Raydrop KC-RD06 Cool Mist 2.2L Humidifiers 28dB Whisper-Quiet Ultrasonic

User Manual

For KC-RD06.

PDF File Manual, 20 pages, Read Online | Download pdf file

KC-RD06 photo
FUNCTIONS
Need any help?
Please contact us and we will give you a response
within 1 working day.
Thank you for choosing our humidier.
Please read the following instruction cafefully before use!
Package Contents
Humidier × 1 User Manual × 1
Humidify Your Room , Make You Feel Good
Humidifier
Model:
KC-RD06
STATEMENT
Thank you for purchasing raydrop product that has been tested
to meet our stringent quality standards. This product is covered
with raydrop product and labor warranty for 12 months from the
date of its original purchase.
SAFETY INSTRUCTIONS
Please email us with your order ID and problem or issue, we will
respond within 24 hours.
Please read the User Manual thoroughly. Clean and maintain
the product as instructed. If any abnormalities occur, please
refer to the Troubleshooting Guide rst.
This warranty is void if the defect is caused by accidental
damage. misuse, abuse, neglect, improper repair or alteration
by unauthorized persons, or a failure to follow operating
instructions provided with the product including adding
essential oils directly into the tank and base. This warranty does
not apply to normal wear and tear or commercial use.
In no event shall liability exceed the purchase price paid by the
purchaser of the product. Under no circumstances shall there
be liability for any loss - direct, indirect of incidental - or
consequential damage arising out of, or in connection with the
use of the product.
The humidier was made with safe and environmental
protection materials, it has been certied and compiled with
the requirement of sale regions' related regulations or laws.
IMPORTANT: Please read and save this SAFETY INSTRUCTIONS
before using the device. Basic precautions should always be
followed to reduce the risk of re, electrical shock, and injury to
persons or damage to the product.
1. Please always place the unit on a smooth, at, lint-free, non-
metallic, waterproof and level surface and keep it away from
direct sunlight.
2. Always place the unit 12 inches (30 cm) away from the wall
other appliances or wooden furniture.
BEFORE USING THE HUMIDIFIER
1.Please check the cord for any signs of damage.Do not use the
humidier if the cord has been damaged.
2.DO NOT place this humidier in wet environments.
Please always keep the humidier out of reach of patients &
children & pet.
WHEN USING THE HUMIDIFIER
1. Always disconnect from a power source by pulling out the plug
when not in use.
2. Humidier requires regular cleaning. Please refer to, and follow
the Cleaning and Maintenance instructions..
AFTER USING THE HUMIDIFIER
1. DO NOT clean the humidier right after turning it off if the
humidier is warm to touch.Allow the humidier to
completely cool down before cleaning.
2. DO NOT attempt to repair or adjust any electrical or mechanical
functions on this humidier.Doing so will void your warranty.
PRODUCT DIAGRAM
1
2
4
3
6
8
5
9
10
11
12
1. Mist Outlet
2. Water Tank
3. Water Inlet
4. Tank Cap
5. Base
6. LED Indicator
7. Light Switch
8. Control Knob
9. Air Outlet
10. Water Reservoir
11. Atomizer
12. Air Inlet
SPECIFICATIONS
Model
Operating Voltage
Water Tank Capacity
Mist Output
Working Time on a Full Tank
Recommended Room Size
Noise
Dimensions
Net Weight
KC-RD06
110V
2.2L / 0.58Gal
Max: 230ml/h
9-36h
20-30/ 215-322ft²
30dB(A)
245*165*210mm
0.8KG/29oz
OPERATIONS AND FUNCTIONS
1.Turn the water tank upside down.
2.Remove the tank cap and ll the tank with clean and cool
water only.
3.Attach the tank cap.
1
2 3
4.Place the tank back to onto the base.
5.Plug the power cord into a wall socket.
6.Rotate the control knob clockwise to the ON position.
4
5 6
1.If tap water is too hard, it is recommended to use ltered or
distilled water to avoid white dust. DO NOT use hot water.
2.DO NOT add any essential oils or medicinal tablets into the
water tank.
3.DO NOT add water into the base or through mist outlet.
4.DO NOT move the humidier while the water tank is full of
water to avoid leakage or base overlling.
TIPS
!
1 2
!
3 4
Plug the power cord into a wall socket. Now the humidier is
ready for use.
1. Rotate the control knob clockwise to the ON position. The
green LED indicator will light up indicating that the humidier
has been turned on .
2. Keep rotating the control knob clockwise to increase the
mist level.
3. Rotate the control knob counter clockwise to decrease the
mist level.
4. Rotate the control knob counterclockwise to the OFF position
to tum off the humidier. The LED indicator will turn off.
Power On / Off and Mist Adjustment
The most comfortable environmental humidity is between
40%-60%, please adjust the mist output as needed.
NOTE:
Low Water Protection: Auto Shut-off the Humidier
When there is not enough water inside the water reservoir,
the humidier will stop misting and the LED indicator will
become red. It is designed for safety concern to prevent the
humidier from possibly overheating and damaging the
atomizer.
CLEANING AND MAINTENANCE
Caution
1. DO NOT submerge the base in water.
2. Make sure water does not enter the base
through the air outlet, air inlet, or the control
knob and light button.
3. DO NOT wash any part of this humidier in
dish washer which will damage the
humidier and void the warranty.
Daily Maintenance
Turn off the humidier, unplug it from the power source. Drain
water from the tank, reservoir and base.
SCALE REMOVAL INSTRUCTIONS
3. Fill the water tank half full. Add 1 teaspoon of undiluted
distilled white vinegar. Attach the tank cap and shake the tank
for 15 seconds.
4. Place the tank onto the base. The vinegar solution will enter
the water reservoir to loosen mineral buildup (scale) on the
atomizer. Set it still for 15-20 minutes.
5. Uncap the tank cap and drain the solution. Wipe the atomizer
with a soft cloth to remove loosened mineral deposits.
6. Rinse both the water reservoir and water tank until the smell
of vinegar (for scale removal) or bleach solution (for disinfecting,
see below) is gone.
15S
1 2
3 4
5 6
1. Turn off and unplug the humidier.
2. Remove the water tank from the base. Remove the tank cap.
Make sure that the white sealing ring does not come off.
Drain water from the water tank and base. Remove any
accessories and set them aside.
2.DO NOT mix vinegar and bleach solutions together. Do not
use more than 1 tsp. of bleach per gallon of water to avoid
damaging your humidier.
3. Please make sure the rubber ring & rubber cap & spring on
the tank cap is installed properly after cleaning to avoid
water leakage. Please refer to the diagram on page 5.
15-20
minutes
Weekly Maintenance
1.To properly clean your humidier,we recommend you to
remove scale and disinfect the humidier separately.
Weekly Maintenance
1. Follow steps 1-2 of the previous section on scale removal.
2. Fill the water tank half full. Add ½ tsp of bleach. Place the tank
cap back on. Swish the solution around in tank. Place the tank
on the base. The bleach solution will enter and disinfect the
water reservoir as well as the other components. Set it still for
15-20 minutes.
3. Follow steps 4-6 of the previous section on scale removal to
complete disinfecting the humidier.
End-Of-Season Care and Storage
TROUBLESHOOTING GUIDE
1.If the information listed in the troubleshooting guide cant
solve your problem,please email us for help.
2. Failure to keep this unit clean from mineral deposits may
affect operation of this unit.
3. Customer failure to follow these instructions may void the
warranty.
1.Spring
2.Rubber ring
1
2
Waterless indicator
is constantly on.
No water in the
water reservoir.
Ensure unit is properly
plugged in.
Try another power
outlet.
Ensure the spring is
secured properly to the
tank allowing water to
pass through to the base.
1
Problem Possible Cause Solution
Failed to turn on
the unit.
Failed to turn on
the unit.
No power from
power outlet.
Problem Possible Cause Solution
Solution
Not enough water
inside the tank.
Refill and re-install the
water tank.
Mist level is set too low.
Adjust to larger mist
output.
The base might be
overfilled.
Remove the tank, empty
the base and place back
the filled tank on the
empty base.
Mineral buildup on
atomizer.
Tank may be
damaged.
Tank cap is not
tightened securely.
Rubber ring was not
installed on tank cap.
Spring get stuck.
Check for possible cracks
in the tank. Ask for a
replacement if It is
damaged.
Tighten the tank cap.
Check the tank cap for
rubber ring, contact us
if any is missing.
Ensure the spring is
secured properly to the
tank allowing water to
pass through to the base.
The unit is on but no
mist or little mist is
produced.
Put your hand towards
the nozzle and feel if
there is air coming out. If
yes,clean the water scale
on theatomizer as
instructed(p11).
2
1
1
Problem Possible Cause Solution
Tank leakage.
Mist height is low.
damping surrounding
desk or floor.
Condensation forms
around humidifier
or on windows and
walls.
Mist level is set too
high for the room size.
1. Check if the room is too
humid, adjust to lower
mist output.
2. Open door and windows,
or change to a larger room.
Air inlet is blocked.
Humidifier should be
placed on a hard flat
surface, 2 feet above the
floor, 12 inches away from
the wall.
Point mist outlet away
from wall or window.
Low indoor temper-
ature- leads to
liquefaction.
Raise the room temper-
ature to25/77.
1-1. Adjust to maximum
mist output.
1-2. Close door or windows
to reduce air ventilation,
or change to a smaller
room.
Humidifier should be
placed on a hard flat
surface, 2 feet above the
floor,12 inches away from
the wall.
Unit needs to be
cleaned.
Water is going down
to the water reservoir.
Clean the humidifier as
instructed.
Raise the room temper-
ature to25/77.
Strange odor.
Leave the empty water
tank open in a cool place
for 12 hours without the
water tank cap attached.
Strange water noise.
This is normal while it is
working.
Poor humidification.
Mist level is set too
low for the room size.
Air inlet is blocked.
Low indoor temper-
ature leads to
liquefaction.
CORRECT DISPOSAL OF THIS PRODUCT
Waste Electrical & Electronic Equipment
This Marking shown on the product or its
literature, indicate that it should not be
disposed with other household wastes
at the end of its working life.
To prevent possible harm to the environment or human health
from uncontrolled waste disposal, please separate this from
other types of wastes and recycle it responsibly to promote
the sustainable reuse of material resources.
Household user should contact either the retailer where they
purchased this product, or their local government office, for
details of where and how they can take this item for
environmentally safe recycling.
Business users should contact their supplier and check the
terms and conditions of the purchase contact. This product
should not be mixed with other commercial wastes for
disposal.
Problem Possible Cause Solution
White dust appears /
Black coating in the
base flakes off.
Tap water may contain
too much minerals.
Replace with filtered or
distilled water.
Unit works long hours.
Humidifier is getting
too hot.
Power off and place in a
well-ventilated place for
10 minutes.
WARRANTY
immediately to launch a warranty claim. Specify model number
and your Amazon order number. Our Consumer Service
Representative will respond within 2 business day, advise you
how to correct the problem yourself, or instruct you on how to r
eturn the defective unit back to us for repair or replacement.
We can only provide after sales service for products that are sold
by raydrop or raydrop authorized retailers and distributors. If you
have purchased your unit from a different place, please contact
your seller for return and warranty issues.
SERVICE GUARANTEE
Each raydrop humidier can enjoy up to 12 months replacement
warranty if there are any problems on quality.
And if you have any problem using our product,please feel free
to send an email to us.
E-mail: support@raydrop.net
Website: www.raydrop.net
This product is covered with raydrop product and labor warranty
for 12 months from the date of its original purchase. You will be
given a warranty extension of 18 months if the product is
registered on our website. (www.raydrop.net)
If any problems occur, please contact raydrop support
(support@raydrop.net)
1 2
1 2
1 2
30cm30cm
1. DO NOT plug the unit with wet hands.
2. DO NOT direct the mist outlet against the wall.
1. DO NOT use your hand or any other object to cover the mist
outlet while the unit is on to avoid damaging the product or
causing injury.
2. DO NOT clean the unit while it is connected to a power
source or while it is on.
1. DO NOT move or tilt the humidier while it is in operation.
2. The most comfortable environmental humidity is between
40%-60%. Please adjust the mist as needed.
1
1 2
1 2
2
hum idity
40%- 60%
1
1 2
2
!
1. Follow the cleaning instructions when the humidier will
not be used for at least one week, or at the end of the season.
Remove any accessories used with the humidier and allow
the humidier and accessories to dry completely before
storing.
2. DO NOT store with water inside the base, water reservoir, or
tank.
3. Pack the unit safely and store in a cool,dry location.
01 02
03 04
05 06
07 08
09 10
11 12
13 14
15 16
17 18
7
Cleaning Brush × 1
Press to turn on/off the colorful cycle light.
Colorful Cycle Light:
Loading ...
Loading ...
Loading ...

Other documents for Raydrop KC-RD06

The following documents are available:
User Manual Specification Photos

Specifications

See other models: KC-RD05G KC-RD05