INSTRUCTION MANUAL
OUTDOOR ROUND METAL
PROPANE FIRETABLE
MODEL NUMBER: COB10009
ITEM NUMBER: CTM99103G
08/2024
DO NOT RETURN THIS ITEM TO THE STORE
IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY
Should you encounter problems aer following all the steps herein contained please contact our Customer Support:
Call 1-888-227-3340 or email: [email protected]. Kindly provide the model number, place and date of purchase and a short description of the problem.
LIMITED WARRANTY is product has a 1 year Limited Warranty. is warranty is limited to the replacement of defective parts only. Labor charges and/or damage
incurred during installation, repair, replacement as well as incidental and consequential damages connected with the above are excluded. Any damage to this product as a
result of neglect, misuse, accident, improper installation or use other than the purpose SHALL VOID THIS WARRANTY
Please read and understand this entire manual before attempting to assemble, operate or install the product. Failure to follow the dangers, warnings
and cautions contained in this owners manual may result in a re or explosion causing damage to property, serious bodily injury or death
ank you for purchasing your new
OUTDOOR ROUND
PROPANE FIRETABLE

22
For Outdoor Use Only
(outside any enclosure)
WARNING
FOR YOUR SAFETY
WARNING
FOR YOUR SAFETY
1) Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage.
2) Read the installation, operation, and maintenance
instructions thoroughly before installing or servicing this
equipment.
3) Failure to follow these instructions could result in re or
explosion, which could cause property damage, personal
injury or death.
Installer: Leave these instructions with the consumer.
Consumer: Keep these instructions for future
reference.
WARNING
FOR YOUR SAFETY
1. is repit is for outdoor use only.
2. DO NOT use this repit in a building, garage, boats
recreational vehicles, or any other enclosed area.
3. is repit is not to be operated by children.
4. Always use in accordance with all applicable local, state and
national codes. Contact your local re department for details on
repits.
5. When using this repit, exercise the same precautions you
would do with any open re.
6. e use of alcohol, prescription or non-prescription drugs may
impair the consumer’s ability to properly assemble or safely
operate this repit.
7. DO NOT use it without reading the entire “Owner’s Manual”
rst.
8. DO NOT use this repit until it is completely assembled.
9. DO NOT alter this repit in any manner.
10. DO NOT use gasoline or other ammable vapors or liquids in
the vicinity of this or any other repit.
11. DO NOT use this repit near automobiles, trucks, vans,
recreational vehicles, electrical cords or any other combustible
objects.
12. Always use this repit on a hard, level, non-combustible surface.
13. e repit must be inspected before each use.
14. e safeguard spark screen must be used while burning.
15. DO NOT use in windy conditions.
16. DO NOT wear ammable or loose clothing when this repit.
17. DO NOT touch any part of the repit until it is completely
cooled down. Never leave a lit repit unattended.
18. Children should be carefully supervised where they are
anywhere near the repit.
19. DO NOT attempt to move or store this repit until the repit
is completely cooled down.
20. Burning must be inside the metal bowl.
21. DO NOT put any hot part of the repit onto combustible
surfaces such as grass, wooden deck or furniture.
22. USE PROPANE GAS ONLY!
23. DO NOT store or use gasoline or other
ammable vapors in the vicinity of this or any other repit.
-Service must be performed by a qualied installer.
24. For use with cylinders marked PROPANE only. Do not connect
to a remote gas supply.
25. If the repit is stored indoors, detach and leave propane
cylinder outdoors.
26. If you smell gas:
1. Shut o gas to the repit.
2. Extinguish any open ame.
3. If odor continues, keep away from the repit and immediately
call your gas supplier or re department.
27. is re table must be attended at all times!
28. A liquid propane cylinder not connected for use shall not be
stored in the vicinity of this or any other repit.
29. e propane cylinder must be disconnected when this re table
is not use.
30. Do not exceed 1/4” depth of re glass or lava rocks directly
over the burner holes, this may result in unburned propane gas
pooling in the repit.
31. CARBON MONOXIDE HAZARD
is repit can produce carbon monoxide which has no odor.
Using it in an enclosed space can kill you.
Never use this repit in an enclosed space such as a camper,
tent, car or home.
ALL ABOVE MUST BE EXACTLY FOLLOWED.

33
DANGER
is repit is intended for outdoor use only. It shall not be installed inside a building, garage or any other enclosed area. It shall not be installed on boats
or recreational vehicles. A boiler shall not be used on or under any apartment, or condominium balcony or deck.
is repit produces heat. Respect minimum clearances to all sides of the burner of at least 10 feet (3 m) from any structure or combustible material, and
do not use it under an overhead unprotected combustible construction.
Use the burner on a stable leveled non-combustible surface and In an area clear of combustible materials. Asphalt surface may not be acceptable for this
purpose.
CAUTION
e installation of this product must conform with local codes or, in the absence oocal codes, with either the National Fuel Gas
FOR OUTDOOR USE ONLY! is repit shall be used only outdoors in a well-ventilated space and shall not be used in a building, garage, or any
other enclosed area.
USE PROPANE GAS ONLY!
Use only with a propane gas tank (sold separately). Do not attach to a remote gas supply. Propane gas is not natural gas. Only use propane gas for this
re pit. Never use charcoal or any other solid fuel in the re pit. During ignition procedure, never get your face close to the burner as an unnoticed ame
may light up and cause injury.
LIQUID PROPANE GAS WARNING: Do not exceed 1/4 in. depth of lava rocks directly above burner holes. Applying too much media may result
in unburned gas pooling in re pit. Ventilation is required to allow fresh air into enclosure and for any residual gas to escape.
• Do not operate the re pit if there is a gas leak present.
• Never use a ame to check for gas leaks.
• e max. inlet supply pressure: max. gas supply 11 inch w.c. (2.74kPa).
• e gas pressure regulator provided with the re pit must be used.
• Use liquid propane gas tanks only with these required measurements: 4 in. (diameter) x 8 in. (tall) with 1 lb. capacity maximum.
• Propane tank used must include a collar to protect the propane gas tank valve.
• Never ll the propane gas tank beyond 80% full.
• Propane gas tank supply system must be arranged for vapor withdrawal.
• Do not use a propane gas tank with a damaged valve and any other worn out parts. A dented or rusty propane gas tank may be
• hazardous and should be checked by your gas supplier prior to use.
• Do not burn any other materials than are supplied with and intended for use in this re pit.
• Lava rocks could hit somebody’s face or eyes during initial start of this unit, so please keep away from the re pit for the rst 20 minutes aer it has
been ignited.
• Do not operate re pit unless it is completely assembled and all parts are in place.
• Pay attention when operating the re pit. It is hot when in use and should never be le unattended. Do not move it while in operation.
• Do not use this re pit for cooking.
• Do not put any other replace cover or anything ammable on, beneath or around the re pit.
• Users should be alerted to the hazards of high surface temperatures and keep a safe distance to avoid burning or clothing ignition.
• Do not sit on the re pit. Do not rest feet or hands on the re pit.
• Never lean over the open re pit or place hands or ngers on the upper portion of an operational unit.
• Keep any electrical supply cords and the fuel supply hose away from any heated surfaces.
• Combustible materials should never be within 72 inches of the top, 48 inches of the back or sides of the re pit.
• is re pit must be attended at all times!
• Should the re go out while burning, turn the gas valve o. Follow the instructions and wait ve minutes before attempting to relight.
• Do not use this re pit if any part has been under water.
• Do not pour water into re pit.
• Immediately call a qualied service technician to inspect the appliance and to replace any part of the control system and any gas control which has
been under water.
• Do not light or use gas unit if lava rocks are wet. Ensure lava rocks are completely dry before igniting as intense heat could cause the rocks to crack
or pop.
• Do not attempt to disconnect the gas regulator or any gas ttings while your re pit is in operation.
• Do not handle re pit until it is shut o and completely cooled.
• e propane gas tank must be disconnected when re pit is not in use.
• Do not store a spare or disconnected propane gas tank under or near this re pit, or in the vicinity of any other appliance.
• If the re pit is stored indoors, detach and leave propane gas tank outdoors.
• Maximum propane gas pressure is 100psi.
• e LP gas supply tank must be constructed and marked in accordance with the specications for LP gas tanks of the U.S. Department of
Transportation (DOT) or the National Standard of Canada CAN/CSA-B339, LP gas tanks, spheres and tubes for the Transportation of Dangerous
Goods and Commission.
• e LP gas tank must have a listed overlling prevention device (OPD) and a QCCI or Type I, (CGA810) LP gas tank connection.

44
Preparation and Operation
BEFORE USING THE OUTDOOR BURNER:
1. Install or operate the unit in an open area.
2. Make sure the propane cylinder / tank valve is on “OFF” position”(clockwise).
3. Make sure propane gas control on regulator is in “OFF” position (counterclockwise).
4. Inspect orice at end of hose and regulator. Remove all debris.
• Before each use inspect hose for damage, wear, cuts or leaks. If any damage is identied, the hose must be replaced before the repit is used.
Do not attempt to repair yourself. e replacement hose assembly shall be specied by the manufacturer. Keep fuel supply hose away from any
heated surface.
LEAK TESTING:
IMPORTANT: DO NOT SMOKE WHILE LEAK TESTING NEVER LEAK TEST WITH AN OPEN FLAME !!
Before each use, follow the procedures below to check the entire system for leaks. If the smell of gas is detected at anytime, turn o propane gas supply
and immediately check the entire system for leaks.
TO CREATE A SOAPY SOLUTION FOR LEAK TEST: Mix 3 tablespoons of liquid dish detergent with water until the container is full. en, use a
spray bottle (make sure to shake it well to create more bubbles) or an applicator brush to apply the solution to all ttings, connections, and gas hoses.
Before conducting the initial leak test, ensure that the propane cylinder / tank is full.
LEAK TESTING PROCEDURE:
1. Before performing a leak test, be sure that no sparks can occur and you are in a spacious outdoor area.
2. Connect the propane gas tank to the regulator and turn the valve on the unit to the “o” position.
3. Brush a soap and water mixture on all connections. Turn the gas supply on; if bubbles occur on any connection there may be a leak. If you smell
gas or a leak is discovered turn the gas valve o, disconnect propane gas tank and do not use the appliance until the leak is repaired.
4. Do not use the heating unit without inspecting the gas hose. If there are signs of wear or abrasion you must replace the hose (if applicable).
Pumice stones/lava rocks/LavaGlass could pop up and strike somebody’s face during the process of lighting this unit; stand away from the unit
for the rst 20 minutes aer igniting. Flame height should be a yellow/blue color between 2 - 10 inches in height.
5. Wait 50 minutes aer extinguishing ame prior to placing a lid (if applicable) or protective cover on heating item.
To Extinguish the Firepit:
1. Turn control knob clockwise to the “HIGH” position; push and continue turning the control knob to the “OFF” position.
2. Close the cylinder valve on the propane gas tank if you don’t intend to use it for a long time.
Maintenance:
1. Keep your repit free and from combustible materials.
2. Visually inspect the repit burner from obstructions and keep repit free and clear from debris .
3. Aer the repit burner and lava rocks are completely cooled down, use a so brush to get rid of the mild stains, loose dirt and soil.
4. Wipe with a so cloth.
5. Stubborn stains, discoloration and rust pitting can occur from exposure to harsh outdoor conditions.
6. Be careful not to let any powder or solvent come in contact with painted or plastic components as damage may occur.
7. Store the repit in a cool dry place away from sunlight.
8. e propane gas tank must be disconnected and removed from the repit before the it can be stored.
9. If your repit is equipped with a battery, make sure both the propane gas and the repit are turned o before changing battery.

55
Parts List
Propane Tank & Fire Glass Installation
Connect the pressure-regulating valve to the propane tank
(Figure E)
1 - Turn the cylinder valve clockwise to the gas supply on the
propane tank.
2 - Screw regulator coupling clockwise (by hand only) Make
sure it is fastened.
Lava Rock Installation
Keep screen clear. Do not place Lava Rock on the screen (see
gure below).
To prevent the ame from being extinguished, the repit
burner must be completely covered by the Lava Rock (see
gure below).
Correct Incorrect
H
I
L
O
O
F
F

6
Assembly Instructions
OFF
LO
IH
OFF
LO
IH
OFF
LO
IH
OFF
LO
IH
1
Place the top upside down in the carton so it will
not be damaged.
2
Mount the protective canister sleeve to the top using 3
screws.
3
Mount the back panel rst. Opposite the control knob which
is accessed through the door. Don't tighten the screws, just a
little snug.
4
Mount the 2 side panels, again don't tighten until the door
section is moounted. Install the batteries as shown in enlarged
image.
(see page 8 for "Battery Installation and Operation)

OFF
LO
IH
Assembly Instructions (continued)
OFF
LO
IH
HI
LO
OFF
off
Lo
HI
7
Put the protective cover in place until ready to use.
8
Finished product.
5
Aer the back and sides have been assembled but not
tightened, mount the door section then go back and tighten
the screws.
6
Flip the unit right side up and if desired put the decorative
stone around the burner. Be sure not to cover the starter.
7

Operation Instructions
Battery Installation
- Remove battery compartment cover and install 3 C batteries (not included).
- Ensure the batteries aree installed with the proper polarity direction. (see Figure A)
- Replace battery compartment cover/
- Press the switch to the “ON” position.(see Figure B)
Lighting and Gas Control Setting
- Before lighting, make sure the valve knob is in the “OFF” position/
- Always perfor a leak test before lighting the burner.
- From the “OFF” position, push in and turn the control knob anti-clockwise to the “HIGH” position/
- Hold a lit match within 1/4” to the lava rocks as shown on the diagram below, until the burner is lit. (see Figure C)
- If it fails to light, turn to “OFF”, wait 5 minutes before attempting to re-light.
- Once the burner is lit, turn the control knob to the desired heat setting, “LOW” to “HIGH”. (see Figure D)
Shutting Down the Gas
- Turn the control knob gently to the “OFF” position.
- Disconnect and remove the gas tank when the gas replace is not in use.
HI
LO
OFF
Figure B
Figure D
Figure A
Figure C
8