Mi-T-M Corporation
|
50 Mi-T-M Drive, Peosta, IA 52068
|
(800) 553-9053
|
www.mitm.com
Making a positive impact on
our environment for today
and future generations.
Water Treatment Systems
Pit Systems
& Accessories

Mi-T-M Corporation
|
50 Mi-T-M Drive, Peosta, IA 52068
|
(800) 553-9053
|
www.mitm.com
Pit Systems
In-Ground Fiberglass Pits
2
USE THESE PREMIUM QUALITY FIBERGLASS PIT
COMPONENTS TO CREATE A CUSTOMIZED
PRETREATMENT PIT SYSTEM FOR WASH WATER
RECYCLE OR SEWER DISCHARGE OPERATIONS.
PIT COMPONENTS ARE DESIGNED TO:
●
Effectively pre-treat wash water for treatment by an above-ground system
●
Be easily installed by your contractor
3' x 9' PIT SYSTEMS
PART NUMBER PIT SIZE (FT.) DESCRIPTION SHIP WT.
12-0074 3x9x4.5 3-stage collection pit, fiberglass, 600-gallon capacity 480 lb.
12-0223 3x9x4.5 3-foot x 9-foot baffleless pit, fiberglass, 600-gallon capacity 480 lb.
12-0238 3x9x4.5 2-stage collection pit with single baffle, fiberglass, 600-gallon capacity 480 lb.
12-0244 3x9x4.5 3-stage collection pit with middle weir and third baffle, fiberglass,
large solids settling area, 600-gallon capacity
480 lb.
20-0635A01 Fits 3x9 Above-ground external brace kit, #12-0074 250 lb.
20-1505A01 Fits 3x9 Pit liner assembly, painted; 2 qty. are required 45 lb.
56-0032 Fits 3x9 Aluminum hinged diamond plate cover with 3 frame sections 100 lb.
RC-0001-0003 Fits 3x9 Brace kit for installation of 3-stage collection pit 200 lb.
RC-0018-0001* Fits 3x9 Steel grating for pit; 3,060 lb./ft.
2
uniform load rating 546 lb.
RC-0018-0002* Fits 3x9 Steel grating for pit with steel cover; 3,060 lb./ft.
2
uniform load rating 680 lb.
*May combine RC-0018-0001 and RC-0018-0002 to have both open and closed sections for the 3' x 9' pits.
See photo on page 8. Consult factory for more information.
3' x 9' x 4.5' 3-stage
collection pit, 12-0074
2' x 2' x 3' sump
pit, 12-0073
3' x 3' x 4.5' catch
basin, 12-0071
Aluminum diamond plate
cover and frame, 56-0030
Steel grating for pit, RC-0018-0001
3' x 3' PIT SYSTEM
PART NUMBER PIT SIZE (FT.) DESCRIPTION SHIP WT.
12-0071 3x3x4.5 Catch basin, fiberglass, 100-gallon capacity 190 lb.
20-0480A01 Fits 3x3 Steel grating for pit, 2 sections; 6,250 lb./ft.
2
uniform load rating,
H-20 load rated
250 lb.
20-1533A01 Fits 3x3 Pit liner assembly, painted 26 lb.
56-0031 Fits 3x3 Aluminum diamond plate cover and frame 30 lb.
RC-0001-0002 Fits 3x3 Brace kit for installation of 3-foot x 3-foot pit 150 lb.
2' x 2' PIT SYSTEM
PART NUMBER PIT SIZE (FT.) DESCRIPTION SHIP WT.
12-0073 2x2x3 Sump pit, fiberglass, 50-gallon capacity 92 lb.
20-0479A01 Fits 2x2 Steel grating for pit; 6,660 lb./ft.
2
uniform load rating, H-20 load rated 100 lb.
56-0030 Fits 2x2 Aluminum diamond plate cover and frame 60 lb.
RC-0001-0001 Fits 2x2 Brace kit for installation of 2-foot x 2-foot pit 75 lb.

Mi-T-M Corporation
|
50 Mi-T-M Drive, Peosta, IA 52068
|
(800) 553-9053
|
www.mitm.com
Pit Systems
In-Ground Fiberglass Pits
3
Aeration stick assembly, WX-0018
Aluminum round sump pit,
56-0069 and aluminum
sump grating, 56-0070
Oil coalescing pack, 855-0013
Sediment
3' x 3' Catch Basin
Model #12-0071
3-Stage Collection Pit
Model #12-0074
2' x 2' Sump Pit
Model #12-0073
Water ready for
treatment
Aeration stick,
#WX-0018
Free floating oil
Trap and basket, 33-0661
55-2248
55-1848
55-2448
Bulkhead Fittings
ACCESSORIES:
PART NUMBER DESCRIPTION
3-0216 Submersible sump pump – Stainless-steel replacement, 1/2 HP, 230V, 1Ø, 5.0A
3-0460 Replacement sump pump – Surface-mount, 1.0 HP, 115V, 15.0A or 1.0 HP, 230V, 8.0A
33-0661 Trap and basket – Used on #3-0460 sump pump
55-1848 Bulkhead fitting – For piping of pits, 2-inch, 1 each
55-2248 Bulkhead fitting – For piping of pits, 3-inch, 1 each
55-2448 Bulkhead fitting – For piping of pits, 4-inch, 1 each
855-0013 Oil coalescing pack – For #12-0074 3-stage collection pit
OPTION:
PART NUMBER DESCRIPTION
WX-0018 Aeration stick assembly – Prevents water from stagnatizing, includes regulator assembly, for aeration of pits
ALUMINUM SUMP PIT AND GRATING:
PART NUMBER DESCRIPTION
56-0069 Aluminum round sump pit – Lightweight aluminum design; 4-inch NPT inlet; 2-inch x 2-inch NPT and 1-inch x
3
⁄4-inch NPT outlets; 52-gallon capacity
56-0070 Aluminum sump grating – Lightweight aluminum cover for #56-0069 aluminum round sump pit
3-0216
3-0460
Sump Pumps

Mi-T-M Corporation
|
50 Mi-T-M Drive, Peosta, IA 52068
|
(800) 553-9053
|
www.mitm.com
Pit Cleaner
4
THE PIT CLEANER IS THE RIGHT TOOL
TO AID IN THE CLEAN-UP OF SOLIDS IN
HARD-TO-REACH PLACES. IT IS DESIGNED
TO DRAW AND FILTER THE SOLIDS THAT
COLLECT IN WASH WATER PITS.
APPLICATIONS
●
Mud and sludge pits
●
Sand pits
●
Heavy grass clean-up
USE WITH PRESSURE WASHERS WITH 2.0-GPM UP TO 5.0-GPM WATER VOLUME
AND 1000-PSI UP TO 4000-PSI MAXIMUM OPERATING PRESSURE.
PART NUMBER DESCRIPTION DIMENSIONS (LxWxH) SHIP WT.
855-0017 Sludge box – Plastic box designed to hold the sludge bags; includes a 10-foot x 2-inch diameter PVC hose 30x20x16in. 131 lb.
RC-0002-0001 Pit cleaner assembly – Includes suction lance, suction head and flex hose; 87-inch suction lance is capable of vacuuming solids up to 1-inch
diameter, 20-foot of flexible hose is standard with the suction hose
93x12x4in. 25 lb.
RC-0003-0001 Sludge carrier – Movable cart designed to hold the sludge bags 22x29x48in. 53 lb.
RC-0003-0002 Biodegradable sludge bags – Designed to capture the sludge while allowing the water to flow through, used with either #855-0017 sludge
box or #RC-0003-0001 sludge carrier; 5 qty.
– –
Sludge carrier, RC-0003-0001
Pit cleaner assembly, RC-0002-0001
Sludge box with 10-ft.
PVC hose, 855-0017
Biodegradable sludge bags,
RC-0003-0002

Mi-T-M Corporation
|
50 Mi-T-M Drive, Peosta, IA 52068
|
(800) 553-9053
|
www.mitm.com
Sample Pit Cleaning Application
Includes In-Ground Fiberglass Pits
5
Rotating Elbow:
For convenience while
vacuuming out pits,
elbow swivels to
follow the direction
of the hose.
Pit Cleaner Assembly,
#RC-0002-0001:
The handle adjusts for the
comfort of the operator.
Portable Electric Hot
Water Pressure Washer
Model #HHS-3004-2E2G
Biodegradable
Sludge Bag,
#RC-0003-0002:
The biodegradable bag
is designed to capture
the sludge while
allowing the water
to flow through.
Suction Lance, #RC-0002-0001:
This 87-inch suction lance is capable of vacuuming
up to 1-inch diameter solids. 20-feet of flexible hose
is standard with the suction lance.
Suction Head:
Venturi-effect in the suction head causes force from the
pressure washer to suck mud from the bottom of the pit
into the biodegradable sludge bag.
Sludge Carrier,
#RC-0003-0001:
Movable cart designed to
hold the sludge bags.
RECOMMENDED PRETREATMENT
APPLICATIONS:
– Rental Yards
– Golf Courses
– Heavy Equipment Dealers
– Trucking Facilities
– Military Bases
– Truck Rental Fleets
– Diesel Repair Facilities
– Forklift Washing Operations
– Aircraft Maintenance and Restoration
– Shipyards
– Municipalities/State DOTs
– Oil Fields
– Engine Rebuilders and Manufacturers
THE IMPORTANCE OF
A PROPER PIT SYSTEM
Once equipment is washed, the untreated
wash water flows into your pit system.
A proper pit system for your application
is the first step in proper wash water
treatment and a critical element in any
wash water recycle system.
Consult your dealer to determine the pit
system configuration that works best
for your application.

Mi-T-M Corporation
|
50 Mi-T-M Drive, Peosta, IA 52068
|
(800) 553-9053
|
www.mitm.com
BPS Series
Biological Pit Enhancement System
6
THE BIOLOGICAL PIT ENHANCEMENT SYSTEM
ENABLES YOU TO INJECT MICROBES AND
NUTRIENTS INTO WATER WHERE OIL COLLECTS.
THIS WILL IMPROVE THE QUALITY OF THE
WATER STORED IN PITS.
PART NUMBER POWER REQUIREMENTS DIMENSIONS (LxWxH) SHIP WT.
BPS-120M 120V, 1Ø, 8.0A, 60Hz 30x22x39in. 150 lb.
FEATURES
●
2 aeration pumps – linear pumps used to infuse air into water collection pits
●
2 peristaltic pumps – used to inject bacteria and nutrients
●
2 aeration stick assemblies – prevents water from stagnating in pit systems
●
115V single phase setting
●
Internal timers allow end user to control the amount and frequency of the liquid
microbes and nutrient doses. The BPS Series can be set to inject bacteria every
minute, every hour or every day, whatever the situation dictates.
BPS-120M
Shown with side panel removed and liquid
microbes, AW-0058-0020, not included
Aeration stick

Mi-T-M Corporation
|
50 Mi-T-M Drive, Peosta, IA 52068
|
(800) 553-9053
|
www.mitm.com
Sample Pit Application
Includes Biological Pit Enhancement System
7
Aluminum round sump pit, 56-0069 and aluminum sump grating, 56-0070 installation
Aeration
Stick
(included)
Model #BPS-120M
3' x 3' Catch Basin
Model #12-0071
3' x 9' Collection Pit
Model #12-0074

041521
50 Mi-T-M Drive
|
Peosta, IA 52068
(800) 553-9053
|
www.mitm.com
Steel Grating Options for Pit Systems
Made in
with Globally Sourced
Components
USA
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.
Steel grating for pit, RC-0018-0001; and
steel grating for pit with steel cover, RC-0018-0002;
may be combined to have both open and closed
sections for 3' x 9' fiberglass pits
Steel grating for pit, RC-0018-0001 and steel
grating for pit with steel cover, RC-0018-0002
PART NUMBER PIT SIZE (FT.) DESCRIPTION
UNIFORM
LOAD RATING SHIP WT.
RC-0018-0001* Fits 3x9 Steel grating for pit 3,060 lb./ft.
2
546 lb.
RC-0018-0002* Fits 3.9 Steel grating for pit
with steel cover
3,060 lb./ft.
2
680 lb.
20-0480A01 Fits 3x3 Steel grating for pit,
2 sections
6,250 lb./ft.
2
,
H-20 load rated
250 lb.
20-0479A01 Fits 2x2 Steel grating for pit 6,660 lb./ft.
2
,
H-20 load rated
100 lb.
*May combine RC-0018-0001 and RC-0018-0002 to have both open and closed sections
for the 3' x 9' pits.