FLUKE TI300+ 60HZ Ti300+ Thermal Imaging Camera, 320 x 240, -4 to 1202°F

User Manual for the Fluke Ti300+ Thermal Imaging Camera, 320 x 240, -4 to 1202°F - Page 22

For TI300+ 60HZ.

PDF File Manual, 54 pages, Read Online | Download pdf file

TI300+ 60HZ photo
Loading ...
Loading ...
Loading ...
Ti300 PRO, Ti300+, Ti400 PRO, Ti401 PRO, Ti450 PRO, Ti450 SF6, Ti480 PRO
Users Manual
18
Image Menu
Table 10 lists the options in the Image menu.
Table 10. Image Menu
Option Menu Option Description
Palette
Standard
Select the palette to use.
The Standard Palettes offer an equal, linear presentation of colors
that allow for best presentation of detail.
The Ultra Contrast Palettes offer a weighted presentation of
colors. Ultra Contrast palettes work best in situations with high
thermal contrast for extra color contrast between the high
temperatures and low temperatures.
See Detailed Specifications.
Ultra Contrast
Set Palette Changes the palette color.
Saturation
Colors
Turns on/off Saturation Colors.
If Saturation Colors is on, you can set the saturation colors to use.
IR-Fusion <options>
Select to set the IR-Fusion mode. See Detailed Specifications for
modes available based on the model of the Imager.
The Imager automatically captures a visible image with every
infrared image to show where a potential problem might be.
Note
The visible image and infrared image can be customized or
separated in SmartView and Fluke Connect Software when
you use the .is2 or .is3 file format. See File Format.