RHEEM
®
CLASSIC PLUS
®
SERIES
INDUCED DRAFT WATER HEATER
BIG POWER
SMALL SIZE
HELP HOMEOWNERS ENJOY MORE
HOT WATER & SAVINGS TODAY!
RHEEM
®
CLASSIC PLUS
®
SERIES
INDUCED DRAFT WATER HEATERS
More hot water without taking up more space—
plus energy savings & easy install
Call 1-866-621-5622, visit Rheem.com/InducedDraft
or see your local distributor.
1
Standard 40-gallon tank defined as an atmospherically vented 40-gallon, 40,000 BTU/h gas water
heater with a UEF of .58.
2
Estimated energy cost based on a national average fuel cost of $1.09/
therm for natural gas and $2.41/gallon for LP. Energy factor determined by the U.S. Department
of Energy (DOE) test procedures.
3
Requires double wall B-vent; Contractor should ensure existing
venting is installed properly and meets all current state and local codes.
4
Based on review of first
hour delivery ratings for Rheem and major competitor’s standard 40-gallon atmospheric natural
gas tank-type water heaters.
5
See the Warranty Certificate for additional information.
6
Requires an
electrical outlet.
7
PROG40-40N takes 9.43 minutes to drain and the PRO+G29-60N (XR90) takes
7.07 minutes meaning the XR90 empties 25% faster.
Uniform Energy Factor based on Department of Energy (DOE) test procedures.
SELLING GUIDE | INDUCED DRAFT WATER HEATER
A 29-gallon
tank that
outperforms
standard
40-gallon
tanks
1
EASY TO SELL
• Hot Water Delivery offers 60,000 BTU/h Low NOx burner,
93 gallon FHR, 61 GPH (@90°F rise)
• Produces up to 58%
4
more hot water than
40-gallon models
• Offers a .71 UEF costing only $208 per year to operate
• Guardian System FVIR includes our filter and
maintenance-free safety system
• Premium-grade anode rod and Rheemglas
®
lining
extends tank life
• Includes 8-year warranty
5
with 12-year upgrade option
EASY TO INSTALL
• Lightweight design allows quick, one-man install
• Installs like a standard gas water heater using a
110V plug
6
EASY TO SERVICE
• Quickly identify issues with self-diagnostic system
• Faster servicing with enhanced-flow brass drain valve
• Smaller tank empties 25% faster than standard
40-gallon tank
7
Rheem Water Heating | 1115 Northmeadow Parkway, Suite 100, Roswell, Georgia 30076
Rheem.com
In keeping with its policy of continuous progress and product improvement,
Rheem reserves the right to make changes without notice.
PRINTED IN U.S.A. • WP • 04.25-RH-PRO+-ID-BI

MORE COMPACT
The Classic Plus
®
Induced Draft
Water Heaters fit in a smaller space
than standard 40-gallon models.
DESCRIPTION
GAL.
CAP.
MODEL NUMBER
HEIGHT TO
TOP OF VENT
DIAMETER
HEIGHT TO
GAS CONN.
29 PRO+G29-60N RH70 ID 65-1/2" 17-3/4" 14"
DIMENSIONS
VENT SIZE
WATER CONN.
CENTER
HEIGHT TO
SIDE TAP
WATER
CONN.
SHIP WEIGHT
(LBS)
3" or 4" 8" 51-9/16" 3/4" 136
AVOID VENTING
3
REPLACEMENT WITH
THESE INSTALLATION OPTIONS:
Type B Double-Wall 3" Gas Vent
•
Single, Category 1 Fan Assisted Appliance
• 3" Vent Diameter
Vent Connected Directly to Appliance
(Ref Table 13.1(a) in Natl. Fuel Gas Code)
Maximum allowed horizontal venting = 15'
Before horizontal venting is allowed,
10' of total minimum vertical rise is required
Minimum vertical rise for this horizontal
venting = 30'
Maximum vertical rise = 50'
Vent Connected w/ Single Wall
Metal Connector
(Ref Table 13.1(b) in Natl. Fuel Gas Code)
Maximum allowed horizontal venting = 5'
Before horizontal venting is allowed,
10' of total minimum vertical rise is required
Minimum vertical rise for this horizontal
venting = 15'
Maximum vertical rise = 50'
Type B Double-Wall 4" Gas Vent
• Single, Category 1 Appliance
• 4" Vent Diameter
Vent Connected Directly to Appliance
(Ref Table 13.1(a) in Natl. Fuel Gas Code)
Maximum allowed horizontal venting = 30'
Before horizontal venting is allowed,
6' of total minimum vertical rise is required
Minimum vertical rise for this horizontal
venting = 30'
Maximum vertical rise = 100'
Maximum allowed horizontal venting = 30'
Before horizontal venting is allowed,
6' of total minimum vertical rise is required
Minimum vertical rise for this horizontal
venting = 30'
Maximum vertical rise = 100'
Vent Connected w/ Single Wall
Metal Connector
(Ref Table 13.1(b) in Natl. Fuel Gas Code)
GALLONS
70
60
50
40
30
20
10
RECOVERY
Classic Plus
®
Induced Draft
Standard
40-Gallon Tank
38.4
61
The recovery rate exceeds
the 40-gallon models by
58%, based off a 90°F rise.
GALLONS
90
85
80
75
70
65
60
FIRST HOUR RATING
Classic Plus
®
Induced Draft
Standard
40-Gallon Tank
64
93
First-hour performance
of Induced Draft exceeds
most 40-gallon models.
MORE HOT
WATER, FASTER
1
300
250
200
150
100
50
DOLLARS
ANNUAL OPERATING COST
Classic Plus
®
Induced Draft
Standard
40-Gallon Tank
$260
$208
SAVES MONEY
Costs only $208 annually
to operate, a rate 21% lower
than 40-gallon models based
on FTC Energy Guide Labels.
Induced Draft delivers a
.71 UEF, is ENERGY STAR
®
qualified and operates at a
rate 22% higher energy
efficiency
.70
.60
.50
.40
.30
.20
.10
ENERGY FACTOR (EF)
ENERGY EFFICIENCY
Classic Plus
®
Induced Draft
Standard
40-Gallon Tank
.58
.71
MORE EFFICIENT
2
Call 1-866-621-5622, visit Rheem.com/InducedDraft
or see your local distributor. Rheem.com
SEE HOW THE CLASSIC PLUS
®
INDUCED DRAFT STACKS UP
AGAINST 40-GALLON TANK
Horizontal Venting
Vertical Venting
17-¾"
19 -½"