21
SETUP INSTRUCTIONS
LEAK TEST PROCEDURE
--------------------------------------------------------------------------------------
Although gas connections on the Wok Station are leak tested prior to shipment, we recommend conducting a leak
test after initial setup and every time an LP cylinder is attached. In addition, we recommend performing a leak test
once a year. If the unexpected smell of gas is detected at any time a full leak test should be performed.
1. Create a solution of 80% water and 20% liquid soap in a spray bottle.
2. Connect the LP cylinder to the product by following the steps in the earlier section “CONNECTING THE LP
CYLINDER”.
3. Turn the LP cylinder valve counterclockwise to open the valve.
4. Apply soap to all gas ttings focusing on the connection points at the LP Cylinder and the Control valve.
Recommended locations to check are circled in the illustration. Soap bubbles will expand if there is a leak.
5. If a leak is discovered immediately turn the gas supply off and tighten any loose ttings.
6. Turn the gas back on and recheck.
7. If the leak continues turn off all gas and disconnect the LP cylinder. Contact our customer care team for further
assistance at 866-994-6390 or email [email protected].
WARNING: Check all gas supply ttings for leaks regularly. Do not use the Wok Station until all connections
have been checked and do not leak. Do not smoke while leak testing. Never leak test with an open ame.