LP-ALVRDP-BLK Lifepro Red Light Therapy Belt – Allevared Infrared Red Light Therapy for Body, Back Pain and Shoulder - 660nm & 850nm Near Infrared Heating Pad – Adjustable & Portable for Wellness & Relaxation

Product's Documents

Below are documents related to this product, you can read online or download:
LP-ALVRDP-BLK photo

User Manual

This is the main product document for model LP-ALVRDP-BLK. Additionally, the document applies to other LifePro models: 810090930930, LP-ALVRDP-BLK

The file format is pdf, 15 pages, you can download this manual here .

background
User Manual
Light Therapy Belt
AllevaRed Pro
Enjoy the Healing Power of Red Light Therapy
Professional-grade red and near-infrared light therapy.
background
0303
CUSTOMER SUPPORT
If you have any questions about setting up the AllevaRed Pro, we’re here to help.
Email us at support@lifeprotness.com and an experienced customer support
representative will be happy to assist you.
What’s in the Box? What’s in the Box?
Extension BeltStorage Bag
Lifepro AllevaRedPro Light
Therapy Belt
Connector
Plugs into USB
Power Source
Plugs into
Wall Outlet
USB Power
Cable
Power Adapter
Velcro
®
Adjustment
Strap
Pocket for 5V Power Bank
(not included; sold separately)
Power Port
105 LEDs
(660 nm red and
850 nm invisible
near‑infrared NIR)
Remote Control
Display
Screen
Output
Input
Joel and I are athletes who suffered from severe ACL injuries a few
months apart. We purchased multiple pieces of wellness equipment
for our in‑home rehab but were left disappointed and frustrated by
wellness and recovery devices that made big promises but gave
no support, no well‑thought‑out plan to follow, and no results. And
that’s how Lifepro came about, and why the Wellness collection was
created—we’ve set out to change all of that. It’s why every piece of
equipment bearing our name not only undergoes rigorous scrutiny
to make sure it delivers on power and efcacy, but also includes
ongoing member support from our Lifepro team and a lifetime
warranty so you’re never left hanging.
Welcome to Lifepro.
We’re in this together now.
Hello There!
We want you to be a part of our Lifepro crew! Join our
VIP Facebook Group and connect with people around
the world who are out there killing it, just like you.
YOUR FITNESS, YOUR WAY.
Scan Here to Join Our Community!
background
0504
1 | PREP
1. Read through all safety instructions before beginning your rst session.
2. Do a skin sensitivity test to ensure you won't experience any adverse
reactions to red light therapy. See TESTING FOR SKIN SENSITIVITY
on page 13.
2 | SET UP
1. Remove clothing and any jewelry or accessories from the treatment area.
2. Remove any protective packing material from the AllevaRed Pro Red
Light Therapy Belt and its Controller.
3. Place the belt around your waist, or other area to be treated, with the
adjustment strap in the front.
4. Use the Velcro
®
adjustment strap to secure the belt. It should be snug, but
not too tight. Attach the extension belt if you need more length.
3 | POWER
1. Plug the Output on the Remote Control into the Power Port on the belt.
2. Plug the Connector on the Power Adapter or USB Power Ccable into the
Input on the Remote Control cable.
3. The remote will light up and show the default program: 10‑minute
session, RED&NIR mode, 100% brightness, pulsed light off, and vibration
off.
4 | START
1. Press the Power button to begin a session using the default settings.
2. Adjust the time, mode, brightness level, pulse frequency, and vibration
as desired.
3. For more detailed information, review the OPERATING INSTRUCTIONS
on page 10–13.
Scan the QR code to activate the lifetime warranty for
your AllevaRed Pro within 14 days of purchase.
Scan Here Activate Your Warranty
?
QUESTIONS?
We’re here to help! Email us at support@lifeprotness.com
Quick Start Guide
Use any of the QR codes in this manual for helpful
instructions, tutorials, and other resources curated
specically for you and your AllevaRed Pro.
Scan Here
Intended Uses
This product is intended to be used:
3–5 times per week for optimal results.
Over clean skin or clothing.
To promote healing.
background
0706
Tips for Using the AllevaRed Pro
For red light therapy to work most effectively, it is best to place the
LED lights directly against your skin. However, you may use over clean,
light cotton clothing, if desired.
Place the AllevaRedPro in position on your lower back, waist, or other
area to be treated, before powering on the device.
Turn off the AllevaRedPro before removing it from the treatment area.
We recommend rst‑time users start with 2–3‑minute sessions per
treatment area. Gradually working your way up to longer treatment
sessions over a period of several weeks will allow your body to properly
acclimate to phototherapy.
Use the AllevaRedPro 3–5 times a week for optimal results. Do not use
for more than 30 minutes continuously, and wait at least 2–3hours
between sessions.
Use only over clean skin or clothing to keep the device clean.
Attach the extension belt to the AllevaRedPro if you need more length,
such as when treating your shoulder, chest, or upper back.
Disconnect the remote control cable and power adapter or USB cable
from the belt before storage or travel.
Frequently Asked Questions
Q: WHY DO SOME LEDS NOT APPEAR TO BE WORKING?
A: 850 nm near‑infrared (NIR) light is invisible to the human eye.
Q: WHERE CAN I USE THE ALLEVARED PRO?
A: While the AllevaRedPro is designed primarily for use on the waist
and lower back, it can be used on the shoulders, chest, upper back, hips,
arms, legs, feet, and hands.
CAUTION: Never use the AllevaRedPro on
your head or neck, or over your eyes, as the lights can damage your eyes.
If you want to safely experience the benets of phototherapy on your
face, check out the VizaCure Light Therapy Mask on page 19.
Q: HOW OFTEN CAN I USE THE ALLEVARED PRO?
A: See page 13 for treatment frequency and duration
recommendations.
Q: SHOULD I WEAR CLOTHING IN THE TREATMENT AREA?
A: For red light therapy to work most effectively, it is best to place
the LED lights directly against your skin. However, you may use the
AllevaRedPro over clean, light cotton clothing, if desired.
Q: HOW DO I CLEAN THE ALLEVARED PRO?
A: Turn off, unplug, and allow the device to cool down before cleaning.
Wipe the inside of the belt with a soft, dry cloth after each use.
WARNING: Never allow water or other liquids to come into contact
with the device. Do not immerse the device in water or other liquids. Do
not wash in a washing machine.
Q: WHO SHOULD NOT USE THE ALLEVARED PRO?
A: Please see the list of contraindications on page 22 for a list of
people who should not use this device. We recommend everyone
perform a skin sensitivity test before using this device.
Waist &
Lower Back
Chest &
Upper Back
Thigh
Hand
Knee
Foot
Shoulder
Arm
Hip &
Glutes
Calf
Treatment Areas
background
0908
What Are the Benets?
The benets of red light therapy and near‑infrared (NIR) therapy are very
similar, though red light therapy treats cells at the surface of the skin, and
near‑infrared therapy treats cells up to 1.5 inches below the surface of
the skin (muscles, fat, joints, and organs).
What Is Pulsed‑Light Therapy?
Pulsed‑light therapy is phototherapy that uses rapid pulses of light to
produce improved results. The device LEDs rapidly turn on and off at a
particular frequency. The frequency is a measure of the pause between
on” time and the next. For example, when a pulse frequency of 10 Hz is
selected, the light pulses on and off 10 times per second.
Emerging research shows that the short pause between light pulses
encourages cells to regenerate more efciently, which means that
pulsed light has a greater effect on cell regeneration and recovery.
What are Red Light and NIR ‑
Light Therapies?
RED LIGHT THERAPY
Red light therapy, also called phototherapy, is a therapy that uses
low‑wavelength red light at a frequency of 600–700 nm (nanometers) to
treat the body at and below the surface of the skin. Red light is absorbed
by the body's cells, particularly the mitochondria, which use red light to
make energy and stimulate cell repair and regeneration.
NEAR INFRARED (NIR) LIGHT THERAPY
Red light wavelengths, 600–700 nm (nanometers), are absorbed by
the skin at a high rate. Near‑infrared (NIR) wavelengths, 760–1400 nm
(nanometers), are higher on the electromagnetic spectrum and not
visible to the human eye. The human body easily absorbs near‑infrared
waves, up to 1.5 inches into muscle, fat, and joints.
WHAT'S THE DIFFERENCE BETWEEN
RED AND NIR LIGHT THERAPY
The AllevaRedPro's RED mode uses 660 nm red light, which is a
wavelength that is easily absorbable by the skin. NIR (near‑infrared)
mode uses 850 nm light, which penetrates deeper into tissue and
organs. RED+NIR mode uses 660 nm and 850 nm wavelengths of light
at the same time, and it treats the surface of the skin and below the skin
simultaneously.
background
1110
4. Increase and Decrease and Buttons: Press to adjust the selected
setting. For timer, set the number of minutes, from 1–30 minutes,
in increments of 1 minute. For mode, toggle through the 3 modes,
RED&NIR (650 nm+850 nm), RED (650 nm), and NIR (850 nm). For
brightness, set the level from 1–100% in increments of 1%; press and
hold for 3seconds for increments of 5%. For pulse, set the frequency
from 1–1000 Hz in increments of 1 Hz; press and hold for 3seconds for
increments of 10 Hz; press and hold for 5seconds for increments of
100 Hz. “Null” indicates a pulse frequency of 0 Hz (pulsed‑light mode
off). For vibration, toggle through the 5 vibration settings, V0(vibration
off), V1, V2, V3, V4, and V5.
NOTE: On start‑up, the home screen shows the default program:
10‑minute session, RED&NIR mode, 100% brightness, pulsed light off
(pulse frequency set to “Null”), and vibration off.
Scan now to learn more about your AllevaRed Pro.
Scan Here
Operating Instructions
Please read the operating instructions before using the AllevaRed Pro
Light Therapy Belt. Keep this manual for reference.
USING THE REMOTE CONTROL
1. Display Window: Shows the selected session time, mode, brightness
level, and pulse frequency.
2. Settings Button: Press to enter the settings menu and toggle through
the options: timer, mode, brightness level, pulse frequency, and
vibration. An orange dot indicates the selection. Use the and
buttons to adjust the selected option.
3. Power Button: Press to begin the session (either using the default
settings or after adjusting the settings). Press a second time
to pause the session and a third time to resume it.
?
QUESTIONS?
We’re here to help! Email us at support@lifeprotness.com
Timer
Mode
Level
Pulse
Vibration
V0
V0
1
4
3
2
Settings MenuHome Screen
background
1312
DETERMINING TREATMENT FREQUENCY AND DURATION
*Per treated area.
NOTE: Do not use continuously for more than 30minutes, and wait at least
2–3hours between sessions in each treated area.
Testing for Skin Sensitivity
To ensure you won't experience any adverse reactions to light therapy,
perform a sensitivity test:
1. Hold the belt to your inner arm, with the LEDs against your skin.
2. Press the Settings button once and the Decrease button ve times, until
"5 " is shown in the display window. Press the Power button to begin the
session. The AllevaRedPro will turn off automatically when the 5‑minute
session ends.
3. If your skin feels uncomfortable or too hot at any point during the test
treatment, stop using the AllevaRedPro immediately.
4. Some temporary redness and warmth are normal. If you have lasting or
excessive redness, or the heat is uncomfortable, you may be sensitive to
light therapy and you should not continue to use the AllevaRedPro.
5. Wait at least 6 hours after the sensitivity test. If your skin becomes red
and/or itchy during this time, you may be sensitive to light therapy and you
should not continue to use the AllevaRedPro.
NOTE: Please see a list of contraindications (people who should not use this
device) on page 22.
USING THE ALLEVARED PRO LIGHT THERAPY BELT
1. Place the AllevaRedPro therapy belt in position around your waist, or other
area to be treated, with the adjustment strap in the front. Ensure the LED
side of the belt faces in, toward you.
2. Use the velcro® adjustment strap to secure the belt. It should be snug, but
not too tight. Use the extension belt if you need more length, for example,
when treating your shoulder, chest, or upper back.
3. Connect the AllevaRedPro to power. The home screen will turn on, and the
settings from your last treatment will be displayed. If this is your rst use,
you will see the default treatment program settings. The default treatment
program settings are: RED&NIR mode, for 10 minutes, at 100% brightness,
with pulsed‑light therapy off.
4. Press the Settings button to toggle through the settings: timer, mode,
brightness level, and pulse frequency, if desired. An orange dot indicates the
selection. Then, use the
and buttons to adjust your desired setting(s):
a. Timer: Press the
or button to adjust the session time from
1–30minutes in one‑minute increments. 10minutes is selected by
default.
b. Mode: Press the
or button to toggle between the 3 modes,
RED&NIR, RED, and NIR. RED&NIR mode is selected by default.
c. Level: Press the
or button to adjust the brightness intensity level
from 1–100% in increments of 1%; press and hold for 3seconds for
increments of 5%. 100% is selected by default.
d. Pulse: Press the
or button to adjust the pulse frequency from
1–1000 Hz in increments of 1 Hz; press and hold for 3 seconds for
increments of 10 Hz; press and hold for 5 seconds for increments of
100 Hz. “Null” (pulsed‑light therapy off) is selected by default.
e. Vibration: Press the
or button to toggle through the 5 vibration
settings, V0 (off), V1, V2, V3, V4, and V5. V0 (vibration off) is selected by
default.
5. Press the Power button to begin the treatment session; the timer will begin
counting down. The settings can be adjusted at any time during the session.
6. Press the Power button to pause the session at any time. Press it again to
resume the paused session.
7. The AllevaRedPro will automatically shut off after the set session time ends.
Use the Power button to end the session at any time.
8. Always power off and unplug the device after each use and before removing
the AllevaRedPro belt.
9. Allow the belt to cool before cleaning or storing.
ISSUE/SEVERITY ACUTE CHRONIC MAINTENANCE
Frequency
(How Often)*
1–2 times daily 1–3 times daily 2–4 times weekly
Duration
(How Long)*
20–30 minutes 10–20 minutes 5–15 minutes
Get extra guidance, helpful information, and
resources designed to support your experience.
Scan Here
background
1514
Cleaning and Storage
WARNING:
Never allow water, other liquids, or steam to come into contact with the
remote control or power cables. Do not immerse the product, remote
control, or cables in water or other liquids.
Use a clean, dry cloth to wipe away dirt or moisture after each use.
Do not wash the product in a washing machine. Do not dry clean or
bleach. Do not use harsh detergents or abrasive, corrosive, solvent, or
chemical cleaners on this product.
Store in a cool, dry, indoor location. Do not store in direct sunlight, in a
high‑temperature or high‑moisture environment, or near heat sources.
NOTICE
Do not sit or stand on the device. Excessive force or weight applied to
the device can damage it.
Unplug the device immediately in the event of a power failure.
This device is intended for in‑home use only. Do not use in any
commercial, rental, institutional, or therapeutic setting.
Dispose of product and accessories per to state and federal
regulations.
Do not use the device continuously for more than 30 minutes.
Troubleshooting Guide
Quickly troubleshoot simple issues you might experience with your
AllevaRed Pro Light Therapy Belt using the table on the next page. Please
contact a customer support representative for additional assistance at
support@lifeprotness.com or (800) 563‑6604. Please do not attempt to
repair the device.
ISSUE POSSIBLE REASON HOW TO RESOLVE
Device is not
working.
Device is not
connected to power.
Connect the remote control cable to
the belt. Connect the power adapter
or USB power cable to the remote
control cable, and then plug the cable
into a power source.
Device is not turned
on.
Adjust the settings if desired, then
press the Power button to begin the
treatment program.
Device
stopped
working
suddenly.
Device shuts off
automatically after the
session time ends.
Turn the device on to begin a new
session.
Brightness
intensity is too
strong/weak.
The brightness
intensity selected is
not optimal.
Press the Settings button to select
Level, and use the Increase and
Decrease buttons to choose a
different brightness level from 1–100%.
Vibration
intensity is too
strong/weak.
The vibration intensity
selected is not
optimal.
Press the Settings button to select
Vibration, and use the Increase
and Decrease buttons to choose a
different vibration level from V1–V5.
Select V0 turn vibration off.
Pulsed-light
frequency or
intensity is too
high/low.
The pulse frequency
selected is not
optimal.
Press the Settings button to select
Pulse, and use the Increase and
Decrease buttons to choose a
different pulse frequency from
1–1000Hz. Select "Null" to turn
pulsed‑light off.
Pulsed-light
mode is not
working.
The pulse frequency is
set to "Null" (off).
Press the Settings button to select
Pulse, and use the Increase button
to set the pulse frequency from
1–1000Hz.
Some LEDs do
not appear to
be working.
850 nm near‑infrared
(NIR) light is not visible
to the human eye.
If the mode is set to "ALL" or "850"
some or all of the LEDs may not
appear to be on. However, as long as
the timer is counting down, the LEDs
are working.
background
17
FCC Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
NOTE: Changes or modications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Industry Canada Compliance
Statement
This device complies with Industry Canada licence‑exempt RSS standard(s).
Operation is subject to the following two conditions: (1) This device may not
cause interference, and (2) This device must accept any interference, including
interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’ Industrie Canada applicables aux
appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions
suivantes : (1) l’utilisateur de l’appareil ne doit pas produire de brouillage, et (2)
l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage
est susceptible d’en compromettre le fonctionnement.
16
Product Specications
UNIT SPECS
Size:
49.5 × 7.7 in | 125.7 × 19.5 cm
Net Weight:
0.9 lbs | 0.41 kg
Belt Circumference:
8–43 in | 20–109 cm
Power:
21 +/‑ 10% W
Total LEDs:
105 Triple‑LED Chip Sets
LED Wavelengths:
660 nm Red: 105
850 nm Near-infrared (NIR): 210
Irradiance:
>9 W/ft
2
| >96.88 W/m²
LED Life Expectancy:
50,000 hrs
Timer:
1–30 minutes
Modes: 3
Vibration Levels: 5
Operating Temperature:
32–113 °F | 0–45 °C
External Battery:
Supported
DC USB ADAPTER CABLE
Rated Input:
DC 5.0 V
Rated Output:
DC 12 V
AC POWER ADAPTER*
Rated Input:
AC 100–240 V ~50/60 Hz
Rated Output:
DC 12 V–2 A
*Can be used with a standard mobile phone 5 V–1 A or 5 V2 A USB
charging adapter. WARNING: Do NOT use with a 12 V USB charging
adapter.
EXTERNAL BATTERY*
Rated Input:
DC 5 V–4 A
Rated Output:
DC 5 V
*Not included; sold separately from lifeprotness.com.
background
VizaCure Page
From Our Vibration Collection:
Waver Vibration Plate
Step onto the Lifepro Waver and take your wellness routine to the next
level. This easy‑to‑use vibration platform is designed to support your
tness goals by encouraging movement, muscle activation, and gentle
stimulation—all with minimal impact.
Highlights:
Built for Flexibility
Includes mini bands and handled resistance bands for a variety of
workout options—from light stretching to upper‑body resistance moves.
ENHANCES
STABILITY
FULL-BODY
ACTIVATION
LOW-IMPACT
EXERCISE
CUSTOM
INTENSITY
The Waver’s gentle, rhythmic vibrations help stimulate your body through
repeated muscle engagement, making it a great tool for complementing
your existing workout routine or recovery regimen.
From Our Wellness Collection:
VizaCure Light Therapy Mask
Get radiant skin without leaving home. The VizaCure Light Therapy
Mask delivers professional‑grade skincare using safe, non‑invasive LED
technology—no chemicals, no downtime. With 3 targeted light modes,
this hands‑free mask supports your skin’s natural rejuvenation process
and promotes a more balanced, refreshed appearance.
Key Features
3‑in‑1 LED Technology – Red (refreshes),
Blue (evens skin tone), and Amber (supports
sensitive skin).
Hands‑Free Design – Comfortable, wearable
mask with no need to hold or adjust.
What it does best:
SUPPORTS SKIN
VITALITY
ENHANCES
SKIN GLOW
REFRESHES SKIN
APPEARANCE
1918
background
From Our Wellness Collection:
RejuvaWrap Infrared Sauna Blanket
Skip the spa—and still get the glow! With the Lifepro RejuvaWrap, you
can experience all the benets of infrared therapy from the comfort of
your home. No memberships, no travel, no hassle.
This sweat‑resistant, non‑toxic sauna blanket uses carbon ber heating
wires to deliver powerful far‑infrared waves that promote deep warmth
and total‑body relaxation.
What it does best:
Fully Customizable Wellness:
Choose from 9 heat levels and set your session time anywhere from 5 to
60 minutes. Use it 3–4 times a week for 30 minutes to feel the difference
and enjoy a more consistent wellness routine.
SUPPORTS
DETOX PROCESS
PROMOTES
CIRCULATION
SUPPORTS
SKIN HEALTH
WELLNESS
ROUTINE BOOST
From Our Wellness Collection:
BioRecover Light Therapy Knee Brace
Targeted self-care, made simple.
Highlights:
ENHANCES
RELAXATION
SUPPORTS DAILY
COMFORT
AIDS ACTIVITY
RECOVERY
GENTLE SENSORY
STIMULATION
Recover with ease using the Lifepro BioRecover Light Therapy Knee
Brace is a compact, all‑in‑one wrap designed to bring comfort and
exibility to your wellness routine. With 60 dual‑wavelength LEDs
(660nm red + 850nm near‑infrared) and a wraparound design, it delivers
targeted light to both surface and deeper layers—helping to soothe
overworked areas and support your daily recharge. Use it on knees,
elbows, arms, feet—even your pets—with adjustable Velcro® straps and a
exible t that moves with you.
Personalized Post-Activity Recovery
Customize each session with 5 light intensities, 5 vibration levels, and
3light modes, including an optional pulsed‑light setting.
2120
background
2322
Safety Instructions
Before using this product, read all safety warnings and operating
instructions. Failure to do so may result in burns, re, electric shock,
serious injury or death, or damage to the product or property. Keep this
manual in a safe place for future reference.
NOT INTENDED FOR
This product is not intended to be used:
If you had a negative reaction to the skin sensitivity test.
On open or bleeding wounds, or infected, bruised, swollen, inamed,
or sunburned skin.
If you take or use any topical or oral medication or products that may
cause photosensitivity.
CONTRAINDICATIONS
This product is intended for use by people in good health.
Do not use this product if you:
Have open or bleeding wounds. Do not use over infected, bruised,
swollen, inamed, or sunburned skin.
Have cancer, or suspect you may have cancerous lesions in the
treatment area. Do not use over malignant or benign tumors.
Consult with your physician before using this product if you:
Are under the care of a physician for a pre‑existing health condition.
Have ever had (or anyone in your household has ever had)
symptoms related to epilepsy, such as seizures or loss of
consciousness, when exposed to ashing lights.
Are pregnant, suspect you may be pregnant, or if you have recently
given birth.
Take steroid medication, use a topical steroid, or receive
steroid injections.
Have poor blood circulation, peripheral neuropathy dysfunction, or if
you have sensory deciencies, including an impaired ability to sense
external temperature or elevated body temperature.
Have a condition that may make you sensitive to light or sunlight,
such as Lupus, some forms of eczema, light‑induced migraines,
albinism, and rosacea.
Take a topical or oral medication that may cause photosensitivity,
including some antibiotics, antifungals, antidepressants,
antipsychotics, oral contraceptives, psoralens, cardiac, diabetic,
blood pressure, and cholesterol medications, chemotherapy drugs,
pain medications, nonsteroidal anti‑inammatory drugs (NSAIDs),
diuretics, cold and allergy medications, and retinoids (such as
Retin‑A and Retinol).
Use a product that may cause photosensitivity, such as
alpha‑hydroxy acids (like glycolic acid), beta‑hydroxy acids (like
salicylic acid), Retin‑A and Retinol, melatonin, citrus essential oils,
St. John’s Wart, acne products, antibacterial soap, and coal tar and
petroleum products.
Have recently had surgery, LASIK or PRK eye surgery, or skin ller
injections, if you have breast implants, or if you have a tattoo in the
treatment area.
Have a skin disorder, including inammatory skin disorders, or
sensitive skin.
Are or may be sensitive to red light or near‑infrared light.
DISCLAIMER
This product is not a medical device. This product and the information
in this manual are not intended to diagnose, treat, cure, or prevent any
disease or medical condition. The health benets suggested or implied
in this manual, other product literature, and company website are not
certied or endorsed by any regulatory authority or medical institute.
The information in this document is not a substitute for expert medical
care or advice.
The use of this product is entirely at the user’s discretion. Please
read all instructions and safety information carefully before using
this product. We assume no responsibility and expressly disclaim any
and all liability for personal injury, death, or property damage or loss
sustained through improper use, failure to follow the instructions and
warnings in this manual, inadequate or improper maintenance, or
neglect of this product.
It is the responsibility of the owner to ensure that all users of this
product are adequately informed of all warnings and cautions.
Use this product only as instructed in this manual.
background
2524
WARNING
To reduce the risk of burns, re, electric shock, serious injury or death, or
damage to the product or property:
Only use the provided power adapter and USB power cable at the
specied voltage to power the device. Using power adapters or cables
other than the ones provided may result in re or explosion.
Do not use the provided power adapter or USB power cable to power
other devices.
Do not modify, tamper with, or damage the power adapter or
USB cable.
Never unplug the power adapter by pulling on the cord.
Never use a modied or damaged power adapter or USB cable to
power the device.
Do not modify, tamper with, damage, or attempt to disassemble the
device. This device has no user‑serviceable parts.
Always inspect the device, remote control, and power cables for
damage, wear, or fraying before each use. Do not use if damaged,
malfunctioning, or if the device has been exposed to water.
Keep the device, remote control, and power cables away from
ammable or explosive items, chemicals, re, heat sources, and
direct sunlight at all times. Do not use or charge in high temperatures
or direct sunlight. Do not use or charge under a blanket or pillow.
Excessive heat can cause a battery explosion, re, electrocution,
serious injury, death, or property damage.
Do not operate in the presence of aerosol (spray) products or
corrosive gases, or where concentrated oxygen is being administered.
Keep away from liquids. Do not use outdoors, in high‑moisture
environments or in any place where the device may become wet. Do
not immerse in water. If the device becomes wet, do not use.
Do not touch the device, power adapter, or USB cable with wet hands.
Do not use the device over wet skin or clothing.
Do not use during electrical storms.
Keep sharp objects away from the device, accessories,
and power cables.
Do not use the power adapter or USB cable with an extension cord.
Never leave the device unattended while running or plugged in.
Unplug the device after use.
Pulsed‑light therapy may affect users who are susceptible to
photosensitive epilepsy or other photo‑sensitivities. If you or anyone in
your household experience symptoms during use, such as dizziness,
blurred vision, eye or muscle twitching, loss of consciousness,
disorientation, involuntary movements, or convulsions, stop using the
device IMMEDIATELY and consult your physician.
Stop using the product immediately if you feel pain or discomfort.
Do not operate the device while sleeping, driving, smoking, or under
the inuence of drugs or alcohol.
Do not use this product on sleeping or unconscious people or infants.
For adult use only. Keep away from children and pets.
This device is not intended for use by adults with diminished mental,
sensory, or physical capacity unless they are closely supervised by a
responsible adult.
CAUTION
To reduce the risk of minor or moderate injury:
Do not use creams, ointments, oils, salves, liniments, balms, or other
topical products that contain ingredients that produce heat (such as
pain‑relievers containing capsaicin) before using the product, as this
may result in skin irritation or burns.
Do not wear metal accessories, such as snaps, buttons, zippers, belts,
or jewelry, as the metal may heat and cause skin irritation or burns.
Metal accessories can also damage the device or power cables.
Do not use the device over the eyes, head, or neck.
Do not look directly into the LED lights while the device is powered on.
Looking directly at infrared lights may result in damage to the eyes.
Do not stop your traditional pain treatment without rst discussing
with your physician (some medications may have withdrawal side
effects) and experiencing long‑term relief.
Keep hair away from the device to avoid getting it caught in
the Velcro®.
background
Lifepro Fitness creates quality, durable
exercise products and we stand by that
quality with a lifetime warranty on all of our
products.
If your product ever breaks (and we doubt it
will), we’ll send you replacement parts and
show you how to repair it. If the product
cannot be repaired, we’ll replace it—free of
charge.
Register the AllevaRed Pro
at
allevaredpro.lifeprotness.com to activate
your warranty within 14 days of purchase.
Lifetime
Warranty
26 27
AllevaRed Pro
Light Therapy Belt
EXPERIENCE THE POWER OF
RED + NEAR-INFRARED
LIGHT THERAPY
VERSATILE
DESIGN
ENHANCES
RELAXATION
AIDS ACTIVITY
RECOVERY
SUPPORTS
DAILY COMFORT
background
251211
Congratulations on your purchase!
We're excited to be part of your wellness journey.
Scan the QR code to enjoy
15% off
your next Lifepro® product.
Meet Our Best Seller!
Waver Vibration Plate
Support movement, strength, and recovery from day one—whether you're
warming up, cooling down, or establishing a steady tness routine.
Low Impact, High Efciency
The Waver adapts to your pace and goals, helping activate muscles, enhance
stability, and keep you moving. Whether you're a seasoned athlete or just
getting started, this powerful platform empowers you to build a balanced,
active lifestyle—one invigorating vibration at a time.
Lifeprousa Lifeprousa support@lifeprotness.com
*Discount valid on purchases of $150 or more.

Specifications

Indexed Terms: Infrared Heating Pad

LifePro LP-ALVRDP-BLK Questions and Answers

Questions and Answers

Related Products