Network Video Recorder User Manual
64
defined virtual region.
Steps
1. Go to Configuration Event Smart Event Intrusion.
2. Set Camera.
3. Turn on Enable.
4. Optional: Check Save VCA Picture to save the captured pictures of VCA detection.
5. Set the detection rules and detection areas.
1) Set Arming Area. Up to 4 arming areas are selectable.
2) Adjust Time Threshold and Sensitivity.
Sensitivity
The size of the object that can trigger the alarm. The higher the value is, the more easily
the detection alarm will be triggered. Its range is [1-100].
Time Threshold
Range [1s-10s], the threshold for the time of the object loitering in the region. When the
duration of the object in the defined detection area is longer than the set time, the alarm
will be triggered.
3) Optional: Set Target Detection as Human or Vehicle to discard alarms which are not
triggered by human body or vehicle.
Note
This function is only available for certain models.
4) Click Draw Area and draw a quadrilateral in the preview window by specifying four vertexes
of the detection region.
6. Set the arming schedule. Refer to Configure Arming Schedule for details.
7. Set the linkage actions. Refer to Configure Alarm Linkage Action for details.
8. Click Apply.
Region Entrance Detection
Region entrance detection function detects people, vehicles or other objects which enter a pre-
defined virtual region from the outside place, and some certain actions can be taken when the
alarm is triggered.
Steps
1. Go to Configuration Event Smart Event Region Entrance.
2. Set Camera.
3. Turn on Enable.
4. Optional: Check Save VCA Picture to save the captured pictures of VCA detection.
5. Set the detection rules and detection areas.
1) Set Arming Area. Up to 4 arming areas are selectable.