11
English
Below is the pinouts for the DI/DO terminal block for 23A/23B/23C/23D/23E-v2/23F-v2
Facing the rear side of the housing, from left to right:
DO2 Tank water pump control
DI2 Wiper control, connects to IP camera's DO for manually triggering washer.
RS485+ RS485+, RS485 can be used to control IR illuminator beam angles, etc.
RS485- RS485-
DO+ +5V VCC
DI- GND
DO1 IR LED status, connects to IP camera's DI for IR status
DI1 IR control, synchronizes day/night mode switching for IP camera. It is related to IR
The AE-239/244 support DO signal from IR control board.
DO+ IR LED status, connects to IP camera's DI for IR status
DO- GND