters, do so now, following the manufacturer’s
instructions.
1. Tighten the hose into the pump outlet.
2. Tighten the nozzle onto the opposite hose end.
3. Place the nozzle into the nozzle holder on the pump
housing. Note that the nozzle cannot be placed in
the holder unless the pump is off.
NOTE: The nozzle holder allows the pump to be locked
when the nozzle is in place.
Before Each Use
Check for leaks around seals or connections. If found,
refer to the Troubleshooting Section. Make sure hoses
are in good condition and connections are tight. Make
sure the work area is dry.
Make sure the tank contains enough fuel.
Check for obvious signs of fuel contamination such as
a loose or missing tank lid which could allow debris into
the tank.
Dispense Fuel
1. To turn the pump on, remove the nozzle from its
holder and push the switch lever up.
NOTE: The nozzle holder and switch are designed so the
pump cannot operate with the nozzle in the holder.
2. Insert the nozzle into the receiving tank or container.
Squeeze the handle to start fuel ow.
This pump is designed to self-prime. If it does not begin
to deliver fuel within 15 to 20 seconds after turning the
pump on and opening the nozzle, turn off and refer to
the Priming and Troubleshooting Sections.
An automatic bypass valve prevents pressure buildup
when the pump is on with the nozzle closed.
Figure 2
To avoid personal injury, the pump must be properly
grounded.
WARNING
To prevent physical injury, observe precautions
against re or explosion when dispensing fuel. Do
not operate the system in the presence of any source
of ignition including running or hot engines, lighted
cigarettes, or gas or electric heaters.
WARNING
WARNING
Avoid prolonged skin contact with petroleum fuels.
Use protective goggles, gloves, and aprons in case
of splashing or spills. Change saturated clothing and
wash skin promptly with soap and water.
CAUTION
This pump is designed for use only with gasoline,
kerosene, and diesel fuel. Do not use this pump for
dispensing any uids other than those for which it
was designed. To do so may damage pump compo-
nents and will void the warranty.
CAUTION
Do not leave the system running without uids. “Dry
running” can damage the pump. If the pump fails
to deliver fuel after 15 to 20 seconds, turn OFF and
refer to the Troubleshooting Section.
CAUTION
Do not pump the tank completely dry, as contami-
nants from the tank bottom may enter the pump.
OPERATION
WARNING
Observe precautions against electrical shock when
operating the system. Serious or fatal shock can
result from operating electrical equipment in damp
or wet locations.
WARNING
Inspect external pump wiring regularly to ensure it
is correctly installed and shows no signs of wear.
background
5
921487-09E
Do not overll the tank. Repeated attempts to “top off” the
tank with an automatic nozzle may result in overlling.
3. After dispensing fuel, release the nozzle handle, turn
the pump off, and return the nozzle to its holder.
Auxiliary Temperature-Limiting Device
The motor is provided with an internal auxiliary
temperature-limiting device. Excessive motor heat can
trip the device. It resets automatically after the motor has
cooled approximately 30 minutes.
MAINTENANCE
This pump is designed for minimum maintenance. Motor
bearings are sealed and require no lubrication. Inspect
the pump and components regularly for fuel leaks and
make sure the hose and power cord are in good condition.
Keep the pump exterior clean to help identify leaks.
Perform a regular visual inspection of the system using
the Before Each Use procedure in the Operation Section.
Do not use this pump to pump water, chemicals, or
herbicides. Dispensing any uid other than gasoline,
diesel fuel or kerosene will damage the pump. Use of
the pump with unauthorized uids will void the warranty.
Remove and clean the fuel strainer after every 40 hours
of operation or if low ow is noticed. Refer to the Repair
Section for Strainer Cleaning instructions.
The pump may not deliver uid if an air lock occurs due
to an external lter, meter, or an off-the-shelf automatic
nozzle. To correct, remove the pipe plug in the top outlet
port and ll the gear cavity and meter with fuel. Use of
a factory-supplied automatic nozzle is recommended.
REPAIR
When disassembling, carefully inspect all parts for wear
or damage. Replace components, as necessary. The
Illustrated Parts List gives information on replacement
parts and kits.
Important Information
To ensure safe operation, all fuel transfer systems must
be properly grounded.
Proper grounding means a continuous metal-to-metal
contact from one component to the next, including tank,
bung, pump, meter, lter, hose and nozzle.
Care should be taken to ensure proper grounding
during initial installation and after any service or repair
procedures.
All factory-supplied accessories and components assure
proper grounding.
WARNING
Observe precautions against electrical shock when
servicing the pump. Always disconnect power before
repairing or servicing. Never apply electrical power to
the system when any of the coverplates are removed.
Avoid prolonged skin contact with petroleum fuels.
Use protective goggles, gloves, and aprons in case
of splashing or spills. Change saturated clothing and
wash skin promptly with soap and water.
WARNING
Remove Pump from Tank
1. Turn the pump off and disconnect from power.
2. Turn the union ring counterclockwise to release the
inlet tting.
3. Lift the pump and suction pipe from the bung adapter.
4. Elevate the nozzle and hose to allow excess fuel to
drain into the tank.
5. Wipe the entire system with a clean cloth.
Service O-Rings
A Wet Seal Kit contains all seals for your pump and should
be on hand when performing repairs. Old seals may then
be replaced with new ones as seals are accessible.
In general, when inspecting O-rings, look for breaks, wear,
and signs of deterioration, such as swelling. Replace, as
necessary. Before seating, coat O-rings with light grease.
CAUTION
To avoid pump damage, do not run the pump for
more than 10 minutes with the nozzle closed.
CAUTION
The duty cycle of this pump is 30 minutes ON and 30
minutes OFF. Allow to cool for 30 minutes.
background
6
921487-09E
Clean or Replace Strainer
Clean the inlet strainer after every 40 hours of operation
or if low ow occurs.
1. Turn the pump off and disconnect from power.
2. Remove the strainer coverplate.
3. Remove the inlet strainer and inspect for damage or
clogs. (Figure 3)
4. Clean the strainer with a soft-bristled brush and
solvent. If the strainer is very dirty, compressed air
may be used. If damaged, replace the strainer.
NOTE: A very dirty strainer can indicate a contaminated
fuel tank. Clean the tank, as necessary.
5. Clean the coverplate and O-ring. Coat the O-ring
lightly with grease.
6. Place the strainer in the cavity.
7. Ensure the coverplate O-ring is properly seated and
tighten the strainer coverplate.
Replace Gears and Drive Key
1. Turn the pump off and disconnect from power.
2. Remove the gear coverplate. (Figure 4)
4. Inspect the gears and key for wear and damage.
Replace, as necessary.
5. Wipe the gear cavity with a clean cloth.
6. Replace the gears. Make sure they turn freely.
7. Replace the drive key.
8. Make sure the gear coverplate O-ring is securely in
place. Tighten the coverplate to the housing.
Clean or Replace Bypass Poppet
1. Turn the pump off and disconnect from power.
2. Using a drive ratchet or extension, remove the pipe
plug from the top outlet port. (Figure 6)
3. Remove the gear coverplate and O-ring from the
pump housing.
4. Lift the drive key and two gears from the pump.
5. To clean the bypass poppet:
a. With a clean cloth, wipe the poppet cavity through
the top outlet port.
b. Push down on the poppet until the poppet O-ring
is exposed inside the housing. (Figure 7)
c. Using a clean cloth, rotate the poppet and clean
it thoroughly.
Figure 4
Figure 5
Figure 6
Figure 7
Figure 3
If using solvent to clean pump components or tank,
observe the solvent manufacturer’s recommenda-
tions for safe use and disposal.
WARNING
3. Lift the drive key and gears from the pump. (Figure 5)
background
7
921487-09E
Figure 9
Figure 10
Figure 11
Figure 12
6. To remove or replace the bypass poppet:
a. As above, push down on the poppet until the
O-ring is exposed.
b. Remove the O-ring with a small screwdriver or
similar tool. Take care not to damage the poppet
or O-ring. (Figure 8)
c. From inside the housing, use a small screwdriver
to push the poppet and spring through the top
outlet port. (Figure 9)
3. Inspect the wiring connections and cavity. (Figure 11)
NOTE: If permanent wiring is damaged or corroded,
the pump must be returned to the factory for wire
replacement.
4. Assemble again. Make sure the O-ring is in place
and the coverplate is tightened securely.
Replace Switch
1. Turn pump off and disconnect from power.
2. Remove the switch coverplate from the pump housing.
(Figure 12)
3. Remove the torx head screw on the switch assembly,
then remove the switch.
4. Remove wire terminals from switch.
5. Loosen the hex nut on the switch mounting plate and
remove the defective switch.
6. Reinstall the new switch by reversing the above
procedure. There are no polarity requirements. Guide
the switch into the housing cavity, pushing black wires
in before the switch. Use the housing slot to hold the
switch into place.
7. Wires must clear the coverplate and must not be
pinched. Make sure the O-Ring is properly seated
before tightening the switch coverplate.
Figure 8
O-ring Groove
➤
Poppet O-ring
➤
Spring
➤
d. Wipe the poppet and gear cavities with a clean
cloth.
e. Replace the poppet, O-ring and spring, as
necessary.
NOTE: Replace O-ring if damaged, swollen or loose-tting.
7. To assemble, place the spring and poppet into the
poppet cavity through the top outlet port. Compress
the poppet into the housing. Coat the O-ring lightly
with grease and slip over the poppet head. Make
sure the O-ring is well seated.
8. Push on the poppet through the top outlet port to
make sure it moves freely.
9. Install the pipe plug again, using sealant as necessary.
10. Replace the gears and drive key. Make sure gears
turn freely with the key removed.
11. Make sure the gear coverplate O-ring is in place.
Tighten the coverplate to the pump housing.
Service Motor Wiring
1. Turn the pump off and disconnect from power.
2. Remove the electrical coverplate from the pump
housing. (Figure 10) Evaluate condition of gasket.
Replace as needed.
background
8
921487-09E
Figure 13
Back of Pump
Replace Switch Lever or
Switch Lever Shaft O-Ring
1. Turn off the pump and disconnect from power.
2. Remove the switch coverplate from the pump housing.
3. Remove the screw connecting the switch cam to the
coverplate.
4. Remove the cam and switch lever.
5. Replace the switch lever or switch lever shaft O-Ring
as needed.
NOTE: In order to preserve the UL Listing or
CSA Certication for pump safety, return the
entire pump to the factory for motor repair or
replacement. For products serviced outside the
factory, the UL and CSA nameplates must be defaced
to indicate the equipment may no longer meet the
requirements for UL Listing or CSA Certication. This
does not apply to products serviced outside the factory
under the UL program for Rebuilt Motors for Use in
Hazardous Locations and the CSA rebuild program.
Replace Motor Shaft Seal
1. Turn the pump off and disconnect from power.
2. Remove the gear coverplate, gears, and drive key as
described in Gear Replacement instructions above.
3. Remove the motor from the pump housing.
4. Remove the motor shaft seal by prying out with a
small screwdriver. (Figure 13)
5. Lubricate the gear shaft with WD-40
®
or a similar
penetrating oil.
6. Press a new motor shaft seal evenly in the pump
housing until seated. Lubricate the seal with a
lightweight motor oil.
7. Gently slide the shaft through the seal until the motor
is ush against the pump housing.
8. Tighten the motor to the pump housing. Check for
proper installation by working a .003 feeler gauge
around the motor ange. The gauge shall not t
between the ange and the housing.
9. Install the gears and drive key as described in Gear
Replacement instructions above.
background
9
921487-09E
SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION
A. MOTOR DOES 1. Auxiliary temperature-limiting Turn pump switch off. Allow motor to cool approximately 30 minutes. Device
NOT RUN device tripped resets automatically. Try again.
2. Switch defective Remove switch coverplate and inspect switch. Replace, if necessary.
3. Motor burned out Replace motor as described in the Repair Section.
B. MOTOR RUNS BUT 1. Drive key broken Remove gear coverplate and replace drive key. Make sure gears turn freely
DOES NOT PUMP
FLUID with the key removed.
2. Suction pipe clogged, damaged, or Remove pump from tank. Inspect suction pipe. Clean or replace, as
missing necessary.
3. Gear coverplate or O-ring damaged Remove and inspect the coverplate and O-ring. Replace, as necessary.
Refer to the Repair Section on Servicing O-rings.
4. Strainer clogged or defective Remove strainer coverplate. Remove and clean strainer. Install again.
5. Bypass poppet O-ring worn or Inspect the O-ring, using instructions in the Repair Section. Replace, if necessary.
missing
6. Bypass poppet O-ring dirty Remove poppet assembly and clean poppet and cavity.
7. System air leak Tighten all pump ttings and connections. Inspect suction pipe for leaks or damage.
8. System air lock This can occur if external lter, meters, or an off-the-shelf automatic nozzle
is being used. To correct, remove the pipe plug in the top outlet port and ll the
gear cavity with fuel. Use of a factory-supplied automatic nozzle is recommended.
9. Poor connections or low voltage Make sure electrical connections are secure. Check power source.
10. Fuel level low Fill tank.
11. Bypass poppet binding or damaged Remove the bypass poppet, spring, and O-ring. Clean cavity. Inspect and
replace components, as necessary.
C. LOW FLOWRATE 1. Poor connections or low voltage Make sure electrical connections are secure. Also check power source.
2. Strainer partially clogged Remove the strainer coverplate. Remove and clean the strainer. Install again.
3. Suction pipe clogged or damaged Remove pump from tank. Inspect suction pipe. Clean or replace, as
necessary.
4. Fuel tank empty Fill tank.
5. Using off-the-shelf automatic nozzle Factory-supplied automatic nozzle is recommended.
6. System air leak Tighten all pump ttings and connections. Inspect suction pipe for leaks or
damage. Replace, as necessary.
7. Suction pipe too close to tank bottom Suction pipe must have at least 1/4 in. (0.6 cm) clearance from bottom of the tank.
8. Bypass poppet spring weak Remove the bypass poppet and inspect spring. Replace, if necessary.
9. Discharge hose too long Long hoses reduce ow rate. Shorten hose.
D. MOTOR STALLS
WHEN OPERATING
IN BYPASS MODE 1. Running too long in bypass mode Limit bypass operation to 10 minutes.
2. Gears worn Remove gear coverplate and inspect gears and drive key. Make sure gears
turn freely with the key removed. Replace, if worn.
3. Wiring defective Use Wiring instructions in the Installation Section to ensure proper
connections.
4. Bypass poppet binding or damaged Remove the bypass poppet, spring, and O-ring. Clean cavity. Inspect
components and replace, as necessary.
5. Motor defective Replace motor as described in the Repair Section.
E. RAPID OVERHEAT- 1. Duty cycle too long Pump operation should not exceed the standard duty cycle of 30 minutes ON,
OF MOTOR and 30 minutes OFF. Allow the pump to cool for 30 minutes.
2. Strainer clogged Remove strainer coverplate. Remove and clean strainer. Install again.
3. Suction pipe clogged or damaged Remove pump from tank. Inspect suction pipe. Clean or replace, as
necessary.
4. Gears worn Remove gear coverplate and inspect gears and drive key. Make sure gears
turn freely with key removed. Replace, if necessary.
5. Fuel level low Fill tank.
6. Running too long in bypass mode Limit bypass operation to 10 minutes.
TROUBLESHOOTING
background
10
921487-09E
Item No.
No. Part No. Description Req’d.
2 904002-23 Sems Screw, 1/4-20 x 3/4 in. ....................... 9
3 119008-551 Motor, 120-volt AC with Circuit Board ..........1
4 11002502 Motor Shaft Seal or (Kit or ) ............... 1
6 904001-42 Pipe Plug, 3/4 inch ....................................... 1
7 110010-1 Bypass Poppet .............................................1
8 110131-2 Bypass Poppet Spring ................................1
14 110026-1 Gear Coverplate O-ring or (Kit or ) ....1
16 110024-1 Coverplate, Strainer ..................................... 1
17 110026-4 Strainer Coverplate O-ring or (Kit or ) 1
18 110009-1 Inlet Strainer ................................................1
19 110195-02 Electrical Coverplate
............................... 1
110285-01 Electrical Cover Gasket
* ............................ 1
22 110277-506 Assembly, Switch ......................................... 1
25 110026-6 Switch Coverplate O-ring or (Kit ) ...........1
26 110276-501 Switch Coverplate Assembly .......................1
27 110032-1 Union Ring Gasket .......................................1
29 110100-1 Suction Pipe, 22 to 40 in. (56 to 102 cm) .....1
30 110187-1 Hose Assembly, 3/4 in. x 12 ft., (3.7 m) Non-UL ..1
31 110291-01 Automatic Unleaded Nozzle, 3/4 in. .............1
32 110155-21 Manual Unleaded Nozzle, 3/4 in., UL ..........1
33 11030302 Cover, Nozzle ..............................................1
34 904006-86 Screw, Tapping ............................................2
35 904002-22 Sems Screw .................................................4
36 904002-24 Sems Screw .................................................4
32
31
29
G
27
22
34
33
2
3
C
8
6
7
D
E
F
14
36
18
17
30
16
35
19
2
26
30
4
25
111501-1 Adapter Kit
906001-4 Pressure Vent Cap (3 psi)
115527-2 Suction Pipe Extension, 15 in. (38 cm)
110016-1 Inlet Fitting (not shown)
110158-1 Union Ring (not shown)
110504-1 Overhaul Kit - Wet Seal Kit plus: 2 Gears; Drive Key; O-Ring
for Switch Coverplate
110906-1 Wet Seal Kit - Motor Shaft Seal and O-Rings for: Strainer
Coverplate; Gear Coverplate; Bypass Poppet
110908-1 Bypass Poppet O-ring Kit or (Kit A or B)
110907-1 Gear Kit or (Kit A)
110913-2 Drive Key Kit
110927-04 Gear Coverplate Kit
110909-1 Bung Adapter Kit
* Evaluate condition of gasket to determine if replacement is required.
Accessories and Kits
A
A B
A B
A B
G
F
A
C
E
B
D
ILLUSTRATED PARTS LIST
background
11
921487-09E
For warranty consideration, parts, or other service
information, please contact your local distributor. If
you need further assistance, contact the GPI Customer
Service Department in Wichita, Kansas, during normal
business hours at:
Tel: 316-686-7361
Fax: 316-686-6746
To obtain prompt, efcient service, always be prepared
with the following information:
1. The model number of your pump.
2. The serial number or manufacturing date code of
your pump.
3. Part descriptions and numbers.
Part information can be obtained from the Illustrated
Parts List.
For warranty work, always be prepared with your original
sales slip or other evidence of purchase date.
Please contact GPI before returning any parts. It may
be possible to diagnose the trouble and identify needed
parts in a telephone call. GPI can also inform you of any
special requirements you will need to follow for shipping
fuel dispensing equipment.
Applications:
Fluids: Low viscosity petroleum fuels such as gasoline
(up to 15% alcohol blends such as E15), diesel
fuel (up to 20% biodiesel blends such as B20) and
kerosene.
Operating Environment: Designed for mounting on
above-ground vented petroleum storage tanks.
RAINPROOF for outdoor use.
Pump Housing:
Lightweight, corrosion-resistant, cast aluminum body.
Convenient spin collar for easy installation.
Performance:
Pump Rate:
Manual Nozzle: Up to 12 GPM (45 LPM)
Automatic Nozzle: Up to 9 GPM (30 LPM)
Duty Cycle: 30 min. ON, 30 min. OFF
Suction Lift:
Manual Nozzle: Up to 5.5 ft. (1.7 m)
Automatic Nozzle: Up to 4.8 ft. (1.5 m)
Operating Temperature:
-20° F to +125° F (-29° C to +52° C)
Operating Pressure:
15 PSI
Electrical Specications:
Input: 120-volt AC
Motor: 1400 RPM, UL Listed, CSA Certied
Mechanical Connections:
Bung: 2 in. NPT
Inlet: 1 in. NPT
Outlet: 3/4 in. NPT
Accessories:
Standard 3/4 inch x 12 ft. (3.7 m) Buna-N electrically
conductive dis charge hose
Standard 3/4 inch manual unleaded nozzle
Standard 3/4 inch automatic shutoff unleaded nozzle
Weight:
Shipping: 22 lbs. (9.9 kg) with manual nozzle
23 lbs. (10.4 kg) with automatic nozzle
CAUTION
Do not return the pump or parts without authority
from the Customer Service Department. Due to strict
government regulations, GPI cannot accept parts
unless they have been drained and cleaned.
SAVE THESE INSTRUCTIONS
SPECIFICATIONS PARTS AND SERVICE
background
921487-09E08/16
Limited Warranty Policy
Great Plains Industries, Inc. 5252 E. 36
th
Street North, Wichita, KS USA 67220-3205, hereby provides a limited warranty against
defects in material and workmanship on all products manufactured by Great Plains Industries, Inc. This product includes a 2 year
warranty from date of purchase as evidenced by the original sales receipt. A 30 month warranty from product date of manufacture
will apply in cases where the original sales receipt is not available. Reference product labeling for the warranty expiration date
based on 30 months from date of manufacture. Manufacturer’s sole obligation under the foregoing warranties will be limited to
either, at Manufacturer’s option, replacing or repairing defective Goods (subject to limitations hereinafter provided) or refunding the
purchase price for such Goods theretofore paid by the Buyer, and Buyer’s exclusive remedy for breach of any such warranties will
be enforcement of such obligations of Manufacturer. The warranty shall extend to the purchaser of this product and to any person
to whom such product is transferred during the warranty period.
This warranty shall not apply if:
A. the product has been altered or modied outside the warrantor’s duly appointed representative;
B. the product has been subjected to neglect, misuse, abuse or damage or has been installed or operated other than in
accordance with the manufacturer’s operating instructions.
To make a claim against this warranty, contact the GPI
®
Customer Service Department at 316-686-7361 or 800-835-0113. Or by
mail at:
Great Plains Industries, Inc.
5252 E. 36
th
St. North
Wichita, KS, USA 67220-3205
GPI will step you through a product troubleshooting process to determine appropriate corrective actions.
GREAT PLAINS INDUSTRIES, INC., EXCLUDES LIABILITY UNDER THIS WARRANTY FOR DIRECT, INDIRECT, INCIDENTAL
AND CONSEQUENTIAL DAMAGES INCURRED IN THE USE OR LOSS OF USE OF THE PRODUCT WARRANTED HEREUNDER.
The company herewith expressly disclaims any warranty of merchantability or tness for any particular purpose other than for
which it was designed.
This warranty gives you specic rights and you may also have other rights which vary from U.S. state to U.S. state.
Note: In compliance with MAGNUSON MOSS CONSUMER WARRANTY ACT – Part 702 (governs the resale availability of the
warranty terms).
© 2016 Great Plains Industries, Inc. All Rights Reserved. Made in U.S.A.
and GPI
®
are registered trademarks of Great Plains Industries, Inc.

Specifications

Indexed Terms: Fuel Transfer Pump, 12 GPM

VOLT 110000-87 Questions and Answers

Questions and Answers

Related Products