Avantco Ice Machines CGF-900 Avantco Ice Countertop Mount Glass Froster / Chiller

Product's Documents

Below are documents related to this product, you can read online or download:
User Manual Other Documents
  • Avantco Ice Machines GLASS FROSTER Specsheet - (English) Download
CGF-900 photo

194cgf900 Manual

This is the main product document for model CGF-900. Additionally, the document applies to other Avantco Ice Machines models: 194CGF900

The file format is pdf, 3 pages, you can download this manual here .

background
User Manual
www.AvantcoIce.com
01/2025
Countertop Mount
Glass Froster / Chiller
Models:
#194CGF900
#194CGF900K
Note:
Read the manual thoroughly prior to equipment setup, operation, and maintenance.
An adapter is included in the product packaging. This adapter is only needed for applications
in places other than North America.
background
2
User Manual
www.AvantcoIce.com
Countertop Mount Glass Froster / Chiller
Table of Contents
Warnings .............................................................................................................................. 2
Installation ........................................................................................................................... 2
Replacing Batteries ........................................................................................................... 3
Connecting CO
2
Cylinder ................................................................................................ 3
Troubleshooting ................................................................................................................. 3
Warnings
This product works with liquid CO
2
only, do not use other compressed gas cylinders with high-pressure
or non-liquid CO
2
. A liquid CO
2
cylinder with siphon tube is required for eective delivery of liquid CO
2
.
A non-liquid CO
2
cylinder may be used if the tank is inverted (turned upside down). Install this product in
a well-ventilated area to assist in venting excess CO
2
.
Installation
1. Select bracket for installation, unscrew clamp, and fit clamp over work surface. Tighten down.
NOTE: The extra bracket in the box is specific for use in underbar refrigeration where there is minimal
area below the countertop for standard bracket. You can replace the bracket by unscrewing the bolts
inside the clamp that attach it to the froster unit.
2. To operate the LED lights, see the “REPLACING BATTERIES” section.
3. Place steel wire for connection hose around the CO
2
tank.
4. Add rubber seal rings to inside of connection hose nut, then connect to CO
2
tank.
*See the connecting CO
2
cylinder section for connection instructions.
5. First, tighten by hand. Then, use a wrench to tighten.
NOTE: Do not overtighten.
6. Slowly open CO
2
tank to ensure there are no leaks in the system. Then, fully open CO
2
tank.
7. Press down on the glass froster head to ensure equipment is operational.
background
3
User Manual
www.AvantcoIce.com
Countertop Mount Glass Froster / Chiller
REPLACING BATTERIES
NOTE: 2 AA batteries are required to use the LED lights. The unit does not require
the batteries or use of LED lights.
1. Remove top access cover on the glass froster.
2. Locate the battery harness, and if applicable, remove and dispose of old batteries.
3. Replace with compatible AA batteries in the battery harness.
4. Return the battery harness to original position.
5. Return top access cover to glass froster.
6. Press down on glass froster head to ensure LED functionality.
CONNECTING CO
2
CYLINDER
NOTE: When frosting time exceeds 10 seconds, this is an indication that it is time
to change the cylinder.
NOTE: We recommend using a 20 lb. or larger CO
2
tank with this machine for
optimal results.
1. Close the shut-o valve of the CO
2
cylinder.
2. Press the head of the glass froster until all excess pressure is released.
3. Loosen the nut on the CO
2
cylinder and remove the CO
2
cylinder.
4. Replace with full CO
2
cylinder.
5. Place steel wire for connection hose around the CO
2
tank.
6. Add rubber seal rings to inside of connection hose nut, then connect to CO
2
tank.
7. First, tighten by hand. Then, use a wrench to tighten.
NOTE: Do not overtighten.
8. Slowly open CO
2
tank to ensure there are no leaks in the system. Then, fully open
CO
2
tank.
9. Press down on the glass froster head to ensure equipment is operational.
Troubleshooting
Problem Possible Solution
Long frosting time. Replace the CO
2
tank with a full tank.
Not frosting at all. Replace the CO
2
tank with a full tank.
Light is not working. Replace worn batteries with new AA batteries.

Specifications

Avantco Ice Machines CGF-900 Questions and Answers