
Model / Modèle / Modelo:
TPFIT25WK/ TPFIT25AWK /
TPFIT32WK / TPFIT32AWK
Customer Support:
Assistance Au Client:
Servicio de atencion a clientes:
Web: www.HoneywellAirComfort.com
USA: 1-800-474-2147 | [email protected]
CANADA^: [email protected]
^ Canada Customer Support service available for models sold in Canada only.
^ Le Service Client Canadien est disponible uniquement pour les modèles vendus sur le territoire Canadien.
^ Servicio de Atención A Clientes en Canadá disponible solo para modelos vendidos en Canadá.
Check the website for FAQ's, usage guides and more!
Consultez le site Web pour les FAQ, les guides
d'utilisation et plus encore !
Consulte el sitio web para ver las preguntas
frecuentes, las guías de uso y mucho más.
www.HoneywellAirComfort.com
Contact UsProduct Registration
Portable Dehumidifier
User Manual
Read and save these instructions before use

1EN
For Models:
TPFIT25AWK / TPFIT32AWK
Smart Portable Dehumidifer with WiFi
Connectivity
The Smart Portable Dehumidifier has added features to allow you to operate the
dehumidifier remotely using a smart device, and to use voice commands through an
Amazon Echo device, to control the unit.
Set up the Honeywell Air Comfort App on your smart phone or tablet to connect the
Honeywell Smart Portable Dehumidifier for WiFi and Voice control (only available for
Smart Dehumidifier models).
1. Apps are frequently updated. Download the most recent App user manual from the
below link:
2. Download the Honeywell Air Comfort App on your smart phone or tablet.
IMPORTANT: A 2.4 GHz Wi-Fi network is required for proper connection and operation
between the Dehumidifier and the App. Other networks should be deleted,
as they can interfere with connectivity.
NOTE: The Smart Portable Dehumidifier does not have to be connected to the Honeywell
Air Comfort App to function. You can still operate manually using the unit’s
control panel.
iOS 9.0 or later
Android 4.3 or later
SEARCH “HONEYWELL AIR COMFORT”
SMART PORTABLE DEHUMIDIFIER
WITH WIFI CONNECTIVITY & VOICE CONTROL
https://honeywellaircomfort.com/pages/app-manuals

2
EN
THANK YOU
SAFETY RULES
Thank you for purchasing a Honeywell Portable Dehumidifier. This User Manual is intended to
provide you with important information needed to set up, operate, maintain and troubleshoot this
product.
WARNING -- READ AND SAVE THESE INSTRUCTIONS BEFORE USING THIS PRODUCT.
The use of electrical products may create hazards that include, but are not limited to injury, fire,
electrical shock. Failure to follow these instructions may damage and/ or impair its operation and
void the warranty. In case there is any inconsistency or conflict between the English version and any
other language version of the content of this material, the English version shall prevail.
When using electrical appliances, basic safety precautions should always be followed:
DO NOT touch the dehumidifier or the electrical plug with wet hands.
Check the household voltage to ensure it matches the appliance's specification.
Before operating, remove all packaging material and check for any damage that may have
occurred during shipping.
DO NOT operate any product with a damaged cord or plug.
DO NOT use an extension cord with this appliance.
DO NOT run power cord under carpeting, or cover it with rugs or runners. Keep the cord away from
areas where it may be tripped over.
Always power off and unplug the dehumidifier before emptying the water tank.
The water collected in the tank must be discarded. The water should never be used for drinking.
Always unplug the dehumidifier and remove the water from the water tank before cleaning,
servicing or relocating the unit.
Remove the power cord from the electrical receptacle by grasping and pulling on the power cord
plug-end only, never pull the cord.
This appliance has been manufactured for use in domestic environments and must not be used
for other purposes.
DO NOT use the product in areas where gasoline, paint or other flammable goods and objects are
used or stored.
This dehumidifier is designed for indoor residential applications only. It should not be used for
commercial or industrial applications.
DO NOT attempt to repair or adjust any electrical or mechanical functions of the dehumidifier,
as this may cause danger and void the warranty.
DO NOT cover the air inlet or outlet on the appliance as this may cause the unit to fail.
DO NOT insert or allow objects to enter any ventilation or exhaust opening as this may damage
the product and could cause electrical shock or fire.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•

3EN
DO NOT let children play with this appliance, packaging or included plastic bag.
If the unit is damaged or it malfunctions, do not continue to operate it. Unplug the product from
the electrical outlet. Refer to the troubleshooting section and contact the customer support
center.
Always place the dehumidifier on a leveled floor.
Never install the product near a bathtub or any water container.
Store in a dry area, away from direct sunlight, when not in use.
This appliance and its packaging materials are not intended for use by persons (including
children or elderly) with reduced physical, sensory or mental capabilities, or lack of experience
and knowledge, unless they have been given supervision or instructions concerning the use of
the appliance by a person responsible for their safety.
Always grip the top handle and keep the unit upright when transporting from room to room –
DO NOT tilt the product on its side or upside-down.
If the dehumidifier was transported tilted on its side, you must position it upright again and wait
at least 4 hours before using it.
WARNING: To reduce the risk of fire or electric shock, do not use this appliance with any solid
state speed control device.
•
•
•
•
•
•
•
•
•
SAFETY RULES (CONTINUED)

4
EN
SYMBOL NOTE EXPLANATION
WARNING
This symbol shows that this
appliance uses a flammable
refrigerant. If the refrigerant
is leaked and exposed to
an external ignition source,
there is a risk of fire.
CAUTION
This symbol shows that the
operation manual should be
read carefully.
CAUTION
This symbol shows that a
service personnel should
be handling this equipment
with reference to the
installation manual.
CAUTION
This symbol shows that
information is available,
such as the operating
manual or installation
manual.
R32 SAFETY
R32
A2L

5EN
R32 SAFETY
Read the instructions carefully before using the appliance.
R32 refrigerant gas complies with UL60335-2-40 / UL60335-1.
This appliance contains a certain number of grams (see rating
label at the back of the unit) of R32 refrigerant gas. The maximum
refrigerant charge amount is not greater than R32 0.105kg (For
TPFIT25) R32 0.11kg (for TPFIT32) based on UL60335-2-40.
When defrosting or cleaning, do not use any method other than
those recommended by the manufacturer.
Do not place the appliance in a room with continuous sources
of ignition (e.g. open flame, operating gas appliance, or working
electrical heater).
Do not pierce and do not burn.
Do not perforate any part of the refrigerant circuit.
Refrigerant gas may be odorless.
Accumulation of possible refrigerant leaks in an unventilated
room could lead to fire or explosion should the refrigerant come in
contact with electric heaters, stoves, or other sources of ignition.
The appliance must be stored in a way to prevent mechanical
damage and in a well-vented area.
Only individuals authorized by an accredited organization
certifying their competence to handle refrigerants in compliance
with industry legislation should work on the refrigerant circuit.
Servicing shall be performed only as recommended by the
manufacturer.
All working procedures that affect safety means shall only be
carried by competent persons.
Additional warnings for appliances with R32 refrigerant gas.
•
•
•
•
•
•
•
•
•
•
•
•
•
Repair must be performed based on the recommendations from the manufacturer.
Maintenance and repair that requires the assistance of other qualified personnel must be
performed under the supervision of specialists in the use of flammable refrigerants.

6
EN
Transport of equipment containing flammable refrigerants must
comply with local transport regulations.
Marketing of equipment using signs must comply with local
regulations.
Disposal of equipment using flammable refrigerants must
comply with national regulations.
The storage of equipment should be in accordance with the
manufacturer’s instructions.
Storage package protection should be constructed such that
mechanical damage to the equipment inside the package will
not cause a leak of the refrigerant charge.
The maximum number of pieces of equipment permitted to be
stored together will be determined by local regulations.
Transportation, marking, and storage for units.
1.
2.
3.
4.
5.
R32 SAFETY

7EN
HOW A DEHUMIDIFIER WORKS
When the dehumidifier is switched ON, a fan pulls moisture-laden air into the dehumidifier where it
passes through dehumidifying coils inside the unit. These coils condense moisture from the air
and collect it in the water tank. The dry air is then exhausted from the dehumidifier. The air flows
through the air vents of the dehumidifier into the room as dry, warm air.
IMPORTANT: The dehumidifier is designed to operate between 41°F (5°C) and 89°F (32°C).
The dehumidifier’s performance may be greatly reduced if room temperature is beyond this
temperature range.
Before using the dehumidifier, place the unit UPRIGHT for at least 1 hour before use to allow the
refrigerant to stabilize. If the unit was tilted on its side or upside-down during transportation, set
the unit upright for 4 hours before use.
For optimal efficiency, the dehumidifier must be operated in an enclosed area. Keep all doors,
windows and other outside entrances to the room closed.
•
•
SELECTING A LOCATION - IMPORTANT

8
EN
Place the dehumidifier in an area where the temperature will not drop below 41°F (5°C)
Place the dehumidifier at least 17.7 inches (45 cm) away from other objects (e.g. curtains or
furniture) that may restrict airflow from the back or through the air vents of the unit.
The dehumidifier must be positioned on a level floor.
•
•
•
SELECTING A LOCATION - IMPORTANT (CONTINUED)
17.7 inches (45 cm)
17.7 inches (45 cm)
IMPORTANT: The effectiveness of the dehumidifier can be influenced by different factors. One
factor is the rate at which new, moisture-laden air enters the room and the amount of air circulating
in and out of the area to be dehumidified. For example, if a door to a basement is constantly opened,
letting new, moisture-laden air into the room, dehumidification will take longer than if the door was
kept closed. If the dehumidifier is in a room with a storage closet or cabinets, it will have little or no
effect in drying the inside of the storage closet or cabinets unless there is adequate circulation of
air in and out of these spaces. To dehumidify these spaces, open the storage door or cabinet doors
to allow air circulation. You may find that installing a second dehumidifier may be required for larger
enclosed areas.

9EN
UNPACKAGING THE DEHUMIDIFIER
There is a Foam Float inside the water tank that senses the
water level to automatically stop dehumidification when the
water tank is full. Make sure the Foam Float is positioned
correctly inside the water tank by ensuring it lies level with the
top edge of the water tank.
DO NOT REMOVE THIS FOAM FLOAT.
This Dehumidifier is packaged with a colored or transparent tape to secure some parts during
transportation. Remove the colored or transparent packaging tape from the unit.
1. Gently pull the water tank from out of the dehumidifier
2. Remove the splash guard from the top part of the water tank.
3. Take out the power plug, drain hose and other accessories,
which is placed inside the tank of the dehumidifier.
4. Once all accessories have been removed. Make sure that the
tank is properly positioned.
Foam
Float
Splash
Guard

10
EN
PARTS DESCRIPTION
9
8
5
3
6
1
2
7
4
13
12
10
11
14
1) Control Panel 9) Washable Dust Filter
2) Handle 10) Direct Drain Outlet
3) Splash Guard 11) Direct Drain Cap
4) Foam Float 12) Cord Cable Tie
5) Water Tank 13) Power Cord & Plug
6) Water Level Indicator 14)
Continuous Water Drain Tube
Inner Dia: 0.5 in (1.27cm);
Length: 3.28 ft (1 m)
7) Casters
8) Dehumidified Air Exhaust Vent 15) Cord Winders
15
x2

11EN
Once you have removed the cord winder accessories from the water tank - follow the steps below.
INSTALL THE CORD WINDER
Step 2: Rotate 45-degrees clock-wise.
Step 1: Line up the cord winder pieces to the mounting holes.
Step 3: Once you hear “click”, then you know the cord winder is ready for use.
NOTE: Once the installation of the cord winder has been completed. The cord winder cannot be
removed. The installation is permanent.

12
EN
USE & OPERATION
1) Filter Indicator light 8) Power Control
2) Timer Indicator Light 9) Mode Controls
3) Water Full Indicator Light - Laundry Mode
4) Humidity / Timer Set Controls - Dehumidifying Mode
5) Filter Alert - Comfort Mode
6) Timer Control - Continuous Mode
7) Display Screen
CONTROL PANEL
(3)(2)(1)
(10)
(4)
(5) (6)
(8)(7)
(9)
10^) Wi-Fi Indicator light
^ THIS IS ONLY FOR MODEL TPFIT25AWK / TPFIT32AWK WITH
WIFI SMART FEATURES
NOTE: For detailed instructions to set up your dehumidifier for connected
operation from your smart phone or tablet, separate user manual can be
downloaded at:
https://honeywellaircomfort.com/pages/app-manuals

13EN
DISPLAY SCREEN
When the unit is switched ON, the Display Screen shows the current humidity percentage and
previous mode setting.
MODE SETTING
Settings: Laundry Mode, Dehumidifying Mode, Comfort Mode & Continuous Mode.
The corresponding indicator light will illuminate to indicate the current mode setting.
Dehumidifying Mode
Press or to adjust your preferred humidity level. Set the desired humidity in % by pressing
button, it will increase in increments of 5%. The adjustable Relative Humidity (RH) range is between
30% RH to 90% RH. Two seconds after setting the preferred humidity setting, the display will revert
back to displaying the current humidity,
Dehumidifier maintains a balanced low speed for whole room dehumidification.
Adjust humidity level as desired (30%RH to 90%RH).
Laundry Mode
Adjust desired humidity level by pressing or as described in Dehumidifying Mode .
Dehumidifier runs on high speed for more powerful dehumidification intended for drying clothes.
Hang wet clothing in the same room as the dehumidifier, taking care not to allow wet clothes to be
hung over the dehumidifier or cause any water to drip onto the dehumidifier.
Close windows and doors for faster laundry drying.
FUNCTION BUTTONS
USE & OPERATION (CONTINUED)
POWER CONTROL
Press to switch the dehumidifier ON or OFF.
WI-FI PAIRING^
Before turning on Dehumidifier, press the button 6 times within 4 seconds to start WIFI pairing
mode. The display sreen will show “CF” when in Wi-Fi pairing mode. When the Smart Dehumidifier is
connected to the wifi function, the indicator light will be illuminated.
^ THIS IS ONLY FOR MODEL TPFIT25AWK / TPFIT32AWK WITH WI-FI SMART FEATURES

14
EN
Comfort Mode
Dehumidifier automatically adjusts dehumidification Relative Humidity (RH) percentage settings
based on ambient room temperature, for hassle-free operation.
When ambient room temperature is 18°C / 64°F or lower, the dehumidifier adjusts to 55% RH.
When ambient room temperature is between 18°C / 64°F and 25°C / 77°F, the dehumidifier adjusts
to 50% RH.
When ambient room temperature is 25°C / 77°F, or above, the dehumidifier adjusts to 45% RH.
Display Sleep Mode
The top display dims after 1 minute of button inactivity, and then turns off after 3 minutes of inactivity.
Display lights up again when any button is pressed. Mode indicator lights remain ON in display sleep
mode to indicate current settings.
Continuous Mode
The dehumidifier runs continuously with a target of 30%RH or below, on low speed setting. This
mode is used for rooms with more severe dampness and needs continuous dehumidification.
Desired humidity level cannot be adjusted in this mode and will need to be manually switched OFF,
unless unit stops due to a full water tank.
WATER TANK FULL ALERT
When the Water Tank is full, the indicator will be illuminated. The unit will beep for 3 seconds.
The compressor and fan will shut off at the same time. To switch off the indicator light, empty the
water tank and when replacing it ensure the tank is secured properly in place.
IMPORTANT: Do not place the Water Tank on the floor when full. In case of an uneven base which
may cause the tank to spillover.
FUNCTION BUTTONS (CONTINUED)
USE & OPERATION (CONTINUED)

15EN
USE & OPERATION (CONTINUED)
FILTER ALERT
When the Filter Alert Light is ON, it is time to clean the filter. Switch the unit OFF and carefully
remove the filter from the unit and clean. Replace the filter and switch ON the unit.
The Filter Alert Light should not be illuminated until the filter requires cleaning again. The frequency
of filter cleaning depends on room environment conditions. Some rooms may require changing more
frequently than others.
NOTE: To cancel the filter alert, simply press
, and indicator light will disappear.
Auto-On Timer:
When unit is in Standby Mode, press , the timer indicator light will flash, press or to
select the number of hours (0.5-24 hours) until you want the unit to automatically start running. In
5 seconds without the operation, the Timer start function, the timer indicator light is illuminated.
You could decide the mode and adjust the humidity level that you preferred, then the unit will turn on
and continue running until the water tank is full (unless the unit is set up for continuous draining) or
until you switch it off manually. Timer must be set again after each use.
NOTE: To cancel any Timer settings, simply press again, and the timer indicator light will
disappear.
Auto-Off Timer:
While the unit is running, press , the timer indicator light will flash, press or to select
the number of hours (0.5-24 hours) you want the unit to run before it switches off. In 5 seconds
without the operation, the Timer start function, the timer indicator light is illuminated. Timer
must be set again after each use.
TIMER CONTROL
The dehumidifier can be set to automatically switch ON or OFF for a selected period of time (between
0.5-24 hour intervals). The Timer hours selection is displayed on the Display Screen.
NOTE: Before setting the Timer control, make sure there is power to the unit.

16
EN
USE & OPERATION (CONTINUED)
AUTO RESTART FUNCTION
AUTOMATIC DEFROST
This unit is equipped with an Auto Restart feature. When there is a power outage, the dehumidifier
should automatically resume all its previous settings upon regaining power. If it doesn't, simply
Power ON the unit and reset the settings as desired.
Frost may build up on the internal coils of the unit. When there is frost build up, the internal
compressor will turn off and the fan will continue to run until the frost has melted. Once the internal
coils have defrosted and dried, the compressor or fan will automatically restart and dehumidifying
will resume.

17EN
The condensed water can be collected directly into the water tank. When the water tank is full, the
dehumidifier will automatically shut OFF and the indicator will illuminate on the control panel
followed by a beeping sound.
IMPORTANT: Do not move the dehumidifier when the Water Tank is full as it will be heavy and can
cause water spillage.
USE & OPERATION (CONTINUED)
DRAINING THE WATER
WARNING: Always drain and discard water collected from dehumidification.
The water is not clean and cannot be used for drinking.
IMPORTANT: Improper alignment or positioning of the
water tank will cause the unit to pause operation, the
warning light on top of the dehumidifier will illuminate
followed by a beeping sound, until the water tank is fitted
properly.
NOTE: There is a Foam Float inside the water tank
that senses the water level to automatically stop
dehumidification when the water tank is full. Make sure
the Foam Float is positioned correctly inside the water
tank by ensuring it lies level with the top edge of the
water tank.
DO NOT REMOVE THIS FOAM FLOAT.
Locate the water tank at the front of the dehumidifier.
Gently pull the water tank out.
Carry the water tank to a sink to empty.
Replace the empty water tank back into the front of
the dehumidifier. Please make sure that the tank is
properly positioned. The safety feature ensures that
any misalignment of the tank and the unit will prevent
the unit from turning back on.
1. Draining water collected in the Water Tank
1.1
1.2
1.3
Foam Float
1.1
1.2

18
EN
DRAINING THE WATER (CONTINUED)
USE & OPERATION (CONTINUED)
Locate the drain outlet at the back of the unit. Unscrew and remove the Direct Drain Cap.
Insert and screw the Continuous Water Drain Tube into the Direct Drain Outlet.
2.1
A continuous water drainage tube is included with this unit. To activate the continuous water draining
function, you will require a suitable water drain (e.g. sink or drain hole at floor level)
near the dehumidifier.
2. Continuous Water Drainage – Using a Continuous Water Drain Tube
Direct Drain Cap
Continuous
Water Drain Tube
Continuous Water
Drain Tube
3.28 ft. (1 m)
Continuous Water Drain Cap

19EN
If there are leaks, the Continuous Water Drain Tube and Cap may have loosened and may not be
connected properly. Disconnect, replace and tighten again.
Position the other end of the Continuous Water Drain Tube in the sink or drain. Make sure the
tube is not bent or kinked which might stop the water flow. Make sure the tube is secured over
the drain and will not fall out of place causing unwanted water spillage.
2.2
2.3
IMPORTANT: Make sure water can flow down the Continuous Water Drain Tube by keeping the tube
angled down and free of bends or kinks.
IMPORTANT: If the unit is placed on uneven ground, or the Drain Tube is installed incorrectly, the
water may fill the water tank and stop running. Please check whether the ground is uneven and
reinstall the Drain Tube.
DRAINING THE WATER (CONTINUED)
USE & OPERATION (CONTINUED)

20
EN
CLEANING & MAINTENANCE
USE & OPERATION (CONTINUED)
Switch off and unplug the dehumidifier from the
electrical outlet.
Carefully pull out the dust filter from the
dehumidifier.
Rinse the dust filter under running water, or
vacuum away the dust with a vacuum cleaner.
After cleaning the dust filter, dry in a cool, shaded
place, then carefully reinstall into the unit.
1.
2.
3.
4.
WARNING: Always switch OFF the dehumidifier and unplug it from the electrical outlet before
attempting any cleaning or maintenance of this product.
Appliance Maintenance:
• Switch OFF the appliance before disconnecting the power supply.
• Only use a soft cloth to clean the appliance.
Dust Filter Maintenance:
The Dust Filter located at the back of the unit helps to remove dust particles from the air. A dirty filter
clogged by dust particles can reduce the efficiency of the dehumidifier. For optimum
dehumidification, it is recommended to clean the dust filter every 2 weeks:
End of Season Storage & Maintenance:
Switch OFF the unit and unplug from the electrical power outlet.
Empty the water tank and let it dry. If your dehumidifier is connected to the continuous drain
hose, you must disconnect the hose, dry and then replace the drain cap back into the drain outlet.
Remove the air filter and clean with water. Let the air filter dry and reinstall back into the unit.
Make sure all parts of the dehumidifier and accessories are dry before storage.
Cover the dehumidifier with a cloth/ plastic bag before storage, to protect the surface from dust
and scratches.
It is recommended to coil the power cord and store it off the floor to ensure it is protected from
bends and kinks.
Store the unit upright in a dry location, away from direct sunlight.
•
•
•
•
•
•
•
If the appliance will not be used for an extended period of time:

21EN
TROUBLESHOOTING GUIDE
The following troubleshooting guide addresses the most common problems. If problems persist, call
customer service.
PROBLEM POSSIBLE CAUSE SOLUTION
Dehumidifier
does not start
No electricity. Check for power.
The power cord is not
properly plugged in.
Remove and reconnect the power cord.
The water tank is not in
the correct position.
Position the water tank correctly into the unit. Unit
will not operate until the water tank is secure in place.
Unit runs but
the humidity
level does
not decrease
The humidity level setting
is too high.
Decrease the humidity level setting.
A door or window is open,
letting in new moisture.
Make sure all windows or doors to the
outside are closed and tightly sealed.
There are other sources
of humidity in the room
(e.g. boiling water in pot).
Switch on the dehumidifier when these
sources are not present.
The temperature in the
room is too low.
The dehumidifier is designed to operate between
41°F (5°C) and 89°F (32°C). Moisture removal is
greatly reduced if room temperatures exceed this
temperature range.
The dust filter is dirty/
blocked.
Clean the dust filter.
Air outlet or intake is
blocked, or drain outlet or
drain tubes are blocked.
Remove blockage.
For more troubleshooting steps please visit:
https://honeywellaircomfort.com/pages/portable-dehumidifier-faqs

22
EN
TROUBLESHOOTING GUIDE (CONTINUED)
PROBLEM POSSIBLE CAUSE SOLUTION
Unit runs but
the humidity
level does
not decrease
Insufficient time for the
dehumidifier to remove
moisture.
After initial installation, allow 24 hours to maintain
desired dryness.
Dehumidifier
runs constantly/
does not stop
Area to be dehumidified
is too large.
The capacity of your dehumidifier may not be
adequate for the room it is used in. It is recommended
to add an extra dehumidifier for large areas.
A door or window is open,
letting in new moisture.
Make sure all windows or doors to the
outside are closed and tightly sealed.
Water Tank
Full is
illuminated
and the unit is
beeping
The water tank is full. Empty the water tank.
The water tank is not in
the correct position.
Position the water tank correctly into the unit. Unit
will not operate until the water tank is secure in place.
The unit is
blowing cold air
out of the top
vent
The purpose of the top
air vent is to distribute air
into the room.
The temperature of the air from the vent depends
on the room environment and other factors. It can
fluctuate and this is normal. No action required.
Frost appears
on the coils
Dehumidifier has been
recently turned on in low
room temperatures
(usually below 41°F
(5°C)).
Frost can be a normal occurrence. Switch OFF the
dehumidifier and let the frost melt completely,
before turning the unit ON again. Make sure room
temperature is above 41°F (5°C) before turning On
again.
Connected
the continuous
drain but
the water
condensation is
not draining out
the tube
Some floors may have
an uneven surface
which may affect the
continuous drainage
function
Raise the front of the Dehumidifier ½ to 1 inch
(1.27 cm to 2.54 cm) from the floor. The water
condensation will drain out the back hose and not
into the bucket.

23EN
TROUBLESHOOTING GUIDE (CONTINUED)
PROBLEM POSSIBLE CAUSE SOLUTION
Water on
the floor
The garden hose/ drain
hose may be loose.
Check the connections between the hose and the
drain outlet on the unit. See Continuous Water
Drainage section.
Check the tube of cap for tighten.
You intended to use the
water tank to collect water
but the continuous drain
hose is still connected.
Disconnect the hose and replace the rubber stopper
and drain cap if using the water tank to collect water.
See Continuous Water Drainage section.
Noise
Fan is working.
Wind from the fan can create sounds during
operation. This is a normal sound.
Compressor is working.
There is a sound when the compressor turns on.
The compressor will activate periodically based on
humidity settings. This is normal.

24
EN
ERROR CODE GUIDE
CODE POSSIBLE CAUSE POSSIBLE SOLUTIONS
EH
Humidity Sensor
misalignment,
malfunction or
connection issue.
If the display shows “EH” flashing 3 times, it indicates the
humidity Sensor may not be working . When this happens,
the dehumidifier can still continue to function without
the sensor, by setting the target humidity and turning off
manually when it has reached the target setting. Alternatively,
you can set the Timer to set the unit to turn off/ on after a set
time period. The tank full alert will continue to function as
usual. The humidity sensor is not a part that can be replaced
in this model.
E2
Possible temperature
sensor issue.
Reset the Unit: Turn dehumidifier OFF and unplug from power
source for 24 hours and turn ON again.
Contact Customer Support if the code reappears.
E3
Refrigeration System
Protection
If E3 appears, check if the ambient room temperature has
exceeded 89.6
o
F (32
o
C). If yes, the unit may not run until the
room ambient temperature has reduced to below 86
o
F (30
o
C)
for at least 2 hours, or try to remove the unit to a cooler room
for at least 2 hours before running dehumidification mode
again.
Reset the Unit: If the code reappears, turn dehumidifier OFF
and unplug from power source for 24 hours and turn ON
again in a room with temperature below 86°F (30°C).
Contact Customer Support if the code reappears.

JMATEK North America LLC
Alpharetta, Georgia 30005 USA
Phone : 1-800-474-2147
Email : [email protected]
Web : www.HoneywellAirComfort.com
Made in China
© 2024 JMATEK Limited. All rights reserved.
The Honeywell Trademark is used under license
from Honeywell International Inc.
Honeywell International Inc. makes no
representations or warranties with respect to this product.
This product is manufactured by Airtek Int'l Corp. Ltd.
(subsidiary of JMATEK Ltd.).
