Cool Mist
Ultrasonic Humidifier
LCDJSQ-J39
User Manual

Precautions
Thank you for purchasing our humidifier LCDJSQ-J39.
Please read this manual carefully before using
and keep it for future reference.
All pictures shown are for illustration purposes only.
Actual products may vary due to product enhancement.
For more installation information,
please visit the official website link or scan the QR code:
https://lacidoll.com/pages/user-manual

Safety Guide
Placement
Components
Installation
Water Filling
Control Panel & Remote
Care & Maintenance
Troubleshooting
Product Specifications
Warranty
1-2
3
4
5-7
8
9-11
12-14
15-16
17
18
Contents

0101
Safety Guide
0101
Only use the humidifier as described in this manual.
Do not connect the machine to a socket that exceeds the
rated voltage or use an extension cable, as this may cause
fire or electric shock.
When not in use, turn the humidifier off and disconnect
from power by removing the plug from the outlet.
Always unplug your humidifier from the power outlet
before cleaning your humidifier.
Do not immerse the humidifier sink, power cord, or plug in
water.
Do not handle the power cord or plug with wet hands.
Keep the humidifier out of reach from children and pet. When
discarding the product, keep it out of the reach of children
and pet.
Also, take similar precautions for any parts that may
pose a danger, especially those that could be hazardous to
children and pet.

02
Safety Guide
02
Only use the humidifier as described in this manual.
Keep a safe distance when the humidifier is spraying mist,
especially if you have a sensitive respiratory tract.
When the machine is not in use for more than 24 hours,
please pour out the water from the water tank and main body
to prevent mold or impurities from harming your health.
Please do not block the outlet or add water from the mist
outlet otherwise it may cause water leakage, machine
deformationor failure.
Only fill the water tank with clean water. Never fill the water
tank with any other liquids.
Please do not use acidic detergent in the main body. If there
is residual detergent, it may produce toxic gas.
Do not modify the product, and non-professional repair
personnel are prohibited from disassembling or repairing it,
as it may result in fire, electric shock, or injury accidents.
If the product malfunctions, please stop using it
immediately and disconnect the power. Contact the
after-sales team by email.

Placement
03
In direct sunlight.
On an unstable platform.
In high temperatures, humidity, or dust.
Place the humidifier on a level, dry surface that is free from any inclinations. Ensure
that it is horizontally positioned at a distance of more than 50 cm from any
furniture,walls, appliances, or other items.
Please follow these guidelines carefully to ensure the safe and proper operation of your
humidifier. lf you have any questions or concerns, please refer to the user
manual or contact customer support.
Avoid using the humidifier in the following situations to prevent water leakage,signal
jamming, damage, or injury:
Near heat sources like air conditioners,
heaters, stoves, or any other objects that
emit heat.
Under tables, curtains, carpets,
bedding, or any other similar objects to
avoid dampness.
Near objects that emit radio waves
such as radios.
Near precision instruments like
mobile phones, computers, and other
electronic devices.

Components
04
Cover
(Water Inlet)
Main Body
Water Tank
Support Feet
Display
Operation Keys
Casters
Rotatable Nozzle
Cover (Water Inlet)
Air Inlet
Power Input
Max Water
Viewport
Main Body Inside Remote Control

Installation
05
Take off the main body, then take out the screws, rmote control and other
accessories in the water tank. (Reove the insulating plastic sheet.)
Please refer to the Youtube link for assembly details.
https://bit.ly/3yFJGM2
①

Installation
06
Screw the casters and support
feet at the base of the water
tank. (Press the orientation key
to lock the casters.)
Remove the protective bag of
the pump. Place the suction
pump vertically into the water
tank and balance the corre-
sponding interface there.
②
③

07
Installation
Max Water Viewport
Install the mist tube and then insert it into the mist outlet.
Water inlet
Fill the water from the cover (water inlet). Do not beyond
three max water viewport. Connect the plug and turn on the
humidifier.
⑤
④

Water Filling
08
Only water below 40 degrees can be added.
We recommend using purified or distilled water to fill the tank. Usiing tap water
may result in a white dust (dried minerals) on surfaces.
Do not add water through the mist tube, or water may enter the inside and
cause the machine to malfunction.
When the water is insufficient, the humidifier will prompt watter shortage and
automatically shut down. Please refill with water and turn it on.
Note
Add water from the top.
Remove the main body and add water to the water tank directly.

Control Panel& Remote
09
The control panel and remote allow you to operate the humidifier with ease.
Target humidity Indicator
Interval Mist Indicator
No Water Indicatior
Percentage Indicator
Relative Humidity(RH)
Mist Level
Time Value
Hour Indicator
Humidity Value
Target humidity Indicator
remote control
Interval Mist

Control Panel& Remote(cont.)
10
POWER
Press to turn the humidifier on/off.
The humidifier will start misting at the max level.
If there is no water in the tank, icon will flash 5 times, and
the humidifier will turn off automatically.
HUMIDITY
SLEEP
Long press the "Humidity" function on the display to enter
the sleep mode, and the display will be dimmed. Touch
any button to exit sleep mode, and the display will light up.
(Sleep mode can also be controlled directly by remote.)
Press repeatedly to cycle through mist settings: 40%-90%.
A comfortable humidity level is between 40% and 60%.
After setting, the panel will cycle display the current ambient
humidity and the target humidity. When the room reaches
your preferred humidity, the humidifier will automatically stop
misting.
To stop or reset this function, press repeatedly until the
indicator displays .
The function is set to be off by default when turning on the
humidifier.

Control Panel& Remote(cont.)
11
TIMER
During the operation of the machine, lightly touch this button
to set the misting time range from 1 to 12 hours. The display
will show the corresponding values after 3 seconds.
To stop or reset this function, press repeatedly until the icon
disappears.
The function is set to be off by default when turning on the
humidifier.
Interval Mist
MAX-MIN
Press repeatedly to cycle through Interval Mist settings:
P1-P2-P3.
The icon on the display will light up accordingly.
It has 3 patterns:
P1: Spray 30s then stop 30s.
P2: Spray 60s then stop 60s.
P3: Spray 90s then stop 90s.
The function is set to be off by default when turning on the
humidifier.
The humidifier will start misting at the maximum level.
Press repeatedly to cycle through mist settings: 1-2-3-Turbo.
If there is water around the humidifier during use, it means that
the humidity in the room is too high, please adjust the mist setting
appropriately.

12

13

14

Troubleshooting
Q:Why doesn't the display light up after turning on the power?
A:It's possible that water has entered the circuit board. Air-dry the main body for
24hrs. If it still can't be turned on, please contact customer service via email.
Q:Why is the mist output low?
A:When the ambient humidity exceeds the set value, the machine will
automatically stop spraying mist. However, if the atomizer is damaged, please
contact customer service via email.
Q: Why is the red light flashing?
A: It indicates that there is no water in the tank. Ensure the water tank is filled with
clean, distilled water. If there is water in the tank, check if the water pump has fallen
off or is malfunctioning. Please reinstall it or contact customer service for a replace-
ment. If the pump is working normally, check if the float is dirty and unable to move
freely. Clean the float with a cotton swab.
Q: Why is there unusual noise?
A: There could be too little water or the humidifier may be placed on an unstable surface.
Place the humidifier on a solid and sturdy surface and fill the water tank with water.
Q: Why is there white powder around the humidifier?
A: Tap water contains minerals that can adhere to objects.
We recommend using purified or distilled water to fill the humidifier. Avoid using water
with high mineral content, such as tap water. Clean the water tank regularly and keep
precision instruments away from the humidifier to avoid damage.
15

16
Troubleshooting
*If your problem is not listed, please contact Customer Support.
Q: Why is there scale in the water sink or tank?
A: Tap water contains minerals that can adhere to objects. Clean the water sink and
tank regularly
Q: Why does display show an incorrect humidity percentage?
A: Moisture may have built up the humidity sensor. Please dry the sensor with a cloth
or air dry it first.
The humidity sensor will give an improper reading if it is exposed to dust. Avoid
using the humidifier in dusty rooms. Avoid using tap water in the humidifier as this
can increase dust in the air.
Please note that the humidity sensor and hygrometer in the room may have an
error range of 5-10% depending on the sensing method and structure.
If neither of these is the issue, please contact cusstomer service to get
replacement pump via email.
Q: Why is the floor wet or there is water around the humidifier?
A: The humidity may be too high or the humidifier may be placed in a non-ventilated
area, causing the mist to not fully evaporate.
Q: Why is there interference with the TV remote control signal?
A: Keep the humidifier at least 1 meter away from the TV or other objects that emit
radio waves.
Q: Why is the fire on the stove turning red?
A: The composition of tap water can react with the flame, so keep the humidifier
away from the stove.

Product Name Ultrasonic Humidifier
Model Number LCDJSQ-J39
Operation Mode Low Medium High
Safety Functions
1-12 hours Timer
Waterless auto shut-off
Automatic shutdown when falling
Product Specifications
17
Rated Power
Raterd Voltage
Noise
Tank Capacity
Size
N.W.
100W
100-240V~
≤35dB
6.6Gal / 25L
(W)460mm x (D)190mm x (H)1130mm
4.7Kg

Warranty Period
Our company provides a one-year warranty which starts from the date of purchase.
Warranty Requirements
provide the warranty card and the order number.
Send an e-mail to
Non-Warranty Policy
The following conditions are not covered by the warranty.
Damage caused by natural disasters or other force majeure events.
Failure or damage caused by forced use of the product.
The user disassembles or repairs the product without authorization.
Warranty
18
Please note that we cannot provide warranty service if you are unable to provide the above
information.
Thank you for choosing our product, and we hope you enjoy using it. If you have any
questions or concerns, please don't hesitate to contact us.
In order to receive warranty service, please follow these steps:
Describe the problems you are experiencing in detail and provide pictures or videos if
possible.
lf you need to return the product, please make sure that it is intact and the
packaging boxes and accessories are complete.
Damage that occurs after the warranty period has expired.