Interface
The tumble dryer can be installed with an XKM 3200 WL PLT
communication module.
This module can be used as a WiFi or LAN interface.
The LAN interface provided via the module complies with SELV
(Safety Extra Low Voltage) in accordance with EN 60950. Connected
appliances must also comply with SELV. The LAN connection uses a
RJ45 connector in accordance with EIA/TIA 568-B.
Installation and anchoring
The machine must be installed on a perfectly smooth, level, and firm
surface which is able to withstand the quoted loads.
The floor load created by the appliance is concentrated and
transferred to the installation footprint via the machine feet.
The tumble dryer should be leveled in both directions with the aid of
the adjustable feet.
Plinth installation
The tumble dryer can be installed on a machine plinth (open or box
plinth, available as an optional Miele accessory) or on a concrete
plinth to be provided on site.
The quality of the concrete and its strength must be assessed
according to the machine load. Ensure that any raised concrete plinth
is adequately bonded to the floor below.
Washer-dryer stack
The tumble dryer can be installed as a washer-dryer stack together
with a Miele Washing Machine. A stacking kit (optional accessory)
is required for this.
Installation of the stacking kit should be performed by Miele Technical
Service or an authorized Miele service technician.