See page 14 for instructions on assembling your generator.
See page 19 for Initial Use Instructions.
2025 Honda Motor Co., Ltd. -All Rights Reserved
C
Owner
,
s Manual

K
背幅4.6mm
QUICK REFERENCE INFORMATION
Fuel Type Regular unleaded gasoline with an
ethanol content of no more than 10%
and a pump octane rating of 86 or
higher (see page 23)
Engine Oil Type SAE 10W-30, API SJ or later (or
equivalent), for general use
(see page 20)
Spark Plug Type NGK: BPR6ES
Electrode Gap 0.028–0.031 in (0.7–0.8 mm)
Maintenance Before each use Check engine oil level.
Check air cleaner.
Check GFCI operation.
First 20 hours Change engine oil.
Subsequent See "MAINTENANCE SCHEDULE"
(see page 75)
Keep this owner’s manual handy so that you can refer to it any time.
This owner’s manual is considered a permanent part of the generator and
should remain with the generator if resold.
The information and specications included in this publication were in eect at
the time of approval for printing. Honda Motor Co., Ltd. reserves the right,
however, to discontinue or change specications or design at any time without
notice and without incurring any obligation whatsoever.
The illustration may vary according to the type.
The engine exhaust from this product contains
chemicals known to the State of California to
cause cancer, birth defects or other
reproductive harm.
Exhaust contains poisonous carbon
monoxide gas that can build up to
dangerous levels in enclosed or partly
enclosed areas.
Breathing carbon monoxide can cause
unconsciousness or death.
Never run this product's engine in an
enclosed, or even partly enclosed area.

K
背幅4.6mm
QUICK REFERENCE INFORMATION
Fuel Type Regular unleaded gasoline with an
ethanol content of no more than 10%
and a pump octane rating of 86 or
higher (see page 23)
Engine Oil Type SAE 10W-30, API SJ or later (or
equivalent), for general use
(see page 20)
Spark Plug Type NGK: BPR6ES
Electrode Gap 0.028–0.031 in (0.7–0.8 mm)
Maintenance Before each use Check engine oil level.
Check air cleaner.
Check GFCI operation.
First 20 hours Change engine oil.
Subsequent See "MAINTENANCE SCHEDULE"
(see page 75)
Keep this owner’s manual handy so that you can refer to it any time.
This owner’s manual is considered a permanent part of the generator and
should remain with the generator if resold.
The information and specications included in this publication were in eect at
the time of approval for printing. Honda Motor Co., Ltd. reserves the right,
however, to discontinue or change specications or design at any time without
notice and without incurring any obligation whatsoever.
The illustration may vary according to the type.
The engine exhaust from this product contains
chemicals known to the State of California to
cause cancer, birth defects or other
reproductive harm.
Exhaust contains poisonous carbon
monoxide gas that can build up to
dangerous levels in enclosed or partly
enclosed areas.
Breathing carbon monoxide can cause
unconsciousness or death.
Never run this product's engine in an
enclosed, or even partly enclosed area.

1
INTRODUCTION
Thank you for purchasing a Honda generator.
We would like to help you get the best results from your new generator and to
operate it safely. This manual contains the information on how to do that; please
read it carefully.
We suggest you read the "Distributor’s Limited Warranty" (see page 109) to fully
understand its coverage and your responsibilities of ownership.
When your generator needs scheduled maintenance, keep in mind that your
Honda servicing dealer is specially trained in servicing Honda generators and is
supported by the parts and service divisions of American Honda. Your Honda
servicing dealer is dedicated to your satisfaction and will be pleased to answer
your questions and concerns.
31Z376290-A.book 1 ページ 2025年10月24日 金曜日 午後2時44分

2
INTRODUCTION
A FEW WORDS ABOUT SAFETY
Your safety and the safety of others are very important.
We have provided important safety messages in this manual and on the
generator. This information alerts you to potential hazards that could hurt you
or others. Please read these messages carefully.
Of course, it is not practical or possible to warn you about all the hazards
associated with operating or maintaining a generator. You must use your own
good judgment.
You will find important safety information in a variety of forms:
• Safety Labels — on the generator.
• Instructions — how to use this generator correctly and safely.
• Safety Headings — such as IMPORTANT SAFETY INFORMATION.
• Safety Messages — preceded by a safety alert symbol and one of three
signal words, DANGER, WARNING, or CAUTION.
These signal words mean:
This entire book is filled with important safety information - please read it
carefully.
DAMAGE PREVENTION MESSAGES
In addition to the above, you will find information preceded by a symbol.
That information is intended to help you avoid damage to your generator, other
property, or the environment.
You WILL be KILLED or SERIOUSLY HURT if you do
not follow instructions.
You CAN be KILLED or SERIOUSLY HURT if you do
not follow instructions.
You CAN be HURT if you do not follow instructions.
31Z376290-A.book 2 ページ 2025年10月24日 金曜日 午後2時44分

3
CONTENTS
INTRODUCTION ................................................................................................ 1
GENERATOR SAFETY ........................................................................................ 7
IMPORTANT SAFETY INFORMATION................................................................................7
Operator Responsibility...................................................................................................7
Carbon Monoxide Hazards.............................................................................................8
Electric Shock Hazards .....................................................................................................9
Fire and Burn Hazards ......................................................................................................9
Refuel With Care...............................................................................................................10
Vehicles and Transportation Hazards.......................................................................10
SAFETY LABEL LOCATIONS................................................................................................11
ASSEMBLY....................................................................................................... 14
SAFETY......................................................................................................................................14
The Importance of Proper Assembly........................................................................14
ASSEMBLY................................................................................................................................15
Unpacking ..........................................................................................................................15
Loose Parts .........................................................................................................................15
Wheel Kit Installation......................................................................................................16
Battery..................................................................................................................................17
INITIAL USE INSTRUCTIONS........................................................................... 19
ENGINE OIL..............................................................................................................................19
ENGINE OIL RECOMMENDATIONS..................................................................................20
FUEL...........................................................................................................................................21
FUEL RECOMMENDATIONS...............................................................................................23
CONTROLS & FEATURES................................................................................. 24
COMPONENT & CONTROL LOCATIONS ........................................................................24
CONTROLS...............................................................................................................................26
MAIN Switch ......................................................................................................................26
ENGINE START Button....................................................................................................26
Starter Grip.........................................................................................................................27
Eco Throttle® Switch .......................................................................................................27
CO-MINDER® (CO Shut-off System) ...........................................................................28
Parallel Operation Outlets ............................................................................................30
Voltage Selector Switch.................................................................................................30
AC Circuit Protectors ......................................................................................................31
Ground Fault Circuit Interrupter (GFCI) Receptacle............................................32
Folding Handle .................................................................................................................33
Maintenance Covers.......................................................................................................34
FEATURES ................................................................................................................................35
Ground Terminal..............................................................................................................35
31Z376290-A.book 3 ページ 2025年10月24日 金曜日 午後2時44分

4
CONTENTS
OUTPUT Indicator ............................................................................................................36
OVERLOAD ALARM (Indicator)....................................................................................36
OIL ALERT®/CHECK Indicator .......................................................................................37
i-Monitor™ ..........................................................................................................................38
Fuel Gauge (AN1 type only).........................................................................................43
Bluetooth® Function ........................................................................................................44
Smartphone application ...............................................................................................44
BEFORE OPERATION....................................................................................... 45
ARE YOU READY TO GET STARTED? ...............................................................................45
Knowledge .........................................................................................................................45
IS YOUR GENERATOR READY TO GO?............................................................................45
Check the Engine.............................................................................................................46
Check the GFCI..................................................................................................................46
Check the Battery Voltage............................................................................................46
Battery Maintenance Cover and Wheel Kit.............................................................47
AC Appliance and Power Cord....................................................................................48
ENGINE OIL LEVEL CHECK ..................................................................................................49
AIR FILTER CHECK .................................................................................................................50
SAFE OPERATING PRECAUTIONS ....................................................................................51
OPERATION ..................................................................................................... 52
STARTING THE ENGINE .......................................................................................................52
STOPPING THE ENGINE.......................................................................................................55
STARTING AND STOPPING THE ENGINE with Bluetooth® ENABLED
SMARTPHONE ...................................................................................................................56
HOW TO RESTART WHEN STOPPED BY CO-MINDER®
(CO SHUT-OFF SYSTEM).................................................................................................56
GFCI OPERATION CHECK....................................................................................................57
AC OPERATION ......................................................................................................................60
AC Applications ................................................................................................................62
AC Receptacle Selection................................................................................................63
Power Producing Circuits .............................................................................................63
Voltage Selector Switch.................................................................................................64
AC PARALLEL OPERATION.................................................................................................65
AC Parallel Operation Applications...........................................................................67
ECO THROTTLE® SYSTEM ...................................................................................................70
STANDBY POWER..................................................................................................................71
Connections to a Building’s Electrical System.......................................................71
System Ground.................................................................................................................71
Special Requirements.....................................................................................................72
31Z376290-A.book 4 ページ 2025年10月24日 金曜日 午後2時44分

5
CONTENTS
SERVICING YOUR GENERATOR ...................................................................... 73
THE IMPORTANCE OF MAINTENANCE...........................................................................73
MAINTENANCE SAFETY ......................................................................................................74
Safety Precautions...........................................................................................................74
MAINTENANCE SCHEDULE................................................................................................75
ENGINE OIL CHANGE ...........................................................................................................76
AIR CLEANER SERVICE .........................................................................................................78
Foam Air Filter Cleaning................................................................................................78
SPARK PLUG SERVICE ..........................................................................................................79
SPARK ARRESTER SERVICE .................................................................................................81
BATTERY SERVICE..................................................................................................................82
Emergency Procedures..................................................................................................82
Battery Removal ...............................................................................................................83
Battery Charging..............................................................................................................85
Battery Installation ..........................................................................................................85
FUSE...........................................................................................................................................86
STORAGE ......................................................................................................... 87
STORAGE PREPARATION ....................................................................................................87
Cleaning ..............................................................................................................................87
Fuel .......................................................................................................................................87
Engine Oil ...........................................................................................................................90
Engine Cylinder ................................................................................................................90
Battery..................................................................................................................................90
STORAGE PRECAUTIONS....................................................................................................91
REMOVAL FROM STORAGE................................................................................................91
TRANSPORTING .............................................................................................. 92
TAKING CARE OF UNEXPECTED PROBLEMS ................................................. 93
ENGINE WILL NOT START ...................................................................................................93
ENGINE LACKS POWER........................................................................................................94
NO POWER AT THE AC RECEPTACLES ...........................................................................94
ENGINE AUTOMATICALLY STOP AND THE CO ALARM INDICATOR
FLASHING ...........................................................................................................................95
ENGINE AUTOMATICALLY STOP AND THE FAULT/CO SENSOR LIFE
INDICATOR FLASHING....................................................................................................95
FAULT/CO SENSOR LIFE INDICATOR FLASHING WHEN RUNNING
THE ENGINE........................................................................................................................95
TECHNICAL INFORMATION............................................................................ 96
SERIAL NUMBER AND TYPE LOCATION.........................................................................96
EMISSION CONTROL SYSTEM INFORMATION.............................................................97
31Z376290-A.book 5 ページ 2025年10月24日 金曜日 午後2時44分

6
CONTENTS
Source of Emissions ........................................................................................................97
The U.S. and California Clean Air Acts, and Environment and Climate
Change Canada (ECCC).............................................................................................97
Tampering and Altering................................................................................................98
Problems That May Affect Emissions........................................................................98
Replacement Parts ..........................................................................................................99
Maintenance......................................................................................................................99
Air Index ...........................................................................................................................100
Emission Control Information ..................................................................................100
SPECIFICATIONS.................................................................................................................101
WIRING DIAGRAM..............................................................................................................103
CONSUMER INFORMATION.......................................................................... 107
DEALER LOCATOR INFORMATION............................................................................... 107
Honda PUBLICATIONS......................................................................................................107
CUSTOMER SERVICE INFORMATION ...........................................................................108
Distributor’s Limited Warranty...................................................................................... 109
Emission Control System Warranty............................................................................. 114
REGISTRATION .................................................................................................................... 119
Please Register Your Generator...............................................................................119
OPTIONAL PARTS ......................................................................................... 120
HANGER KIT .........................................................................................................................120
REFERENCE INFORMATION.......................................................................... 121
INDEX............................................................................................................. 122
QUICK REFERENCE INFORMATION.......................................inside back cover
31Z376290-A.book 6 ページ 2025年10月24日 金曜日 午後2時44分

7
GENERATOR SAFETY
IMPORTANT SAFETY INFORMATION
Honda generators are designed for use with electrical equipment that has
suitable power requirements. Other uses can result in injury to the operator or
damage to the generator and other property.
Most injuries or property damage can be prevented if you follow all instructions
in this manual and on the generator. The most common hazards are discussed
below, along with the best way to protect yourself and others.
Operator Responsibility
• Never attempt to modify the generator. It can cause an accident as well as
damage to the generator and appliances.
• Know how to stop the generator quickly in case of emergency.
• Understand the use of all generator controls, output receptacles, and
connections.
• Be sure that anyone who operates the generator receives proper instruction.
• Protect children by keeping them at a safe distance from the generator.
• Obey all applicable laws and regulations where the generator is used.
31Z376290-A.book 7 ページ 2025年10月24日 金曜日 午後2時44分

GENERATOR SAFETY
8
Carbon Monoxide Hazards
A generator's exhaust contains toxic carbon monoxide, which you cannot see or
smell. Breathing carbon monoxide can KILL YOU IN MINUTES. To avoid carbon
monoxide poisoning, follow these instructions when operating a generator:
• Only run a generator OUTSIDE, far away from windows, doors, and vents with
engine exhaust directed away from occupied structures.
• Never operate a generator inside a house, garage, basement, crawl space, any
type of vehicle, trailer, or boat, or any enclosed or partly enclosed space.
• Never operate a generator near open doors, windows, vents, or hatches.
• Get fresh air and seek medical attention immediately if you suspect you have
inhaled carbon monoxide.
Early symptoms of carbon monoxide exposure include headache, fatigue,
shortness of breath, nausea, and dizziness. Continued exposure to carbon
monoxide can cause loss of muscular coordination, loss of consciousness, and
then death.
To alert you to potentially dangerous levels of carbon monoxide coming from a
generator operating outside or from other sources, install battery operated
carbon monoxide alarms or plug-in carbon monoxide alarms with battery back-
up on every level of your home, outside sleeping areas, inside any type of
vehicle, trailer, or boat in accordance with the alarm’s instructions.
CO-MINDER®:
This generator is equipped with a CO-MINDER® system that automatically stops
the engine before the surrounding carbon monoxide concentration exceeds a
certain concentration.
• Do not modify the CO-MINDER.
• The CO-MINDER cannot prevent all danger associated with or caused by
carbon monoxide. Pay careful attention to the location of the generator (see
page 28).
31Z376290-A.book 8 ページ 2025年10月24日 金曜日 午後2時44分

GENERATOR SAFETY
9
Electric Shock Hazards
The generator produces enough electric power to cause a serious shock or
electrocution if misused.
• Do not use in wet conditions. Keep the generator dry.
– Do not use in the rain or snow.
– Do not use near pool or a sprinkler system.
– Do not use when your hands are wet.
• If the generator is stored outdoors, unprotected from the weather, check all
of the electrical components on the control panel before each use. Moisture
or ice can cause a malfunction or short circuit in electrical components that
could result in electrocution.
• Do not connect to a building’s electrical system unless an isolation switch has
been installed by a qualified electrician.
• For parallel operation, use only a Honda approved parallel kit (optional
equipment) when connecting one EU7000iS to another EU7000iS generator.
• Never connect different generator models.
Fire and Burn Hazards
• The exhaust system gets hot enough to ignite some materials.
– Keep the generator at least 3 feet (1 meter) away from buildings and any
type of vehicle, trailer, boat, or other equipment during operation.
– Do not enclose the generator in any structure.
– Keep flammable materials away from the generator.
– Generators with standard equipment transport wheels must not be
operated with the wheels and/or stands removed.
– Do not block intake or exhaust vents, hoses, ports, or restrict air into or
away from generator.
– Do not add, remove, or modify covers, panels, cowlings, or straps.
• The muffler becomes very hot during operation and remains hot for a while
after stopping the engine. Be careful not to touch the muffler while it is hot.
Let the engine cool before storing the generator.
• Do not pour the water directly on the generator to put out the fire when it
occurs. Use an appropriate fire extinguisher specially designed for electric fire
or oil fire.
31Z376290-A.book 9 ページ 2025年10月24日 金曜日 午後2時44分

GENERATOR SAFETY
10
Refuel With Care
Gasoline is highly flammable, and gasoline vapor can explode.
• Do not refuel during operation.
• Allow the engine to cool if it has been in operation.
• Refuel only outdoors in a well-ventilated area and on a level surface.
• Never smoke near gasoline, and keep other flames and sparks away.
• Do not overfill the fuel tank.
• Make sure that any spilled fuel has been wiped up and cleaned before
starting the engine.
• Always store gasoline in an approved container.
Vehicles and Transportation Hazards
• Do not operate the generator while it is being transported or while it is
mounted to any type of vehicle, trailer, or boat.
• Do not operate the generator when it is in a storage, cargo, or security
enclosure, including any RV generator bay.
• Always completely remove the generator from the vehicle, RV, truck, trailer,
boat, other equipment or structure during operation.
• The generator must remain stationary while in operation.
31Z376290-A.book 10 ページ 2025年10月24日 金曜日 午後2時44分

GENERATOR SAFETY
11
SAFETY LABEL LOCATIONS
These labels warn you of potential hazards that can cause serious injury. Read
them carefully.
If a label comes off or becomes hard to read, contact your servicing dealer for a
replacement.
AN1 type
31Z376290-A.book 11 ページ 2025年10月24日 金曜日 午後2時44分

GENERATOR SAFETY
12
AC1 type
31Z376290-A.book 12 ページ 2025年10月24日 金曜日 午後2時44分

GENERATOR SAFETY
13
AN1 type AC1 type
ALL types
ALL types
31Z376290-A.book 13 ページ 2025年10月24日 金曜日 午後2時44分

14
ASSEMBLY
SAFETY
The Importance of Proper Assembly
Proper assembly is essential to operator safety and the reliability of the
machine.
We cannot warn you of every conceivable hazard that can arise in performing
this assembly. Only you can decide whether or not you should perform a given
task.
Improper assembly can cause an unsafe
condition.
Failure to properly follow assembly
procedures can lead to serious injury or
death.
Follow the procedures and precautions
in this owner’s manual carefully.
31Z376290-A.book 14 ページ 2025年10月24日 金曜日 午後2時44分

ASSEMBLY
15
ASSEMBLY
Unpacking
1. Remove the generator and loose parts box from the carton.
2. Compare the loose parts with the inventory list below.
Tools Required: 12 mm wrench, 10 mm wrench or Phillips head screwdriver for
battery connections, pliers (not included)
Do not add fuel or oil before tipping the generator. Oil or fuel may damage the
engine or your property.
Loose Parts
Check all loose parts against the following list.
Ref. No. Description Qty.
1 Wheel 2
2Axle 1
3Stand 2
4 20 mm Washer 2
5 4.0×28 mm
Cotter pin
2
6 8×20 mm
Flange bolt
8
(1)
(2)
(3)
(4)
(5)
(6)
31Z376290-A.book 15 ページ 2025年10月24日 金曜日 午後2時44分

ASSEMBLY
16
Wheel Kit Installation
Do not operate the generator without the wheel kit installed. The wheel kit
provides air space between the ground and the generator air intake.
Generators with standard equipment transport wheels must be operated with the
wheels and stands installed to provide air space between the ground and the
generator air intake. This prevents fuel, dirt, or debris from being drawn into the
generator air intake, which can cause generator or engine damage.
1. Install the two stands on the under frame by tightening four 8×20 mm flange
bolts.
2. Install the two wheels on the axle by tightening the 20 mm washers and
4.0×28 mm cotter pins. After installing the split pins, bend the pins to ensure
that the wheels are secured to the axle.
Operating the generator without the
wheel kit installed can pinch or block air
vent tubes or fuel drain tubes, causing
fuel to spill on the ground or, inside or
around the generator.
Spilled fuel can cause a fire and you can
be burned or seriously injured.
Always operate the generator with the
wheel kit installed and do not modify
any part of the generator, including air,
drain and fuel tubes, or covers, panels
and air intakes.
31Z376290-A.book 16 ページ 2025年10月24日 金曜日 午後2時44分

ASSEMBLY
17
3. Install the axle assembly on the generator by tightening four 8×20 mm flange
bolts. Make sure that the axle's direction is correct as it is shown in the
illustration.
Torque: 19.5 lbf·ft (26.5 N·m, 2.7 kgf·m)
Battery
WARNING: Battery posts, terminals, and related accessories contain lead and
lead compounds. Wash your hands after handling.
The battery is disconnected and strapped into the battery tray for shipment.
1. Remove the battery maintenance cover (see page 83).
2. Remove the battery strap from the bottom hook, and then remove the
battery.
3. Charge the battery properly (see page 85).
Pull out the harness and reinstall the battery.
STAND
8×20 mm
FLANGE BOLT (4)
4.0×28 mm
COTTER PIN (2)
AXLE
WHEEL (2)
8×20 mm
FLANGE BOLT (4)
20 mm WASHER (2)
SHORTER
MUFFLER TIP
31Z376290-A.book 17 ページ 2025年10月24日 金曜日 午後2時44分

ASSEMBLY
18
4. Remove the protective cover from the battery positive (+) terminal, and
connect the positive (+) cable to the battery positive (+) terminal. Make sure
to cover the terminal with the battery boot.
5. Connect the negative (–) cable to the battery negative (–) terminal.
6. Secure the battery by hooking the strap onto the bottom hook of the
generator.
7. Install the battery maintenance cover in the reverse order of removal (see
page 83).
Never operate the generator without the battery maintenance cover in place,
as poor engine and generator performance will result.
BOTTOM
HOOK
4-PIN BLUE COUPLER HARNESS
BATTERY CABLES
NEGATIVE (-) CABLE
BATTERY STRAP
BATTERY
POSITIVE (+) CABLE
BATTERY BOOT
31Z376290-A.book 18 ページ 2025年10月24日 金曜日 午後2時44分

19
INITIAL USE INSTRUCTIONS
ENGINE OIL
The generator is shipped WITHOUT OIL in the engine.
1. Place the generator on a level
surface.
2. Open the right maintenance cover
by turning its latch
counterclockwise.
3. Remove the oil filler cap by turning
it counterclockwise.
4. Add enough oil to bring the oil level to the upper limit of the oil filler neck.
SAE10W-30 API service category SJ or later (or equivalent) is recommended
for general use; for additional recommendations (see page 20).
Maximum oil capacity: 1.2 US qt (1.1 L)
Do not overfill the engine with oil. If the engine is overfilled, the excess oil
may be transferred to the air cleaner housing and air filter.
5. Reinstall the oil filler cap securely.
6. Close the right maintenance cover by turning its latch clockwise.
RIGHT MAINTENANCE COVER
LATCH
OIL FILLER CAP
OIL FILLER NECK
UPPER LIMIT
(The oil exists to the
oil filler neck.)
31Z376290-A.book 19 ページ 2025年10月24日 金曜日 午後2時44分

INITIAL USE INSTRUCTIONS
20
ENGINE OIL RECOMMENDATIONS
Oil is a major factor affecting performance and service life. Use 4-stroke
automotive detergent oil.
SAE 10W–30 is recommended for general use. Other viscosities shown in the
chart may be used when the average temperature in your area is within the
recommended range.
Read the instructions on the oil container before use.
The SAE oil viscosity and service category are in the API label on the oil
container. Honda recommends that you use API service category SJ or later (or
equivalent) oil.
AMBIENT TEMPERATURE
31Z376290-A.book 20 ページ 2025年10月24日 金曜日 午後2時44分

INITIAL USE INSTRUCTIONS
21
FUEL
Add fuel to the generator in a well-ventilated area. Fuel only outdoors. Keep
gasoline away from appliances, such as pilot lights, barbecues, electric
appliances, power tools, etc. Spilled fuel is not only a fire hazard, it causes
environmental damage. Fuel carefully to avoid spilling fuel. Wipe up spills
immediately. Do not fill the fuel tank above the upper level mark (red) on the
fuel strainer. After fueling, reinstall the fuel tank cap securely.
When appropriate, with the engine stopped, check the fuel gauge for the fuel
level. If the fuel level is low, wait for the generator to cool off and refill the fuel
tank.
This engine is certified to operate on unleaded gasoline with a pump octane
rating of 86 or higher. Refer to "FUEL RECOMMENDATIONS" (see page 23) for
additional fuel recommendations.
Fuel can damage paint and plastic. Be careful not to spill fuel when filling your fuel
tank. Damage caused by spilled fuel is not covered under the Distributor’s Limited
Warranty (US) / Distributor's warranty (C.A.).
Remaining fuel amount can be confirmed with the fuel gauge (AN1 type, see
page 43) / i-Monitor display (AC1 type, see page 41).
Gasoline is highly flammable and
explosive.
You can be burned or seriously injured
when handling fuel.
• Stop the engine and let it cool before
handling fuel.
• Keep heat, sparks, and flame away.
• Handle fuel only outdoors.
• Keep away from your vehicle.
• Wipe up spills immediately.
31Z376290-A.book 21 ページ 2025年10月24日 金曜日 午後2時44分

INITIAL USE INSTRUCTIONS
22
1. Make sure the MAIN switch is in the OFF position.
2. Remove the fuel tank cap by turning it counterclockwise.
3. Fuel carefully to avoid spilling fuel. Do not fill the fuel tank above the upper
level mark (red) on the fuel strainer or fuel may flow into the charcoal canister
causing fuel spillage.
4. After fueling, reinstall the fuel tank cap securely. (AN1 type) / After refueling,
reinstall the fuel tank cap until it clicks. (AC1 type)
FUEL TANK CAP TETHER
UPPER LEVEL MARK (RED)
FUEL
STRAINER
AN1 type
FUEL TANK CAP
TETHER
UPPER LEVEL MARK
(RED)
FUEL
STRAINER
AC1 type
31Z376290-A.book 22 ページ 2025年10月24日 金曜日 午後2時44分

INITIAL USE INSTRUCTIONS
23
Fuel can damage paint and plastic. Be careful not to spill fuel when filling your fuel
tank. Damage caused by spilled fuel is not covered under the Distributor’s Limited
Warranty (US) / Distributor's warranty (C.A.).
Move the generator at least 10 feet (3 meters) away from the fueling source and
site before starting the engine.
FUEL RECOMMENDATIONS
This engine is certified to operate on regular unleaded gasoline with a pump
octane rating of 86 or higher.
Use unleaded gasoline only, or the catalyzer will lose its effectiveness and
negatively affect exhaust emissions.
Never use gasoline that is stale, contaminated, or mixed with oil. Avoid getting
dirt or water in the fuel tank.
You may use regular unleaded gasoline containing no more than 10% ethanol
(E10) or 5% methanol by volume. In addition, methanol must contain cosolvents
and corrosion inhibitors.
Use of fuels with content of ethanol or methanol greater than shown above may
cause starting and/or performance problems. It may also damage metal, rubber,
and plastic parts of the fuel system.
Engine damage or performance problems that result from using a fuel with
percentages of ethanol or methanol greater than shown above and leaded
gasoline are not covered under the Distributor Limited Warranty (US) /
Distributor's warranty (C.A.).
If your equipment will be used on an infrequent basis, refer to the fuel section of
"STORAGE" chapter (see page 87) for additional information regarding fuel
deterioration.
31Z376290-A.book 23 ページ 2025年10月24日 金曜日 午後2時44分

24
CONTROLS & FEATURES
COMPONENT & CONTROL LOCATIONS
Use the illustrations on these pages to locate and identify the most frequently
used controls.
OVERLOAD ALARM INDICATOR
OIL ALERT/CHECK INDICATOR
i-MONITOR
BUTTON
ECO THROTTLE SWITCH
AC CIRCUIT PROTECTORS
RECEPTACLES
OUTPUT INDICATOR
i-MONITOR
ENGINE START
BUTTON
VOLTAGE SELECTOR SWITCH
MAIN SWITCH
PARALLEL OPERATION OUTLETS
GFCI RECEPTACLES
CO-MINDER®
31Z376290-A.book 24 ページ 2025年10月24日 金曜日 午後2時44分

CONTROLS & FEATURES
25
FUEL GAUGE (AN1 type)
RIGHT MAINTENANCE COVER
OIL DRAIN PLUG
MUFFLER TIP
FUEL TANK CAP
STARTER GRIP
OIL FILLER CAP
GROUND TERMINAL
STANDHANDLE
BATTERY
(inside battery
maintenance cover)
FUSE
(inside battery
maintenance cover)
WHEEL
LEFT MAINTENANCE COVER
AIR CLEANER
SPARK PLUG
INSPECTION COVER
31Z376290-A.book 25 ページ 2025年10月24日 金曜日 午後2時44分

CONTROLS & FEATURES
26
CONTROLS
MAIN Switch
The MAIN switch controls the ignition
system.
OFF – Stops the engine. The main
switch key can be removed/inserted.
ON – Running position, and for
starting with the ENGINE START
button or recoil starter.
If the MAIN switch is left in the ON
position without starting the engine
within 30 minutes, the ENGINE START
button will not function.
• To restart the engine using the
ENGINE START button, the MAIN
switch must be turned to the OFF
position, and then back to the ON
position.
• If the MAIN switch is left on longer
than 30 minutes, the engine will still
start using a Bluetooth® enabled
smartphone.
ENGINE START Button
With the MAIN switch in the ON
position, press and release the ENGINE
START button to start the engine.
MAIN SWITCH
ON
OFF
ENGINE START BUTTON
31Z376290-A.book 26 ページ 2025年10月24日 金曜日 午後2時44分

CONTROLS & FEATURES
27
Starter Grip
Used when the battery voltage is too
low to turn the starter motor. Pulling
the starter grip operates the recoil
starter to start the engine.
• Do not exceed 20 degrees from
horizontal when pulling the starter
grip or the starter rope may become
damaged.
• Do not allow the starter grip to snap
back against the engine. Return it
gently to prevent damage to the
starter.
• Do not let the starter rope rub against
the generator body, or the rope will
wear out prematurely.
Eco Throttle® Switch
The Eco Throttle system automatically reduces engine speed when all loads are
turned off or disconnected. When appliances are turned on or reconnected, the
engine returns to the proper speed to power the electrical load.
If high electrical loads are connected simultaneously, turn the Eco Throttle
switch to the OFF position to reduce voltage changes.
ON – Recommended to minimize fuel
consumption and further reduce noise
levels when a reduced load or no load
is applied to the generator.
OFF – The Eco Throttle system does
not operate. Generator operates at full
speed.
STARTER GRIP
20°
ECO THROTTLE SWITCH
OFF
ON
31Z376290-A.book 27 ページ 2025年10月24日 金曜日 午後2時44分

CONTROLS & FEATURES
28
CO-MINDER® (CO Shut-off System)
CO-MINDER® is a system that automatically stops the engine before the
surrounding carbon monoxide concentration exceeds a certain level.
If the CO-MINDER detects a high carbon monoxide concentration, the engine
will stop and the CO ALARM indicator will flash for about five minutes.
Continuously using the generator in areas with high concentrations of carbon
monoxide can cause serious health hazards due to carbon monoxide poisoning
(see page 8). If you are in the same area as the generator, evacuate the area
immediately. Get fresh air and seek medical attention immediately if you feel
sick or suspect you have inhaled carbon monoxide. Ventilate the area or space
where the generator is located.
If the engine is stopped by the CO-MINDER system, change the operating
location of the generator.
• Do not operate the generator in an enclosed or partly enclosed area such as a
garage.
• Do not enclose or cover the generator with boards or a tent, even when it is
outside and away from a building.
• Place the generator so that the muffler is pointed in the same direction as the
wind is blowing and the exhaust is directed away from buildings, other
structures, or vehicles (see page 68).
• Avoid placing the generator near devices that emit carbon monoxide, such as
another generator.
• When operating generators in parallel operation, place the generators so that
the exhaust from one generator is not directed onto the other generator (see
page 68).
CO-MINDER® RESET BUTTON
CO ALARM INDICATOR
FAULT/CO SENSOR LIFE
INDICATOR
31Z376290-A.book 28 ページ 2025年10月24日 金曜日 午後2時44分

CONTROLS & FEATURES
29
RESTARTING THE ENGINE
When the engine is stopped automatically by CO-MINDER®, press the CO-
MINDER reset button to restart the engine.
If the engine is restarted without pressing the CO-MINDER reset button, the
engine will automatically stop immediately after restarting and the CO ALARM
indicator will flash for approximately five minutes.
Resetting the CO-MINDER is possible only after the CO ALARM indicator is
turned off.
CO-MINDER® MALFUNCTION DETECTION
If the CO-MINDER® detects a system malfunction, the engine will stop
automatically and the FAULT/CO SENSOR LIFE indicator will flash for
approximately five minutes. Press the CO-MINDER reset button to turn off the
FAULT/CO SENSOR LIFE indicator. If the engine will not remain running after
attempting to restart it and the FAULT/CO SENSOR LIFE indicator comes on
again, there may be a system malfunction. If this occurs, do not attempt to
restart the generator more than two times. If the CO-MINDER system is
malfunctioning, it cannot warn you of potential high concentrations of carbon
monoxide. Move the generator to a well-ventilated location and consult an
authorized Honda Power Equipment dealer.
CO SENSOR LIFE
If the FAULT/CO SENSOR LIFE indicator flashes when operating the generator,
the CO-MINDER® may be reaching the end of its useful lifespan and will
eventually need replacement.
• If the indicator flashes once every four seconds, this means there is
approximately six months to one year of life left in the CO-MINDER.
• If the indicator flashes once every two seconds, this means there is
approximately six months of life or less left in the CO-MINDER.
• The FAULT/CO SENSOR LIFE indicator indicates the estimated life left in the CO-
MINDER®.
• The generator stopping period and storage period are also included in the useful
lifespan of the CO-MINDER.
• Contact an authorized Honda Power Equipment dealer for CO-MINDER
replacement.
31Z376290-A.book 29 ページ 2025年10月24日 金曜日 午後2時44分

CONTROLS & FEATURES
30
Parallel Operation Outlets
These outlets are used for connecting the EU7000iS to another EU7000iS
generator for parallel operation (see page 65). A Honda approved parallel kit
(optional equipment) is required for parallel operation. This kit can be
purchased from an authorized Honda Power Equipment dealer.
Voltage Selector Switch
Select the voltage before starting the engine.
Always disconnect or turn OFF all appliances or tools connected to the
generator before changing the voltage selector switch position.
The voltage selector switch changes generator output to produce "120 V ONLY"
or "120 V/240 V". If a 240 V appliance is connected to the 4-prong receptacle, the
switch must be in the "120 V/240 V" position. If only the 120 V 3-prong
receptacles are being used, select the "120 V ONLY" position.
SWITCH POSITION
• 120 V/240 V: The 120 V and
120 V/240 V receptacles can be used
simultaneously.
• 120 V ONLY: ONLY the 120 V
receptacles can be used. Do not use
the 120 V/240 V receptacle in this
position. The most power will be
available at the 30 A 120 V locking
plug receptacle.
PARALLEL OPERATION OUTLETS
120 V/240 V
VOLTAGE SELECTOR SWITCH
120 V ONLY
31Z376290-A.book 30 ページ 2025年10月24日 金曜日 午後2時44分

CONTROLS & FEATURES
31
AC Circuit Protectors
The AC circuit protectors will automatically switch OFF if there is a short circuit
or a significant overload of the generator at each receptacle. If an AC circuit
protector switches OFF automatically, check that the appliance is working
properly and does not exceed the rated load capacity of the circuit before
resetting the AC circuit protector ON.
120 V/240 V 30 A
AC CIRCUIT PROTECTOR for
Receptacle
OFF
ON
AC CIRCUIT PROTECTOR for
Receptacle
PUSH
GFCI RECEPTACLE
(120 V 20 A DUPLEX RECEPTACLE)
GFCI RECEPTACLE
(120 V 20 A DUPLEX RECEPTACLE)
120 V 30 A
AC CIRCUIT PROTECTOR
for Receptacle
AC CIRCUIT PROTECTOR for
Receptacle
ON
OFF
31Z376290-A.book 31 ページ 2025年10月24日 金曜日 午後2時44分

CONTROLS & FEATURES
32
Ground Fault Circuit Interrupter (GFCI) Receptacle
Each 120 V 20 A duplex receptacle is protected by a Ground Fault Circuit
Interrupter (GFCI) for protection against the shock hazard of ground fault
currents.
An example of ground fault current is the current that would flow through a
person who is using an appliance with faulty insulation and, at the same time, is
in contact with an electrical ground such as a plumbing fixture, wet floor, or
earth. The GFCI will protect against current flowing through that person.
The GFCI will not protect against short circuit or overloads.
GFCIs can be expected to interrupt power supply if there are ground faults or
stray current imposed on the wiring by other electrical devices, wiring, or
equipment. Due to the risk of a power interruption, this generator is not
recommended for powering medical or life support equipment.
GFCI RECEPTACLES
(120 V 20 A DUPLEX RECEPTACLES)
31Z376290-A.book 32 ページ 2025年10月24日 金曜日 午後2時44分

CONTROLS & FEATURES
33
Folding Handle
The foldable handle makes the generator easy to push and should be folded
when the generator is stationary. Do not rest objects on the extended handle.
To extend the handle, lift handle upward. Lock levers will lock and secure the
handle into place.
To fold the handle,
1. Press both handle lock levers downward.
2. Lower the handle.
HANDLE
Handle in
pushing
position
Handle in
stationary
position
HANDLE LOCK LEVER
31Z376290-A.book 33 ページ 2025年10月24日 金曜日 午後2時44分

CONTROLS & FEATURES
34
Maintenance Covers
Open and close the maintenance cover for maintenance of this generator.
Open the right maintenance cover, to use the recoil starter when the battery is
discharged. Be sure the maintenance cover is closed while the generator is running.
Running the generator with maintenance cover(s) open will adversely affect the
engine performance, and will cause the generator to overheat.
Open the right maintenance cover for:
• Engine oil inspection/replacement
•Recoil starter
Open the left maintenance cover for:
• Spark plug inspection/replacement
• Air cleaner inspection/cleaning
To open, turn the latch 90° counterclockwise to unlock and open the
maintenance cover.
To close, turn the latch 90° clockwise to lock while pushing the cover.
LATCH LATCH
LEFT MAINTENANCE COVER
LATCH
RIGHT MAINTENANCE COVER
Push the cover closed and turn
the latch.
31Z376290-A.book 34 ページ 2025年10月24日 金曜日 午後2時44分

CONTROLS & FEATURES
35
FEATURES
Ground Terminal
The ground terminal is connected to the frame of the generator, the metal non-
current-carrying parts of the generator, and the ground terminals of each
receptacle.
Before using the ground terminal, consult a qualified electrician, electrical
inspector, or local agency having jurisdiction for local codes or ordinances that
apply to the intended use of the generator.
NEUTRAL FLOATING:
• The generator (stator winding) is isolated from the frame and from the AC
receptacle ground pin.
• Electrical devices that require a grounded receptacle pin connection will not
function if the receptacle ground pin is not functional.
GROUND TERMINAL
31Z376290-A.book 35 ページ 2025年10月24日 金曜日 午後2時44分

CONTROLS & FEATURES
36
OUTPUT Indicator
The green OUTPUT indicator is illuminated when the generator is operating
normally. It indicates that the generator is producing electrical power at the
receptacles.
OVERLOAD ALARM (Indicator)
If the generator is overloaded, or if there is a short circuit in a connected
appliance, or if the inverter is overheated, the red OVERLOAD ALARM indicator
will come ON. When the generator is operating overloaded, the red OVERLOAD
ALARM indicator will stay ON and, after about five seconds, current to the
connected appliance(s) will shut off, and the green OUTPUT indicator will go
OFF.
OUTPUT INDICATOR (GREEN)
OVERLOAD ALARM INDICATOR (RED)
31Z376290-A.book 36 ページ 2025年10月24日 金曜日 午後2時44分

CONTROLS & FEATURES
37
OIL ALERT®/CHECK Indicator
The Oil Alert system is designed to prevent engine damage caused by an
insufficient amount of oil in the crankcase. Before the oil level in the crankcase
can fall below a safe limit, the OIL ALERT/CHECK indicator comes ON, and the Oil
Alert system will automatically stop the engine (the MAIN switch will remain in
the ON position).
The i-Monitor display will show "OIL" on the screen and the OIL ALERT/CHECK
indicator will illuminate.
If the engine stops or the OIL ALERT/CHECK indicator comes ON when you press
the ENGINE START button or pull the starter grip, check the engine oil level (see
page 49) before troubleshooting in other areas.
Even when oil is added to the engine, the generator will not restart until the OIL
ALERT/CHECK indicator is reset. To reset the OIL ALERT/CHECK indicator, turn
the MAIN switch to the OFF position, add the proper amount of oil (see page
49), and then turn the MAIN switch back to the ON position.
If the OIL ALERT/CHECK indicator blinks, consult an authorized Honda Power
Equipment dealer.
OIL ALERT/CHECK INDICATOR (RED)
It blinks.
31Z376290-A.book 37 ページ 2025年10月24日 金曜日 午後2時44分

CONTROLS & FEATURES
38
i-Monitor™
The i-Monitor is a user interface that allows the operator to view various
information.
i-Monitor at Startup
As the MAIN switch is turned to ON position, all three indicators will blink once
and the i-Monitor starts displaying the generator's status in a short while. The
condition of the i-Monitor display and all three indicators can be checked. Once
the generator is running, the green OUTPUT indicator and the i-Monitor display
will remain lit.
Display Backlight Blinks
If the Main switch is left in the ON position for over 30 seconds without starting
the engine, the display will start to blink. If the Main switch is left in the ON
position for over 30 minutes without starting the engine, the display will turn
off.
i-Monitor Display
The i-Monitor display is divided into two screens.
The single-digit screen displays the i-Monitor mode, which is represented by a
number:
• Mode 1: Total Operating Hours
• Mode 2: Power Output
• Mode 3: Engine RPM
• Mode 4: Battery Voltage
• Mode 5: Remaining Operating Hours
• Mode 6 (AC1 type only): Remaining Fuel Amount
The four-digit screen displays each mode values or any activated error
messages.
The i-Monitor mode switches sequentially by pressing the i-Monitor button.
When you turn the MAIN switch OFF and then ON again, the i-Monitor displays:
• AN1 type: mode 1 - Total Operation Hours
• AC1 type: the mode displayed before turning the MAIN switch to OFF
position.
31Z376290-A.book 38 ページ 2025年10月24日 金曜日 午後2時44分

CONTROLS & FEATURES
39
i-Monitor Display Mode 1 – Total Operating Hours
This mode displays the total operating hours of the generator. When the
generator is running, the total operating time accumulates. If the total
operating time is less than one hour, the numeric display will be "0." When the
operating time is one hour or greater, the display will be "1" or "2" and so on.
Base the generator’s maintenance schedule on the accumulated time
displayed.
i-Monitor Display Mode 2 – Power Output
This mode displays an approximate generator output on the display screen. The
output is expressed in VA (volt-amperes). The output value is not an exact
measurement and should be regarded as a reference only. Power output will
not display until a load is connected to the generator.
i-Monitor Display Mode 3 – Engine RPM
When the i-Monitor is in this mode, the engine’s speed, expressed in
revolutions-per-minute (RPM), is displayed.
SINGLE-DIGIT SCREEN DISPLAY i-MONITOR BUTTON
FOUR-DIGIT SCREEN DISPLAY
31Z376290-A.book 39 ページ 2025年10月24日 金曜日 午後2時44分

CONTROLS & FEATURES
40
i-Monitor Display Mode 4 – Battery Voltage
This mode displays the battery condition, expressed in Volts DC.
i-Monitor Display Mode 5 – Remaining Operating Hours
This mode displays the remaining operating hours of the generator before it
runs out of fuel.
• The remaining operating hours mode is not an exact measurement and
should only be regarded as a reference.
• When the engine is started in this mode, remaining operating hours will be
displayed in approximately 30 seconds after start-up animation is shown.
• "HI" is displayed when there is enough fuel, and "LO" is displayed when there
is not enough fuel.
31Z376290-A.book 40 ページ 2025年10月24日 金曜日 午後2時44分

CONTROLS & FEATURES
41
i-Monitor Display Mode 6 – Remaining Fuel Amount (AC1 type only)
This mode displays the remaining amount of the fuel in five levels.
• The remaining amount of fuel is not an exact measurement and should only
be regarded as a reference.
• To calculate remaining amount of the fuel properly, always turn the MAIN
switch to the OFF position when refueling.
• When the MAIN switch is turned to ON position in this mode, remaining fuel
amount will be displayed in approximately 10 seconds after start-up
animation is shown.
Fuel level: High
Fuel level: Low
31Z376290-A.book 41 ページ 2025年10月24日 金曜日 午後2時44分

CONTROLS & FEATURES
42
i-Monitor Low Battery Message
If the ENGINE START button is pressed and "batt" is shown on the i-Monitor
display, the battery voltage is too low to operate the engine’s electric starter.
Use the recoil starter to start the generator. Have the battery recharged and
checked (see page 85).
i-Monitor System Error Messages
If the generator has a system malfunction, it will show an error message on the
i-Monitor display. During remote control operation, an E-01 error message may
display if the ENGINE START button is pressed for more than 10 seconds. With
an E-01 error message, the engine will stay running and the electrical output
may stay constant.
Normal remote control operation will be restored after the E-01 error message
clears automatically. If the E-01 error message does not clear automatically or if
any other error message displays, contact an authorized Honda Power Equipment
dealer.
OIL ALERT/CHECK INDICATOR
ERROR MESSAGE
(Example: E-01)
31Z376290-A.book 42 ページ 2025年10月24日 金曜日 午後2時44分

CONTROLS & FEATURES
43
Fuel Gauge (AN1 type only)
The fuel gauge is a mechanical device that measures the fuel level in the tank.
The red indicator in the window will reference the level in relation to full or
empty. To provide increased operating time, start with a full tank before
operation. Check the fuel level with the generator on a level surface. Always
refuel with the engine OFF and cool.
FULL
FUEL GAUGE
EMPTY
31Z376290-A.book 43 ページ 2025年10月24日 金曜日 午後2時44分

CONTROLS & FEATURES
44
Bluetooth® Function
The generator is connected to a smartphone via a Bluetooth® connection.
• The range between your Bluetooth® enabled smartphone and the generator
can be maximized when there is a clear, obstruction free, line-of-sight
between devices. The connection distance is also affected by the type of
smartphone used and the surrounding environment, structures, and
electronic interference.
Smartphone application
The Honda "My Generator" smartphone application is for use only with Honda
generators equipped with Bluetooth® technology. The application is able to do
the following convenient functions:
• Remote start/stop:
Can start or stop the generator engine from a
distance
• Remote monitoring:
Displays power output level and remaining
fuel level
• Receive notifications:
Can receive error and maintenance alerts
Downloading the app
Go to the App Store (iOS) or Google Play
(Android) and search for "Honda My Generator"
to download the app.
Pairing (For first time connection only)
Refer to the Support on the Honda "My Generator" smartphone application to
pair the smartphone with the generator.
• Perform the pairing operation within 30 seconds after turning the MAIN
switch on the generator to the ON position.
Password for the Bluetooth® Connection
You may create your own personal password. Please record this password (see
page 96). It is very important that you do not forget or lose it. If a password is
lost, you must, at your expense, take your generator to an authorized Honda
Power Equipment dealer so it can be reset.
iOS Android
31Z376290-A.book 44 ページ 2025年10月24日 金曜日 午後2時44分

45
BEFORE OPERATION
ARE YOU READY TO GET STARTED?
Your safety is your responsibility. A little time spent in preparation will
significantly reduce your risk of injury.
Knowledge
Read and understand this manual. Know what the controls do and how to
operate them.
Familiarize yourself with the generator and its operation before you begin using
it. Know how to quickly shut off the generator in case of an emergency.
If the generator is being used to power appliances, be sure that they do not
exceed the generator’s load rating (see page 62).
IS YOUR GENERATOR READY TO GO?
For your safety, to ensure compliance with environmental regulations, and to
maximize the service life of your equipment, it is very important to take a few
moments before you operate the generator to check its condition. Be sure to
take care of any problem you find, or have your servicing dealer correct it,
before you operate the generator.
Failure to properly maintain this
generator, or failing to correct a problem
before operation, could result in a
significant malfunction.
Some malfunctions can cause serious
injuries or death.
Always perform a pre-operation
inspection before each operation and
correct any problems.
31Z376290-A.book 45 ページ 2025年10月24日 金曜日 午後2時44分

BEFORE OPERATION
46
To prevent a possible fire, keep the generator at least 3 feet (1 meter) away from
building walls, vehicles, and other equipment during operation. Do not place
flammable objects close to the engine or exhaust.
Before beginning your pre-operation checks, be sure the generator is on a level
surface and the MAIN switch is in the OFF position.
Generators with standard equipment transport wheels must not be operated with
the wheels and/or stands removed or else the generator may not operate correctly
and can become damaged.
Check the Engine
• Before each use, look around and underneath the engine for signs of oil or
gasoline leaks.
• Check the engine oil level (see page 49). A low engine oil level will cause the
Oil Alert system to shut down the engine.
• Check the air filters (see page 50). Dirty air filters will restrict air flow to the fuel
system, reducing engine and generator performance.
• Check the fuel level (see page 43 (AN1 type) / page 41 (AC1 type)). Starting
with a full tank will help to eliminate or reduce operating interruptions for
refueling.
Check the GFCI
Check the GFCI operation (see page 57) after starting the engine.
Check the Battery Voltage
Check the battery voltage with the i-Monitor (see page 40) before starting the
engine.
The battery voltage should be 12.3 V or higher.
If the battery voltage is low, charge the battery until the battery voltage is 12.3 V
or higher (see pages 82 to 85).
31Z376290-A.book 46 ページ 2025年10月24日 金曜日 午後2時44分

BEFORE OPERATION
47
Battery Maintenance Cover and Wheel Kit
Never operate the generator without the battery maintenance cover and wheel
kit in place, as poor engine and generator performance will result.
Generators with standard equipment transport wheels must be operated with the
wheels and stands installed to provide air space between the ground and the
generator air intake. This prevents fuel, dirt, or debris from being drawn into the
generator air intake, which can cause generator or engine damage.
Operating the generator without the
wheel kit installed can pinch or block air
vent tubes or fuel drain tubes, causing
fuel to spill on the ground or, inside or
around the generator.
Spilled fuel can cause a fire and you can
be burned or seriously injured.
Always operate the generator with the
wheel kit installed and do not modify
any part of the generator, including air,
drain and fuel tubes, or covers, panels
and air intakes.
BATTERY MAINTENANCE COVER
STAND
WHEEL
31Z376290-A.book 47 ページ 2025年10月24日 金曜日 午後2時44分

BEFORE OPERATION
48
AC Appliance and Power Cord
Before connecting an AC appliance or power cord to the generator:
• Use grounded 3-prong extension cords, tools, and appliances, or double-
insulated tools and appliances.
• Inspect cords and plugs, and replace if damaged.
• Do not use cord lengths greater than 164 feet (50 meters), and do not use
multiple tools and appliances with built-in noise filters. Such use may activate
the GFCI and interrupt power supply.
• Make sure that the appliance is in good working order. Faulty appliances or
power cords can create a potential for electric shock.
• Make sure the electrical rating of the tool or appliance does not exceed the
rated power of the generator or the receptacle being used.
• Do not exceed the current limit specified for any one receptacle.
31Z376290-A.book 48 ページ 2025年10月24日 金曜日 午後2時44分

BEFORE OPERATION
49
ENGINE OIL LEVEL CHECK
Check the engine oil level with the engine stopped and in a level position.
1. Open the right maintenance cover by turning its latch (see page 34).
2. Remove the oil filler cap by turning it counterclockwise. Wipe the dipstick
clean.
3. Insert the dipstick into the oil filler neck as shown, but do not screw it in, then
remove it to check the oil level.
4. If the oil level is near or below the lower limit, fill with the recommended oil
to the upper limit. Do not overfill.
• "Upper limit" means the oil exists to the oil filler neck.
• "Lower limit" means the oil only shows at the lower end of the dipstick.
Refer to "ENGINE OIL RECOMMENDATIONS" on page 20.
5. Reinstall the oil filler cap securely.
6. Close the right maintenance cover by turning its latch (see page 34).
The Oil Alert system will automatically stop the engine before the oil level falls
below safe limits. However, to avoid the inconvenience of an unexpected
shutdown, check the oil level regularly.
OIL FILLER NECK
OIL FILLER CAP
UPPER LIMIT
(The oil exists to the
oil filler neck.)
LOWER LIMIT
(The oil only shows at
the lower end of the
dipstick.)
DIPSTICK
31Z376290-A.book 49 ページ 2025年10月24日 金曜日 午後2時44分

BEFORE OPERATION
50
AIR FILTER CHECK
1. Open the left maintenance cover by turning its latch counterclockwise.
2. Unsnap the air cleaner cover clips; remove the air cleaner cover.
3. Foam air filter:
a. Remove the foam air filter from the air cleaner cover.
b. Check the form air filter to be sure it is clean and in good condition.
If the form air filter is dirty, clean it as described on page 78.
Replace the form air filter if it is damaged.
c. Reinstall the form air filter in the air cleaner cover.
4. Paper air filter:
a. Remove the guide.
b. If the paper air filter is dirty, replace it with a new one.
Do not clean the paper air filter.
5. Reinstall the guide and the air cleaner cover.
6. Close the left maintenance cover.
Operating the engine without the air filters, or with damaged air filters, will allow
dirt to enter the engine, causing rapid engine wear. This type of damage is not
covered by the Distributor’s Limited Warranty.
PAPER AIR FILTER
AIR CLEANER COVER
CLIP
GUIDE
FOAM AIR FILTER
31Z376290-A.book 50 ページ 2025年10月24日 金曜日 午後2時44分

BEFORE OPERATION
51
SAFE OPERATING PRECAUTIONS
Before operating the generator, review chapters "GENERATOR SAFETY" (see
page 7).
For your safety, do not operate the generator in an enclosed, or partly enclosed
area such as a garage (even if the door is open) or near structures or vehicles.
Your generator's exhaust contains poisonous carbon monoxide gas that can
collect rapidly in such areas, structures, vehicles, trailers, or boats.
• Do not operate the generator when it is in a storage, cargo, or security
enclosure, including any RV generator bay.
• Always completely remove the generator from the vehicle, trailer, boat or
other equipment or structure during operation.
• The generator must remain stationary while in operation.
Exhaust contains poisonous carbon
monoxide gas that can build up to
dangerous levels in enclosed or partly
enclosed areas.
Breathing carbon monoxide can cause
unconsciousness or death.
Never run this product's engine in an
enclosed, or even partly enclosed area.
31Z376290-A.book 51 ページ 2025年10月24日 金曜日 午後2時44分

52
OPERATION
STARTING THE ENGINE
To prevent a possible fire, keep the generator at least 3 feet (1 meter) away from
building or trailer walls, vehicles, trailers, boats, and other equipment during
operation. Do not place flammable objects close to the engine or exhaust.
• Operating this generator less than 3 feet (1 meter) from a building, obstruction, or
when it is in an enclosure, a storage or security compartment/bay, can cause
overheating and damage the generator.
• For proper cooling, allow at least 3 feet (1 meter) of empty space above and
around the generator.
Keep all cooling holes open and clear of debris, mud, water, etc. Cooling holes are
located on the control panel and the bottom of the generator. If the cooling holes
are blocked, the generator may overheat and damage the engine, inverter, or
windings.
• Since the CO-MINDER® may detect the carbon monoxide concentration and the
engine may stop automatically, pay attention to the direction of exhaust and
where the generator is located (see page 28).
Refer to "SAFE OPERATING PRECAUTIONS" on page 51 and perform the "IS
YOUR GENERATOR READY TO GO?" checks (see page 45).
Refer to "AC OPERATION" (see page 60) for connecting loads to the generator.
1. Make sure that all appliances are
disconnected from the AC
receptacles.
2. Set the Voltage Selector Switch to
match the voltage requirements for
the application.
VOLTAGE SELECTOR SWITCH
120 V/240 V
120 V ONLY
31Z376290-A.book 52 ページ 2025年10月24日 金曜日 午後2時44分

OPERATION
53
3. Make sure the Eco Throttle switch is
in the OFF position, or more time
will be required for warm-up.
If you wish to use the Eco Throttle
system, turn the Eco Throttle switch
to the ON position after the engine
has warmed up for 2 or 3 minutes.
4. Turn the MAIN switch to the ON
position.
5. Press and release the ENGINE START
button.
The ENGINE START button functions
for 5 seconds. As soon as the engine
starts, the starter will stop
automatically.
If the engine fails to start, wait at
least 10 seconds before operating
the starter again.
Do not leave the MAIN switch in the ON position when the generator is not
operating or the battery will be drained. Turn the MAIN switch to the OFF
position when not in use.
If the MAIN switch is left in the ON position without starting the engine within
30 minutes, the ENGINE START button will not function.
• To restart the engine using the ENGINE START button, the MAIN switch
must be turned to the OFF position, and then back to the ON position.
• If the MAIN switch is left on longer than 30 minutes, the engine will still
start using a Bluetooth® enabled smartphone.
ON
OFF
ECO THROTTLE SWITCH
MAIN SWITCH
ENGINE START BUTTON
ON
OFF
31Z376290-A.book 53 ページ 2025年10月24日 金曜日 午後2時44分

OPERATION
54
• Use the recoil starter when the
battery voltage is too low to turn
the starter motor.
a. Turn the MAIN switch to the
ON position.
b. Open the right maintenance
cover by turning its latch
counterclockwise.
c. Pull the starter grip lightly until
you feel resistance; then pull
briskly in the direction of the
arrow as shown.
• Do not exceed 20 degrees
from horizontal when pulling
the starter grip or the starter
rope may become damaged.
• Do not allow the starter grip
to snap back against the
engine. Return it gently to
prevent damage to the
starter.
• Do not let the starter rope rub
against the generator body,
or the rope will wear out
prematurely.
d. Close the right maintenance
cover by turning its latch
clockwise.
6. If you wish to use the Eco Throttle
system, turn the Eco Throttle switch
to the ON position after the engine
has warmed up for 2 or 3 minutes.
MAIN SWITCH
ON
20°
STARTER GRIP
ECO THROTTLE SWITCH
OFF
ON
OFF
31Z376290-A.book 54 ページ 2025年10月24日 金曜日 午後2時44分

OPERATION
55
STOPPING THE ENGINE
1. Turn off or disconnect all appliances or devices that are connected to the
generator.
2. Turn the MAIN switch to the OFF position. For additional safety, remove the
key from the MAIN switch.
3. Unplug all appliances from the generator AC receptacles.
4. If two generators were connected for parallel operation, disconnect the
parallel operation cable after stopping the engines if you do not wish to
resume parallel operation.
MAIN SWITCH
ON
OFF
KEY
PARALLEL KIT
(optional equipment)
31Z376290-A.book 55 ページ 2025年10月24日 金曜日 午後2時44分

OPERATION
56
STARTING AND STOPPING THE ENGINE with Bluetooth® ENABLED
SMARTPHONE
The engine can be started/stopped via a Bluetooth® enabled smartphone using
a Bluetooth® application.
Refer to the Bluetooth® application to check the connection, operation, and for
help pairing a smartphone.
HOW TO RESTART WHEN STOPPED BY CO-MINDER® (CO SHUT-OFF SYSTEM)
When the engine is automatically stopped by the CO-MINDER®, move the
generator to an area with fresh air and away from any device that may be
emitting carbon monoxide, such as another generator. Press the CO-MINDER
reset button and then follow the standard procedure for starting the engine.
When the CO ALARM indicator or the FAULT/CO-MINDER LIFE indicator flashes,
press the CO-MINDER reset button to turn off the indicator.
However, even if the CO-MINDER reset button is pressed and the CO ALARM
indicator turns off, the engine cannot be started remotely using the Bluetooth®
connection unless the engine is started using the ENGINE START button on the
control panel once.
CO-MINDER® RESET BUTTON CO ALARM INDICATOR
FAULT/CO SENSOR LIFE INDICATOR
31Z376290-A.book 56 ページ 2025年10月24日 金曜日 午後2時44分

OPERATION
57
GFCI OPERATION CHECK
Always check GFCI operation before using the generator.
A faulty GFCI system will not provide
proper protection against electric shock
as designed.
An electric shock can result in serious
injury or death.
Always perform the GFCI system
inspection before using the generator. If
the GFCI system fails the test, the
generator must be repaired by your
servicing dealer before use.
GFCI RECEPTACLES
(120 V 20 A DUPLEX RECEPTACLES)
31Z376290-A.book 57 ページ 2025年10月24日 金曜日 午後2時44分

OPERATION
58
1. Unplug all tools and appliances from the generator.
2. Start the engine (see page 52).
When the GFCI is operating normally, the GFCI indicator will continuously
light green.
Light order:
(red) Blink once (green) Lights continuously
• If the green GFCI indicator does not come on, press the GFCI RESET button.
• If the red GFCI indicator starts to blink continuously, contact an authorized
Honda Power Equipment dealer.
3. Press the GFCI TEST button:
• The GFCI RESET button will pop out and the green GFCI indicator will go
off.
• If the GFCI does not function as described, contact an authorized Honda
Power Equipment dealer.
GFCI RESET BUTTON
GFCI INDICATOR
GFCI TEST BUTTON
31Z376290-A.book 58 ページ 2025年10月24日 金曜日 午後2時44分

OPERATION
59
4. Press the GFCI RESET button:
• The green GFCI indicator will light continuously.
• If the red GFCI indicator starts to blink continuously, contact an authorized
Honda Power Equipment dealer.
When the GFCI RESET button pops out or the green GFCI indicator does not
light during operation:
• Unplug all appliances from the GFCI protected receptacle.
• Press the GFCI RESET button.
– If the GFCI cannot be reset, the GFCI is faulty. Contact an authorized
Honda Power Equipment dealer.
– If the GFCI RESET button extends, this usually indicates a faulty power
tool, appliance, or cord. If that occurs, perform operation check steps 1
through 4 to verify that the GFCI is in proper working order. If the GFCI
tests correctly, then the fault is likely to be in the power tool, appliance,
or cord. Repair or replace the faulty power tool, appliance, or cord before
further use.
GFCI RESET BUTTON
GFCI INDICATOR
31Z376290-A.book 59 ページ 2025年10月24日 金曜日 午後2時44分

OPERATION
60
AC OPERATION
If an appliance begins to operate abnormally, becomes sluggish, or stops
suddenly, turn it off immediately. Disconnect the appliance, and determine
whether the problem is in the appliance or the rated load capacity of the
generator has been exceeded.
• Substantial overloading that continuously lights the red OVERLOAD ALARM
indicator may damage the generator. Marginal overloading that temporarily
lights the red OVERLOAD ALARM indicator may shorten the service life of the
generator.
• Be sure that all appliances are in good working order before connecting them to
the generator. Electrical equipment (including lines and plug connections) should
not be defective. If an appliance begins to operate abnormally, becomes sluggish,
or stops suddenly, turn the MAIN switch to OFF position immediately. Then
disconnect the appliance, and examine it for signs of malfunction.
1. Turn the voltage selector switch to either position.
With the voltage selector switch in the "120 V/240 V" position, you can use
the 120 V and 120 V/240 V receptacles simultaneously. If you are NOT using
the 120 V/240 V receptacle, then select the "120 V ONLY" position.
2. Start the engine and make sure
the green OUTPUT indicator
comes on.
3. Make sure the AC circuit
protectors are ON (see page 31).
120 V/240 V
VOLTAGE SELECTOR SWITCH
120 V ONLY
OUTPUT INDICATOR (GREEN)
31Z376290-A.book 60 ページ 2025年10月24日 金曜日 午後2時44分

OPERATION
61
4. Plug in the appliance.
Most motorized appliances require more than their rated wattage for startup.
5. Turn on the appliance.
If the generator is overloaded, or if there is a short circuit in a connected
appliance, or if the inverter is overheated, the red OVERLOAD ALARM indicator
will come ON. The red OVERLOAD ALARM indicator will stay ON and, after about
five seconds, current to the connected appliance(s) will shut off, and the green
OUTPUT indicator will go OFF. Stop the engine and investigate the problem.
Determine if the cause is a short circuit in a connected appliance, an overload,
or an overheated inverter. Correct the problem and restart the generator.
Before connecting an appliance to the generator, make sure that it is in good
order and that its electrical rating does not exceed that of the generator. Then
start the generator and connect the appliance power cord.
When an electric motor is started, the red OVERLOAD ALARM indicator may
come on. This is normal if the red OVERLOAD ALARM indicator goes OFF after
about five seconds. If the red OVERLOAD ALARM indicator stays ON, consult an
authorized Honda Power Equipment dealer.
PLUG
31Z376290-A.book 61 ページ 2025年10月24日 金曜日 午後2時44分

OPERATION
62
AC Applications
Before connecting an appliance or power cord to the generator:
• Make sure that it is in good working order. Faulty appliances or power cords
can create a potential for electrical shock.
• If an appliance begins to operate abnormally, becomes sluggish, or stops
suddenly, turn it off immediately. Disconnect the appliance, and determine
whether the problem is the appliance or the rated load capacity of the
generator has been exceeded.
Most appliance motors require more than their rated wattage for startup.
Make sure the electrical rating of the tool or appliance does not exceed the
maximum power rating of the generator.
Maximum power is:
7.0 kVA
For continuous operation, do not exceed the rated power.
Rated power is:
5.5 kVA
In either case, the total power requirements (VA) of all appliances connected
must be considered. Appliance and power tool manufacturers usually list rating
information near the model number or serial number.
Substantial overloading will open the circuit protector. Slightly overloading the
generator may not switch the circuit protector OFF, but will shorten the service life of
the generator.
31Z376290-A.book 62 ページ 2025年10月24日 金曜日 午後2時44分

OPERATION
63
AC Receptacle Selection
The control panel, shown below, has a voltage selector switch and four
receptacles. Receptacle 4, the 240-volt receptacle, has two powered terminals,
4A and 4B.
Power Producing Circuits
This generator is equipped with two power generating circuits. When the
voltage selector switch is in the 120 V/240 V position, each of the two power
producing circuits supplies power to specific receptacles. When the voltage
selector switch is in the 120 V ONLY position, the power producing circuits
operate in parallel, sharing the total load connected to terminal 4A and
receptacles 1, 2, and 3.
RECEPTACLE
GFCI RECEPTACLE
(120 V 20 A DUPLEX RECEPTACLE)
RECEPTACLE
TERMINAL
TERMINAL
RECEPTACLE
VOLTAGE SELECTOR SWITCH
RECEPTACLE
GFCI RECEPTACLE
(120 V 20 A DUPLEX RECEPTACLE)
]
[
[
]
POWER CIRCUIT 2
POWER CIRCUIT 1
120 V/240 V 120 V ONLY
POWER
CIRCUIT 1
POWER
CIRCUIT 2
31Z376290-A.book 63 ページ 2025年10月24日 金曜日 午後2時44分

OPERATION
64
Voltage Selector Switch
Disconnect or turn OFF all appliances or tools connected to the generator before
changing the voltage selector switch position.
The generator may be damaged if the switch position is changed with loads
connected and operating.
The power available to each receptacle depends on the position of the voltage
selector switch.
120 V ONLY POSITION
When the voltage selector switch is in the 120 V ONLY position, you do not need
to spread the load over the receptacles. You must, however, make sure the load
on any receptacle does not exceed its available power shown in the preceding
table and the total load does not exceed 45.8 amps.
120 V/240 V POSITION
When the voltage selector switch is in the 120 V/240 V position, you must
balance the load. Divide the load between the two sets of receptacles shown
below. Balancing is necessary because each set of receptacles is powered by
only one power producing circuit that can produce a maximum of 22.9 amps.
Switch Position Receptacle Available Power
120 V ONLY 30 A at 120 V
20 A at 120 V
20 A at 120 V
30 A at 120 V
None
120 V/240 V 22.9 A at 120 V
20 A at 120 V
20 A at 120 V
-
22.9 A at 240 V
Set of
Receptacles
Total Current
Available
Power Producing
Circuit
+ +
22.9 A 1
+
22.9 A 2
31Z376290-A.book 64 ページ 2025年10月24日 金曜日 午後2時44分

OPERATION
65
AC PARALLEL OPERATION
Before connecting an appliance to either generator, make sure that the
appliance is in good working order and that its electrical rating does not exceed
that of the receptacle.
Most motorized appliances require more than their electrical rating for startup.
When an electric motor is started, the OVERLOAD ALARM indicator (red) may
come ON. This is normal if the OVERLOAD ALARM indicator (red) goes OFF
within 5 seconds. If the OVERLOAD ALARM indicator (red) stays ON, consult your
generator dealer.
During parallel operation, the Eco Throttle switch should be in the same
position on both generators.
1. Install the parallel kit on the frame of one generator.
Connect the parallel operation cable between two EU7000iS generators
following the instructions supplied with the parallel kit.
2. Set the voltage selector switch of both generators to 120 V/240 V.
PARALLEL KIT
(optional equipment)
VOLTAGE SELECTOR SWITCH
120 V/240 V
31Z376290-A.book 65 ページ 2025年10月24日 金曜日 午後2時44分

OPERATION
66
3. Start the engine on each generator and make sure each OUTPUT indicator
(green) comes ON.
4. Turn the AC circuit protector of the parallel operation box ON.
5. Plug in the appliance following the instructions provided with the parallel kit.
6. Turn on the appliance.
If the generators are overloaded (see page 69), or if there is a short circuit in a
connected appliance, the OVERLOAD ALARM indicators (red) will come ON. The
OVERLOAD ALARM indicators (red) will stay ON and after about five seconds,
current to the connected appliance(s) will shut off, and the OUTPUT indicators
(green) will go OFF. Stop both engines and investigate the problem.
Determine if the cause is a short circuit in a connected appliance or an overload.
Correct the problem and restart the generators.
AC CIRCUIT PROTECTORS
RECEPTACLE
31Z376290-A.book 66 ページ 2025年10月24日 金曜日 午後2時44分

OPERATION
67
AC Parallel Operation Applications
Two EU7000iS generators can be connected together to increase the available
power using a parallel kit (optional equipment).
Follow the instructions included with the parallel kit.
Before connecting an appliance or power cord to the generator:
• Make sure that it is in good working order. Faulty appliances or power cords
can create a potential for electrical shock.
• If an appliance begins to operate abnormally, becomes sluggish, or stops
suddenly, turn it off immediately. Disconnect the appliance, and determine
whether the problem is the appliance or the rated load capacity of the
generator has been exceeded.
• Never connect different generator models.
• For parallel operation, use only a Honda approved parallel kit (optional
equipment) when connecting one EU7000iS to another EU7000iS generator.
• Never connect or remove the parallel operation cable when the generator is
running.
• For single generator operation, the parallel operation cable must be
disconnected from both generators.
31Z376290-A.book 67 ページ 2025年10月24日 金曜日 午後2時44分

OPERATION
68
When operating generators in parallel operation, if one generator emits exhaust
toward the other, the CO-MINDER® (CO Shut-off System) of the generator that is
receiving the exhaust may stop the engine. Pay attention to the following for
placing generators in parallel operation.
• Align the two generators so that their mufflers are on the same line and their
exhaust in the same direction.
• Place the generator so that the muffler is pointed in the same direction as the
wind is blowing and the exhaust is directed away from buildings, other structures,
or vehicles.
EXHAUST
EXHAUST
ON THE SAME LINE
MUFFLER TIP
WIND DIRECTION
WIND DIRECTION
This generator may detect exhaust from
the adjacent generator and will stop the
engine.
OK INCORRECT
31Z376290-A.book 68 ページ 2025年10月24日 金曜日 午後2時44分

OPERATION
69
Most appliance motors require more than their rated wattage for startup.
Make sure the electrical rating of the tool or appliance does not exceed the
maximum power rating of the generator.
Maximum power in parallel operation is:
12.0 kVA
For continuous operation, do not exceed the rated power.
Rated power in parallel operation is:
11.0 kVA
In either case, the total power requirements (VA) of all appliances connected
must be considered. Appliance and power tool manufacturers usually list rating
information near the model number or serial number.
Substantial overloading that continuously lights the red OVERLOAD ALARM
indicator may damage the generator. Marginal overloading that temporarily lights
the red OVERLOAD ALARM indicator may shorten the service life of the generator.
31Z376290-A.book 69 ページ 2025年10月24日 金曜日 午後2時44分

OPERATION
70
ECO THROTTLE® SYSTEM
With the switch in the ON position, engine speed is automatically lowered when
loads are reduced, turned off, or disconnected. When appliances are turned on
or reconnected, the engine returns to the proper speed to power the electrical
load. In the OFF position, the Eco Throttle system does not operate.
Appliances with large start-up power demands may not allow the engine to
reach normal operating rpm when they are connected to the generator. Turn
the Eco Throttle switch to the OFF position and connect the appliance to the
generator. If the engine still will not reach normal operating speed, check that
the appliance does not exceed the rated load capacity of the generator.
If high electrical loads are connected simultaneously, turn the Eco Throttle
switch to the OFF position to reduce voltage changes.
The Eco Throttle system is not effective for use with appliances or tools that
require only momentary power. If the tool or appliance will be turned ON and
OFF quickly, the Eco Throttle switch should be in the OFF position.
ECO THROTTLE SWITCH
OFF
ON
31Z376290-A.book 70 ページ 2025年10月24日 金曜日 午後2時44分

OPERATION
71
STANDBY POWER
Connections to a Building’s Electrical System
Connections for standby power to a building’s electrical system must be made
by a qualified electrician. The connection must isolate the generator power
from utility power, and must comply with all applicable laws and electrical
codes.
In some areas, generators are required by law to be registered with local utility
companies. Check local regulations for proper registration and use procedures.
System Ground
This generator has a system ground that connects generator frame components
to ground terminals in the AC output receptacles. The system ground is not
connected to the AC neutral wire.
Improper connections to a building’s
electrical system can allow current from
the generator to backfeed into the
utility lines.
Such backfeed may electrocute utility
company workers or others who contact
the lines during a power outage, and the
generator may explode, burn, or cause
fires when utility power is restored.
Consult the utility company or a
qualified electrician prior to making any
power connections.
31Z376290-A.book 71 ページ 2025年10月24日 金曜日 午後2時44分

OPERATION
72
Special Requirements
Do not lay the generator on its side when moving, storing, or operating it. Oil and
fuel may leak and damage the engine or your property.
There may be Federal or State Occupational Safety and Health Administration
(OSHA) regulations, local codes, or ordinances that apply to the intended use of
the generator. Please consult a qualified electrician, electrical inspector, or the
local agency having jurisdiction.
• In some areas, generators are required to be registered with local utility
companies.
• If the generator is used at a construction site, there may be additional
regulations that must be observed.
31Z376290-A.book 72 ページ 2025年10月24日 金曜日 午後2時44分

73
SERVICING YOUR GENERATOR
THE IMPORTANCE OF MAINTENANCE
Good maintenance is essential for safe, economical, and trouble-free operation.
It will also help reduce air pollution.
To help you properly care for your generator, the following pages include a
maintenance schedule, routine inspection procedures, and simple maintenance
procedures using basic hand tools. Other service tasks that are more difficult or
require special tools are best handled by professionals and are normally
performed by a Honda technician or other qualified mechanic.
The maintenance schedule applies to normal operating conditions. If you
operate your generator under unusual conditions, such as sustained high-load
or high-temperature operation, or use it in dusty conditions, consult your
servicing dealer for recommendations applicable to your individual needs and
use.
Remember that an authorized Honda Power Equipment dealer knows your
generator best and is fully equipped to maintain and repair it.
To ensure the best quality and reliability, use only new, Honda Genuine parts or
their equivalents for repair and replacement.
Maintenance, replacement, or repair of the emission control devices and
systems may be performed by any engine repair establishment or
individual, using parts that are "certified" to EPA standards.
Failure to properly maintain this
generator, or failing to correct a problem
before operation, could result in a
significant malfunction.
Some malfunctions can cause serious
injuries or death.
Always follow the inspection and
maintenance recommendations and
schedules in this owner’s manual.
31Z376290-A.book 73 ページ 2025年10月24日 金曜日 午後2時44分

SERVICING YOUR GENERATOR
74
MAINTENANCE SAFETY
Some of the most important safety precautions follow. However, we cannot
warn you of every conceivable hazard that can arise in performing
maintenance. Only you can decide whether or not you should perform a given
task.
Safety Precautions
Read the instructions before you begin, and make sure you have the tools and
skills required.
• Make sure the engine is off before you begin any maintenance or repairs. This
will eliminate several potential hazards:
– Carbon monoxide poisoning from engine exhaust
Operate outside away from open windows or doors with engine exhaust
directed away from occupied structures.
– Burns from hot parts
Let the engine and exhaust system cool before touching.
– Injury from moving parts
Do not run the engine unless instructed to do so.
• To reduce the possibility of fire or explosion, be careful when working around
gasoline. Use only a non-flammable solvent, not gasoline, to clean parts. Keep
cigarettes, sparks, and flames away from all fuel-related parts.
Improper maintenance can cause an
unsafe condition.
Failure to properly follow maintenance
instructions and precautions can cause
serious injuries or death.
Always follow the procedures and
precautions in this owner’s manual.
31Z376290-A.book 74 ページ 2025年10月24日 金曜日 午後2時44分

SERVICING YOUR GENERATOR
75
MAINTENANCE SCHEDULE
Failure to follow this maintenance schedule could result in non-warrantable
failures.
NOTE:
(*) Replace paper air filter only.
(1) Service more frequently when used in dusty areas.
(2) These items should be serviced by your servicing dealer, unless you have the proper tools and are
mechanically proficient. Refer to the Honda shop manual for service procedures. See "Honda
PUBLICATIONS" on page 107 for ordering information.
(3) For commercial use, log hours of operation to determine proper maintenance intervals.
This generator is equipped with a catalytic converter. If the engine is not properly maintained, the catalyst in
the muffler may lose effectiveness.
REGULAR SERVICE PERIOD (3)
ITEM
Perform at every indicated month or
operating hour interval, whichever comes
first.
Each
use
First
month
or
20 hrs.
Every
3 months
or
50 hrs.
Every
6 months
or
100 hrs.
Every
year
or
300 hrs.
Page
Engine oil Check level o 49
Change o o 76
Air cleaner Check o 50
Clean o (1) 78
Replace o (*) 50
GFCI operation Check o 57
Canister Check
Every 2 years (2)
—
Purge tube Check —
Charge tube Check —
Air tube
(AC1 type only)
Check —
Purge control solenoid valve
(AC1 type only)
Check —
Fuel tank cap tether
(AC1 type only)
Check —
Spark plug Check-adjust o 79
Replace o
Spark arrester Clean o 81
Valve clearance Check-adjust o (2) —
Combustion chamber Clean After every 1,000 hrs. (2) —
Fuel tank Clean
Every 2 years or 1,000 hrs. (2)
—
Fuel pump filter Change —
Fuel tube Check Every 2 years (Replace if necessary) (2) —
31Z376290-A.book 75 ページ 2025年10月24日 金曜日 午後2時44分

SERVICING YOUR GENERATOR
76
ENGINE OIL CHANGE
Drain the oil while the engine is warm to assure rapid and complete draining.
1. Open the right maintenance cover by turning its latch (see page 34).
2. Reach under the generator and remove the black rubber seal located below
the oil drain plug.
3. Place a suitable container underneath the generator to catch the used oil.
4. Remove the oil filler cap.
5. Remove the oil drain plug and sealing washer and allow the oil to drain
completely.
6. Reinstall the oil drain plug and a new sealing washer. Tighten the plug
securely.
Torque: 16.3 lbf·ft (22.5 N·m, 2.25 kgf·m)
7. Reach under the generator and reinstall the black rubber seal.
Improper disposal of engine oil can be harmful to the environment.
If you change your own oil, please dispose of the used oil properly. Do not discard
it in a trash bin, dump it on the ground, or pour it down the drain.
31Z376290-A.book 76 ページ 2025年10月24日 金曜日 午後2時44分

SERVICING YOUR GENERATOR
77
8. With the generator in a level position, fill with the recommended oil to the
upper limit. Do not overfill.
• "Upper limit" means the oil exists to the oil filler neck.
Refer to "ENGINE OIL RECOMMENDATIONS" on page 20.
Maximum oil capacity: 1.2 US qt (1.1 L)
9. Reinstall the oil filler cap securely.
10. Close the right maintenance cover by turning its latch (see page 34).
Wash your hands with soap and water after handling used oil.
BLACK RUBBER SEAL
SEALING WASHER
(Replace)
OIL FILLER CAP
OIL DRAIN PLUG
UPPER LIMIT
(The oil exists to the
oil filler neck.)
31Z376290-A.book 77 ページ 2025年10月24日 金曜日 午後2時44分

SERVICING YOUR GENERATOR
78
AIR CLEANER SERVICE
Foam Air Filter Cleaning
A dirty foam air filter will restrict air flow to the fuel system, reducing engine
performance. If you operate the generator in very dusty areas, clean the foam
air filter more frequently than specified in the Maintenance Schedule.
1. Clean the foam air filter in warm soapy water, rinse, and allow to dry
thoroughly, or clean in non-flammable solvent and allow to dry.
2. Dip the foam air filter in clean engine oil, and then squeeze out all excess oil.
The engine will smoke when started if too much oil is left in the filter.
3. Wipe dirt from the inside of the air cleaner cover using a moist rag. Be careful
to prevent dirt from entering the air duct that leads to the fuel system.
Clean Squeeze and dry
Do not twist.
Dip in oil
Squeeze
Do not twist.
31Z376290-A.book 78 ページ 2025年10月24日 金曜日 午後2時44分

SERVICING YOUR GENERATOR
79
SPARK PLUG SERVICE
In order to service the spark plug, you will need a spark plug wrench
(commercially available).
Required spark plug: BPR6ES (NGK)
To ensure proper engine operation, the spark plug must be properly gapped
and free of deposits.
An incorrect spark plug can cause engine damage.
If the engine is hot, allow it to cool before servicing the spark plug.
1. Open the left maintenance cover by turning its latch counterclockwise.
2. Loosen the cover screw and remove the spark plug inspection cover.
3. Disconnect the spark plug cap, and remove any dirt from around the spark
plug area.
4. Remove the spark plug with a spark plug wrench.
COVER SCREW
SPARK PLUG INSPECTION COVER
SPARK PLUG WRENCH
SPARK PLUG CAP
31Z376290-A.book 79 ページ 2025年10月24日 金曜日 午後2時44分

SERVICING YOUR GENERATOR
80
5. Inspect the spark plug. Replace it if
the electrodes are worn or fouled,
or if the insulator is cracked or
chipped. Clean the spark plug with
a wire brush if it is to be reused.
6. Measure the spark plug electrode
gap with a wire-type feeler gauge.
Correct the gap, if necessary, by
carefully bending the side
electrode.
Spark plug gap:
0.028–0.031 in (0.7–0.8 mm)
7. Make sure that the spark plug sealing washer is in good condition, and thread
the spark plug in by hand to prevent cross-threading.
8. After the spark plug is seated, tighten with a spark plug wrench to compress
the washer.
If reinstalling a used spark plug, tighten 1/8–1/4 turn after the spark plug is
seated.
If installing a new spark plug, tighten 1/2 turn after the spark plug is seated.
Torque: 13.0 lbf·ft (18 N·m, 1.8 kgf·m)
A loose spark plug can overheat and damage the engine.
Overtightening the spark plug can damage the threads in the cylinder head.
9. Attach the spark plug cap.
10. Reinstall the spark plug inspection cover and tighten the cover screw.
11. Close the left maintenance cover.
SEALING WASHER
0.028–0.031 in
(0.7–0.8 mm)
SIDE ELECTRODE
INSULATOR
31Z376290-A.book 80 ページ 2025年10月24日 金曜日 午後2時44分

SERVICING YOUR GENERATOR
81
SPARK ARRESTER SERVICE
The spark arrester must be serviced every 100 hours to keep it functioning as
designed.
If the engine has been running, the muffler will be very hot. Allow the muffler to
cool before servicing the spark arrester.
1. Remove the two 5 × 16 mm pan head screws, and remove the tail pipe and
spark arrester.
2. Use a brush to remove carbon deposits from the spark arrester screen.
Be careful to avoid damaging the screen.
The spark arrester must be free of breaks and tears. Replace the spark arrester
if it is damaged.
3. Install the spark arrester in the reverse order of removal.
TAIL PIPE
SPARK ARRESTER
5 × 16 mm PAN HEAD SCREW (2)
31Z376290-A.book 81 ページ 2025年10月24日 金曜日 午後2時44分

SERVICING YOUR GENERATOR
82
BATTERY SERVICE
Your generator’s engine charging system charges the battery while the engine
is running. However, if the generator is only used periodically, the battery must
be charged monthly to maintain the battery service life.
Emergency Procedures
Eyes – Wash your eye(s) with plenty of water avoiding damaging your eye(s)
with water pressure. Call your local Poison Center or a doctor immediately.
Skin – Remove contaminated clothing. Wash the skin with large quantities of
water. Call your local Poison Center or a doctor immediately.
Swallowing – Wash mouth with a large amount of water and drink a cup of
water. Call your local Poison Center or a doctor immediately.
The battery contains sulfuric acid
(electrolyte), which is highly corrosive
and poisonous.
Getting electrolyte in your eyes or on
your skin can cause serious burns.
Wear protective clothing and eye
protection when working near the
battery.
31Z376290-A.book 82 ページ 2025年10月24日 金曜日 午後2時44分

SERVICING YOUR GENERATOR
83
Battery Removal
WARNING: Battery posts, terminals, and related accessories contain lead and
lead compounds. Wash your hands after handling.
1. Lift the handle upward. The lock levers will lock and secure the handle in
place.
The battery gives off explosive
hydrogen gas during normal operation.
A spark or flame can cause the battery to
explode with enough force to kill or
seriously hurt you.
Wear protective clothing and a face
shield, or have a skilled mechanic
perform the battery maintenance.
HANDLE
HANDLE LOCK LEVER
31Z376290-A.book 83 ページ 2025年10月24日 金曜日 午後2時44分

SERVICING YOUR GENERATOR
84
2. Loosen the cover screw and remove the battery maintenance cover.
3. Remove the negative (–) cable from the battery negative (–) terminal, and
then remove the positive (+) cable from the battery positive (+) terminal.
4. Unhook the battery strap from the bottom hook of the generator.
COVER SCREW
BATTERY MAINTENANCE COVER
BATTERY STRAP
NEGATIVE (–) CABLE
POSITIVE (+) CABLE
31Z376290-A.book 84 ページ 2025年10月24日 金曜日 午後2時44分

SERVICING YOUR GENERATOR
85
5. Remove the battery.
This symbol on the battery means that this product must not be
treated as household waste.
An improperly disposed of battery can be harmful to the environment and
human health.
Always confirm local regulations for battery disposal.
Battery Charging
The battery is rated at 11.2 Ah (ampere-hours). Charging current should equal
10% of the battery’s ampere-hour rating. A battery charger should be used that
can be adjusted to deliver 1.1 ampere.
Battery: 12 V 11.2 Ah (10 HR)
1. Connect the battery charger following the manufacturer’s instructions.
2. Charge the battery 5—10 hours.
3. Clean the outside of the battery and the battery tray compartment with a
solution of baking soda and water.
Battery Installation
1. Install the battery into the generator.
2. Connect the battery positive (+) cable to the battery positive (+) terminal first,
and tighten the bolt securely.
3. Slide the battery boot over the positive (+) cable and terminal.
4. Connect the battery negative (–) cable to the battery negative (–) terminal,
and tighten the bolt securely.
5. Install the battery strap.
6. Install the battery maintenance cover in the reverse order of removal (see
page 83).
Never operate the generator without the battery cover in place, as poor engine
and generator performance will result.
31Z376290-A.book 85 ページ 2025年10月24日 金曜日 午後2時44分

SERVICING YOUR GENERATOR
86
FUSE
If the fuse is blown, the starter motor will not work.
In the event of fuse failure, locate the cause of failure and repair it before you
continue operation. If the fuse continues to fail, discontinue generator use and
consult your authorized Honda Power Equipment dealer.
1. Turn the MAIN switch to the OFF position and remove the key before
checking or replacing the fuse.
2. Loosen the cover screw and
remove the battery maintenance
cover.
3. Remove the fuse holder cover and
pull the fuse out.
4. Replace the fuse with a fuse of the
same type and rating.
Specified fuse: 3 A, 15 A
Never use a fuse with a different
rating from that specified. Serious
damage to the electrical system or
fire may result.
5. Install the fuse holder cover and the battery maintenance cover in the reverse
order of removal.
Never operate the generator without the battery maintenance cover in place, as
poor engine and generator performance will result.
BATTERY MAINTENANCE COVER
COVER
SCREW
FUSE (15 A) FUSE (3 A)
FUSE HOLDER COVER
31Z376290-A.book 86 ページ 2025年10月24日 金曜日 午後2時44分

87
STORAGE
STORAGE PREPARATION
Proper storage preparation is essential for keeping your generator trouble-free
and looking good. The following steps will help to keep rust and corrosion from
impairing your generator’s function and appearance, and will make the engine
easier to start when you use the generator again.
Cleaning
Wipe the generator with a moist cloth. After the generator has dried, touch up
any damaged paint, and coat other areas that may rust with a light film of oil.
Fuel
Depending on the region where you operate your equipment, fuel formulations may
deteriorate and oxidize rapidly. Fuel deterioration and oxidation can occur in as
little as 30 days and may cause damage to the fuel system. Please check with your
servicing dealer for local storage recommendations.
Gasoline will oxidize and deteriorate in storage. Old gasoline will cause hard
starting, and it leaves gum deposits that clog the fuel system. If the gasoline in
your generator deteriorates during storage, you may need to have the fuel
system components serviced or replaced.
The length of time that gasoline can be left in your fuel tank without causing
functional problems will vary with such factors as gasoline blend, your storage
temperatures, and whether the fuel tank is partly or completely filled. The air in
a partly filled fuel tank promotes fuel deterioration. Very warm storage
temperatures accelerate fuel deterioration. Fuel deterioration problems may
occur within a few months, or even less if the gasoline was not fresh when you
filled the fuel tank.
The Distributor’s Limited Warranty (U.S.) / Distributor’s Warranty (C.A.) does not
cover fuel system damage or engine performance problems resulting from
neglected storage preparation.
You can extend fuel storage life by adding a gasoline stabilizer that is
formulated for that purpose, or you can avoid fuel deterioration problems by
draining the fuel tank.
31Z376290-A.book 87 ページ 2025年10月24日 金曜日 午後2時44分

STORAGE
88
Service according to the table below:
STORAGE TIME RECOMMENDED SERVICE PROCEDURE TO
PREVENT HARD STARTING
Less than 1 month No preparation required.
1 month to 1 year Fill with fresh gasoline and add gasoline stabilizer*.
1 year or more Fill with fresh gasoline and add gasoline stabilizer*.
Remove the spark plug. Put a teaspoon of engine
oil into the cylinder. Turn the engine slowly with the
pull rope to distribute the oil.
Reinstall the spark plug.
Change the engine oil (see page 76).
After removal from storage, drain the stored
gasoline into a suitable container, and fill with fresh
gasoline before starting.
*
Use gasoline stabilizers that are formulated to extend storage life.
Follow the manufacturer’s instructions for use.
Contact your authorized Honda Power Equipment dealer for stabilizer
recommendations.
31Z376290-A.book 88 ページ 2025年10月24日 金曜日 午後2時44分

STORAGE
89
DRAINING THE FUEL TANK
Unscrew the fuel tank cap, remove the fuel strainer, and empty the fuel tank into
an approved gasoline container. We recommend using a commercially available
gasoline hand pump to empty the tank. Do not use an electric pump. Siphon
the gasoline by inserting the tip of the hand pump into the side of the pump
guard, as shown in the figure below. Reinstall the fuel strainer and the fuel tank
cap.
Gasoline is highly flammable and
explosive.
You can be burned or seriously injured
when handling fuel.
• Stop the engine and let it cool before
handling fuel.
• Keep heat, sparks, and flame away.
• Handle fuel only outdoors.
• Keep away from your vehicle.
• Wipe up spills immediately.
FUEL STRAINER
FUEL TANK CAP
HAND PUMP
PUMP GUARD
AN1 type
31Z376290-A.book 89 ページ 2025年10月24日 金曜日 午後2時44分

STORAGE
90
Engine Oil
Change the engine oil (see page 76).
Engine Cylinder
1. Remove the spark plug (see page 79).
2. Pour a teaspoon (5 cc) of clean engine oil into the cylinder.
3. Pull the starter rope several times to distribute the oil in the cylinder.
4. Reinstall the spark plug (see page 79).
5. Slowly pull the starter grip until resistance is felt. At this point, the piston is
coming up on its compression stroke and both the intake and exhaust valves
are closed. Storing the engine in this position will help to protect it from
internal corrosion. Return the starter grip gently.
Battery
Charge the battery before storing the generator (see page 85).
FUEL STRAINER
FUEL TANK CAP
HAND PUMP
PUMP GUARD
AC1 type
31Z376290-A.book 90 ページ 2025年10月24日 金曜日 午後2時44分

STORAGE
91
STORAGE PRECAUTIONS
If your generator will be stored with gasoline in the fuel tank, it is important to
reduce the hazard of gasoline vapor ignition.
Select a well-ventilated storage area away from any appliance that operates
with a flame, such as a furnace, water heater, or clothes dryer. Also avoid any
area with a spark-producing electric motor, or where power tools are operated.
If possible, avoid storage areas with high humidity, because that promotes rust
and corrosion.
Place the generator on a level surface. Tilting can cause fuel or oil leakage.
With the engine and exhaust system cool, cover the generator to keep out dust.
A hot engine and exhaust system can ignite or melt some materials.
Do not use a plastic sheet as a dust cover. A nonporous cover will trap moisture
around the generator, promoting rust and corrosion.
Fully charge the battery. Recharge the battery once a month (see page 85).
REMOVAL FROM STORAGE
Check your generator as described in the "BEFORE OPERATION" chapter of this
manual (see page 45).
If the generator was stored for 1 year or longer, drain the fuel tank (see page 89)
and refuel with fresh gasoline. If you keep a container of gasoline for refueling,
be sure that it contains only fresh gasoline. Gasoline oxidizes and deteriorates
over time, causing hard starting.
If the cylinder was coated with oil during storage preparation, the engine may
smoke briefly at startup. This is normal.
31Z376290-A.book 91 ページ 2025年10月24日 金曜日 午後2時44分

92
TRANSPORTING
To prevent spillage when transporting, the generator should be secured upright
in its normal operating position.
Do not lay the generator on its side when moving, storing, or operating it. Oil or fuel
may leak and damage the engine or your property.
Do not operate the generator while it is being transported or while it is
mounted to any type of vehicle, trailer, or boat.
Take care not to drop or strike the generator when transporting. Do not place
heavy objects on the generator.
When using ropes or tie-down straps to secure the generator for transportation,
be sure to only use the frame bars as attachment points. Do not fasten ropes or
straps to any portions of the generator body or the folding transport handle.
An engine that has been running will
remain very hot for a period of time.
A hot engine and exhaust system can
burn you and ignite some material.
If the generator has been used, allow it
to cool for at least 15 minutes before
loading the generator on the transport
vehicle.
31Z376290-A.book 92 ページ 2025年10月24日 金曜日 午後2時44分

93
TAKING CARE OF UNEXPECTED PROBLEMS
ENGINE WILL NOT START
Possible Cause Correction
MAIN switch is in the OFF position. Turn MAIN switch to the ON position
(see page 26).
MAIN switch is left in the ON position
without starting the engine within 30
minutes.
Turn MAIN switch to the OFF position
once and then to the ON position.
CO-MINDER® (CO Shut-off System) is
detecting high carbon monoxide (CO)
levels around the generator.
Review the location of the generator,
such as by placing it in a well-
ventilated outdoor location (see page
28).
When the engine is stopped
automatically by CO-MINDER, press the
CO-MINDER reset button to restart the
engine (see page 56).
Out of fuel. Refuel (see page 21).
Bad fuel, generator stored without
treating or draining gasoline, or
refueled with bad gasoline.
Drain fuel tank (see page 89).
Refuel with fresh gasoline (see
page 21).
Low engine oil level caused Oil Alert
to stop engine.
Turn the MAIN switch to the OFF
position. Add engine oil. Then turn the
MAIN switch to the ON position and
restart the engine.
Spark plug wet with fuel (flooded
engine).
• Turn MAIN switch to OFF position
and pull starter grip swiftly five times
or more. This may dry spark plug.
• If it still not start, remove spark plug
and dry.
Spark plug faulty, fouled, or
improperly gapped.
Gap or replace spark plug (see page
79). Reinstall spark plug.
Fuel filter restricted, fuel system
malfunction, fuel pump failure,
ignition malfunction, valves stuck,
etc.
Take the generator to an authorized
Honda Power Equipment dealer, or
refer to the shop manual.
31Z376290-A.book 93 ページ 2025年10月24日 金曜日 午後2時44分

TAKING CARE OF UNEXPECTED PROBLEMS
94
ENGINE LACKS POWER
NO POWER AT THE AC RECEPTACLES
Possible Cause Correction
Air filter restricted. Clean or replace air filter (see pages 50,
78).
Bad fuel, generator stored without
treating or draining gasoline, or
refueled with bad gasoline.
Drain fuel tank (see page 89).
Refuel with fresh gasoline (see
page 21).
Fuel filter restricted, fuel system
malfunction, fuel pump failure,
ignition malfunction, valves stuck,
etc.
Take the generator to an authorized
Honda Power Equipment dealer, or
refer to the shop manual.
Possible Cause Correction
OUTPUT indicator is OFF, and
OVERLOAD ALARM indicator is ON.
Check AC load. Stop and restart the
engine.
Check the cooling air inlet. Stop and
restart the engine.
AC Circuit protector(s) tripped. Check AC load and reset AC circuit
protector(s) (see page 31).
GFCI system activated. • GFCI receptacle
(120 V 20 A duplex receptacle): Test
GFCI and press the GFCI RESET
button (see page 57).
• Replace or repair power tool or
appliance.
Faulty power tool or appliance. Replace or repair power tool or
appliance.
Stop and restart the engine.
Faulty generator. Take the generator to an authorized
Honda Power Equipment dealer, or
refer to the shop manual.
31Z376290-A.book 94 ページ 2025年10月24日 金曜日 午後2時44分

TAKING CARE OF UNEXPECTED PROBLEMS
95
ENGINE AUTOMATICALLY STOP AND THE CO ALARM INDICATOR FLASHING
ENGINE AUTOMATICALLY STOP AND THE FAULT/CO SENSOR LIFE
INDICATOR FLASHING
FAULT/CO SENSOR LIFE INDICATOR FLASHING WHEN RUNNING THE
ENGINE
Possible Cause Correction
CO concentration around the
generator is high.
Review the location of the generator,
and place it in a well-ventilated
outdoor location (see page 28).
When the engine is stopped
automatically by CO-MINDER®, press
the CO-MINDER reset button to restart
the engine (see page 56).
Possible Cause Correction
CO sensor malfunction. If the engine cannot be started and the
CO ALARM indicator flashes, even if the
location of the generator has changed,
there may be a CO-MINDER®
malfunction. Consult an authorized
Honda Power Equipment dealer.
CO sensor may have reached the end
of its useful lifespan (see page 29).
Consult an authorized Honda Power
Equipment dealer.
Possible Cause Correction
CO sensor may reach the end of its
useful lifespan (see page 29).
Consult an authorized Honda Power
Equipment dealer for replacement.
31Z376290-A.book 95 ページ 2025年10月24日 金曜日 午後2時44分

96
TECHNICAL INFORMATION
SERIAL NUMBER AND TYPE LOCATION
Record the frame serial number and date purchased in the spaces below. You
will need this information when ordering parts and when making technical or
warranty inquiries.
Frame serial number:
Date purchased:
Entering the frame serial number of the generator is required during the first
Bluetooth® connection. Read the QR code or enter the 12 digit frame serial
number contained "- (hyphen)".
Record the password set for the Bluetooth® connection in the space below. Do
not write or attach the password on the generator.
Bluetooth® password:
FRAME SERIAL NUMBER
QR CODE
GENERATOR TYPE
31Z376290-A.book 96 ページ 2025年10月24日 金曜日 午後2時44分

TECHNICAL INFORMATION
97
EMISSION CONTROL SYSTEM INFORMATION
Source of Emissions
The combustion process produces carbon monoxide, oxides of nitrogen, and
hydrocarbons. Control of hydrocarbons and oxides of nitrogen is very important
because, under certain conditions, they react to form photochemical smog
when subjected to sunlight. Carbon monoxide does not react in the same way,
but it is toxic.
Honda utilizes appropriate air/fuel ratios and other emissions control systems to
reduce the emissions of carbon monoxide, oxides of nitrogen, and
hydrocarbons.
Additionally, Honda fuel systems utilize components and control technologies
to reduce evaporative emissions.
The U.S. and California Clean Air Acts, and Environment and Climate
Change Canada (ECCC)
U.S. EPA, California and Canadian regulations require all manufacturers to
furnish written instructions describing the operation and maintenance of
emission control systems.
The following instructions and procedures must be followed in order to keep
the emissions from your Honda engine within the emission standards.
31Z376290-A.book 97 ページ 2025年10月24日 金曜日 午後2時44分

TECHNICAL INFORMATION
98
Tampering and Altering
Tampering is a violation of federal and California law.
Tampering with or altering the emission control system may increase emissions
beyond the legal limit. Among those acts that constitute tampering are:
• Removal or alteration of any part of intake, fuel, or exhaust systems.
• Alterations that would cause the engine to operate outside its design
parameters.
Problems That May Affect Emissions
If you are aware of any of the following symptoms, have your engine inspected
and repaired by your authorized Honda Power Equipment dealer.
• Hard starting or stalling after starting.
•Rough idle.
• Misfiring or backfiring under load.
• Afterburning (backfiring).
• Black exhaust smoke or high fuel consumption.
31Z376290-A.book 98 ページ 2025年10月24日 金曜日 午後2時44分

TECHNICAL INFORMATION
99
Replacement Parts
The emissions control systems on your new Honda engine were designed, built,
and certified to conform with EPA, California (models certified for sale in
California only), and Canadian emissions regulations. We recommend the use
of Honda Genuine parts whenever you have maintenance done. These original
design replacement parts are manufactured to the same standards as the
original parts, so you can be confident of their performance. Honda cannot
deny coverage under the emission warranty solely for the use of non-Honda
replacement parts or service performed at a location other than an authorized
Honda dealership; you may use comparable parts certified by the EPA, CARB or
ECCC, as applicable, and have service performed at non-Honda locations.
However, the use of replacement parts that are not of the original design and
quality may impair the effectiveness of your emissions control system.
A manufacturer of an aftermarket part assumes the responsibility that the part
will not adversely affect emissions performance. The manufacturer or rebuilder
of the part must certify that use of the part will not result in a failure of the
engine to comply with emissions regulations.
Maintenance
As the power equipment engine owner, you are responsible for completing all
required maintenance listed in your owner's manual. Honda recommends that
you retain all receipts covering maintenance on your power equipment engine,
but Honda cannot deny warranty coverage solely for the lack of receipts or for
your failure to ensure that all scheduled maintenance has been completed.
Follow the "MAINTENANCE SCHEDULE" on page 75.
Remember that this schedule is based on the assumption that your Honda
engine product will be used for its designed purpose. Sustained high-load or
high-temperature operation, or use in dusty conditions, will require more
frequent service.
31Z376290-A.book 99 ページ 2025年10月24日 金曜日 午後2時44分

TECHNICAL INFORMATION
100
Air Index
(Models certified for sale in California)
An Air Index Information label is applied to engines certified to an emission
durability time period in accordance with the requirements of the California Air
Resources Board.
The bar graph is intended to provide you, our customer, the ability to compare
the emissions performance of available engines. The lower the Air Index, the
less pollution.
The durability description is intended to provide you with information relating
to the engine’s emission durability period. The durability period of the engine is
1,000 hours. See your "Emission Control System Warranty" (see page 114) for
additional information.
Emission Control Information
An Emission Control Information label describes the engine's emission control
systems. The specification of the evaporative emission control system is
represented by the abbreviated symbol "CM" and means it has a canister as
venting control and the fuel tank barrier is made of metal.
31Z376290-A.book 100 ページ 2025年10月24日 金曜日 午後2時44分

TECHNICAL INFORMATION
101
SPECIFICATIONS
Dimensions
* With battery
En
gine
Model EU7000iSN
Type AN1 AC1
Description code EEJD
Length
[Handle in up position]
33.4 in (848 mm)
[47.2 in (1,198 mm)]
Width 27.6 in (700 mm)
Height 28.4 in (721 mm) 28.7 in (730 mm)
Dry mass [weight]
*
263.2 lbs (119.4 kg) 271.2 lbs (123.0 kg)
Model GX390T2
Engine type 4-stroke, overhead valve, single cylinder
Displacement
[Bore×Stroke]
23.7 cu-in (389 cm
3
)
[3.5×2.5 in (88×64 mm)]
Compression ratio 8.2:1
Engine speed 2,400–3,600 rpm <with Eco Throttle switch ON>
3,300-3,600 rpm <with Eco Throttle switch OFF>
Cooling system Forced air
Ignition system Full transistor
Engine oil capacity 1.2 US qt (1.1 L)
Fuel tank capacity 5.07 US gal (19.2 L)
Spark plug BPR6ES (NGK)
31Z376290-A.book 101 ページ 2025年10月24日 金曜日 午後2時44分

TECHNICAL INFORMATION
102
Generator
Tune-up Specifications
Specifications are subject to change without notice.
AC output Rated voltage 120 V/240 V
Rated frequency 60 Hz
Rated current 45.8 A/22.9 A
Rated output 5.5 kVA
Maximum output 7.0 kVA
ITEM SPECIFICATION MAINTENANCE
Spark plug gap 0.028–0.031 in (0.7–0.8 mm) Refer to page 80.
Valve clearance (cold) IN: 0.15±0.02 mm
EX: 0.20±0.02 mm
See your authorized
Honda dealer.
Other specifications No other adjustments needed.
31Z376290-A.book 102 ページ 2025年10月24日 金曜日 午後2時44分

TECHNICAL INFORMATION
103
WIRING DIAGRAM
NOISE FILTER
GENERATOR (M)
GENERATOR (S)
NOISE FILTER
NOISE FILTER
NOISE FILTER
Gr
W
Bu
R
G
G
Bl/G
Y/Bu
Bl
W
R
Y
Y
Bu
Y/R
Y/Bl
Bl/Y
Bl/W
Bl
W
Y
R
G
Bu
Bl/G
W
R
Bu
Y/Bu
Y/R
Y/Bl
Bl/G
Bl/W
Bu/R
Bu/Y
O/W
G/Bu
G/O
Bu
BlBl
B
-
BA
A
-
Y
Bu
G
Bl
G
RR
R
BATTERY
EARTH
Bl
Bl
Bl
G
G
G
W
R
W
W
W
YY
W
Bu
Y
R
R
W
Bu
R
W
VW
VW
U
U
Bu
R
W
Bu
R
W
Bu
R
AC1_M
MAIN_U_M
MAIN_V_M
MAIN_W_M
MAIN_U_S
MAIN_V_S
MAIN_W_S
AC2_M
AC1_S
AC2_S
ECO SW
N. C.
R
R/W
GND
5V_GCU
RXD_M
RXD_S
TXD_S
S-PLUG IGN COIL
THERIMSTOR
INJECTOR
FFP UNIT STARTER EARTH
TXD_M
GND_GCU
ENGINE BLOCK
INVERTER UNIT
FRAME BLOCK
Bl
Bl/G
THROT
CONTL
MOTOR
PULSER
COIL
OIL
LEVEL
SW
O2
SENSOR
PTC
HEATER
(YOP)
EARTH
TERMINAL
GENERATOR
BLOCK
INVERTER UNIT BLOCK
AN1 type
31Z376290-A.book 103 ページ 2025年10月24日 金曜日 午後2時44分

TECHNICAL INFORMATION
104
G
R
R
RR
R
N
N
NN
R
W
Bu
Bu
RR
R
BuBu
Bu
Bu
W
21
3
4
6
4
7
9
10
12
5
8
11
Bu
Bu
W
W
GFCI
LINELINE
GFCI
W
Gr
Gr
Bu
R
R
Bu
Bu
R
R
W
LOADLOAD
Bu
Bu
W
Bu
G
R
W
Bu
G
Bu
RR
W
G
50A-
125/250V
20A
20A
30A
120V/240V 120V ONLY
VOLT CHANGE SW
W
Y/R
Y/Bl
Bl/Y
Bl/G
Bl/W
Bl
W
Y
R
G
Br/Y
Br/Bu
Br/Bu
Br/W
3A
15A
G/O
FUSE BOX
G/O
Bl/Y
G/O
G/O
Bl/Y
Bl/Y
COMB SW
BAT
START SW
NOISE FILTER
BLUETOOTH UNIT
EARTH 1
START 12
LED 11
12V 10
MAIN 9
N.C. 8
N.C. 5
CO 7
GND 6
COMM 4
TX 3
RX 2
5V 1
IND_CO 2
TRST_SW 4
RESET_SW 5
IND_TROUBLE 3
ACC
MAIN_SW2
MAIN_SW1
G
Bl/Y
N. C. 24
N. C. 23
N. C. 22
N. C. 21
N. C. 20
N. C. 18
N. C. 14
N. C. 16
N. C. 12
N. C. 11
N. C. 10
N. C. 8
N. C. 6
EARTH 4
EARTH 3
STOP+ 2
STOP- 1
POWER_SUPPLY+ 5
IND1_CO 7
IND2_TROBLE 9
IGN 15
TEST 17
RESET 13
RELAY 19
G
G
Bl
Bu
Bl/G
Y/Bu
Bl
W
R
Y
Y
Bu
R
Bu
FUSE
0.5A
R/W
Bl/G
Bu/R
Bu/Y
G/Bu
G/O
Bl/G
Y/Bu
Y/R
Y/Bl
Bl/W
Bl/W
G/O
G/O
W/Bu
Bu/Y
Bu/R
W/G
G/Bu
Br/Y
Br/W
Br/Bu
Bl/Y
O/W
ECO THROTTLE SW
MAIN 1 MAIN 2 BAT ACC
OFF
COM
FREE
PUSH
SW
ON
R
R
NOISE FILTER
1 U
3 V
5 W
1 IGN-
22 DC5V
27 M_TXD
26 M_RXD
28 S_TXD
29 S RXD
2 N. C.
33 N. C.
14 TH (A)
17 TH (B)
16 TH (/B)
19 PC+
24 O/A
20 TH+
25 TH-
34 INJ (+)
LCD
31 INJ (-)
4 FFP (-)
7 STMAG
8 STMAG
9 STMAG(+ 12V)
10 STMAG(+ 12V)
12 MAIN_SW+
11 MAIN_SW-
6 PL (REM)
5 PUSH_SW2
23 PUSH SW1
1 VCC_DRH
2 RXD_DRH
3 TXD_DRH
4 GND
32 GND
3 GND
13 BAT_IN
1 FFP (+)
21 02 SENSOR
15 TH (/A)
18 FUEL_SENSE
30 M_INV_COMN
2 I GN+
Bu
Bl
R
W
Bu
R
R
Bu
Y
Y
Bl
G
G
G
Y
W
W
W/G
W/Bu
Bu/R
Bu/Y
Br/W
G/Bu
W/R
DC15V_1 1
N. C. 2
CO 3
LG 4
G
G/W
Bu/R
Bu/Y
G
P
W/G
W/Bu
G/Bu
G
P
W/G
W/G
W/O
Bl/Bu
Y/Bu
Y/R
G/Bu
Bu/R
Bu/Y
G
R
W/Bu
G/W
G
P
W/G
W/Bu
Y/R
W/R
W/R
W/O
P
G
G
G
Y
G
Y
RR
(SHOWN 120V/240V POSITION)
CONTROL PANEL BLOCK
PARALLEL OPERATION BLOCK
COMB SW
START SW
COM
ON
OFF
SW
ECO THROTTLE SW
PARALLEL OPERATION BOX
W
W
Bu
Bu
Br/BuBr/Bu
Bu
G
R
W
Bl BLACK
YELLOW
BROWNBr
ORANGEO
LIGHT BLUELb
LIGHT GREENLg
PINKP
GRAYGr
BLUE
GREEN
RED
WHITE
V BEIGEBeVIOLET
Y
COLOR COMB: GROUND/MARKING
Bu
N
CIRCUIT PROTECTOR
RECEPTACLE
GFCI
(20A-125V)
RECEPTACLE
GFCI
(20A-125V)
RECEPTACLE
(30A-125V)
PROTECTOR
CIRCUIT
30A
RECEPTACLE
(30A-125/250V)
PARALLEL
OPERATION
OUTLETS
CIRCUIT PROTECTOR
50A
EARTH
TERMINAL
GENERATOR
CONTROL UNIT
CO UNIT and INDICATOR UNIT
31Z376290-A.book 104 ページ 2025年10月24日 金曜日 午後2時44分

TECHNICAL INFORMATION
105
NOISE FILTER
GENERATOR (M)
GENERATOR (S)
NOISE FILTER
NOISE FILTER
NOISE FILTER
Gr
W
Bu
R
G
G
Bl/G
Y/Bu
Bl
W
R
Y
Y
Bu
Y/R
Y/Bl
Bl/Y
Bl/W
Bl
W
Y
R
G
Bu
Bl/G
W
R
Bu
Y/Bu
Y/R
Y/Bl
Bl/G
Bl/W
Bu/R
Bu/Y
O/W
G/Bu
G/O
Bu
BlBl
B
-
BA
A
-
Y
Bu
G
Bl
G
R
R
R
BATTERY
EARTH
Bl
Bl
Bl
G
G
G
W
R
W
W
W
YY
W
Bu
Y
R
R
W
Bu
R
W
VW
VW
U
U
Bu
R
W
Bu
R
W
Bu
R
AC1_M
MAIN_U_M
MAIN_V_M
MAIN_W_M
MAIN_U_S
MAIN_V_S
MAIN_W_S
AC2_M
AC1_S
AC2_S
ECO SW
N. C.
R
R/W
GND
5V_GCU
RXD_M
RXD_S
TXD_S
S-PLUG IGN COIL
THERIMSTOR
INJECTOR
FFP UNIT STARTER EARTH PCSV
TXD_M
GND_GCU
ENGINE BLOCK
INVERTER UNIT
FRAME BLOCK
Bl
Bl/G
THROT
CONTL
MOTOR
PULSER
COIL
OIL
LEVEL
SW
O2
SENSOR
PTC
HEATER
(YOP)
EARTH
TERMINAL
GENERATOR
BLOCK
INVERTER UNIT BLOCK
Bu
W/R
AC1 type
31Z376290-A.book 105 ページ 2025年10月24日 金曜日 午後2時44分

TECHNICAL INFORMATION
106
G
R
R
RR
R
N
N
NN
R
W
Bu
Bu
RR
R
BuBu
Bu
Bu
W
21
3
4
6
4
7
9
10
12
5
8
11
Bu
Bu
W
W
GFCI
LINELINE
GFCI
W
Gr
Gr
Bu
R
R
Bu
Bu
R
R
W
LOADLOAD
Bu
Bu
W
Bu
G
R
W
Bu
G
Bu
RR
W
G
50A-
125/250V
20A
20A
30A
120V/240V 120V ONLY
VOLT CHANGE SW
W
Y/R
Y/Bl
Bl/Y
Bl/G
Bl/W
Bl
W
Y
R
G
Br/Y
Br/Bu
Br/Bu
Br/W
3A
15A
G/O
FUSE BOX
G/O
Bl/Y
G/O
G/O
Bl/Y
Bl/Y
COMB SW
BAT
START SW
NOISE FILTER
BLUETOOTH UNIT
EARTH 1
START 12
LED 11
12V 10
MAIN 9
N.C. 8
N.C. 5
CO 7
GND 6
COMM 4
TX 3
RX 2
5V 1
IND_CO 2
TRST_SW 4
RESET_SW 5
IND_TROUBLE 3
ACC
MAIN_SW2
MAIN_SW1
G
Bl/Y
N. C. 24
N. C. 23
N. C. 22
N. C. 21
N. C. 20
N. C. 18
N. C. 14
N. C. 16
N. C. 12
N. C. 11
N. C. 10
N. C. 8
N. C. 6
EARTH 4
EARTH 3
STOP+ 2
STOP- 1
POWER_SUPPLY+ 5
IND1_CO 7
IND2_TROBLE 9
IGN 15
TEST 17
RESET 13
RELAY 19
G
G
Bl
Bu
Bl/G
Y/Bu
Bl
W
R
Y
Y
Bu
R
Bu
FUSE
0.5A
R/W
Bl/G
Bu/R
Bu/Y
G/Bu
G/O
Bl/G
Y/Bu
Y/R
Y/Bl
Bl/W
Bl/W
G/O
G/O
W/Bu
Bu/Y
Bu/R
W/G
G/Bu
Br/Y
Br/W
Br/Bu
Bl/Y
O/W
ECO THROTTLE SW
MAIN 1 MAIN 2 BAT ACC
OFF
COM
FREE
PUSH
SW
ON
R
R
NOISE FILTER
1 U
3 V
5 W
1 IGN-
22 DC5V
27 M_TXD
26 M_RXD
28 S_TXD
29 S RXD
2 N. C.
33 N. C.
14 TH (A)
17 TH (B)
16 TH (/B)
19 PC+
24 O/A
20 TH+
25 TH-
34 INJ (+)
LCD
31 INJ (-)
4 FFP (-)
7 STMAG
8 STMAG
9 STMAG(+ 12V)
10 STMAG(+ 12V)
12 MAIN_SW+
11 MAIN_SW-
6 PL (REM)
5 PUSH_SW2
23 PUSH SW1
1 VCC_DRH
2 RXD_DRH
3 TXD_DRH
4 GND
32 GND
3 GND
13 BAT_IN
1 FFP (+)
21 02 SENSOR
15 TH (/A)
18 FUEL_SENSE
30 M_INV_COMN
2 I GN+
Bu
Bl
R
W
Bu
R
R
Bu
Y
Y
Bl
G
G
G
Y
W
W
W/G
W/Bu
Bu/R
Bu/Y
Br/W
G/Bu
W/R
DC15V 1
N. C. 2
CO 3
LG 4
PCSV 5
G
G/W
Bu/R
Bu/Y
G
P
W/G
W/Bu
G/Bu
Bu
G
P
W/G
W/G
W/O
Bl/Bu
Y/Bu
Y/R
G/Bu
Bu/R
Bu/Y
G
R
W/Bu
G/W
G
P
W/G
W/Bu
Y/R
W/R
W/R
W/O
P
G
G
G
Y
G
Y
RR
(SHOWN 120V/240V POSITION)
CONTROL PANEL BLOCK
PARALLEL OPERATION BLOCK
COMB SW
START SW
COM
ON
OFF
SW
ECO THROTTLE SW
PARALLEL OPERATION BOX
W
W
Bu
Bu
Br/BuBr/Bu
Bu
G
R
W
Bl BLACK
YELLOW
BROWNBr
ORANGEO
LIGHT BLUELb
LIGHT GREENLg
PINKP
GRAYGr
BLUE
GREEN
RED
WHITE
V BEIGEBeVIOLET
Y
COLOR COMB: GROUND/MARKING
Bu
N
CIRCUIT PROTECTOR
RECEPTACLE
GFCI
(20A-125V)
RECEPTACLE
GFCI
(20A-125V)
RECEPTACLE
(30A-125V)
PROTECTOR
CIRCUIT
30A
RECEPTACLE
(30A-125/250V)
PARALLEL
OPERATION
OUTLETS
CIRCUIT PROTECTOR
50A
EARTH
TERMINAL
GENERATOR
CONTROL UNIT
CO UNIT and INDICATOR UNIT
Bu
W/R
31Z376290-A.book 106 ページ 2025年10月24日 金曜日 午後2時44分

107
CONSUMER INFORMATION
DEALER LOCATOR INFORMATION
To find an authorized Honda Servicing Dealer anywhere in the United States:
Visit our website:
http://powerequipment.honda.com/dealer-locator
Honda PUBLICATIONS
Shop Manual
This manual covers complete maintenance and overhaul procedures.
It is intended to be used by a skilled technician.
Available through your Honda dealer or
visit http://powerequipment.honda.com/support/shop-manuals
Parts Catalog
This manual provides complete, illustrated parts lists for your generator. Visit
peparts.honda.com for free online access to the parts catalog. It is also available
for purchase in paper form through your Honda dealer or by visiting:
https://publications.powerequipment.honda.com/power-equipment
Accessories Catalog
Your authorized Honda Power Equipment dealer offers a wide selection of
accessories (optional equipment) to make your generator even more useful.
Visit http://powerequipment.honda.com/generators/accessories and click on
See all generator accessories to see the entire catalog of accessories.
31Z376290-A.book 107 ページ 2025年10月24日 金曜日 午後2時44分

CONSUMER INFORMATION
108
CUSTOMER SERVICE INFORMATION
Honda Power Equipment dealership personnel are trained professionals. They
should be able to answer any question you may have. If you encounter a
problem that your dealer does not solve to your satisfaction, please discuss it
with the dealership’s management.
The Service Manager or General Manager can help. Almost all problems are
solved in this way.
If you are dissatisfied with the decision made by the dealership’s management,
contact the Honda Power Equipment Customer Relations Office. You can write
to:
American Honda Motor Co., Inc.
Power Equipment Division
Customer Relations Office
4900 Marconi Drive
Alpharetta, Georgia 30005-8847
Or telephone: (770) 497-6400
1-888-888-3139 (toll free)
9:00 am to 7:30 pm EST
To email Honda, visit
powerequipment.honda.com/support/contact-us
When you write or call, please give us this information:
• Model and serial numbers (see page 96)
• Name of the dealer who sold the generator to you
• Name and address of the dealer who services your generator
• Date of purchase
• Your name, address, and telephone number
• A detailed description of the problem
31Z376290-A.book 108 ページ 2025年10月24日 金曜日 午後2時44分

CONSUMER INFORMATION
109
Distributor’s Limited Warranty
This warranty is limited to the following Honda products when distributed by
American Honda Motor Co., Inc., Power Sports and Products Division, 4900
Marconi Drive, Alpharetta, Georgia 30005. The following warranty applies to
products manufactured on or after April 1, 2023.
(1) Length of Warranty: Batteries supplied with applicable products as
standard, original equipment are covered by this warranty for a period of 12
months (private residential) or 3 months (commercial/rental/institutional
use) from the date of original retail product purchase.
(2) Private residential: Used in maintaining owner’s primary and/or secondary
residence. Any other use, including but not limited to informal "for hire" use,
is considered commercial/rental/institutional use.
To Qualify for This Warranty:
The product must be purchased in the United States, Puerto Rico, or the U.S.
Virgin Islands from American Honda or a dealer authorized by American Honda
to sell those products. This warranty applies to first retail purchaser and each
subsequent owner during the applicable warranty time period, unless noted
otherwise.
What American Honda Will Repair or Replace Under Warranty:
American Honda will repair or replace, at its option, any part that is proven to be
defective in material or workmanship under normal use during the applicable
warranty time period. Warranty repairs and replacements will be made without
charge for parts or labor. Anything replaced under warranty becomes the
property of American Honda Motor Co., Inc. All parts replaced under warranty
will be considered as part of the original product, and any warranty on those
parts will expire coincident with the original product warranty.
PRODUCTS COVERED
BY THIS WARRANTY:
LENGTH OF WARRANTY: (1)
(FROM DATE OF ORIGINAL RETAIL PURCHASE)
PRIVATE
RESIDENTIAL (2)
COMMERCIAL/
RENTAL/INSTITUTIONAL
Generators 36 months 12 months
The Parts, Accessories, and Apparel warranty is on page 112
31Z376290-A.book 109 ページ 2025年10月24日 金曜日 午後2時44分

CONSUMER INFORMATION
110
To Obtain Warranty Service:
You must, at your expense, take the Honda Power Equipment product,
accessory, replacement part, apparel, or the power equipment on which the
accessory or replacement part is installed, and proof of purchase to any Honda
Power Equipment dealer in the United States, Puerto Rico, or the U.S. Virgin
Islands who is authorized to sell and/or service that product, during the dealer’s
normal business hours. To locate a dealer near you, visit our web site at http://
powerequipment.honda.com and click on Find a Dealer.
If you are unable to obtain warranty service or are dissatisfied with the warranty
service you receive, contact the owner of the dealership involved;
normally this will resolve the problem. However, if you should require further
assistance, write or call the Power Equipment Customer Relations Department
of American Honda Motor Co., Inc. at the following address:
American Honda Motor Co., Inc.
Power Equipment Customer Relations Dept.
4900 Marconi Drive
Alpharetta, GA 30005-8847 Telephone: (770) 497-6400
31Z376290-A.book 110 ページ 2025年10月24日 金曜日 午後2時44分

CONSUMER INFORMATION
111
Exclusions:
1. Any damage or deterioration resulting from the following:
– Neglect of the periodic maintenance as specified in the product owner’s
manual
– Improper repair or maintenance
– Operating methods other than those indicated in the product owner’s
manual
– Increasing engine speed beyond factory specification
– The use of non-genuine Honda parts, accessories, lubricants, and fluids
other than those approved by Honda
– Exposure of the product to soot and smoke, chemical agents, bird
droppings, sea water, salt, or other corrosive environments
– Collision, fuel contamination or deterioration, neglect, unauthorized
alteration, misuse, incorporation or use of unsuitable attachments or parts
– Normal wear and tear (including, but not limited to, normal fading of
painted or plated surfaces, sheet peeling, and other natural deterioration)
2. Consumable parts: Honda does not warrant parts deterioration due to
normal wear and tear. The following parts are not covered by this warranty
unless they are needed during another repair covered under this warranty:
spark plug, fuel filter, air cleaner element, clutch disc, tire, wheel bearing,
recoil starter rope, cable, belt, cutter blade, oil, and grease.
3. Cleaning, adjustment, and normal periodic maintenance work (carburetor
cleaning, engine oil draining, blade sharpening, belt and cable adjustments).
4. Any product that has ever been declared a total loss or sold for salvage by a
financial institution or insurer.
5. Auger and paddle assemblies, skid shoes, and scraper bars of snow throwers/
snow blowers, tiller tines of roto-tillers, and mower blades and mower deck
housings are specifically not warranted against impact damage including,
but not limited to, abrasive damage.
Disclaimer of Consequential Damage and Limitation of Implied Warranties:
American Honda disclaims any responsibility for loss of time or use of the
product, transportation, commercial loss, or any other incidental or
consequential damage. Any implied warranties are limited to the duration of
this written limited warranty. Some states do not allow limitations on how long
an implied warranty lasts and/or do not allow the exclusion or limitation of
incidental or consequential damages, therefore the above exclusions and
limitations may not apply to you. This warranty gives you specific legal rights,
and you may also have other rights, which vary from state to state.
31Z376290-A.book 111 ページ 2025年10月24日 金曜日 午後2時44分

CONSUMER INFORMATION
112
Honda Parts, Accessories, and Apparel
This warranty is limited to Honda Power Equipment parts, accessories, and
apparel when distributed by American Honda Motor Co., Inc., 4900 Marconi
Drive, Alpharetta, Georgia 30005-8847.
To Qualify for This Warranty:
1. The parts, accessories, or apparel must be purchased from American Honda
or a dealer authorized by American Honda to sell those products in the
United States, Puerto Rico, and the U.S. Virgin Islands. Parts and accessories
must be purchased for installation on original Honda equipment or engines
to be eligible for warranty coverage.
Installing parts and accessories on non-Honda products or engines voids this
warranty.
2. You must be the first retail purchaser. This warranty is not transferable to
subsequent owners.
What American Honda Will Repair or Replace Under Warranty:
American Honda will repair or replace, at its option, any Honda Power
Equipment parts, accessories, or apparel that are proven to be defective in
material or workmanship under normal use during the applicable warranty time
period. Anything replaced under warranty becomes the property of American
Honda Motor Co., Inc. The warranty on all parts, accessories, and apparel
replaced under warranty will expire coincident with the original warranty on the
replaced parts, accessories, or apparel.
Parts and accessories installed by a dealer who is authorized by American
Honda to sell them will be repaired or replaced under warranty without charge
for parts or labor. If installed by anyone else, parts and accessories will be
repaired or replaced under warranty without charge for parts, but any labor
charges will be the responsibility of the purchaser.
Apparel will be repaired or replaced under warranty without any charge.
PRODUCTS COVERED
BY WARRANTY:
LENGTH OF WARRANTY:
(FROM DATE OF ORIGINAL RETAIL PURCHASE)
PRIVATE
RESIDENTIAL
COMMERCIAL/
RENTAL/INSTITUTIONAL
Parts 6 months 3 months
Batteries 6 months 3 months
Accessories 12 months 3 months
Apparel 6 months 3 months
31Z376290-A.book 112 ページ 2025年10月24日 金曜日 午後2時44分

CONSUMER INFORMATION
113
To Obtain Warranty Service:
You must, at your expense, take the Honda Power Equipment part, accessory, or
apparel, or the Honda Power Equipment on which the accessory or part is
installed, and proof of purchase to any Honda Power Equipment dealer in the
United States, Puerto Rico, or the U.S. Virgin Islands who is authorized to sell
that product, during the dealer’s normal business hours.
To locate a dealer near you, go to our web site at http://PowerEquipment.Honda.com
and click on Find a Dealer.
If you are unable to obtain warranty service or are dissatisfied with the warranty
service you receive, contact the owner of the dealership involved; normally this
will resolve the problem. However, if you should require further assistance,
write or call the Power Equipment Customer Relations Department of American
Honda Motor Co., Inc. Refer to page 110 for contact information.
Exclusions:
This warranty does not extend to parts, accessories, or apparel affected or
damaged by collision, normal wear, use in an application for which the product
was not designed, or any other misuse, neglect, incorporation or use of
unsuitable attachments or parts, unauthorized alteration, improper installation,
or any causes other than defects in material or workmanship of the product.
Installing parts and accessories on non-Honda products or engines voids this
warranty.
Disclaimer of Consequential Damage and Limitation of Implied Warranties:
American Honda disclaims any responsibility for loss of time or use of the
product, or the power equipment on which the product is installed,
transportation, commercial loss, or any other incidental or consequential
damage. Any implied warranties are limited to the duration of this written
warranty. Some states do not allow limitations on how long an implied warranty
lasts and/or do not allow the exclusion or limitation of incidental or
consequential damages, so the above exclusions and limitations may not apply
to you.
This warranty gives you specific legal rights, and you may also have other rights,
which vary from state to state.
31Z376290-A.book 113 ページ 2025年10月24日 金曜日 午後2時44分

CONSUMER INFORMATION
114
Emission Control System Warranty
Your new Honda Power Equipment engine complies with the U.S. EPA,
Environment Canada, and State of California (models certified for sale in
California only) emission regulations. American Honda Motor Co., Inc. provides
the emission warranty coverage for engines in the United States and its
territories. Honda Canada Inc. provides the emission warranty for engines in the
13 provinces and territories of Canada. In the remainder of this Emission Control
System Warranty, American Honda Motor Co., Inc. and Honda Canada Inc. will
be referred to as Honda.
CALIFORNIA EXHAUST AND EVAPORATIVE EMISSIONS CONTROL
WARRANTY STATEMENT YOUR WARRANTY RIGHTS AND OBLIGATIONS
The California Air Resources Board and Honda are pleased to explain the
exhaust and evaporative emissions ("emissions") control system warranty on
your 2026 and later Honda Power Equipment engine. In California, new
equipment that use small off-road engines must be designed, built, and
equipped to meet the State's stringent anti-smog standards. Honda must
warrant the emissions control system on your power equipment engine for the
periods of time listed below provided there has been no abuse, neglect, or
improper maintenance of your small off-road engine or equipment leading to
the failure of the emissions control system.
Your emissions control system may include parts such as the carburetor or
fuel-injection system, the ignition system, catalytic converter, fuel tanks, fuel
lines (for liquid fuel and fuel vapors), fuel caps, valves, canisters, filters, clamps
and other associated components. Also included may be hoses, belts,
connectors, and other emission-related assemblies (see page 118 for additional
covered parts).
Where a warrantable condition exists, Honda will repair your power equipment
engine at no cost to you including diagnosis, parts and labor.
MANUFACTURER’S WARRANTY COVERAGE:
The exhaust and evaporative emissions control system on your Honda power
equipment engine is warranted for two years. If any emissions-related part on
your Honda power equipment engine is defective, the part will be repaired or
replaced by Honda.
31Z376290-A.book 114 ページ 2025年10月24日 金曜日 午後2時44分

CONSUMER INFORMATION
115
OWNER'S WARRANTY RESPONSIBILITY:
• As the power equipment engine owner, you are responsible for the
performance of the required maintenance listed in your owner's manual.
Honda recommends that you retain all receipts covering maintenance on
your power equipment engine, but Honda cannot deny warranty coverage
solely for the lack of receipts or for your failure to ensure the performance of
all scheduled maintenance.
• As the power equipment engine owner, you should however be aware that
Honda may deny you warranty coverage if your power equipment engine or a
part has failed due to abuse, neglect, improper maintenance, or unapproved
modifications.
• You are responsible for presenting your power equipment engine to a Honda
Power Equipment servicing dealer as soon as the problem exists. The
warranty repairs shall be completed in a reasonable amount of time, not to
exceed 30 days.
If you have any questions regarding your warranty rights and responsibilities,
you should contact the Honda office in your region:
American Honda Motor Co., Inc.
Power Equipment Customer
Relations
4900 Marconi Drive
Alpharetta, Georgia 30005-8847
Telephone: (888) 888-3139
Email: powerequipmentemissions
@ahm.honda.com
or
Honda Canada Inc.
Power Equipment Customer
Relations
180 Honda Blvd.
Markham, ON, L6C 0H9
Telephone: (888) 946-6329
31Z376290-A.book 115 ページ 2025年10月24日 金曜日 午後2時44分

CONSUMER INFORMATION
116
YOUR WARRANTY RIGHTS AND OBLIGATIONS
Other States, U.S. territories, and Canada:
In other areas of the United States and in Canada, your engine must be
designed, built, and equipped to meet the U.S. EPA and Environment Canada
emission standards for spark-ignited engines at or below 19 kilowatts.
Specific Honda products that do not meet the California emissions regulations
can be identified by a "California: Not for sale or use" or "California: Only for use
in Farming or Construction Equipment" decal.
All of the United States and Canada:
The exhaust and evaporative emissions control system on your Honda power
equipment engine sold in the United States and Canada is warranted for two
years from the date of delivery to the ultimate purchaser or the length of the
Honda Distributor’s Limited Warranty, whichever is longer. This warranty is
transferable to each subsequent purchaser for the duration of the warranty
period.
If any emissions-related part on your Honda power equipment engine is
defective, the part will be repaired or replaced by Honda. All defective parts
replaced under this warranty become the property of Honda. Only Honda
approved replacement parts may be used in the performance of any warranty
repairs and must be provided without charge to the owner. A list of warranted
parts is on the reverse side of this warranty statement. All emission related parts
are under warranty for the remainder of the warranty period. Normal
maintenance items, such as spark plugs and filters, that are on the warranted
parts list are warranted up to their required replacement interval only.
Honda will also replace other engine components damaged by a failure of any
warranted part during the warranty period. Honda cannot deny coverage under
the emission warranty solely for use of non-Honda replacement parts or service
performed at a location other than an authorized Honda dealership; however,
use of a part that is not functionally identical to the original equipment part in
any respect that may in any way affect emissions (including durability) could
result in denial of coverage. If such a non-Honda replacement part is used in the
repair or maintenance of your engine, and an authorized Honda dealer
determines it is defective or causes a failure of a warranted part, your claim for
repair of your engine may be denied. If the part in question is not related to the
reason your engine requires repair, your claim will not be denied.
31Z376290-A.book 116 ページ 2025年10月24日 金曜日 午後2時44分

CONSUMER INFORMATION
117
TO OBTAIN WARRANTY SERVICE:
You must, at your own expense, take your Honda Power Equipment engine or
the product on which it is installed, along with your sales registration card or
other proof of original purchase date, to any Honda Power Equipment dealer
who is authorized by Honda to sell and service that Honda product during their
normal business hours. Claims for repair or adjustment found to be caused
solely by defects in material or workmanship will not be denied because the
engine was not properly maintained and used.
If you are unable to obtain emission warranty service or are dissatisfied with the
warranty service you received, contact the owner of the dealership involved.
Normally this should resolve your problem. However, if you require further
assistance, contact the Honda office in your region:
EXCLUSIONS:
Failures other than those resulting from defects in material or workmanship are
not covered by this warranty. This warranty does not extend to emission control
systems or parts that are affected or damaged by owner abuse, neglect,
improper maintenance, or unapproved modifications.
This warranty does not cover replacement of expendable maintenance items
made in connection with required maintenance service after the item’s first
scheduled replacement as listed in the maintenance section of the product
owner’s manual, such as: spark plugs and filters.
American Honda Motor Co., Inc.
Power Equipment Customer
Relations
4900 Marconi Drive
Alpharetta, Georgia 30005-8847
Telephone: (888) 888-3139
Email: powerequipmentemissions
@ahm.honda.com
or
Honda Canada Inc.
Power Equipment Customer
Relations
180 Honda Blvd.
Markham, ON, L6C 0H9
Telephone: (888) 946-6329
31Z376290-A.book 117 ページ 2025年10月24日 金曜日 午後2時44分

CONSUMER INFORMATION
118
DISCLAIMER OF CONSEQUENTIAL DAMAGE AND LIMITATION OF IMPLIED
WARRANTIES:
American Honda Motor Co., Inc. and Honda Canada Inc. disclaim any
responsibility for incidental or consequential damages such as loss of time or
the use of the power equipment, or any commercial loss due to the failure of the
equipment; and any implied warranties are limited to the duration of this
written warranty. This warranty is applicable only where the California, U.S. EPA,
or Environment Canada emission control system warranty regulation is in effect.
EMISSION CONTROL SYSTEM WARRANTY PARTS:
*Covered up to the first required replacement only.
See the "MAINTENANCE SCHEDULE" on page 75.
SYSTEMS COVERED
BY THIS WARRANTY:
PARTS
DESCRIPTION:
Fuel Metering Carburetor assembly (includes starting enrichment
system), Oxygen sensor, Throttle body, Engine
temperature sensor, Engine control module, Fuel
injector, Fuel regulator, Intake manifold
Evaporative Fuel tank, Fuel cap, Fuel cap tether, Fuel lines (for
liquid and fuel vapors), Carbon canister, Canister
mounting brackets, Fuel line fittings, Fuel strainer,
Fuel valve, Fuel pump, Fuel hose joint, Canister
purge line, Canister purge port connector,
Evaporative emission canister purge valve
Exhaust Catalyst, Exhaust pipe, Muffler (with catalyst),
Exhaust manifold
Air Induction Air cleaner case, Air cleaner element*
Ignition Flywheel comp., Flywheel magneto, Ignition pulse
generator, Crankshaft position sensor, Power coil,
Ignition coil assembly, Ignition control module,
Spark plug cap, Spark plug*
Crankcase Emission
Control
Crankcase breather tube, Breather valve assembly,
Cover assembly head, Oil filler cap
Miscellaneous Parts Tubing, fittings, seals, gaskets, and clamps
associated with these listed systems.
31Z376290-A.book 118 ページ 2025年10月24日 金曜日 午後2時44分

CONSUMER INFORMATION
119
REGISTRATION
Please Register Your Generator
If your dealer did not collect registration information from you, please take a
few minutes and register your purchase with Honda. This allows us to contact
you with any important updates regarding your generator. Please note
registration is not required to obtain warranty service. You can register your
generator by visiting the Honda Power Equipment website,
http://powerequipment.honda.com/support and click on Product Registration.
Your information will remain confidential. It will not be released to any other
company or organization.
31Z376290-A.book 119 ページ 2025年10月24日 金曜日 午後2時44分

120
OPTIONAL PARTS
HANGER KIT
Protect the fuel tank and frame pipe with the protector films during installation
of the hanger.
1. Slide one end of the hanger under the frame pipe on the left side of the
generator.
2. Slide the other end of the hanger under the frame pipe on the right side of
the generator.
3. Slide the hanger along the frame pipes to align the center of the hanger with
the recessed part on the rear side of the fuel tank.
4. Install the hanger brackets on both ends of the hanger and tighten the
8×16 mm flange bolts securely.
Torque: 19.5 lbf·ft (26.5 N·m, 2.7 kgf·m)
PROTECTOR FILM
(commercially available)
HANGER
8×16 mm FLANGE BOLT (4)
HANGER
BRACKET (2)
HANGER
31Z376290-A.book 120 ページ 2025年10月24日 金曜日 午後2時44分

121
REFERENCE INFORMATION
"QR Code" is registered trademark of DENSO WAVE INCORPORATED.
The Bluetooth word mark and logos are registered trademarks owned by
Bluetooth SIG, Inc., and any use of such marks by Honda Motor Co., Ltd., is under
license. Other trademarks and trade names are those of their respective owners.
FCC Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including
interference that may cause undesired operation.
FCC CAUTION
Changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
Responsible Party – U.S. Contact Information
Hosiden America Corp.
120 East State Parkway, Schaumburg, IL. 60173, U.S.A.
E-mail address: [email protected]
Note: The Bluetooth unit included with this equipment has been tested and
found to comply with the limits for a Class B digital device, pursuant to part 15
of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
31Z376290-A.book 121 ページ 2025年10月24日 金曜日 午後2時44分

122
INDEX
A
AC Appliance and Power Cord........................................................................................ 48
AC Applications.................................................................................................................... 62
AC Circuit Protectors .......................................................................................................... 31
AC OPERATION ..................................................................................................................... 60
AC Parallel Operation Applications............................................................................... 67
AC PARALLEL OPERATION................................................................................................ 65
AC Receptacle Selection.................................................................................................... 63
AIR CLEANER SERVICE ........................................................................................................ 78
AIR FILTER CHECK ................................................................................................................ 50
Air Index ............................................................................................................................... 100
ARE YOU READY TO GET STARTED? .............................................................................. 45
ASSEMBLY........................................................................................................................ 14, 15
B
Battery Charging.................................................................................................................. 85
Battery Installation .............................................................................................................. 85
Battery Maintenance Cover and Wheel Kit................................................................. 47
Battery Removal ................................................................................................................... 83
BATTERY SERVICE................................................................................................................. 82
Battery............................................................................................................................... 17, 90
BEFORE OPERATION ........................................................................................................... 45
Bluetooth® Function ............................................................................................................ 44
C
Carbon Monoxide Hazards................................................................................................. 8
Check the Battery Voltage................................................................................................ 46
Check the Engine................................................................................................................. 46
Check the GFCI...................................................................................................................... 46
Cleaning .................................................................................................................................. 87
CO-MINDER® (CO Shut-off System) ............................................................................... 28
COMPONENT & CONTROL LOCATIONS ....................................................................... 24
Connections to a Building’s Electrical System........................................................... 71
CONSUMER INFORMATION........................................................................................... 107
CONTROLS & FEATURES .................................................................................................... 24
CONTROLS.............................................................................................................................. 26
CUSTOMER SERVICE INFORMATION .......................................................................... 108
D
DEALER LOCATOR INFORMATION.............................................................................. 107
Distributor’s Limited Warranty...................................................................................... 109
31Z376290-A.book 122 ページ 2025年10月24日 金曜日 午後2時44分

123
INDEX
E
Eco Throttle® Switch ........................................................................................................... 27
ECO THROTTLE® SYSTEM .................................................................................................. 70
Electric Shock Hazards ......................................................................................................... 9
Emergency Procedures...................................................................................................... 82
Emission Control Information ...................................................................................... 100
EMISSION CONTROL SYSTEM INFORMATION............................................................ 97
Emission Control System Warranty............................................................................ 114
ENGINE AUTOMATICALLY STOP AND THE CO ALARM INDICATOR
FLASHING .......................................................................................................................... 95
ENGINE AUTOMATICALLY STOP AND THE FAULT/CO SENSOR LIFE
INDICATOR FLASHING................................................................................................... 95
Engine Cylinder .................................................................................................................... 90
ENGINE LACKS POWER....................................................................................................... 94
ENGINE OIL CHANGE .......................................................................................................... 76
ENGINE OIL LEVEL CHECK ................................................................................................. 49
ENGINE OIL RECOMMENDATIONS................................................................................. 20
ENGINE OIL...................................................................................................................... 19, 90
ENGINE START Button........................................................................................................ 26
ENGINE WILL NOT START .................................................................................................. 93
F
FAULT/CO SENSOR LIFE INDICATOR FLASHING WHEN RUNNING
THE ENGINE....................................................................................................................... 95
FEATURES ............................................................................................................................... 35
Fire and Burn Hazards .......................................................................................................... 9
Foam Air Filter Cleaning.................................................................................................... 78
Folding Handle ..................................................................................................................... 33
Fuel Gauge (AN1 type only)............................................................................................. 43
FUEL RECOMMENDATIONS.............................................................................................. 23
FUEL................................................................................................................................... 21, 87
FUSE.......................................................................................................................................... 86
G
GENERATOR SAFETY............................................................................................................. 7
GFCI OPERATION CHECK................................................................................................... 57
Ground Fault Circuit Interrupter (GFCI) Receptacle ................................................ 32
Ground Terminal.................................................................................................................. 35
31Z376290-A.book 123 ページ 2025年10月24日 金曜日 午後2時44分

124
INDEX
H
HANGER KIT ........................................................................................................................ 120
Honda PUBLICATIONS..................................................................................................... 107
HOW TO RESTART WHEN STOPPED BY CO-MINDER® (CO SHUT-OFF SYSTEM)
............................................................................................................................................... 56
I
i-Monitor™ .............................................................................................................................. 38
IMPORTANT SAFETY INFORMATION............................................................................... 7
INITIAL USE INSTRUCTIONS.............................................................................................. 19
INTRODUCTION ...................................................................................................................... 1
IS YOUR GENERATOR READY TO GO?........................................................................... 45
K
Knowledge ............................................................................................................................. 45
L
Loose Parts ............................................................................................................................. 15
M
MAIN Switch .......................................................................................................................... 26
Maintenance.......................................................................................................................... 99
Maintenance Covers........................................................................................................... 34
MAINTENANCE SAFETY ..................................................................................................... 74
MAINTENANCE SCHEDULE............................................................................................... 75
N
NO POWER AT THE AC RECEPTACLES .......................................................................... 94
O
OIL ALERT®/CHECK Indicator ........................................................................................... 37
OPERATION ............................................................................................................................ 52
Operator Responsibility....................................................................................................... 7
OPTIONAL PARTS.............................................................................................................. 120
OVERLOAD ALARM (Indicator)........................................................................................ 36
OUTPUT Indicator................................................................................................................ 36
P
Parallel Operation Outlets ................................................................................................ 30
Please Register Your Generator................................................................................... 119
Power Producing Circuits ................................................................................................. 63
Problems That May Affect Emissions............................................................................ 98
31Z376290-A.book 124 ページ 2025年10月24日 金曜日 午後2時44分

125
INDEX
Q
QUICK REFERENCE INFORMATION ...................................................inside back cover
R
REFERENCE INFORMATION ........................................................................................... 121
Refuel With Care................................................................................................................... 10
REGISTRATION ................................................................................................................... 119
REMOVAL FROM STORAGE............................................................................................... 91
Replacement Parts .............................................................................................................. 99
S
SAFE OPERATING PRECAUTIONS ................................................................................... 51
SAFETY LABEL LOCATIONS............................................................................................... 11
Safety Precautions............................................................................................................... 74
SAFETY..................................................................................................................................... 14
SERIAL NUMBER AND TYPE LOCATION........................................................................ 96
SERVICING YOUR GENERATOR........................................................................................ 73
Smartphone application ................................................................................................... 44
Source of Emissions ............................................................................................................ 97
SPARK ARRESTER SERVICE ................................................................................................ 81
SPARK PLUG SERVICE ......................................................................................................... 79
Special Requirements......................................................................................................... 72
SPECIFICATIONS................................................................................................................ 101
STANDBY POWER................................................................................................................. 71
Starter Grip............................................................................................................................. 27
STARTING AND STOPPING THE ENGINE with Bluetooth® ENABLED
SMARTPHONE .................................................................................................................. 56
STARTING THE ENGINE ...................................................................................................... 52
STOPPING THE ENGINE...................................................................................................... 55
STORAGE PRECAUTIONS................................................................................................... 91
STORAGE PREPARATION ................................................................................................... 87
STORAGE................................................................................................................................. 87
System Ground..................................................................................................................... 71
T
TAKING CARE OF UNEXPECTED PROBLEMS............................................................... 93
Tampering and Altering.................................................................................................... 98
TECHNICAL INFORMATION .............................................................................................. 96
THE IMPORTANCE OF MAINTENANCE.......................................................................... 73
The Importance of Proper Assembly............................................................................ 14
31Z376290-A.book 125 ページ 2025年10月24日 金曜日 午後2時44分

126
INDEX
The U.S. and California Clean Air Acts, and Environment and Climate
Change Canada (ECCC)................................................................................................. 97
TRANSPORTING .................................................................................................................... 92
TYPE LOCATION.................................................................................................................... 96
U
Unpacking .............................................................................................................................. 15
V
Vehicles and Transportation Hazards........................................................................... 10
Voltage Selector Switch.............................................................................................. 30, 64
W
Wheel Kit Installation.......................................................................................................... 16
WIRING DIAGRAM............................................................................................................. 103
31Z376290-A.book 126 ページ 2025年10月24日 金曜日 午後2時44分

127
MEMO
31Z376290-A.book 127 ページ 2025年10月24日 金曜日 午後2時44分

128
MEMO
31Z376290-A.book 128 ページ 2025年10月24日 金曜日 午後2時44分

Printed in India
EU7000iS
31Z37629
00X31-Z37-6290
GENERATOR
H i
FMAH
英
PANTONE
186C
K
背幅4.6mm
EU7000iS
See page 14 for instructions on assembling your generator.
See page 19 for Initial Use Instructions.
2025 Honda Motor Co., Ltd. -All Rights Reserved
C
Owner
,
s Manual