Honda WSP50

Product's Documents

Below are documents related to this product, you can read online or download:
WSP50 photo

Owner's Manual WS5A 6300001 - 9999999

This is the main product document for model WSP50. Additionally, the document applies to other Honda models: WSP50AA

The file format is pdf, 24 pages, you can download this manual here .

background
Printed in U.S.A
POM31WSP813
MID.250.2018.10
© 2022 American Honda Motor Co., Inc.—All Rights Reserved
SUBMERSIBLE PUMP
Owner’s Manual
WSP50AA • WSP100AA
BY:
Printed on
Recycled Paper
WSP50AA
WSP100AA
background
Thank you for purchasing this Honda Stainless Steel Sump Pump. We
hope you are pleased with your purchase and that our pumps will
provide you with long service life and exceptional performance.
To ensure satisfactory service life, there are several considerations
regarding proper installation, operation, and power source. Please
review the recommendations outlined within this operator's manual.
Please contact your supplier (supplying dealer or contractor) if service
is necessary or if you have any questions or need further assistance.
Please retain the following information for your records and to help
expedite service:
Purchase Date: __________________________________
Purchased From: __________________________________
__________________________________
Serial No: __________________________________
(Located on the pump nameplate)
IFC.fm Page 1 Tuesday, March 6, 2018 4:18 PM
background
USE AND MAINTENANCE INSTRUCTIONS
1. MANUFACTURER AND PUMP IDENTIFICATION DATA
1.1 MANUFACTURER DATA
EBARA INTERNATIONAL CORPORATION
1651 CEDAR LINE DRIVE
ROCK HILL, SC 29730
2. INFORMATION ON TECHNICAL ASSISTANCE
If the malfunction of the pump is not among those included in the
troubleshooting table (see “14.2 TROUBLESHOOTING ” on page 10),
contact the nearest authorized Honda pump dealer.
3. INTRODUCTION
This publication contains all the necessary information and instructions for
use and maintenance of your submersible sewage pump. Follow the
advice given to obtain optimum performance and correct operation of the
pump. For any other information you may require, please contact the
nearest appointed distributor.
IT IS STRICTLY FORBIDDEN TO REPRODUCE THE ILLUSTRATIONS
AND THE TEXT, EVEN IN PART.
1.2 PUMP DATA
Description:
Model:
Year of manufacture:
SUBMERSIBLE SOLIDS PUMP
WSP50AM, WSP50M, WSP100AM, WSP100AA
See plate on the pump.
POM31WSP817.2022.05
1
background
2
4. CONTENTS
1. MANUFACTURER AND PUMP IDENTIFICATION DATA. . . . . . . . . . . . .page 1
1.1 MANUFACTURER DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 1
1.2 PUMP DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 1
2. INFORMATION ON TECHNICAL ASSISTANCE . . . . . . . . . . . . . . . . . . .page 1
3. INTRODUCTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 1
4. CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 2
5. GENERAL SAFETY WARNINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 3
5.1. PREVENTIVE MEASURES TO BE TAKEN BY THE USER . . . . .page 3
5.2 GENERAL SAFETY WARNINGS . . . . . . . . . . . . . . . . . . . . . . . . . .page 3
6. GENERAL DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 4
7. TECHNICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 4
7.1. PUMP TECHNICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 4
7.2. MOTOR TECHNICAL DATA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 5
8. RECOMMENDED AND NON-RECOMMENDED USE. . . . . . . . . . . . . . .page 5
8.1 RECOMMENDED CONDITIONS OF USE . . . . . . . . . . . . . . . . . . .page 5
8.2 NON-RECOMMENDED CONDITIONS OF USE. . . . . . . . . . . . . . .page 6
9. HANDLING AND TRANSPORT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 6
9.1 UNPACKING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 6
9.2 HANDLING AND DISCONNECTING. . . . . . . . . . . . . . . . . . . . . . . .page 6
9.3 TRANSPORT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 7
10. INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 7
10.1. FIXED INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 7
10.2. TEMPORARY INSTALLATION (FOR TEMPORARY USE) . . . .page 7
11. ASSEMBLY AND DISASSEMBLY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 8
12. PREPARATION FOR USE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 8
12.1. ELECTRIC CONNECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 8
12.2. ADJUSTING AND REGISTERING . . . . . . . . . . . . . . . . . . . . . . .page 8
13. USE AND START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 8
14. MAINTENANCE AND REPAIRS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 9
14.1 MAINTENANCE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 9
14.2 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 10
15. ILLUSTRATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 11
15.1 INSTALLATION WITH MINIMUM FUNCTIONAL SPACES . . . .page 11
15.2 PUMP IMPELLER COVER DISASSEMBLY . . . . . . . . . . . . . . . .page 12
15.3 WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 13
16. WARRANTY SERVICE INFORMATION. . . . . . . . . . . . . . . . . . . . . . . .page 14
17. DISTRIBUTOR’S LIMITED WARRANTY . . . . . . . . . . . . . . . . . . . . . . .page 15
background
3
5. GENERAL SAFETY WARNINGS
FAILURE TO OBSERVE THESE WARNINGS AND/OR TAMPERING
WITH THE PUMP RELIEVES THE MANUFACTURER OF ANY
RESPONSIBILITY IN THE EVENT OF DAMAGE TO PERSONS OR
OBJECTS AND/OR TO THE PUMP.
Before starting the pump it is important for the user to know how to perform all
the operations described in this manual and
to apply them at all times during
use
or maintenance of the pump.
5.1. PREVENTIVE MEASURES TO BE TAKEN BY THE USER
The user must comply with all the accident-prevention regulations
in force in the country in which the pump is being used; the
indications given in chapters 7.1 and 7.2 must be scrupulously
followed.
During pump repairs or maintenance, remove the plug from the
socket and/or turn off the switch (if provided), thus interrupting the
supply of electric power to the pump. This will prevent accidental
starting which could cause damage to persons and/or objects. All
maintenance operations, installations, or shifting of the pump with the
electric system live may cause severe or fatal injury. During operation,
avoid moving or shifting the pump. Before using the pump, always check
that the cable and all the electric devices are in working condition. Never
start the pump by inserting the plug in the socket and/or switching on the
switch with bare feet, with your feet in the water, or with wet hands.
The user must not carry out under his own initiative any operations or jobs
not recommended in this manual.
5.2 GENERAL SAFETY WARNINGS
WSP50 AND WSP100 pumps are designed in such a way that all
the moving parts are protected by the use of casings. The
manufacturer declines all responsibility in the event of damage
caused as a result of tampering with these devices.
Each lead or live part is electrically insulated to ground; there is
also a further safety device in that the accessible conductive parts
are connected to a ground lead so that the parts within reach do
not become electrically charged in the event of failure of the
principal insulation.
WARNING: Cancer and Reproductive Harm
www.P65Warnings.ca.gov
background
4
6. GENERAL DESCRIPTION
WSP50 and WSP100 series pumps are all similar from the functional and
constructive point of view; the only differences are the following:
•Power
• Flow rate
•Head
•Weight
• Dimensions
WSP50 and WSP100 series pumps are used for handling water, even at
high temperatures (see “7.1. PUMP TECHNICAL DATA” on page 4).
Thanks to their small bulk and ease of transport, they may be used for
fixed or temporary installations, with or without automatic start.
These pumps guarantee long life and constant performance if used
according to the conditions given in section 8 on page 5 and
section 14 on page 9.
7. TECHNICAL DATA
7.1. PUMP TECHNICAL DATA
Max. fluid temperature 104°F/40°C
Max. dimension suspended solids 2 inches
Max. immersion depth 33 feet
Length of power cable 25 feet
Type of impeller single channel
Type of seal on the shaft double mechanical seal in an oil
chamber
Type of bearing shielded ball bearing
Delivery diameter 2-inch NPTF
Impeller material stainless steel
Pump structure material stainless steel
Motor structure material stainless steel
Seal cover material stainless steel
Intake side cover material stainless steel
Pump body variable features threaded with feet
background
5
7.2. MOTOR TECHNICAL DATA
THE MANUFACTURER RESERVES THE RIGHT TO ALTER THE
TECHNICAL DATA IN ORDER TO MAKE IMPROVEMENTS AND
BRING THEM UP TO DATE.
8. RECOMMENDED AND NON-RECOMMENDED USE
NOTICE
Failure to respect the prescribed limits constitutes a situation of use
that is technically improper and endangers the safety of persons,
RELIEVING THE MANUFACTURER OF ANY RESPONSIBILITY IN
THE EVENT OF ACCIDENTS TO PERSONS OR DAMAGE TO
OBJECTS OR TO THE PUMP, AND ALSO RENDERING THE
WARRANTY INVALID.
8.1 RECOMMENDED CONDITIONS OF USE
WSP50 and WSPI00 series pumps may be used for handling dirty or
semidirty water or water with suspended bodies with a diameter no
greater than 50 mm; for draining garages, cellars, basements, swimming
pools, basins, tanks, fountains, drains, cesspools, sewage collection
drains from cesspools; for draining excavations, flowing irrigation from
ditches, rainwater tanks or streams. The pump may be used for
continuous duty only if totally submerged. Use the pump in keeping with
its technical characteristics listed in section 7 on page 4.
Power (Versions) 1/2 hp and 1 hp
Poles 2
Insulation class F
Degree of protection IP58
Type of duty continuous
Phase-frequency-voltage 60Hz 115 volts single-phase
Overload protection thermal protection single-phase
Motor structure material molded steel
Shaft material stainless steel
Cable material SOW-NSO
background
6
8.2 NON-RECOMMENDED CONDITIONS OF USE
WSP50 and WSP100 series pumps cannot be used for handling water
containing acids and corrosive liquids in general, water with temperatures
higher than 40°C, sea-water, or flammable and generally dangerous
liquids. WSP50 and WSP100 pumps must never be allowed to run
without water.
9. HANDLING AND TRANSPORT
9.1 UNPACKING
Check that there are no breaks or severe dents in the packing; if there
are, point this out immediately to the person who delivers the material.
After removing the pump from the package, check that it has not suffered
any damage during transport; if damage is found, inform the dealer within
8 days of delivery. Then check that the characteristics stated on the plate
of the pump are the same as you requested in your order.
9.2 HANDLING AND DISCONNECTING
NOTICE
Failure to follow these instructions may cause the pump to fail,
suffering severe damage. Do not use the power cable to lift or drag the
pump.
To handle or disconnect the pump you must:
• Remove the plug from the power socket and/or turn off the switch if
provided
• Roll up and hold the electric power cable in your hand
• Lift the pump and the delivery pipe with the handle provided or with a
cable fixed to the handle.
If the pump is set for fixed applications, perform the following operations
before handling it:
• Remove the plug from the power socket and/or turn off the switch, If
provided
• Unscrew any clamps and remove the delivery pipe
• Roll up and hold the electric power cable in your hand
• Lift the pump with the handle provided or with a cable fixed to the
handle.
background
7
9.3 TRANSPORT
The pump is packed in a cardboard box for transport; as its total weight
and bulk are not excessive (fig.1) transport presents no problems
.
10. INSTALLATION
NOTICE
TO LIFT OR LOWER THE PUMP, USE A ROPE FIXED TO THE HANDLE; NEVER
USE THE ELECTRIC POWER CABLE.
10.1. FIXED INSTALLATION
a) The pump must be placed on a level surface.
b)
Lo
wer the pump with a cable fixed to the hand
le.
c) Wh
en positioning the pump, observe the minimum required distance
s
(se
e page 11) from walls, from the sides of the drain or other location
,
so a
s to allow functioning, use, and maintenance operations in safe
conditions.
d)
It is
recommended to use G2 rigid pipes (metal or plastic), to be
screwed onto the threaded delivery union of the pump.
e)
It is
recommended to fit a no-return valve on the delivery pipe.
10.2. TEMPORARY INSTALLATION (FOR TEMPORARY USE)
a) The pump must be placed on a level surface.
b)
When
positioning the pump, observe the minimum required distan
ces
(f
ig.1) from walls, from the sides of the drain or other location, so as to
allow functioning.
c)
It is recommended to use G2 flexible pipes, with couplings of the same
size if required.
d)
It is
recommended to fit a no-return valve on the delivery pipe.
background
8
11. ASSEMBLY AND DISASSEMBLY
The pump has no separate accessories, so no assembly is required for
installation. If the pump has to be disassembled (due to breakage or any
other reason), the user must notify their dealer or the manufacturer.
FAILURE TO COMPLY WITH THIS RULE RENDERS THE
DISTRIBUTOR’S LIMITED WARRANTY INVALID.
12. PREPARATION FOR USE
12.1. ELECTRIC CONNECTION
a) For connection to the power mains, the pump is provided with a 25 foot
cable. When connecting, consider the installed power and the outlet
voltage (see section 1.2 on page 1).
b) The outlet must have an efficient ground system complying with the
electrical standards in force in the user's country; the installer is
responsible for checking this.
c) The WSP50 and WSP100 pumps have a plug with ground contact;
grounding is provided by the plug itself when it is inserted in the socket.
d) We advise fitting a high-sensitivity differential switch in the electric
system (0.03 A).
The electric connection must be by a licensed technician.
12.2. ADJUSTING AND REGISTERING
The only thing that needs checking once installation is complete is the
length of the cable with float with respect to the minimum and maximum
water level (fig.1).
13. USE AND START-UP
Insert the plug and/or turn on the switch; the pump starts operating; once
the pump has taken in water up to the minimum level (see page 11)
regulated by the float, it will cut out automatically.
background
9
14. MAINTENANCE AND REPAIRS
14.1 MAINTENANCE
NOTICE
Before performing any maintenance operations, disconnect the plug
and/or switch off.
THE PUMP MUST BE DISMANTLED ONLY BY THE DEALERSHIP
TECHNICIANS. FAILURE TO
OBSERVE THIS RULE RENDERS THE
DISTRIBUTOR’S LIMITED WARRANTY INVALID. THE SAME
APPLIES TO
REPAIR JOBS AND/OR REPLACEMENTS.
NOTICE
To ensure correct functioning and long life of the pump, the intake
mouth must not be blocked and the impeller must be kept clean.
If the intake mouth is blocked it must be cleaned; always wear gloves to
protect your hands.
If the impeller is dirty, refer to “15.2 PUMP IMPELLER COVER
DISASSEMBLY” on page 12 and proceed as follows:
1. Wear protective gloves to avoid cutting your hands
2. Unscrew the six socket head screws
(not the nut, because it is
welded to the pump body).
3. Slip off the pump body.
4. Remove the O-ring.
5. The impeller is now uncovered. Check that it is clean. Check also that
the space between the impeller and the protective casing is clean.
To reassemble, perform the operations listed above in reverse order.
background
10
14.2 TROUBLESHOOTING
TYPE OF FAULT
The pump does not work (the motor does not turn over)
TYPE OF FAULT
The pump works at a low flow rate
TYPE OF FAULT
The pump stops after brief periods of operation (tripping the thermal protection)
CAUSE REMEDY
No electric power Check the contactor on the electric line
Plug not inserted Check power connection to the line
Float blocked Check that the float reaches ON level
Impeller blocked Check cause of blockage
Thermal protection has
tripped
This resets automatically
Faulty motor or capacitor Contact the nearest distributor
Hole in the intake cover is
blocked
Clean the hole; be certain to disconnect
power
No-return valve blocked Clean the valve and check its operation
CAUSE REMEDY
Dirty impeller or delivery
pipes
Clean them; be certain to disconnect
power
No-return valve blocked Clean the valve and check its operation
Water level too low Switch off the pump
Wrong voltage Supply the pump with the correct voltage
indicated on the data plate
CAUSE REMEDY
Impeller blocked by
foreign bodies
Remove the foreign bodies; be certain to
disconnect power
Liquid temperature too
high
The temperature exceeds the technical
limits of the pump
Internal defect Contact the nearest Honda pump dealer
background
11
15. ILLUSTRATIONS
15.1 INSTALLATION WITH MINIMUM FUNCTIONAL SPACES
background
12
15.2 PUMP IMPELLER COVER DISASSEMBLY
SOCKET HEAD
SCREW (6)
O-RING
PUMP BODY
background
13
15.3 WIRING DIAGRAM
Black Bl Green G
Brown Br White W
Gray Gr Yellow/Green Y/G
Bl
W
MOTOR
C
A
P
A
C
I
T
O
R
Amp
Prot
Therm
Prot
BlBlBlBl
Y/G
G
G
Bl
G
W
C
A
P
A
C
I
T
O
R
W
W
W
Bl
Bu
G
W
background
14
16. WARRANTY SERVICE INFORMATION
Honda Power Equipment dealership personnel are trained professionals.
They should be able to answer any question you may have. If you
encounter a problem that your dealer does not solve to your satisfaction,
please discuss it with the dealership's management. The Service
Manager or General Manager can help. Almost all problems are solved in
this way.
If you are dissatisfied with the decision made by the dealership's
management, contact the Honda Power Equipment Customer Relations
Office. You can write:
When you write or call, please give us this information:
• Model and serial number
• Name of the dealer who sold the pump to you
• Name and address of the dealer who services your pump
• Date of purchase
• Your name, address, and telephone number
• A detailed description of the problem
American Honda Motor Co., Inc.
Power Equipment Division
Customer Relations Office
4900 Marconi Drive
Alpharetta, GA 30005-8847
Telephone: (770) 497-6400 M-F, 8:30 a.m. - 7:00 p.m. ET
background
15
17. DISTRIBUTOR’S LIMITED WARRANTY
Honda Power Equipment
This warranty is limited to the following Honda Power Equipment products when distributed by
American Honda Motor Co., Inc., Power Equipment Division, 4900 Marconi Drive, Alpharetta,
Georgia 30005-8847, purchased at retail or placed in rental service on or after January 1, 2010.
(1) P
rivate residential: Used in maintaining owner’s primary and/or secondary residence. Any othe
r
us
e, including but not limited to informal “for hire” use, is considered commercial/rental/institutional
use.
To Qualify for This Warranty:
The product must be purchased in the United States, Puerto Rico, or the U.S. Virgin Islands from
American Honda or a dealer authorized by American Honda to sell those products. This warranty
applies to first retail purchaser and each subsequent owner during the applicable warranty time
period, unless noted otherwise.
What American Honda Will Repair or Replace Under Warranty:
American Honda will repair or replace, at its option, any part that is proven to be defective in
material or workmanship under normal use during the applicable warranty time period. Warranty
repairs and replacements will be made without charge for parts or labor. Anything replaced under
warranty becomes the property of American Honda Motor Co., Inc. All parts replaced under
warranty will be considered as part of the original product, and any warranty on those parts will
expire coincident with the original product warranty.
To Obtain Warranty Service:
You must, at your expense, take the Honda Power Equipment product, accessory, replacement part,
apparel, or the power equipment on which the accessory or replacement part is installed, and proof
of purchase to any Honda Power Equipment dealer in the United States, Puerto Rico, or the U.S.
Virgin Islands who is authorized to sell and/or service that product, during the dealer’s normal
business hours. To locate a dealer near you, visit our web site at PowerEquipment.Honda.com and
click on Find a Dealer.
If you are unable to obtain warranty service or are dissatisfied with the warranty service you receive,
contact the owner of the dealership involved; normally this will resolve the problem. However, if you
should require further assistance, write or call the Power Equipment Customer Relations
Department of American Honda Motor Co., Inc. See “16. WARRANTY SERVICE INFORMATION”
on page 14.
PRODUCTS COVERED BY
THIS WARRANTY
LENGTH OF WARRANTY
(from date of original retail purchase)
PRIVATE
RESIDENTIAL
(1)
COMMERCIAL/
RENTAL/
INSTITUTIONAL
Electric submersible pumps 12 months 12 months
background
16
Exclusions:
1. Any damage or deterioration resulting from the following:
- Neglect of the periodic maintenance as specified in the product owner’s manual
- Im
proper repair or maintenance
- Op
erating methods other than those indicated in the product owner’s manual
- In
creasing engine speed beyond factory specification
- Th
e use of non-genuine Honda parts, accessories, lubricants, and fluids other than thos
e
ap
proved by Honda
- Ex
posure of the product to soot and smoke, chemical agents, bird droppings, sea water, salt
or other corrosive environments
- Col
lision, fuel contamination or deterioration, neglect, unauthorized alteration, misuse,
incorporation or use of unsuitable attachments or parts
- No
rmal wear and tear (including, but not limited to, normal fading of painted or plated
surfaces, sheet peeling, and other natural deterioration)
2. Consumable parts: Honda does not warrant parts deterioration due to normal wear and tear.
The
following parts are not covered by warranty (unless they are needed as a part of anothe
r
warra
nted repair): spark plug, fuel filter, air cleaner element, clutch disc, tire, wheel bearing,
recoil starter rope, cable, belt, cutter blade, oil, and grease.
3. Cleaning, adjustment, and normal periodic maintenance work (carburetor cleaning, engine o
il
dra
ining, blade sharpening, belt and cable adjustments).
4. Any product that has ever been declared a total loss or sold for salvage by a financia
l
in
stitution or insurer.
5. Auger and paddle assemblies of snow throwers, tiller tines of roto-tillers, mower blades and
mower deck housings, are specifically not warranted against impact damage, including but not
limited to, abrasive damage.
Disclaimer of Consequential Damage and Limitation of Implied Warranties:
American Honda disclaims any responsibility for loss of time or use of the product, transportation,
commercial loss, or any other incidental or consequential damage. Any implied warranties are
limited to the duration of this written limited warranty. Some states do not allow limitations on how
long an implied warranty lasts and/or do not allow the exclusion or limitation of incidental or
consequential damages, so the above exclusions and limitations may not apply to you. This
warranty gives you specific legal rights, and you may also have other rights which vary from state to
state.
Honda Parts, Accessories, and Apparel
This warranty is limited to Honda Power Equipment parts, accessories, and apparel when
distributed by American Honda Motor Co., Inc., 4900 Marconi Drive, Alpharetta, Georgia
30005-8847.
To Qualify for This Warranty:
1. The parts, accessories, or apparel must be purchased from American Honda or a dealer
au
thorized by American Honda to sell those products in the United States, Puerto Rico, an
d
the
U.S. Virgin Islands. Parts and Accessories must be purchased for installation on origin
al
Ho
nda equipment or engines to be eligible for warranty coverage. Installing parts and
accessories on non-Honda products or engines voids this warranty.
2. You must be the first retail purchaser. This warranty is not transferable to subsequent owners.
PRODUCTS COVERED
BY THIS WARRANTY
LENGTH OF WARRANTY
(from date of original retail purchase)
PRIVATE
RESIDENTIAL
COMMERCIAL/
RENTAL/
INSTITUTIONAL
Parts 6 months 3 months
Batteries 6 months 3 months
Accessories 12 months 3 months
Apparel 6 months 3 months
background
17
What American Honda Will Repair or Replace Under Warranty:
American Honda will repair or replace, at its option, any Honda Power Equipment parts,
accessories, replacement parts, or apparel that are proven to be defective in material or
workmanship under normal use during the applicable warranty time period. Anything replaced under
warranty becomes the property of American Honda Motor Co., Inc. The warranty on all parts,
accessories, and apparel replaced under warranty will expire coincident with the original warranty
on the replaced parts, accessories, or apparel.
Parts and accessories installed by a dealer who is authorized by American Honda to sell them will
be repaired or replaced under warranty without charge for parts or labor. If installed by anyone else,
parts and accessories will be repaired or replaced under warranty without charge for parts, but any
labor charges will be the responsibility of the purchaser.
Apparel will be repaired or replaced under warranty without any charge.
To Obtain Warranty Service:
You must, at your expense, take the Honda Power Equipment part, accessory, apparel or the Honda
Power Equipment on which the part or accessory is installed, and proof of purchase to any Honda
Power Equipment dealer in the United States, Puerto Rico, or the U.S. Virgin Islands who is
authorized to sell that product, during the dealer's normal business hours. To locate a dealer near
you, visit our web site at PowerEquipment.Honda.com and click on Find a Dealer.
If you are unable to obtain warranty service or are dissatisfied with the warranty service you receive,
contact the owner of the dealership involved; normally this will resolve the problem. However, if you
should require further assistance, write or call the Power Equipment Customer Relations
Department of American Honda Motor Co., Inc. See “16. WARRANTY SERVICE INFORMATION”
on page 14
.
Exclusions:
This warranty does not extend to parts, accessories, or apparel affected or damaged by collision,
normal wear, use in an application for which the product was not designed or any other misuse,
neglect, incorporation or use of unsuitable attachments or parts, unauthorized alteration, improper
installation, or any causes other than defects in material or workmanship of the product. Installing
parts and accessories on non-Honda products or engines voids this warranty.
Disclaimer of Consequential Damage and Limitation of Implied Warranties:
American Honda disclaims any responsibility for loss of time or use of the product, or the power
equipment on which the product is installed, transportation, commercial loss, or any other incidental
or consequential damage. Any implied warranties are limited to the duration of this written warranty.
Some states do not allow limitations on how long an implied warranty lasts and/or do not allow the
exclusion or limitation of incidental or consequential damages, so the above exclusions and
limitations may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which vary from
state to state.
PWL50623-X
background
18
NOTES
background
19
NOTES
background
background
background
Printed in U.S.A
POM31WSP817
MID.500.2022.05
© 2018 American Honda Motor Co., Inc.—All Rights Reserved
SUBMERSIBLE PUMP
Owner’s Manual
WSP50AA • WSP100AA
BY:
Printed on
Recycled Paper
WSP50AA
WSP100AA

Specifications

Honda WSP50 Questions and Answers

Questions and Answers

Related Products