
SOI 1010SL
EN
ORAL IRRIGATOR
Translation of the original manual

SOI 1010SL

A
1
2
3
4
6
5
7

B
C

- 1 -
10/2025
2025, .
EN
Oral irrigator
User Manual
IMPORTANT SAFETY
INSTRUCTIONS
READ CAREFULLY AND STORE FOR
FUTURE USE.
• Oral irrigators may be used by children 8 years of age and older and by persons with physical,
sensory or mental impairments or by inexperienced persons, if they are properly supervised.
• Children must not play with the appliance. Cleaning and maintenance must not be performed by
unsupervised children.
• If the charging cable is damaged, have it replaced in aprofessional service centre in order
to prevent adangerous situation. It is forbidden to use the appliance with the charging cable
damaged.
• Oral irrigators must only be used with cold or hot water or with special solutions defined inthis
manual.
• Parts of the appliance that need to be fixed or erected must be fixed or erected in such away that
they cannot fall into the water.
Caution:
To avoid the risk of asudden resetting of the thermal fuse, this appliance must not
be supplied via an external switching device such as atimer or be connected to
acircuit with regular on/off switching.
• The appliance may only be powered using asafe small voltage corresponding to the designation
on the rating label of the appliance.
• The power adapter is not supplied.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Safety
• Do not place the power cord over sharp objects. Make sure that the cable does not hang over the
edge of atable or touch ahot surface.
• Never use the charging cable supplied withthis appliance for other purposes.
• Keep the charging cable dry.
• Do not wind the charging cable around the handle of the appliance.
• Do not connect or disconnect the charging cable with wet hands.
• Before connecting the appliance to apower socket, check that the nameplate rated voltage
matches the voltage of the power socket the appliance is to be connected to. Do not use an
extension cord.
• Store, charge anduse the appliance at an ambient temperature of 15 °C to 35 °C. Do not charge
the appliance for longer than necessary to fully charge it. After charging, disconnect it from the
power source.
ORAL IRRIGATOR

- 2 -
10/2025
2025, .
• Do not expose the appliance to temperatures above 50°C. Otherwise damage to the built-in
battery may occur.
• The appliance is equipped with abuilt-in battery with along service life, which can only be
removed by aprofessional service. Never attempt to remove it from the appliance aswitch for
anew one by yourself.
Warning:
Never disassemble the appliance in order to remove the battery. Do not short-
circuit the appliance or throw it into afire. There is arisk of leakage of toxic
substances, fire or explosion if improperly handled.
• Do not charge, use, store or leave the appliance in abathroom or any place where it could fall into
abathtub, wash basin or any other container filled withwater.
• If the appliance was connected to amains socket via power adapter and it falls into water,
underno circumstances should you touch it, but immediately disconnect the power adapter from
the socket.
Safety in Use
• This oral irrigator is designed exclusively for thecleaning of teeth and the oral hygiene of people.
The oral irrigator is not intended for commercial purposes or forbrushing animals' teeth.
• Use the oral irrigator and its individual attachments in accordance with the instructions in this
manual.
• If you have recently undergone intensive surgery such as tooth or gum surgery, have had long-
term dental problems, or if you suspect dental problems (fillings, crowns, etc.), consult your dentist
before using the oral irrigator.
• If you experience bleeding gums after using the oral irrigator and if the bleeding persists after 2
weeks of use, contact your dentist.
• In case of any health concerns, contact your dentist before using the oral irrigator.
• If any damage to the oral irrigator (handle or mains adapter) occurs, stop using it.
• Use only the original accessories supplied with this oral irrigator. Do not use attachments other
than those supplied by the manufacturer.
• The oral irrigator andits power adapter must only be used indoors. Do not use them outdoors.
• Avoid using the oral irrigator inrooms where aerosol dispensers are used or where oxygen is
administered.
• Do not expose the oral irrigator and its accessories to the outdoor environment, extreme
temperatures, direct sunlight, excessive humidity or excessive dust.
• Do not place the appliance and its accessories near heaters, open fire or other sources of heat.
Warning:
Keep the oral irrigator dry.
• Before each use, make sure that the oral irrigator and its accessories are not damaged. Never use
an oral irrigator with adamaged attachment.
• The oral irrigator may heat up when used or recharged. This is completely normal.
• Do not apply too much pressure to the end of the nozzle attachment.
• To avoid injury, do not fill the tank with hot water. Do not insert any objects into the tank.
• Do not point the nozzle of the attachment under the tongue, in the ear, nose, eyes or other
sensitive areas, as this could cause injury.

- 3 -
10/2025
2025, .
• Do not clean thenozzle attachments, the handle, the mains adapter or the water tank in
thedishwasher or microwave.
• Always switch off and unplug the oral irrigator when not in use, when left unattended and before
attaching, removing or replacing the attachment, cleaning, maintenance or storage. Store the oral
irrigator andits mains adapter inadry environment.
• Keep the oral irrigator clean. Perform the cleaning and maintenance following the instructions in
the Cleaning and Maintenance section.
• Do not perform any maintenance on the oral irrigator other than cleaning its individual components
as described in the Cleaning and Maintenance chapter.
• Do not use the oral irrigator if it has been dropped on the floor, does not function properly or is
damaged in any way.
• To avoid ahazardous situation, do not repair or modify the oral irrigator or its accessories yourself.
Contact an authorised service centre for all repairs. Tampering with the appliance may result in the
loss of your legal rights regarding faulty performance or warranty for quality.
Special Safety Instructions for the Li-ion Battery
• The Li-ion battery is built into the oral irrigator andis an integral part of it, which the user is not
allowed to remove.
• Follow all the instructions provided in this user'smanual.
• Inthe event of abattery fluid (electrolyte) leak, do not touch the battery with your bare hands.
Use protective aids (gloves, aprotective mask, goggles, etc.). The liquid inside the battery is toxic
andmay cause health problems even with slight contact of the bare skin withit.
• We recommend opening windows or doors to ensure adequate ventilation of the space.
• Contact aspecialist hazardous waste disposal company or use ahazardous waste collection
facility. Do not dispose of the damaged battery or accumulator in ordinary household waste.
• In case of skin or eye splashes, rinse with plenty of water and seek medical attention. If ingestion
occurs, seek immediate professional medical help.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
EXPLANATION OF SYMBOLS PLACED ON THE PRODUCT OR INTHE
ACCOMPANYING DOCUMENTATION
The product meets all the basic requirements of the applicable EU directives.
This symbol on products or accompanying documents means that used electric or
electronic products must not be added to ordinary municipal waste.
This symbol on the accumulator or battery means that the used battery must not be
added to normal municipal waste.
Protection level against harmful water ingress:
IPX7 – The device is protected against harmful ingress of water when submerged to
adepth of 1 meter for aperiod of 30 minutes.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

- 4 -
10/2025
2025, .
• Thank you for purchasing our SENCOR product; we hope it will serve to your satisfaction.
• Prior to using this appliance, please read the user manual thoroughly, even in cases when you are
already familiar with the use of similar types of appliances. Use the appliance only as described
in this user manual. Keep the manual for future reference. If you pass the appliance on to another
person, ensure that this user manual is included.
• Carefully unpack the appliance and make sure not to discard any part of the packaging material
until you have removed all its components. It is recommended that you keep the original
packaging, packing material, receipt and confirmation of the extent of the seller'sliability or
warranty certificate at least for the duration of the legal right to file adefect claim or the quality
warranty. When transporting the appliance, we recommend repackaging it in the original box
provided by the manufacturer.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DESCRIPTION OF THE ORAL IRRIGATOR
A1 Standard attachment with nozzle (1 pc)
A2 Nozzle attachment release button
A3 On/Off button
A4 Water tank
A5 Charging socket with cover
A6 Orthodontic attachment (1 pc)
A7 Charging cable
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INTENDED USE
• The oral irrigator is designed only fororal hygiene. It helps toremove bacteria from the interdental
spaces and the folds of the gum around the teeth, quickly andgently removes food debris from
the interdental spaces, while effectively massaging your gums. Incombination withcareful
brushing, it helps you to actively care for thehealth of your teeth. The oral irrigator is intended for
household use and is not designed for commercial or other professional applications.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BEFORE FIRST USE
• Wash the appliance under running water.
• Rinse the water tank above the sink several times andfill it with clean water according to chapter
Filling the Water Tank. Insert the attachment into the oral irrigator according to the chapter
Attaching andRemoving the Attachment. Point the nozzle of the attachment into the sink andturn
on the oral irrigator with the
button. Select one of the modes andlet the water flow through the
nozzle for awhile to flush both the suction tube and the nozzle of the attachment.
• Pour the remaining water out of the tank andleave the filling hole cover open to allow the tank to
dry out.
• Wipe the oral irrigator with adry cloth.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CHARGING THE ORAL IRRIGATOR
• The oral irrigator is equipped with abuilt-in Lithium-ion battery that serves as an internal power
source andallows cordless operation of the oral shower. Allow the battery of the oral irrigator to
fully charge first before first use or after along period of non-use. It takes about 3.5hours to fully
charge the battery. Use only the original supplied charging cable to charge.
EN
Oral irrigator
User Manual

- 5 -
10/2025
2025, .
• Remove the charging socket cover andconnect the connector of the charging cable to it. Plug the
loose terminal into asuitable mains adapter (not included).
• While the oral irrigator is charging, the charging indicator flashes. When it stops flashing and turns
off, the oral irrigator is fully charged.
• Disconnect the cable from the power socket andthe charging source. Slide the cover back into
the slot.
• If the charging indicator flashes during operation of the oral irrigator, this means that the oral
irrigator is almost discharged and needs to be recharged.
Caution:
There must be no moisture around the charging socket or its cover. Therefore, it
is recommended to wipe the area with adry cloth before plugging in the charging
cable.
Caution:
Do not leave the oral irrigator connected toan external power source longer than
it takes to fully charge it.
Note:
During charging, the use of the oral irrigator is blocked andcannot be started.
• Recommendations on how to achieve the longest possible battery life:
– To keep the built-in battery working for as long as possible, charge, use andstore the oral
irrigator at an ambient temperature of 15–35 °C inadry environment. Lower or higher
temperatures adversely affect the life of the battery.
– Do not wait until the battery is completely discharged. It is better to recharge the battery before
it is fully discharged.
– If you do not use the oral irrigator for along time, charge the battery at least once every 6 months.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FILLING THE WATER TANK
1. Open the tank filler cap.
2. Pull the water tank downwards until the water level indicator appears – see figure B.
3. Hold the oral irrigator in ahorizontal position and pour clean water into the tank.
4. Close the cover properly and then you may return the oral irrigator to avertical position.
Caution:
The water should be at acomfortable temperature. Do not use water hotter than
40 °C.
Note:
Open the filler cap BEFORE pulling the water tank downwards. Otherwise it may be
difficult to pull the tank down due to overpressure.
Tip:
• In addition to clean water, you can also use mouthwash or its solution to fill the water tank. Using
amouthwash makes using oral irrigator even more effective. However, do not use mouthwashes
containing isopropyl myristate or ahigh concentration of essential oils. These substances are
included in themouthwashes sold in glass andceramic containers andcould damage the

- 6 -
10/2025
2025, .
water tank as well as the internal parts of the oral irrigator. Mouthwashes containing substances
harmless to the oral irrigator are sold inplastic containers.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ATTACHING ANDREMOVING THE ATTACHMENT
• Insert the attachment perpendicularly into the opening at the top of the oral irrigator until you hear
aclick. Hold the oral irrigator so that the button is not pressed.
• To remove the attachment, press and hold button A2 and pull the attachment straight up out of
the opening.
Caution:
Do not remove the attachment while the oral irrigator is in operation.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OVERVIEW OF OPERATING MODES
• The oral irrigator is equipped with three operating modes:
– Pulse mode: water flows out in short intervals, which is ideal for cleaning and massaging teeth
and gums;
– SOFT mode: low water flow for gentle cleaning; suitable for people with sensitive teeth and
those using an oral irrigator for the first time;
– Normal mode: suitable for everyday use.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
USE OF THE ORAL IRRIGATOR (FIG. C)
• Check that the oral irrigator is properly assembled, charged and the water tank is full.
• Brush your teeth andgums and rinse your mouth with clean water.
1. Slide the attachment into the open mouth andlean over the sink so that water andrinsed food
remains can flow out.
2. Turn on the oral irrigator with the
button.
3. To change the mode, press the button repeatedly within 5 seconds of switching on the oral
irrigator. The indicator light for the selected mode will illuminate.
4. Direct the stream of water to the place you want to spray, i.e. to the interdental spaces, the edges
of your teeth or to your gums.
5. Move the attachment nozzle slowly fromone interdental space to another. In this way, clean all
the outer andinner sides.
6. Thoroughly spray around braces, crowns andbridges.
7. When massaging the gums, aim the nozzle perpendicularly to the gums andspray the gum line.
8. The oral irrigator is equipped with atimer that automatically turns it off after 1.5 minute of
operation. If you need to switch off the oral irrigator earlier, press the button.
9. Remove thenozzle attachment from the mouth when the oral irrigator is switched off.
Caution:
Make sure the attachment is not damaged before each use. Never use an oral
irrigator with adamaged attachment.
Note:
The oral irrigator will start in themode in which it was used for more than 10seconds
before you last turned it off.

- 7 -
10/2025
2025, .
• As soon as no water comes out of the nozzle, the water tank is empty. Turn off the oral irrigator
with
button and add water following the instructions in the "FILLING THE WATER TANK"
section. When the oral irrigator is turned on again, it will automatically start in thelast selected
mode.
• When used for the first time, it'srecommended to use the Soft operating mode.
Caution:
During the first few uses of the oral irrigator, you may notice slight bleeding from
thegums. This is normal and usually disappears after 1 to 2 weeks.
Caution:
Consult the use of an oral irrigator with your attending physician if you notice
heavy bleeding from the gums, have undergone amedical procedure in the oral
cavity, have an injured gum or an open wound inthe oral cavity.
Caution:
Do not use an oral irrigator if it causes you pain, discomfort, dizziness or vomiting.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CLEANING AND MAINTENANCE
Caution:
Toclean the oral irrigator, use water up to 50 °C or neutral cleaning agent. Do
not use wire cloths, abrasive cleaners, thinners, etc. for cleaning to prevent the
cleaned surface from being damaged. When cleaning, do not immerse the oral
irrigator in water.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WATER TANK
• Open the tank filler cap and pour out the remaining water from the tank. Close the cap.
• Start the oral irrigator to remove residual water from the tank and hose. When water stops flowing
out, switch off the oral irrigator.
• Open the tank filler cap and allow the tank to dry out.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ORAL IRRIGATOR
• Wipe the oral irrigator with aclean, dry cloth. Inthe event of heavy soiling, you can use aslightly
damp cloth. Clean the surface then properly wipe dry.
Caution:
The upper part of the oral irrigator in which the battery is stored is not intended for
washing under the tap. Do not spray the oral irrigator and the charging cable with
water or any other liquid or submerge it in water or any another liquid.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

- 8 -
10/2025
2025, .
ATTACHMENTS
• Rinse the used attachments with water after each use to avoid the formation of deposits. Then
wash the surface of the attachment with water andthen always wipe it dry with asoft cloth.
Forhygiene reasons, we recommend replacing the used attachments with new ones every six
months.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
REMOVING CALCIUM DEPOSITS
• Dependingon the mineral content of theused water, hard water deposits may accumulate in the
tank, in the suction hose or extension and in the nozzle. These can negatively affect the operation
of the oral irrigator andreduce its performance. It is therefore important to remove deposits
regularly.
• To remove mineral deposits, proceed as follows:
1. Empty the water tank andpour clean warm water into it (max. temperature 85 °C).
2. Point the attachment with the nozzle into the sink andstart the oral irrigator.
3. Let the contents of the tank be emptied completely.
4. Repeat the procedure if needed.
• Dependingon the degree of hardness of the water you use, repeat the deposits removal process
every 1–3months to maintain the performance of your oral irrigator.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
STORAGE
• After use, prepare the oral irrigator as instructed in the CLEANING ANDMAINTENANCE chapter.
Store the oral irrigator in adry place away from direct sunlight. If you want to put the oral irrigator
away for along time, we recommend removing the water tank from thehandle.
Troubleshooting
Problem Possible cause Solution
Water escapes
from thespace
between the end
of the attachment
and the body of
the oral irrigator.
The sleeve gasket is
damaged or worn.
Have the gasket replaced or replace the
nozzle.
The attachment is not
correctly fitted.
Remove the attachment andreattach it.
Water is leaking
from the tank.
The filler cap is not properly
closed.
Close the filler cap.
Water pressure is
too low.
The nozzle is clogged
with dirt.
Please clean or replace the nozzle.
The nozzle is deformed. Change the nozzle.
The oral irrigator is not
sufficiently charged.
Allow the oral irrigator to charge.
The oral irrigator
does not work
when unpacked.
The oral irrigator is not
sufficiently charged.
Allow the oral irrigator to charge.
Water is not
splashing out of
the oral irrigator.
The water tank is empty. Please refill water.
The irrigator is too tilted
when used.
Keep the irrigator in avertical position as much
as possible.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

- 9 -
10/2025
2025, .
TECHNICAL SPECIFICATIONS
Oral irrigator
Dimensions incl. attachment (H × D × W) ..................................................................................135 x 45 x 70 mm
Weight incl. attachment ........................................................................................................................................... 235 g
Tank volume ...............................................................................................................................................................120 ml
Pump frequency .................................................................................................................................1,600 pulses/min
Water pressure.................................................................................................................................................30–90 PSI
Charging time ....................................................................................................................................................... 3,5 hours
Operating time.................................................................................................................................................. 40 minutes
Protection level against harmful water ingress....................................................................................................IPX7
Built-in battery
Type ............................................................................................................................................. Li-ion 1,100 mAh, 3.7 A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BATTERY DISPOSAL
• Before disposing of the product or returning it to adesignated collection point, ensure that the
battery is removed. The battery contains environmentally harmful substances. Proper disposal
shall be ensured by the relevant collection point.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INSTRUCTIONS AND INFORMATION ON DISPOSAL OF USED
PACKAGING MATERIAL
Dispose of used packaging material at the designated municipal waste disposal site.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DISPOSAL OF USED ELECTRICAL AND ELECTRONIC EQUIPMENT
Used electrical andelectronic products must not be disposed of in ordinary municipal waste. To
enable the proper disposal, renewal and recycling of these products, deliver them to the designated
collection points. Alternatively, in some European Union states or other European countries the
products can be returned to the local retailer when buying an equivalent new product. By disposing
of this product correctly, you help to conserve valuable natural resources and prevent any potential
adverse impact on the environment and human health that could result from improper waste disposal.
For more details, contact your local authority or nearest collection point. Fines may be imposed for the
improper disposal of this type of waste as per national regulations.
For business entities in European Union States
If you wish to dispose of electrical and electronic equipment, please request the necessary
information from your retailer or supplier.
Disposal in other countries outside the European Union
To dispose of this product elsewhere, request the necessary information on the correct disposal
method from local authorities or your retailer.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Changes to text and technical parameters are reserved.
