30 en | RE3-RX receiver RE3 UHF Wireless
02-2023 | 05 | F.01U.362.808
User Manual
Electro-Voice
1. Press the ▼ button to scroll down to Frequency on the main menu. Select by pressing
SET to enter the Setup Frequency screen.
M
1. Scan
E
2. Frequency
N
3. Group/Channel
U
4. Squelch
2. The three digits to the left of the decimal are in millions (MHz) and are highlighted.
Pressing ▲ increases frequency in increments of 1 MHz per press, pressing ▼ decreases
frequency in increments of 1 MHz per press. Press SET to move to the next set of three
digits.
581 . 725
MHz
G:5 CH:12
Setup Frequency
3. The three digits to the right of the decimal are in thousands (kHz). Pressing ▲ increases
frequency in increments of 25 kHz per press, ▼ decreases frequency in increments of 25
kHz per press.
The G:_ _ and CH: _ _ under the frequency will populate when a preset group and channel
match the frequency dialed in.
581 . 725
MHz
G:5 CH:12
Setup Frequency
4. Press SET to save the custom frequency and to exit to the main menu.
M
1. Scan
E
2. Frequency
N
3. Group/Channel
U
4. Squelch
5. Either scroll ▼ to Exit and press SET, or briefly press SYNC on the receiver front panel to
return to the home screen.
M
9. Keylock
E
a. Display Option
N
b. Reset
U
c. Exit
7.3.8 Manually setting group and channel
Setting group and channel manually does not benefit from the scan function of locating clear
channels. It is import to note that manually entered group/channel combination may
experience interference, which can be avoided by using the scan function.
1. Press the ▼ button to scroll down to Group/Channel on the main menu. Select by
pressing SET to enter the Setup Group screen.