Tr V05-01

Product's Documents

Below are documents related to this product, you can read online or download:
User Manual Specification
  • 16 Tra104-04 Antenna Specification 2.4G Wifi - (English) Download

13 Tra104-04 Users Manual

This is the main product document for model TR V05-01. Additionally, the document applies to other Sensize models: TRA104-04

The file format is pdf, 6 pages, you can download this manual here .

background
TR V05-01 Product Specicaon and Manual
I. Product Overview
TR V05-01 is an asset tracking device designed for global supply chain management,
specically engineered for reusable transport containers (including plasc crates and pallets,
etc.). Tracker V5-PECO provides enterprises with end-to-end visible logiscs tracking
soluons, signicantly improving asset management eciency and security.
II. Product Highlights
Opmized power management system supports mulple baery types, with
theorecal lifespan of 5 years
Wi-Fi ngerprinng + BLE-assisted posioning
Record temperature data
store up to 6 months’ worth of tracking data in case of cellular network coverage
outages
Upload data by connecng over the LTE CAT1 cellular network in the North America
and third-party WiFi APs.
IP67 waterproof and dustproof, 2-meter drop protecon, and suitable for harsh
industrial environments
III. Detailed Technical Specicaons
3.1 Core Processing Unit
Item
Specicaon
Main Controller
ESP32-WROOM-32UE (supports 2.4 GHz Wi-Fi)
Firmware Compability
Exisng Sensize rmware, no redevelopment needed
3.2 Low-power Bluetooth Subsystem
Item
Specicaon
Bluetooth Chip
Renesas DA14535
Operang Mode
Primarily broadcast mode, can receive data from surrounding BLE
devices
background
Item
Specicaon
Broadcast Interval
Congurable (default 1 second, adjustable based on power
consumpon requirements)
Communicaon
Interface
UART connecon with main controller
Antenna Soluon
SR4L034-R (4G), SR4W089 (Bluetooth), Airgain N03SZAAA-T2M62-PK1-
G275U (WIFI)
3.3 Cellular Communicaon Module
Tracker V6 oers mulple regional versions to opmally meet dierent market
requirements:
Version
Applicable Region
Recommended
Module
Band
Support
North America
Edion
USA, Canada,
Mexico
Quectel EG800Q-NA
LTE CAT1
SIM Card Support:
Standard: MFF2 eSIM (5mm x 6mm, soldered, high reliability)
Oponal: Plasc SIM card holder (for R&D tesng and special scenarios)
3.4 Posioning and Environmental Monitoring
Model
Funcon Descripon
ST LIS3DHTR
Supports moon detecon, free-fall
recognion, device orientaon determinaon
Renesas ISL1208
High-precision ming, built-in watchdog
funcon, with 32KHz crystal
High-precision
thermistor
Measurement range: -20℃~+80℃
background
Model
Funcon Descripon
ESP32 integrated
Scans surrounding APs for Wi-Fi ngerprint
posioning
3.5 Storage and Data Management
Item
Specicaon
Storage
Capacity
Can store 6 months of tracking data
Data Content
Locaon informaon, mestamp, temperature data, BLE device data,
device status
3.6 Power System
Item
Pallet Tracking Edion
Baery Type
8 x AA Alkaline baeries
Baery Capacity
-
Operang Voltage
3.0V
Standby Current
<50μA
Average Operang
Current
-
Theorecal Lifespan
5 years (depends on usage frequency and environmental
temperature)
Baery Replacement
No replaceable
3.7 Operang Environment Parameters
background
Item
Parameter
Operang Temperature
-20℃ ~ +80℃
Storage Temperature
-20℃ ~ +80℃
Waterproof Rang
IP67
Drop Resistance
2-meter drop onto concrete oor
IV. Mechanical Structure and Installaon
4.1 Enclosure Structure
Dimensions: L:445mm X 30mm X 17mm
Installaon Method: Compable with standard wooden pallets, can be xed using
screws
Material: Reinforced polycarbonate, excellent impact resistance
Color: Pantone 7499 C
V. Applicaon Scenarios
5.1 Pallet Circulaon Management
Track pallet movement paths
Calculate pallet ulizaon rates
Prevent pallet loss
VI. Usage Guide
6.1 Device Acvaon
1. Check device appearance for damage, ensure SN label is clear
2. Baery pre-installed, and device automacally enters inializaon and completes
network registraon and data synchronizaon
6.2 Installaon and Fixing
Fix using screws or zip es through mounng holes of the pallet blocks
6.3 Maintenance and Care
Regularly check enclosure for damage, ensure sealing is intact
background
VII. Precauons
7.1 Baery Safety
Strictly prohibited to charge, short-circuit, heat, or disassemble baeries
Do not dispose of baeries in re to avoid explosion
Dispose of waste baeries according to local environmental regulaons
7.2 Operang Environment
Although the device is waterproof, prolonged immersion is not recommended
Avoid strong impact or compression of the device to prevent damage to internal
components
Operang temperature range -20℃~+80℃, exceeding this range may aect
performance
7.3 RF Safety
Device complies with internaonal electromagnec radiaon standards, harmless to
human body under normal use
Maintain at least 20cm distance from human body during installaon
FCC Warning
This device complies with Part 15 of the FCC Rules. Operaon is subject to the
following two condions:
(1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired
operaon.
NOTE 1: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed
to provide reasonable protecon against harmful interference in a residenal
installaon. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instrucons, may cause harmful
interference to radio communicaons. However, there is no guarantee that
interference will not occur in a parcular installaon. If this equipment does cause
harmful interference to radio or television recepon, which can be determined by
turning the equipment o and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separaon between the equipment and receiver.
background
-Connect the equipment into an outlet on a circuit dierent from that to which the
receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
NOTE 2: Any changes or modicaons to this unit not expressly approved by the
party responsible for compliance could void the user's authority to operate the
equipment.
RF Exposure Statement
To maintain compliance with FCC'S RF Exposure guidelines, This equipment should be
installed and operated with minimum 20cm between the radiator and your body.
This device and its antenna(s) must not be co-located or operaon in conjuncon
with any other antenna or transmier.

Specifications