106
not trigger detection.
8. Click Stop Drawing when finish drawing.
9. Set the time threshold for object removal detection.
Threshold: Range [5-100s], the threshold for the time of the objects removed from
the region. If you set the value as 10, alarm is triggered after the object disappears
from the region for 10s.
10. Drag the slider to set the sensitivity value.
Sensitivity: Range [1-100]. It stands for the percentage of the body part of an
acceptable target that leaves the pre-defined region.
Sensitivity = 100 S
1
/S
T
*100
S
1
stands for the target body part that leaves the pre-defined region. S
T
stands for
the complete target body.
Example: if you set the value as 60, a target is possible to be counted as a removed
object only when 40 percent body part of the target leaves the region.
Note: The Sensitivity of the detection is supported by certain models. Refer to
actual display for details.
11. Repeat the above steps to configure other regions. Up to 4 regions can be set. You
can click the Clear button to clear all pre-defined regions.
12. Click Arming Schedule to set the arming schedule.
13. Click Linkage Method to select the linkage methods.
14. Click Save to save the settings.
Chapter 10 Storage Settings
Before you start:
To configure record settings, please make sure that you have the network storage
device or local storage device configured.
Configuring Record Schedule
Purpose:
There are two kinds of recording for the cameras: manual recording and scheduled